Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiologe ; 51(5): 366-71, 2011 May.
Artigo em Alemão | MEDLINE | ID: mdl-21431459

RESUMO

In morbidly obese patients, computed tomography frequently represents the only viable option for non-invasive imaging diagnostics. The aim of this study was to analyze the weight limits, dose and image quality with standard CT scanners and to determine the diagnostic value and dose with a dual source XXL mode.A total of 15 patients (average body weight 189.6 ± 42 kg) were retrospectively identified who had been examined with the XXL mode. Of these patients 7 (average body weight 176.4 ± 56 kg) had been examined using both the XXL and standard protocols allowing for an intraindividual comparison in this subcollective. Additionally 14 patients weighing between 90 and 150 kg (average 106.1 ± 19 kg) examined with standard protocols were included as references. Dose, image noise and subjectively assessed image quality (rating scale 1-4) were determined. Additionally, a large abdomen phantom of 48 cm diameter was examined with both protocols at equivalent tube current-time product in order to compare the dose efficiency.The patient groups differed significantly in dose (CTDI(vol) XXL 72.9 ± 23 versus standard 16.7 ± 11 mGy; intraindividual 64.1 ± 20 versus 27.0 ± 15 mGy). The image noise was generally somewhat higher in the XXL group but significantly lower in the intraindividual comparison (liver 24.2 ± 14 HU versus 36.3 ± 20 HU; p = 0.03; fat 15.5 ± 8 HU versus 26.2 ± 12 HU; p=0.02). With ratings of 1.9 ± 0.7 and 1.8 ± 0.7 image quality did not differ significantly in general, whereas there was a clear difference in the intraindividual comparison (1.8 ± 0.8 versus 3.0 ± 1.2) and only the XXL protocol achieved diagnostic quality in all cases, while 43% of the examinations with the standard protocol were rated as non-diagnostic. The quantification of dose efficiency in the phantom scans yielded no significant difference between the protocols.Up to 150 kg body weight, CT can be performed with the standard technique at 120 kVp with tube current modulation. In larger patients diagnostic image quality can only be achieved reliably with the dual source XXL mode, although at considerably increased calculated dose. However, standard conversion factors yield false high values so that the estimation of the biologically relevant equivalent dose is very difficult.


Assuntos
Absorciometria de Fóton/métodos , Algoritmos , Sobrepeso/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Gut ; 58(2): 241-8, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18852257

RESUMO

BACKGROUND AND AIMS: This prospective trial was designed to compare the performance characteristics of five different screening tests in parallel for the detection of advanced colonic neoplasia: CT colonography (CTC), colonoscopy (OC), flexible sigmoidoscopy (FS), faecal immunochemical stool testing (FIT) and faecal occult blood testing (FOBT). METHODS: Average risk adults provided stool specimens for FOBT and FIT, and underwent same-day low-dose 64-multidetector row CTC and OC using segmentally unblinded OC as the standard of reference. Sensitivities and specificities were calculated for each single test, and for combinations of FS and stool tests. CTC radiation exposure was measured, and patient comfort levels and preferences were assessed by questionnaire. RESULTS: 221 adenomas were detected in 307 subjects who completed CTC (mean radiation dose, 4.5 mSv) and OC; 269 patients provided stool samples for both FOBT and FIT. Sensitivities of OC, CTC, FS, FIT and FOBT for advanced colonic neoplasia were 100% (95% CI 88.4% to 100%), 96.7% (82.8% to 99.9%), 83.3% (95% CI 65.3% to 94.4%), 32% (95% CI 14.9% to 53.5) and 20% (95% CI 6.8% to 40.7%), respectively. Combination of FS with FOBT or FIT led to no relevant increase in sensitivity. 12 of 45 advanced adenomas were smaller than 10 mm. 46% of patients preferred CTC and 37% preferred OC (p<0.001). CONCLUSIONS: High-resolution and low-dose CTC is feasible for colorectal cancer screening and reaches sensitivities comparable with OC for polyps >5 mm. For patients who refuse full bowel preparation and OC or CTC, FS should be preferred over stool tests. However, in cases where stool tests are performed, FIT should be recommended rather than FOBT.


Assuntos
Adenoma/diagnóstico , Neoplasias Colorretais/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Colo/patologia , Pólipos do Colo/diagnóstico , Colonografia Tomográfica Computadorizada/métodos , Colonoscopia/métodos , Fezes/química , Feminino , Hemoglobinas/análise , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Sangue Oculto , Estudos Prospectivos , Reto/patologia , Tamanho da Amostra , Sensibilidade e Especificidade , Sigmoidoscopia/métodos , Gravação em Vídeo
3.
Eur Radiol ; 19(6): 1366-78, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19190917

RESUMO

The purpose of this study was to assess the diagnostic accuracy of whole-body MRI (WB-MRI) at 1.5 T or 3 T compared with FDG-PET-CT in the follow-up of patients suffering from colorectal cancer. In a retrospective study, 24 patients with a history of colorectal cancer and suspected tumour recurrence underwent FDG-PET-CT and WB-MRI with the use of parallel imaging (PAT) for follow-up. High resolution coronal T1w-TSE and STIR sequences at four body levels, HASTE imaging of the lungs, contrast-enhanced T1w- and T2w-TSE sequences of the liver, brain, abdomen and pelvis were performed, using WB-MRI at either 1.5 T (n = 14) or 3 T (n = 10). Presence of local recurrent tumour, lymph node involvement and distant metastatic disease was confirmed using radiological follow-up within at least 5 months as a standard of reference. Seventy seven malignant foci in 17 of 24 patients (71%) were detected with both WB-MRI and PET-CT. Both investigations concordantly revealed two local recurrent tumours. PET-CT detected significantly more lymph node metastases (sensitivity 93%, n = 27/29) than WB-MRI (sensitivity 63%, n = 18/29). PET-CT and WB-MRI achieved a similar sensitivity for the detection of organ metastases with 80% and 78%, respectively (37/46 and 36/46). WB-MRI detected brain metastases in one patient. One false-positive local tumour recurrence was indicated by PET-CT. Overall diagnostic accuracy for PET-CT was 91% (sensitivity 86%, specificity 96%) and 83% for WB-MRI (sensitivity 72%, specificity 93%), respectively. Examination time for WB-MRI at 1.5 T and 3 T was 52 min and 43 min, respectively; examination time for PET-CT was 103 min. Initial results suggest that differences in accuracy for local and distant metastases detection using FDG-PET-CT and WB-MRI for integrated screening of tumour recurrence in colorectal cancer depend on the location of the malignant focus. Our results show that nodal disease is better detected using PET-CT, whereas organ disease is depicted equally well by both investigations.


Assuntos
Neoplasias Colorretais/diagnóstico , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Phys Med Biol ; 53(2): 339-51, 2008 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-18184990

RESUMO

Input functions required for positron emission tomography (PET) tracer kinetic modeling are often obtained from arterial blood. In some situations, using short-lived radiotracers, e.g. [(15)O]water, rapid sample handling is required. A method used at several facilities is to pump blood through a detector system at a constant rate. We investigate the suitability of a commercial radiochromatography module (IN/US Posi-RAM) for this new use. The Posi-RAM consists of two 2.5 cm (length) x 2.5 cm (diameter) cylindrical bismuth germanate (BGO) detectors that can operate in coincidence mode. Arterial blood is transported through the system via a length of tubing with flow rate controlled by a peristalsis pump. A custom-counting loop and support frame were designed for the Posi-RAM for PET studies. System sensitivity was determined to be 1.1 x 10(4) cps/(MBq ml(-1)). Dead time as a function of count-rate was found to be less than 1% for concentrations below 3.5 MBq ml(-1), a range encompassing all human-study values. In a human study, the performance of the device was found to be similar to that of the facility's current blood monitor (Siemens Fluid Monitor). We conclude that the Posi-RAM has the necessary sensitivity and count-rate capabilities to be used as a real-time blood activity monitor.


Assuntos
Artérias/metabolismo , Análise Química do Sangue/instrumentação , Sangue/diagnóstico por imagem , Cromatografia/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Radiometria/instrumentação , Compostos Radiofarmacêuticos/sangue , Processamento de Sinais Assistido por Computador/instrumentação , Análise Química do Sangue/métodos , Cromatografia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Radioquímica/instrumentação , Radioquímica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Radiologe ; 48(2): 118-25, 2008 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-18231767

RESUMO

CT colonography (CTC) is also referred to as virtual colonoscopy and is being used with increasing frequency in radiological practice. While there are still no generally accepted, clear-cut indications for its use in mass colorectal cancer screening, there is evidence that this investigation is useful in patients in whom colonoscopy has not been successful or who have known stenotic lesions in the colon. Recent results of significant comparative studies of CTC and conventional colonoscopy will have some influence on the future place of CTC in screening for cancer of the bowel; they show the great potential of CT-aided bowel examination.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada , Programas de Rastreamento , Doenças do Colo/diagnóstico por imagem , Doenças do Colo/patologia , Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Colonoscopia , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Diagnóstico Diferencial , Humanos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/patologia , Estadiamento de Neoplasias , Aceitação pelo Paciente de Cuidados de Saúde , Doses de Radiação , Sensibilidade e Especificidade
6.
AJR Am J Roentgenol ; 187(3): 695-701, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16928932

RESUMO

OBJECTIVE: The purpose of our study was to evaluate the dose reduction potential of combined online (x- and y-axes) and topogram-based (l) X-ray tube current modulation in CT colonography in a screening population. MATERIALS AND METHODS: Eighty asymptomatic individuals underwent CT colonography screening for colon polyps. A 16-MDCT scanner (Somatom Sensation 16) was used. Forty patients were examined at 120 kVp and 120 effective mAs (supine) and 40 effective mAs (prone) using online x- and y-axis tube current modulation. Another 40 patients were scanned using combined x-, y-, and z-axis tube current modulation. Individual patient radiation exposure was determined using the dose-length product. Image noise was determined by Hounsfield unit measurements in the colonic lumen at four anatomic levels. Image quality was rated on a 5-point confidence scale by two independent reviewers. The unpaired Student's t test (for radiation dose, image noise) and Wilcoxon's test (for image quality) were used to test for statistically significant differences between these values. RESULTS: Radiation dose was significantly lower in the patient group scanned with x-, y-, and z-axis tube current modulation than in the group scanned with x- and y-axis tube current modulation (supine: 4.24 vs 6.50 mSv, p < 0.0001; prone: 1.61 vs 2.38 mSv, p < 0.0001). Radiation dose was reduced by 35% (supine) and 33% (prone). No statistically significant difference was seen in overall image noise (supine: 15.9 vs 16.3 H, p = 0.13; prone: 23.5 vs 24.8 H, p = 0.44) or image quality (supine: 4.6 vs 4.5, p = 0.62; prone: 3.5 vs 3.6, p = 0.54). CONCLUSION: Combined x-, y-, and z-axis tube current modulation leads to a significant reduction of radiation exposure in CT colonography without loss of image quality.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Idoso , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Radiometria , Sensibilidade e Especificidade , Software
8.
Am J Cardiol ; 88(3): 219-23, 2001 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-11472697

RESUMO

The aim of this study was to investigate the reliability of calcium scoring (CS) and electron beam computed tomographic angiography (EBCTA) as a noninvasive tool in the diagnosis of coronary artery disease (CAD): 93 consecutive patients (aged 59 +/- 9 years) with symptoms suspicious for CAD underwent CS. In 87 of these subjects, an additional EBCTA investigation was performed. Using receiver-operating characteristic curve analysis, we determined a calcium score cut point providing an overall sensitivity of 80% and a specificity of 72% in detecting patients with CAD. For clinical purposes the use of cut points is difficult. We therefore determined score ranges providing >80% specificity (high score range) and >85% sensitivity (low score range) and determined the scores between these ranges as equivocal borderline scores. Calculated on a per-segment basis in assessable proximal and midcoronary segments, the sensitivity for detecting coronary stenoses >50% was 78%, and the specificity was 93%. Thus, 32 of 44 patients with significant CAD and 24 of 49 patients without CAD were correctly classified. The combination of CS and EBCTA predicted CAD in 77% (72 of 93) of patients. No or low calcium scores provided high specificity for ruling out CAD. The addition of EBCTA in those patients improved sensitivity. In patients with high calcium scores, accuracy of EBCTA was not significantly different from CS alone (72% vs 83%), whereas in patients with borderline scores it was significantly superior (80% vs 58%, p <0.03). Thus, the complementary use of CS and EBCTA appears beneficial, particularly in patients with borderline scores, and could improve sensitivity in the low score range. In the presence of high scores, no major diagnostic gain from an additional EBCTA versus CS alone could be observed.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Valores de Referência , Reprodutibilidade dos Testes
9.
Magn Reson Imaging ; 12(8): 1167-74, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7854023

RESUMO

A new method for the ultrafast generation of diffusion-weighted images is reported. The technique combines a quick echo split NMR imaging sequence with the principle of Stejskal and Tanner. It allows to determine the diffusion constant with nearly the same accuracy as the conventional spin-echo technique, requiring only a fraction of the time. The determined values for water doped with 1 g Cu(NO3)2 per liter of H2O and pure acetone were Dwater = (1.95 +/- 0.02) x 10(-9) m2/s and Dacetone = (4.05 +/- 0.02) x 10(-9) m2/s at 18.5 degrees C. They are in good agreement both with literature and our own reference measurements using a diffusion-weighted spin-echo sequence. In addition, the temperature dependence of Dwater was measured in the range of 18.5-45.9 degrees C and a good correspondence with reported data was found.


Assuntos
Espectroscopia de Ressonância Magnética/métodos
10.
Eur J Radiol ; 36(2): 97-103, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11116173

RESUMO

Multidector-row CT (MDCT) with retrospective ECG gating allows scanning the entire heart with 1.25 mm slice thickness and 250 ms effective exposure time within 35 s investigation time. The resulting images allow for an accurate high-resolution assessment of morphological detail of both the coronary arteries and the cardiac chambers. Performing a contrast-enhanced MDCT angiography (MD-CTA) in addition to a non-enhanced scan for the detection and quantification of coronary calcifications may be indicated in patients with atypical chest pain and in young patients with high cardiovascular risk. This group of patients may show non-calcified plaques as the first sign of their coronary artery disease. As the proximal part of the coronary arteries is well displayed by MD-CTA it also helps to delineate the course in anomalous coronary vessels. Additional information is drawn from the preoperative use of MD-CTA do determine the distance of the left internal mammarian artery to the left anterior descending coronary artery prior to minimal invasive bypass grafting. Additional indications for MD-CTA are the non-invasive follow up after venous bypass grafting, PTCA, and coronary stent interventions. MD-CTA allows following the course of the coronary vessels to the level of third generation coronary segmental arteries. A definite diagonis to rule out coronary artery disease can be reliably made in vessels with a diameter of 1.5 mm or greater. With MDCT a number of different atherosclerotic changes can be observed in diseased coronary arteries. Non-stenotic lesions may show tiny calcifications surrounded by large areas of irregularly distributed soft tissue. Calcifications in this type of atherosclerotic coronary artery wall changes appear as 'the tip of iceberg'. Heavy calcifications usually tend to be non-stenotic because of vessel remodelling resulting in a widening of the coronary vessel lumen. Therefore, heavy calcifications appear to ack like an 'internal stent' for a coronary vessel segment. Humps of soft tissue either with or without calcifications are more likely to cause significant coronary artery disease and correlate with stenoses of >50% on selective coronary catheter. These humps consist of well-defined soft tissue in the coronary artery wall. The density of this soft tissue may vary between 30-70 HU. In cases where a coronary vessel is occluded by thrombotic material, a typical sign is found with enlargement of the coronary vessel, a hypodense center and a hyperdense rim. Vessel occlusion without thrombus may also appear within a collapsed and dense lumen. In addition to the investigation of the coronary arteries, CTA with MDCT is well suited to assess the presence and morphology of myocardial scars and aneurysms, intracardial tumors and thrombi.


Assuntos
Calcinose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária , Ecocardiografia , Humanos
11.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(1 Pt 2): 016412, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11800795

RESUMO

Ultrashort bursts of silicon K alpha x-ray radiation from femtosecond-laser-produced plasmas have been generated. A cross-correlation measurement employing a laser-triggered ultrafast structural change of a CdTe crystal layer (320 nm) shows a K alpha pulse duration between 200 fs and 640 fs. This result is corroborated by particle in cell simulations combined with a Monte-Carlo electron stopping code and calculations on the structural changes of the crystal lattice.

12.
Rofo ; 176(11): 1566-75, 2004 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-15497074

RESUMO

Electron beam tomography (EBT) has been scientifically evaluated to a much lesser degree for non-cardiac indications than for cardiac purposes. Therefore, four groups of investigators in Berlin (2), Mannheim and Munchen, which were supported by the Deutsche Forschungsgemeinschaft (DFG), included applications outside the heart in their evaluation of EBT technology. EBT has proven useful to look for pulmonary embolism and to assess other vessels (aorta, aortic branches, and intracranial arteries). Imaging of the lung parenchyma benefits from its intrinsic high contrast and from the fast data acquisition of EBT. Limited photon efficiency, higher radiation exposure, increased noise levels and other artifacts, however, markedly reduce the value of EBT for imaging of low contrast objects compared to conventional spiral CT and multislice CT (MSCT), compromising, in particular, the morphologic depiction of parenchymal abdominal organs and the brain. Consequently, scientific studies to further evaluate EBT for scanning of the brain and parenchymal abdominal organs were not pursued. Radiation exposure for non-cardiac EBT studies is up to three times higher than that for respective spiral CT studies, and in children EBT can only be advocated in select cases. Radiation exposure for the various prospectively triggered cardiac examination protocols of EBT is lower than that for conventional coronary angiography. Radiation exposure in cardiac multislice CT exceeds severalfold that of EBT, but the dose efficiency of EBT and MSCT are similar due to higher spatial resolution and less image noise of MSCT. In addition, modifications of MSCT (ECG pulsing) can further reduce radiation exposure to the level of EBT. Technical improvements of the EBT successor scanner "e-Speed" enable faster data acquisition at higher spatial resolution. Within comparative studies, the "e-Speed" will have to prove its value and competitiveness, particularly in comparison with multislice CT. After profound scientific assessment in a multicenter evaluation supported by the Deutsche Forschungsgemeinschaft (DFG) and regardless of the specific suitability of electron beam tomography for various cardiac and some non-cardiac indications, the investigators unanimously find the electron beam tomograph Evolution C150 XP not suitable as a whole body CT scanner.


Assuntos
Radiografia Abdominal , Radiografia Torácica , Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X , Fatores Etários , Idoso , Pesquisa Biomédica , Criança , Angiografia Coronária , Feminino , Alemanha , Cardiopatias/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Estudos Multicêntricos como Assunto , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada Espiral/efeitos adversos , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Doenças Vasculares/diagnóstico por imagem
13.
Rofo ; 176(1): 27-36, 2004 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-14712404

RESUMO

Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages, not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Angioplastia Coronária com Balão , Calcinose/diagnóstico por imagem , Cateterismo Cardíaco , Doença das Coronárias/diagnóstico , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/diagnóstico por imagem , Coração/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Stents
14.
An Sist Sanit Navar ; 27(1): 63-72, 2004.
Artigo em Espanhol | MEDLINE | ID: mdl-15146206

RESUMO

Since the introduction of last generation multislice MSCT systems and the development of simultaneous electrocardiographic-tracing image acquisition and retrospective reconstruction techniques into clinical routine, cardiac MSCT has been considered a very useful non-invasive technique for the study of cardiac pathology in the daily clinical practice. One of the main clinical applications of this diagnostic technique is the evaluation of the coronary arteries including detection and quantification of coronary calcium, multislice CT coronary angiography (anatomy, anatomical variants and anomalies of the origin and course), the angiographic evaluation of the patency of aortocoronary by-pass grafts and coronary stents, and plaque characterization. The new reconstruction and postprocessing programs allow to obtain, in addition, parameters of myocardial morphology and contraction and cardiac function. Other clinical applications include the characterization of cardiac masses and the evaluation of the pericardium.


Assuntos
Angiografia Coronária/métodos , Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ensaios Clínicos como Assunto , Doença das Coronárias/diagnóstico por imagem , Coração/anatomia & histologia , Neoplasias Cardíacas/diagnóstico por imagem , Humanos
15.
MMW Fortschr Med ; 143(16): 30-2, 2001 Apr 19.
Artigo em Alemão | MEDLINE | ID: mdl-11367989

RESUMO

The short imaging time of 1/4 second, renders the new generation of multiple-slice spiral CT devices with ECG gating enables the investigation of the heart without disturbing motion artefacts. With this method, calcifications of the coronary arteries can be detected or excluded. Certain amounts of coronary "chalk" in asymptomatic patients with risk factors point to coronary artery disease and thus a need to modulate the risk factors. With the aid of intravenous injection of contrast medium during the examination, non-calcified plaques in the coronary arteries can also be visualized. A limiting factor is that the patient's heart rate should not exceed 60 beats per minute. Indications for this examination are visualization of coronary vessels with the aim of excluding coronary artery disease, pre-operative planning and monitoring of bypass vessels, and non-invasive follow-up after PTCA and stenting.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Trombose Coronária/diagnóstico por imagem , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco
16.
MMW Fortschr Med ; 146(49): 38, 40-1, 2004 Dec 02.
Artigo em Alemão | MEDLINE | ID: mdl-15646715

RESUMO

Provided that adequate image quality is achieved, contrast-enhanced multislice spiral computed tomography enables the identification and characterisation of calcified and non-calcified coronary plaques. This is a major advance in the non-invasive assessment of coronary atherosclerosis that promises to open up new opportunities for a better understanding and risk stratification of this condition, with visualization of non-calcified hypodense lesions in particular appearing to be of prognostic importance. Current limitations of the technique relating mainly to temporal and spatial resolution may be eliminated by the introduction of a new generation of scanners enabling 64 slices and more.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Espiral , Angina Pectoris/diagnóstico por imagem , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia de Intervenção
17.
Clin Hemorheol Microcirc ; 55(1): 183-91, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23455839

RESUMO

PURPOSE: To evaluate the feasibility of the classification of endoleaks following endovascular aortic aneurysm repair using the time-to-peak of the contrast agent in CEUS examinations. MATERIAL AND METHODS: In this retrospective study, a cohort of 171 patients with a total of 489 CEUS follow-up examinations after EVAR were included. In 254 of the 489 examinations, an endoleak was seen and the time-to-peak was measured in seconds. Existence of an endoleak was confirmed by CT as the gold standard. RESULTS: We evaluated 254 CEUS video sequences showing an endoleak out of a total of 489 examinations. Kruskal-Wallis test revealed with p = 0.001 differences between the single endoleak types based on the time to peak. Correction after Bonferroni showed significant differences between type Ia compared to Ib and to IIa over inferior mesenteric artery (IMA) and IIa over lumbar artery (LA). There are also disparities between type Ib and type IIa IMA and type III, furthermore between type IIa IMA compared to IIa LA and type III as well as type IIa LA matched to type III. CONCLUSION: CEUS is an important method for the follow-up after EVAR. The time-to-peak does not seem to be a useful additional feature in classifying endoleaks, although there are differences between the time-to-peak of the single endoleak types and it is possible to make an order of the different endoleak types referring to the mean values.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Endoleak/classificação , Aumento da Imagem/métodos , Ultrassonografia de Intervenção/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Estudos de Coortes , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Radiografia , Estudos Retrospectivos
18.
Eur J Radiol ; 82(6): 951-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23518148

RESUMO

PURPOSE: Purpose of the study was to compare radiological treatment response according to RECIST, Choi and volumetry in GIST-patients under 2nd-line-sunitinib-therapy and to correlate the results of treatment response assessment with disease-specific survival (DSS). PATIENTS AND METHODS: 20 patients (mean: 60.7 years; 12 male/8 female) with histologically proven GIST underwent baseline-CT of the abdomen under imatinib and follow-up-CTs 3 months and 1 year after change to sunitinib. 68 target lesions (50 hepatic, 18 extrahepatic) were investigated. Therapy response (partial response (PR), stable disease (SD), progressive disease (PD)) was evaluated according to RECIST, Choi and volumetric criteria. Response according to the different assessment systems was compared and correlated to the DSS of the patients utilizing Kaplan-Meier statistics. RESULTS: The mean DSS (in months) of the response groups 3 months after therapy change was: RECIST: PR (0/20); SD (17/20): 30.4 (months); PD (3/20) 11.6. Choi: PR (10/20) 28.6; SD (8/20) 28.1; PD (2/20) 13.5. Volumetry: PR (4/20) 29.6; SD (11/20) 29.7; PD (5/20) 17.2. Response groups after 1 year of sunitinib showed the following mean DSS: RECIST: PR (3/20) 33.6; SD (9/20) 29.7; PD (8/20) 20.3. Choi: PR (10/20) 21.5; SD (4/20) 42.9; PD (6/20) 23.9. Volumetry: PR (6/20) 27.3; SD (5/20) 38.5; PD (9/20) 19.3. CONCLUSION: One year after modification of therapy, only partial response according to RECIST indicated favorable survival in patients with GIST. The value of alternate response assessment strategies like Choi criteria for prediction of survival in molecular therapy still has to be demonstrated.


Assuntos
Tumores do Estroma Gastrointestinal , Imageamento Tridimensional/métodos , Indóis/uso terapêutico , Neoplasias Hepáticas , Neoplasias Peritoneais , Pirróis/uso terapêutico , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Algoritmos , Antineoplásicos/uso terapêutico , Intervalo Livre de Doença , Feminino , Tumores do Estroma Gastrointestinal/diagnóstico , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/secundário , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Neoplasias Peritoneais/diagnóstico , Neoplasias Peritoneais/tratamento farmacológico , Neoplasias Peritoneais/secundário , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sunitinibe , Análise de Sobrevida , Resultado do Tratamento , Carga Tumoral , Adulto Jovem
20.
Radiologe ; 48(9): 850-6, 2008 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-18806986

RESUMO

For patients with metastasized renal cell carcinoma (RCC), imaging techniques are of great importance. Currently, therapy widely relies on antiangiogenic factors, which frequently lead to relatively subtle changes in the size of lesions. From this aspect the commonly used RECIST criteria (response evaluation criteria in solid tumors) must be considered as imprecise for the evaluation of the response to therapy. This article gives a review on new software-based volumetric methods, which allow therapy-induced changes in the size of metastases from RCC to be detected with higher sensitivity and reproducibility. A comparison of RECIST and volumetry was carried out with data from patients with metastasized RCC to demonstrate the higher sensitivity of the 3D volumetric procedure.


Assuntos
Algoritmos , Carcinoma de Células Renais/diagnóstico , Carcinoma de Células Renais/secundário , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Renais/diagnóstico , Software , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA