Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 127(20): 201801, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34860065

RESUMO

This Letter reports results from the first long-baseline search for sterile antineutrinos mixing in an accelerator-based antineutrino-dominated beam. The rate of neutral-current interactions in the two NOvA detectors, at distances of 1 and 810 km from the beam source, is analyzed using an exposure of 12.51×10^{20} protons-on-target from the NuMI beam at Fermilab running in antineutrino mode. A total of 121 of neutral-current candidates are observed at the far detector, compared to a prediction of 122±11(stat.)±15(syst.) assuming mixing only between three active flavors. No evidence for ν[over ¯]_{µ}→ν[over ¯]_{s} oscillation is observed. Interpreting this result within a 3+1 model, constraints are placed on the mixing angles θ_{24}<25° and θ_{34}<32° at the 90% C.L. for 0.05 eV^{2}≤Δm_{41}^{2}≤0.5 eV^{2}, the range of mass splittings that produces no significant oscillations at the near detector. These are the first 3+1 confidence limits set using long-baseline accelerator antineutrinos.

2.
Phys Rev Lett ; 123(15): 151803, 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31702305

RESUMO

The NOvA experiment has seen a 4.4σ signal of ν[over ¯]_{e} appearance in a 2 GeV ν[over ¯]_{µ} beam at a distance of 810 km. Using 12.33×10^{20} protons on target delivered to the Fermilab NuMI neutrino beamline, the experiment recorded 27 ν[over ¯]_{µ}→ν[over ¯]_{e} candidates with a background of 10.3 and 102 ν[over ¯]_{µ}→ν[over ¯]_{µ} candidates. This new antineutrino data are combined with neutrino data to measure the parameters |Δm_{32}^{2}|=2.48_{-0.06}^{+0.11}×10^{-3} eV^{2}/c^{4} and sin^{2}θ_{23} in the ranges from (0.53-0.60) and (0.45-0.48) in the normal neutrino mass hierarchy. The data exclude most values near δ_{CP}=π/2 for the inverted mass hierarchy by more than 3σ and favor the normal neutrino mass hierarchy by 1.9σ and θ_{23} values in the upper octant by 1.6σ.

3.
Phys Rev Lett ; 118(23): 231801, 2017 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-28644674

RESUMO

Results are reported from an improved measurement of ν_{µ}→ν_{e} transitions by the NOvA experiment. Using an exposure equivalent to 6.05×10^{20} protons on target, 33 ν_{e} candidates are observed with a background of 8.2±0.8 (syst.). Combined with the latest NOvA ν_{µ} disappearance data and external constraints from reactor experiments on sin^{2}2θ_{13}, the hypothesis of inverted mass hierarchy with θ_{23} in the lower octant is disfavored at greater than 93% C.L. for all values of δ_{CP}.

4.
Phys Rev Lett ; 118(15): 151802, 2017 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-28452513

RESUMO

This Letter reports new results on muon neutrino disappearance from NOvA, using a 14 kton detector equivalent exposure of 6.05×10^{20} protons on target from the NuMI beam at the Fermi National Accelerator Laboratory. The measurement probes the muon-tau symmetry hypothesis that requires maximal θ_{23} mixing (θ_{23}=π/4). Assuming the normal mass hierarchy, we find Δm_{32}^{2}=(2.67±0.11)×10^{-3} eV^{2} and sin^{2}θ_{23} at the two statistically degenerate values 0.404_{-0.022}^{+0.030} and 0.624_{-0.030}^{+0.022}, both at the 68% confidence level. Our data disfavor the maximal mixing scenario with 2.6σ significance.

5.
Phys Rev Lett ; 116(15): 151806, 2016 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-27127961

RESUMO

We report results from the first search for ν_{µ}→ν_{e} transitions by the NOvA experiment. In an exposure equivalent to 2.74×10^{20} protons on target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of 0.99±0.11(syst) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of 1.07±0.14(syst). The 3.3σ excess of events observed in the primary analysis disfavors 0.1π<δ_{CP}<0.5π in the inverted mass hierarchy at the 90% C.L.

6.
Br J Surg ; 102(4): 368-74, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25689292

RESUMO

BACKGROUND: The aim was to review a consecutive series of patients treated with laparoscopic abdominal aortic aneurysm (AAA) repair. These patients were compared with patients having elective open AAA repair. METHODS: Demographic and operative details were collected prospectively and outcomes recorded for all patients undergoing laparoscopic or open AAA repair. RESULTS: A total of 316 patients underwent laparoscopic (51), open (53) or endovascular (EVAR; 212) AAA repair between 2007 and 2013. The median age of patients who had laparoscopic or open repair was 72 (i.q.r. 66-75) years, and 92·3 per cent were men. There was no significant difference in sex distribution, age or V-POSSUM physiology score between laparoscopic and open repair. Of the 51 laparoscopic procedures, six were totally laparoscopic, 43 were laparoscopically assisted and two were converted to open repair. Pain scores were similar on days 1 and 3 after laparoscopic and open repair, even though epidurals were used in the open group, and were lower on days 5 and 7 after laparoscopic procedures. Patients who had laparoscopic repair had significantly fewer postoperative cardiorespiratory and renal complications (P = 0·017), and were discharged from hospital sooner (median 5 (i.q.r. 3-7) versus 8 (6-11) days; P = 0 ·001). CONCLUSION: Laparoscopic AAA repair was performed safely, and with at least equivalent outcomes to open repair, in patients unfavourable for EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Laparoscopia/métodos , Idoso , Constrição , Procedimentos Cirúrgicos Eletivos/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Laparoscopia/efeitos adversos , Tempo de Internação , Masculino , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/etiologia , Seleção de Pacientes , Estudos Prospectivos , Resultado do Tratamento
7.
Phys Rev Lett ; 110(25): 251801, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23829728

RESUMO

We report measurements of oscillation parameters from ν(µ) and ν(µ) disappearance using beam and atmospheric data from MINOS. The data comprise exposures of 10.71×10(20) protons on target in the ν(µ)-dominated beam, 3.36×10(20) protons on target in the ν(µ)-enhanced beam, and 37.88 kton yr of atmospheric neutrinos. Assuming identical ν and ν oscillation parameters, we measure |Δm2| = (2.41(-0.10)(+0.09))×10(-3) eV2 and sin2(2θ) = 0.950(-0.036)(+0.035). Allowing independent ν and ν oscillations, we measure antineutrino parameters of |Δm2| = (2.50(-0.25)(+0.23))×10(-3) eV2 and sin2(2θ) = 0.97(-0.08)(+0.03), with minimal change to the neutrino parameters.

8.
Phys Rev Lett ; 110(17): 171801, 2013 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-23679706

RESUMO

We report on ν(e) and ν(e) appearance in ν(µ) and ν(µ) beams using the full MINOS data sample. The comparison of these ν(e) and ν(e) appearance data at a 735 km baseline with θ13 measurements by reactor experiments probes δ, the θ23 octant degeneracy, and the mass hierarchy. This analysis is the first use of this technique and includes the first accelerator long-baseline search for ν(µ) → ν(e). Our data disfavor 31% (5%) of the three-parameter space defined by δ, the octant of the θ23, and the mass hierarchy at the 68% (90%) C.L. We measure a value of 2sin(2)(2θ13)sin(2)(θ23) that is consistent with reactor experiments.

9.
Phys Rev Lett ; 108(19): 191801, 2012 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-23003026

RESUMO

We report an improved measurement of ν(µ) disappearance over a distance of 735 km using the MINOS detectors and the Fermilab Main Injector neutrino beam in a ν(µ)-enhanced configuration. From a total exposure of 2.95×10(20) protons on target, of which 42% have not been previously analyzed, we make the most precise measurement of Δm2=[2.62(-0.28)(+0.31)(stat)±0.09(syst)]×10(-3) eV2 and constrain the ν(µ) mixing angle sin2(2θ)>0.75 (90% C.L.). These values are in agreement with Δm2 and sin2(2θ) measured for ν(µ), removing the tension reported in [P. Adamson et al. (MINOS), Phys. Rev. Lett. 107, 021801 (2011).].

10.
Phys Rev Lett ; 106(18): 181801, 2011 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-21635083

RESUMO

Measurements of neutrino oscillations using the disappearance of muon neutrinos from the Fermilab NuMI neutrino beam as observed by the two MINOS detectors are reported. New analysis methods have been applied to an enlarged data sample from an exposure of 7.25×10(20) protons on target. A fit to neutrino oscillations yields values of |Δm(2)|=(2.32(-0.08)(+0.12))×10(-3) eV(2) for the atmospheric mass splitting and sin(2)(2θ)>0.90 (90% C.L.) for the mixing angle. Pure neutrino decay and quantum decoherence hypotheses are excluded at 7 and 9 standard deviations, respectively.

11.
Phys Rev Lett ; 107(1): 011802, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21797535

RESUMO

Results are reported from a search for active to sterile neutrino oscillations in the MINOS long-baseline experiment, based on the observation of neutral-current neutrino interactions, from an exposure to the NuMI neutrino beam of 7.07×10(20) protons on target. A total of 802 neutral-current event candidates is observed in the Far Detector, compared to an expected number of 754 ± 28(stat) ± 37(syst) for oscillations among three active flavors. The fraction f(s) of disappearing ν(µ) that may transition to ν(s) is found to be less than 22% at the 90% C.L.

12.
Phys Rev Lett ; 107(2): 021801, 2011 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-21797594

RESUMO

This Letter reports the first direct observation of muon antineutrino disappearance. The MINOS experiment has taken data with an accelerator beam optimized for ν(µ) production, accumulating an exposure of 1.71 × 10²° protons on target. In the Far Detector, 97 charged current ν(µ) events are observed. The no-oscillation hypothesis predicts 156 events and is excluded at 6.3σ. The best fit to oscillation yields |Δm²| = [3.36(-0.40)(+0.46)(stat) ± 0.06(syst)] × 10⁻³ eV², sin²(2θ) = 0.86(-0.12)(+0.11)(stat) ± 0.01(syst). The MINOS ν(µ) and ν(µ) measurements are consistent at the 2.0% confidence level, assuming identical underlying oscillation parameters.

13.
Phys Rev Lett ; 107(18): 181802, 2011 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-22107623

RESUMO

We report the results of a search for ν(e) appearance in a ν(µ) beam in the MINOS long-baseline neutrino experiment. With an improved analysis and an increased exposure of 8.2 × 10(20) protons on the NuMI target at Fermilab, we find that 2 sin(2) (θ(23))sin(2)(2θ(13))<0.12(0.20) at 90% confidence level for δ = 0 and the normal (inverted) neutrino mass hierarchy, with a best-fit of 2sin(2) (θ(23))sin(2)(2θ(13)) = 0.041(-0.031)(+0.047) (0.079(-0.053) (+0.071)). The θ(13) = 0 hypothesis is disfavored by the MINOS data at the 89% confidence level.

14.
J Dent Res ; 100(11): 1220-1227, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34077690

RESUMO

Dental care professionals (DCPs) are thought to be at enhanced risk of occupational exposure to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, robust data to support this from large-scale seroepidemiological studies are lacking. We report a longitudinal seroprevalence analysis of antibodies to SARS-CoV-2 spike glycoprotein, with baseline sampling prior to large-scale practice reopening in July 2020 and follow-up postimplementation of new public health guidance on infection prevention control (IPC) and enhanced personal protective equipment (PPE). In total, 1,507 West Midlands DCPs were recruited into this study in June 2020. Baseline seroprevalence was determined using a combined IgGAM enzyme-linked immunosorbent assay and the cohort followed longitudinally for 6 mo until January/February 2021 through the second wave of the coronavirus disease 2019 pandemic in the United Kingdom and vaccination commencement. Baseline seroprevalence was 16.3%, compared to estimates in the regional population of 6% to 7%. Seropositivity was retained in over 70% of participants at 3- and 6-mo follow-up and conferred a 75% reduced risk of infection. Nonwhite ethnicity and living in areas of greater deprivation were associated with increased baseline seroprevalence. During follow-up, no polymerase chain reaction-proven infections occurred in individuals with a baseline anti-SARS-CoV-2 IgG level greater than 147.6 IU/ml with respect to the World Health Organization international standard 20-136. After vaccination, antibody responses were more rapid and of higher magnitude in those individuals who were seropositive at baseline. Natural infection with SARS-CoV-2 prior to enhanced PPE was significantly higher in DCPs than the regional population. Natural infection leads to a serological response that remains detectable in over 70% of individuals 6 mo after initial sampling and 9 mo from the peak of the first wave of the pandemic. This response is associated with protection from future infection. Even if serological responses wane, a single dose of the Pfizer-BioNTech 162b vaccine is associated with an antibody response indicative of immunological memory.


Assuntos
COVID-19 , Vacinas , Assistência Odontológica , Humanos , SARS-CoV-2 , Estudos Soroepidemiológicos , Reino Unido/epidemiologia
15.
Front Artif Intell ; 4: 649917, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34505055

RESUMO

In liquid argon time projection chambers exposed to neutrino beams and running on or near surface levels, cosmic muons, and other cosmic particles are incident on the detectors while a single neutrino-induced event is being recorded. In practice, this means that data from surface liquid argon time projection chambers will be dominated by cosmic particles, both as a source of event triggers and as the majority of the particle count in true neutrino-triggered events. In this work, we demonstrate a novel application of deep learning techniques to remove these background particles by applying deep learning on full detector images from the SBND detector, the near detector in the Fermilab Short-Baseline Neutrino Program. We use this technique to identify, on a pixel-by-pixel level, whether recorded activity originated from cosmic particles or neutrino interactions.

16.
Eur Phys J C Part Fields ; 81(4): 322, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720713

RESUMO

The Deep Underground Neutrino Experiment (DUNE) will be a powerful tool for a variety of physics topics. The high-intensity proton beams provide a large neutrino flux, sampled by a near detector system consisting of a combination of capable precision detectors, and by the massive far detector system located deep underground. This configuration sets up DUNE as a machine for discovery, as it enables opportunities not only to perform precision neutrino measurements that may uncover deviations from the present three-flavor mixing paradigm, but also to discover new particles and unveil new interactions and symmetries beyond those predicted in the Standard Model (SM). Of the many potential beyond the Standard Model (BSM) topics DUNE will probe, this paper presents a selection of studies quantifying DUNE's sensitivities to sterile neutrino mixing, heavy neutral leptons, non-standard interactions, CPT symmetry violation, Lorentz invariance violation, neutrino trident production, dark matter from both beam induced and cosmogenic sources, baryon number violation, and other new physics topics that complement those at high-energy colliders and significantly extend the present reach.

17.
Lab Chip ; 10(17): 2242-50, 2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20571691

RESUMO

We present an inexpensive hand-held device (240 g) that implements microchip isotachophoresis (ITP) with laser induced fluorescence (LIF) detection. This self-contained instrument integrates the functionality required for high voltage generation onto a microelectronic chip, includes LIF detection and is powered by a universal serial bus (USB) link connected to a laptop computer. Using this device we demonstrate focusing and detection of a fluorescent species with a limit of detection of 100 pM. We show that the response of the detector is linear with the initial analyte concentration, making this device suitable for quantitative analysis. We also demonstrate the use of our simulation tools for design and prediction of ITP assays, and validate these results with a demonstration of multiplexed indirect detection of (unlabeled) analytes performed using the device. We find good agreement between simulations and experimental results. Using a label-free isotachaphoresis assay implemented in the hand-held device we detect two explosives and an endocrine disruptor spiked in river water, with no prior sample processing.

18.
Anal Chem ; 82(5): 1858-66, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20141152

RESUMO

We present a novel method for fluorescence-based indirect detection of analytes and demonstrate its use for label-free detection of chemical toxins in a hand-held device. We fluorescently label a mixture of low-concentration carrier ampholytes and introduce it into an isotachophoresis (ITP) separation. The carrier ampholytes provide a large number of fluorescent species with a wide range of closely spaced effective electrophoretic mobilities. Analytes focus under ITP and displace subsets of these carrier ampholytes. The analytes are detected indirectly and quantified by analyzing the gaps in the fluorescent ampholyte signal. The large number (on the order of 1000) of carrier ampholytes enables detection of a wide range of analytes, requiring little a priori knowledge of their electrophoretic properties. We discuss the principles of the technique and demonstrate its use in the detection of various analytes using a standard microscope system. We then present the integration of the technique into a self-contained hand-held device and demonstrate detection of chemical toxins (2-nitrophenol and 2,4,6-trichlorophenol) in tap water, with no sample preparation steps.

19.
Phys Rev Lett ; 105(15): 151601, 2010 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-21230890

RESUMO

We searched for a sidereal modulation in the MINOS far detector neutrino rate. Such a signal would be a consequence of Lorentz and CPT violation as described by the standard-model extension framework. It also would be the first detection of a perturbative effect to conventional neutrino mass oscillations. We found no evidence for this sidereal signature, and the upper limits placed on the magnitudes of the Lorentz and CPT violating coefficients describing the theory are an improvement by factors of 20-510 over the current best limits found by using the MINOS near detector.

20.
Analyst ; 135(7): 1606-17, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20369214

RESUMO

We demonstrate a new and extremely inexpensive, multipurpose desktop system for operating lab-on-a-chip (LOC) devices. The system provides all of the infrastructure necessary for genetic amplification and analysis, with orders of magnitude improvement in performance over our previous work. A modular design enables high levels of integration while allowing scalability to lower cost and smaller size. The component cost of this system is ca. $600, yet it could support many diagnostic applications. We demonstrate an implementation of genetic amplification via polymerase chain reaction (PCR), and analysis using capillary electrophoresis (CE). The PCR is able to amplify from single or several copies of target DNA and the CE performance (e.g. sensitivity) is comparable to that of commercial photomultiplier-based confocal lab-on-chip instrumentation. We believe this demonstrates that the cost of infrastructure need no longer be a barrier to the wide-spread application of LOC technologies in healthcare and beyond.


Assuntos
DNA/análise , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Eletroquímicas , Eletroforese Capilar/métodos , Técnicas Analíticas Microfluídicas/métodos , Reação em Cadeia da Polimerase/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA