RESUMO
The aim of this study was to develop a high-performance liquid chromatography-tandem mass spectrometry method for the determination of 6-cyanodopamine, 6-nitrodopamine, 6-nitrodopa, 6-nitroadrenaline and 6-bromodopamine in human plasma samples. Strata-X 33 µm solid-phase extraction cartridges were used for the extraction of the catecholamines from human plasma samples. The catecholamines were separated in a 150 × 3 mm Shim-pack GIST C18-AQ column with 3 µm particle size, placed in an oven at 40°C and perfused with 82% mobile phase A (acetonitrile-H2O; 90:10, v/v) + 0.4% acetic acid and 18% mobile phase B (deionized H2O) + 0.2% formic acid at a flow rate of 340 µl/min in isocratic mode. The injected volume was 4 µl and the run lasted 4 min. The method was linear from 0.1 to 20 ng/ml and the lower limit of quantification was 0.1 ng/ml for all analytes. The method was applied to evaluate the plasma levels of catecholamines in plasma of patients with chronic kidney disease and allowed the detection for the first time of circulating levels of the novel catecholamines 6-bromodopamine and 6-cyanodopamine.
Assuntos
Limite de Detecção , Insuficiência Renal Crônica , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Modelos Lineares , Insuficiência Renal Crônica/sangue , Cromatografia Líquida de Alta Pressão/métodos , Masculino , Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Dopamina/sangue , Dopamina/análogos & derivados , Catecolaminas/sangue , Pessoa de Meia-Idade , Espectrometria de Massa com Cromatografia LíquidaRESUMO
There is a strong scientific rationale to use nebulised unfractionated heparin (UFH) in treating patients with COVID-19. This pilot study investigated whether nebulised UFH was safe and had any impact on mortality, length of hospitalisation and clinical progression, in the treatment of hospitalised patients with COVID-19. This parallel group, open label, randomised trial included adult patients with confirmed SARS-CoV-2 infection admitted to two hospitals in Brazil. One hundred patients were planned to be randomised to either "standard of care" (SOC) or SOC plus nebulized UFH. The trial was stopped after randomisation of 75 patients due to falling COVID-19 hospitalisation rates. Significance tests were 1-sided test (10% significance level). The key analysis populations were intention to treat (ITT) and modified ITT (mITT) which excluded (from both arms) subjects admitted to ITU or who died within 24 h of randomisation. In the ITT population (n = 75), mortality was numerically lower for nebulised UFH (6 out of 38 patients; 15.8%) versus SOC (10 out of 37 patients; 27.0%), but not statistically significant; odds ratio (OR) 0.51, p = 0.24. However, in the mITT population, nebulised UFH reduced mortality (OR 0.2, p = 0.035). Length of hospital stay was similar between groups, but at day 29, there was a greater improvement in ordinal score following treatment with UFH in the ITT and mITT populations (p = 0.076 and p = 0.012 respectively), while mechanical ventilation rates were lower with UFH in the mITT population (OR 0.31; p = 0.08). Nebulised UFH did not cause any significant adverse events. In conclusion, nebulised UFH added to SOC in hospitalised patients with COVID-19 was well tolerated and showed clinical benefit, particularly in patients who received at least 6 doses of heparin. This trial was funded by The J.R. Moulton Charity Trust and registered under REBEC RBR-8r9hy8f (UTN code: U1111-1263-3136).
Assuntos
COVID-19 , Adulto , Humanos , Heparina/efeitos adversos , Projetos Piloto , SARS-CoV-2 , Hospitalização , Resultado do TratamentoRESUMO
AIM: To assess the bioequivalence of two sodium valproate formulations in healthy subjects of both sexes. MATERIALS AND METHODS: The study was conducted using an open, randomized, two-period crossover design with a 2-week washout interval. Plasma samples were obtained over a 96-hour period. Plasma concentrations of valproate were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC/MS) with negative ion electrospray ionization. From the sodium valproate plasma concentration vs. time curves, the following pharmacokinetic parameters were obtained Cmax, AUC, tmax, Ke, and T1/2. RESULTS: The geometric mean with corresponding 90% confidence interval for test/reference percent ratios were 104.43% (90% CI 100.42 - 108.61%) for Cmax, 98.11% (90% CI = 94.66 - 101.70%) for AUClast, and 96.71% (90% CI = 92.97 - 100.60%) for AUC0-inf. CONCLUSION: Since the 90% CI for Cmax and AUClast ratios were all inside the 80 - 125% interval proposed by the US Food and Drug Administration Agency (FDA), it was concluded that the new sodium valproate formulation (epilenil 500-mg coated tablet) without food elaborated by Biolab Sanus Farmaceutica Ltda is bioequivalent to depakene formulation for both the rate and the extent of absorption.
Assuntos
Jejum , Ácido Valproico , Área Sob a Curva , Disponibilidade Biológica , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Feminino , Voluntários Saudáveis , Humanos , Masculino , Comprimidos , Equivalência TerapêuticaRESUMO
The tolerability of a 2.5% lidocaine/prilocaine hydrogel (Nanorap, Biolab Indústria Farmacêutica Ltd., Sao Paulo, Brazil) was evaluated in 20 children ages 2 to 11 years undergoing cryotherapy for molluscum contagiosum (MC). The product was well tolerated, with only two children presenting with eczema at the application site. These adverse reactions were considered unlikely to be related to the test product, because a patch test was negative in one of the individuals and the other event occurred in only one of the two treated areas. Nanorap is an efficacious and well-tolerated option for topical anesthesia in children undergoing cryotherapy for MC.
Assuntos
Anestésicos Locais/uso terapêutico , Crioterapia/efeitos adversos , Tolerância a Medicamentos , Molusco Contagioso/diagnóstico , Molusco Contagioso/terapia , Dor/prevenção & controle , Criança , Pré-Escolar , Crioterapia/métodos , Combinação de Medicamentos , Feminino , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Lidocaína/uso terapêutico , Masculino , Dor/etiologia , Medição da Dor , Prilocaína/uso terapêutico , Resultado do TratamentoRESUMO
OBJECTIVES: The objective of this research was to evaluate the efficacy of a new antifungal imidazole, dapaconazole tosylate, in the treatment of Pityriasis versicolor (PV). DESIGN AND METHODS: Sixty patients with clinical and mycological diagnosis of PV were randomly assigned to receive either 1 g dapaconazole tosylate 2% cream or 1 g ketoconazole 2% cream. Treatments were applied once a day for 28 days. A dermatologist evaluated efficacy and safety daily, and weekly laboratorial tests were performed. The primary end point was a clinical and mycological cure of lesions after 28 days of treatment. The secondary end point was the time to clinical healing assessed by Kaplan-Meier analysis and Log-rank testing. RESULTS: Fifty-three patients adhered to protocol rules. Clinical and mycological cure was achieved in 84.6% (22/26) and 92.6% (25/27) of patients treated with ketoconazole and dapaconazole, respectively (difference [effect size] = 8.0%, Standard error of difference: 8.69%, 95% CI: -6.3 to 22.3%). Median time to healing was 23.5 and 21 days for ketoconazole and dapaconazole, respectively (p = 0.126). Adverse events occurred only in ketoconazole-treated patients (13%; 4/30). CONCLUSION: Dapaconazole tosylate is non-inferior to ketoconazole when used at a dose of 20 mg/day for 28 consecutive days for the treatment of PV. Dapaconazole also demonstrated a good safety profile.
Assuntos
Imidazóis/uso terapêutico , Cetoconazol/uso terapêutico , Tinha Versicolor/tratamento farmacológico , Administração Cutânea , Adolescente , Adulto , Antifúngicos/administração & dosagem , Antifúngicos/efeitos adversos , Antifúngicos/uso terapêutico , Método Duplo-Cego , Feminino , Humanos , Imidazóis/administração & dosagem , Imidazóis/efeitos adversos , Cetoconazol/administração & dosagem , Cetoconazol/efeitos adversos , Masculino , Pessoa de Meia-Idade , Tinha Versicolor/patologia , Resultado do Tratamento , Adulto JovemRESUMO
UNLABELLED: A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5µm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. CONCLUSION: This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).
Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Propiltiouracila/sangue , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Estudos Cross-Over , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Propiltiouracila/química , Propiltiouracila/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Equivalência Terapêutica , Adulto JovemRESUMO
A simple, selective and sensitive method based on high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) has been developed for the determination of dapaconazole in human plasma using tioconazole as internal standard. The drugs were extracted from plasma by liquid-liquid extraction with ether/hexane (80/20, v/v). The chromatography separation was performed on a Genesis(®) C18 reversed phase analytical column 4µm (100×2.1mm i.d.) with a mobile phase of methanol/acetonitrile/water (80/10/10, v/v/v)+ammonium acetate (0.5mM). Dapaconazole was quantified using a mass spectrometer with an electrospray source in the ESI positive mode (ES+) configured for multiple reaction monitoring (MRM) to monitor the transitions 415.1>159.2 and 387.0>131.0 for dapaconazole and tioconazole, respectively. The method had a chromatography run time of 3.8min and a linear calibration curve over the range 0.2-100ng/mL (r=0.9998). The lower limit of quantification (LLOQ) was 0.2ng/mL. The precision and accuracy values of the assay were within ±10%. The stability tests indicate no significant degradation under the conditions of the experiment. This method was used for a phase I study of topical administration of dapaconazole tosylate in healthy human male volunteers.
Assuntos
Antifúngicos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Imidazóis/sangue , Monitoramento de Medicamentos/métodos , Humanos , Limite de Detecção , Masculino , Espectrometria de Massas em Tandem/métodosRESUMO
A rapid, sensitive and specific method for quantifying ciprofibrate in human plasma using bezafibrate as the internal standard (IS) is described. The sample was acidified prior extraction with formic acid (88%). The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (diethyl ether/dichloromethane 70/30 (v/v)). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed using Genesis C18 4 µm analytical column (4.6 × 150 mm i.d.) and a mobile phase consisting of acetonitrile/water (70/30, v/v) and 1mM acetic acid. The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 0.1-60 µg/mL (r>0.99). The limit of quantification was 0.1 µg/mL. The intra- and interday accuracy and precision values of the assay were less than 13.5%. The stability tests indicated no significant degradation. The recovery of ciprofibrate was 81.2%, 73.3% and 76.2% for the 0.3, 5.0 and 48.0 ng/mL standard concentrations, respectively. For ciprofibrate, the optimized parameters of the declustering potential, collision energy and collision exit potential were -51 V, -16 eV and -5 V, respectively. The method was also validated without the use of the internal standard. This HPLC-MS/MS procedure was used to assess the bioequivalence of two ciprofibrate 100mg tablet formulations in healthy volunteers of both sexes. The following pharmacokinetic parameters were obtained from the ciprofibrate plasma concentration vs. time curves: AUC(last), AUC(0-168 h), C(max) and T(max). The geometric mean with corresponding 90% confidence interval (CI) for test/reference percent ratios were 93.80% (90% CI=88.16-99.79%) for C(max,) 98.31% (90% CI=94.91-101.83%) for AUC(last) and 97.67% (90% CI=94.45-101.01%) for AUC(0-168 h). Since the 90% CI for AUC(last), AUC(0-168 h) and C(max) ratios were within the 80-125% interval proposed by the US FDA, it was concluded that ciprofibrate (Lipless 100mg tablet) formulation manufactured by Biolab Sanus Farmacêutica Ltda. is bioequivalent to the Oroxadin (100 mg tablet) formulation for both the rate and the extent of absorption.