Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 23(4): 125, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-39076223

RESUMO

Background: A 70 years-old superobese man (weighted 230 kg) was referred to our hospital for recurrent syncope due to asystole alternating to atrial fibrillation. Convectional pacing was highly challenging; therefore, it was decided to implant a leadless pacemaker in a multidisciplinary intervention with surgical management of the femoral venous access. Methods: In a fully equipped operating room with bariatric table and appropriately dimensioned fluoroscope, a vascular surgeon performed surgical isolation of the right common femoral vein. After that, we proceeded to insert sheaths via the femoral vein, and through that a steerable transcatheter delivery system for the device. Results: The implant was successful without complication. Conclusions: Leadless pacemaker implantation can be effectively and safely performed even in superobese patients. Vascular access, fluoroscopic guidance and electronic interrogation could be easily managed and do not constitute a limit.

2.
Eur Heart J Qual Care Clin Outcomes ; 10(5): 467-478, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-38289824

RESUMO

AIMS: Update data regarding the atrial fibrillation (AF)-related mortality trend in Europe remain scant. We assess the age- and sex-specific trends in AF-related mortality in the European states between the years 2008 and 2019. METHODS AND RESULTS: Data on cause-specific deaths and population numbers by sex for European countries were retrieved through the publicly available World Health Organization mortality dataset for the years 2008-2019. Atrial fibrillation-related deaths were ascertained when the International Classification of Diseases, 10th Revision code I48 was listed as the underlying cause of death in the medical death certificate. To calculate annual trends, we assessed the average annual % change (AAPC) with relative 95% confidence intervals (CIs) using Joinpoint regression. During the study period, 773 750 AF-related deaths (202 552 males and 571 198 females) occurred in Europe. The age-adjusted mortality rate (AAMR) linearly increased from 12.3 (95% CI: 11.2-12.9) per 100 000 population in 2008 to 15.3 (95% CI: 14.7-15.7) per 100 000 population in 2019 [AAPC: +2.0% (95% CI: 1.6-3.5), P < 0.001] with a more pronounced increase among men [AAPC: +2.7% (95% CI: 1.9-3.5), P < 0.001] compared with women [AAPC: +1.7% (95% CI: 1.1-2.3), P < 0.001] (P for parallelism 0.01). Higher AAMR increases were observed in some Eastern European countries such as Latvia, Lithuania, and Poland, while the lower increases were mainly clustered in Central Europe. CONCLUSION: Over the last decade, the age-adjusted AF-related mortality has increased in Europe, especially among males. Disparities still exist between Western and Eastern European countries.


Assuntos
Fibrilação Atrial , Causas de Morte , Humanos , Fibrilação Atrial/mortalidade , Fibrilação Atrial/epidemiologia , Europa (Continente)/epidemiologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Causas de Morte/tendências , Taxa de Sobrevida/tendências , Idoso de 80 Anos ou mais , Distribuição por Sexo , Distribuição por Idade , Mortalidade/tendências , Estudos Retrospectivos , Adulto
3.
JACC Clin Electrophysiol ; 10(3): 554-565, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38243998

RESUMO

BACKGROUND: Axillary vein puncture (AVP) and cephalic vein surgical cutdown are recommended in international guidelines because of their low risk of pneumothorax and chronic lead complications. Directly visualizing and puncturing the axillary vein under ultrasound guidance reduces radiation exposure, provides direct needle visualization, and lowers periprocedural complications. Our hypothesis is that ultrasound-guided axillary access is safer and more feasible than the standard fluoroscopic technique. OBJECTIVES: The purpose of this study was to assess the efficacy and safety of ultrasound-guided axillary venous access during cardiac lead implantation for pacemakers (PMs) and implantable cardioverter-defibrillator (ICD) implantations. METHODS: Patients were randomized in a 1:1 fashion to either axillary venous access under fluoroscopic guidance or ultrasound-guided axillary venous access. The composite outcome, including pneumothorax, hemothorax, inadvertent arterial puncture, pocket hematoma, pocket infection, lead dislodgement, and death, was evaluated 30 days after implantation. RESULTS: We randomized 270 patients into 2 groups: the standard group for fluoroguided AVP (n = 134) and the experimental group for ultrasound-guided AVP (n = 136). No disparities in baseline characteristics were observed between the groups. The median age of the patients was 81 years, with women comprising 41% of the population. The majority of patients received single- and dual-chamber PMs (87% vs 88%; P = 1.00), and slightly over 10% in both groups received ICDs (13% vs 12%; P = 0.85). In total, we placed 357 leads in PMs and 48 leads in ICDs. Among these, 295 leads were inserted via axillary vein access and 110 via cephalic vein access. Notably, the subclavian vein was never used as a vascular access. The composite outcome was lower in the ultrasound group according to intention-to-treat analysis (OR: 0.55; 95% CI: 0.31-0.99; P = 0.034). The main difference within the composite outcome was the lower incidence of inadvertent axillary arterial puncture in the experimental group (17% vs 6%; P = 0.004). The ultrasound group also exhibited lower total procedural x-ray exposure (10,344 µGy × cm2 vs 7,119 µGy × cm2; P = 0.002) while achieving the same rate of success at the first attempt (61% vs 69%; P = 0.375). CONCLUSIONS: Ultrasound-guided AVP is safer than the fluoroscopy-guided approach because it achieves the same rate of acute success while maintaining low total procedural radiation exposure. Ultrasound AVP should be considered the optimal venous access method for cardiac lead implantation. (Ultrasound Guided Axillary Access vs Standard Fluoroscopic Technique for Cardiac Lead Implantation [ZEROFLUOROAXI]; NCT05101720).


Assuntos
Pneumotórax , Humanos , Feminino , Idoso de 80 Anos ou mais , Resultado do Tratamento , Veia Axilar/diagnóstico por imagem , Veia Axilar/cirurgia , Ultrassonografia de Intervenção/métodos , Fluoroscopia/métodos
4.
Biology (Basel) ; 13(4)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38666877

RESUMO

Arrhythmogenic cardiomyopathy (ACM) is a rare cardiac disease, characterized by the progressive replacement of myocardial tissue with fibrous and fatty deposits. It can involve both the right and left ventricles. It is associated with the development of life-threatening arrhythmias and culminates in sudden cardiac death. Electrocardiography (ECG) has emerged as a pivotal tool, offering diagnostic insights and prognostic information. The specific ECG abnormalities observed in ACM not only contribute to early detection but also hold the key to the prediction of the likelihood of severe complications. The recognition of these nuanced ECG manifestations has become imperative for clinicians as it guides them in the formulation of tailored therapeutic strategies that address both the present symptoms and the potential future risks.

5.
Biology (Basel) ; 13(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38392350

RESUMO

BACKGROUND: At the same conditions of delivered power and contact force, open-irrigated radiofrequency ablation catheters are believed to create deeper lesions, while non-irrigated ones produce shallower lesions. This ex vivo study aims to directly compare the lesion dimensions and characteristics of an irrigated ablation catheter with a flexible tip and a non-irrigated solid-tip catheter. METHODS: Radiofrequency lesions were induced on porcine myocardial slabs using both open-tip irrigated and non-irrigated standard 4 mm catheters at three power settings (20 W, 30 W, and 40 W), maintaining a fixed contact force of 10 gr. A lesion assessment was conducted including the lesion depth, depth at the maximum diameter, and lesion surface diameters, with the subsequent calculation of the lesion volume and area being undertaken. RESULTS: Irrigated catheters produced lesions with significantly higher superficial widths at all power levels (3.8 vs. 4.4 mm at 20 W; 3.9 mm vs. 4.4 mm at 30 W; 3.8 mm vs. 4.5 mm at 40 W; p = 0.001, p = 0.019, p = 0.003, respectively). Non-irrigated catheters resulted in significantly higher superficial areas at all power levels (23 mm2 vs. 18 mm2 at 20 W; 25 mm2 vs. 19 mm2 at 30 W; 26 mm2 vs. 19 mm2 at 40 W; p = 0.001, p = 0.005, p = 0.001, respectively). Irrigated catheters showed significantly higher values of lesion maximum depth at 40 W (4.6 mm vs. 5.5 mm; p = 0.007), while non-irrigated catheters had a significantly higher calculated volume at 20 W (202 µL vs. 134 µL; p = 0.002). CONCLUSIONS: Radiofrequency ablation using an irrigated catheter with a flexible tip has the potential to generate smaller superficial lesion areas compared with those obtained using a non-irrigated catheter.

6.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930000

RESUMO

Background: Modern treatments for transfusion-dependent ß-thalassemia (TDßT) have allowed patients to reach high life expectancy with no iron overload. Despite survival improvement, atrial fibrillation (AF) has emerged as a relevant issue. AF pathophysiology and characteristics in TDßT are different than in the general population. Epicardial adipose tissue (EAT) may play a role but its relationship with AF in patients with TDßT has not been explored. Methods: A monocentric, cross-sectional study, enrolling consecutive patients with TDßT. Epicardial adipose tissue (EAT) was evaluated at magnetic resonance. Characteristics of patients with and without history of AF were investigated. Factors independently associated with AF prevalence were analyzed. Results: A total of 116 patients were enrolled. All patients were treated with regular chelation therapy. The prevalence of AF was 29.3% (34/116). Cardiac T2* and liver iron concentration were no different between patients with and without AF. EAT thickness was significantly higher in patients with AF at left atrium, right atrium and right ventricle (5.0 vs. 4.0 mm, p < 0.01, 4.4 vs. 4.0, p = 0.02 and 5.0 vs. 4.3, p = 0.04). Patients with AF presented with older age, (53 vs. 49 years, p < 0.01), more hypothyroidism (44.1 vs. 20.7%, p = 0.01), pulmonary hypertension (23.5 vs. 2.4% p < 0.01), splenectomy (88.2 vs. 64.6%, p = 0.01), higher right and left atrial volume (61 vs. 40 and 74 vs. 43 mL, both p < 0.01). At multivariable analysis, hypothyroidism, left atrial volume and left atrial EAT were independently associated with AF (odds ratio 9.95, 1.09 and 1.91, respectively). Conclusions: In a contemporary cohort of patients with TDßT, treated with regular chelation therapy, prevalence of AF was unrelated to iron overload. EAT was independently associated with AF.

7.
Heart Rhythm ; 21(8): 1363-1369, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38467355

RESUMO

BACKGROUND: Cardiac conduction disorder (CCD) in patients <50 years old is a rare and mostly unknown condition. OBJECTIVE: We aimed to assess clinical characteristics and genetic background of patients <50 years old with CCD of unknown origin. METHODS: We retrospectively reviewed a consecutive series of patients with a diagnosis of CCD before the age of 50 years referred to our center between January 2019 and December 2021. Patients underwent complete clinical examination and genetic evaluation. RESULTS: We enrolled 39 patients with a median age of 40 years (28-47 years) at the onset of symptoms. A cardiac implantable electronic device was implanted in 69% of the patients. In 15 of 39 CCD index patients (38%), we found a total of 13 different gene variations (3 pathogenic, 6 likely pathogenic, and 4 variants of uncertain significance), mostly in 3 genes (SCN5A, TRPM4, and LMNA). In our cohort, genetic testing led to the decision to implant an implantable cardioverter-defibrillator in 2 patients for the increased risk of sudden cardiac death. CONCLUSION: Patients with the occurrence of CCD before the age of 50 years present with a high rate of pathologic gene variations, mostly in 3 genes (SCN5A, TRPM4, and LMNA). The presence of pathogenic variations may add information about the prognosis and lead to an individualized therapeutic approach.


Assuntos
Doença do Sistema de Condução Cardíaco , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Doença do Sistema de Condução Cardíaco/genética , Doença do Sistema de Condução Cardíaco/terapia , Doença do Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/diagnóstico , Testes Genéticos/métodos , Eletrocardiografia , Desfibriladores Implantáveis , Sistema de Condução Cardíaco/fisiopatologia , Canal de Sódio Disparado por Voltagem NAV1.5
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA