Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
Diagnostics (Basel) ; 12(4)2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35453846

RESUMO

The purpose of this study was to determine the observer agreement in assessing the enhancement pattern of suspicious breast lesions with contrast-enhanced ultrasound (CEUS) using high and low frequency transducers. Methods: This prospective study included 70 patients with suspicious breast lesions detected at mammography and/or ultrasound and classified according to the American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BI-RADS) in 4A, 4B, 4C, or 5, who underwent CEUS examinations between October 2020 and August 2021. Results: Participants' ages ranged from 28 to 83 years (48.5 + 6.36, mean age + SD). We obtained a substantial agreement for the first reader (kappa = 0.614, p < 0.001) and a perfect agreement for the second and third reader (kappa = 1, p < 0.001) between the two transducers for the uptake pattern. A moderate agreement for the second and third reader (kappa = 0.517 and 0.538, respectively, p < 0.001) and only a fair agreement (kappa = 0.320, p < 0.001) in the case of the first reader for the perilesional enhancement was observed. We obtained an excellent inter-observer agreement (Cronbach's Alpha coefficient = 0.960, p < 0.001) for the degree of enhancement, a good inter-observer agreement for the uptake pattern and perilesional enhancement (Cronbach's Alpha coefficient = 0.831 and 0.853, respectively, p < 0.001), and a good and acceptable inter-observer agreement for internal homogeneity, perfusion defects and margins of the lesions (Cronbach's Alpha coefficient = 0.703, 0.703 and 0.792, respectively, p < 0.001) concerning the evaluation of breast lesions with the linear-array transducer. Conclusions: The evaluation of suspicious breast lesions by three experts with high-frequency linear-array transducer and low-frequency convex-array transducer was comparable in terms of uptake pattern and perilesional enhancement. The agreement regarding the evaluation of the degree of enhancement, the internal homogeneity, and the perfusion defects varied between fair and substantial. For all CEUS characteristics, the inter-observer agreement was superior for linear-array transducer, which leads to more a homogeneous and reproducible interpretation.

3.
Diagnostics (Basel) ; 12(10)2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36292162

RESUMO

Myopericytoma is a rare vessel wall tumor, a subtype of hemangiopericytoma that usually develops subcutaneously. Intravascular myopericytoma is a rarer subtype, with only few cases reported in the literature and even fewer with imaging modalities included. We report the case of a 36-year-old man who was referred to our institution with a painless, palpable mass in the right arm and was evaluated with MRI, grey-scale and Doppler-mode ultrasound. Tumor histopathology and imaging characteristics are presented together with the role that each imaging modality played in the management of the patient.

4.
Diagnostics (Basel) ; 12(2)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35204550

RESUMO

The purpose of the present study was to evaluate the value of full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in the diagnosis of breast cancer compared to FFDM associated with digital breast tomosynthesis (DBT). Methods: This retrospective study included 50 female patients with a denser framework of connective tissue fibers, characteristic of young women who underwent FFDM, DBT, handheld ultrasound (HHUS), and ABUS between January 2017 and October 2018. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of FFDM+ABUS were 81.82% (95% CI [48.22-97.72]), 89.74% (95% CI [75.78-97.13]), 69.23% (95% CI [46.05-85.57]), 94.59% (95% CI [83.26-98.40]), and 88% (95% CI [75.69-95.47]), while for FFDM+DBT, the values were as follows: 91.67% (95% CI [61.52-99.79]), 71.79% (95% CI [55.13-85.00]), 50% (95% CI [37.08-62.92]), 96.55% (95% CI [80.93-99.46]), 76.47% (95% CI [62.51-87.21]). We found an almost perfect agreement between the two readers regarding FFDM associated with ABUS, and substantial agreement regarding FFDM+DBT, with a kappa coefficient of 0.896 and 0.8, respectively; p < 0.001. Conclusions: ABUS and DBT are suitable as additional diagnostic imaging techniques to FFDM in women at an intermediate risk of developing breast cancer through the presence of dense breast tissue. In this study, DBT reduced the number of false negative results, while the use of ABUS resulted in an increase in specificity.

5.
Cancers (Basel) ; 14(16)2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-36010897

RESUMO

The purpose of this study was to evaluate the diagnostic performance of radiomic features extracted from standardized hybrid contrast-enhanced ultrasound (CEUS) data for the assessment of hormone receptor status, human epidermal growth factor receptor 2 (HER2) status, tumor grade and Ki-67 in patients with primary breast cancer. METHODS: This prospective study included 72 patients with biopsy-proven breast cancer who underwent CEUS examinations between October 2020 and September 2021. RESULTS: A radiomic analysis found the WavEnHH_s_4 parameter as an independent predictor associated with the HER2+ status with 76.92% sensitivity, and 64.41% specificity and a prediction model that could differentiate between the HER2 entities with 76.92% sensitivity and 84.75% specificity. The RWavEnLH_s-4 parameter was an independent predictor for estrogen receptor (ER) status with 55.93% sensitivity and 84.62% specificity, while a prediction model (RPerc01, RPerc10 and RWavEnLH_s_4) could differentiate between the progesterone receptor (PR) status with 44.74% sensitivity and 88.24% specificity. No texture parameter showed statistically significant results at the univariate analysis when comparing the Nottingham grade and the Ki-67 status. CONCLUSION: Our preliminary data indicate a potential that hybrid CEUS radiomic features allow the discrimination between breast cancers of different receptor and HER2 statuses with high specificity. Hybrid CEUS radiomic features might have the potential to provide a noninvasive, easily accessible and contrast-agent-safe method to assess tumor biology before and during treatment.

6.
Diagnostics (Basel) ; 12(1)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35054325

RESUMO

We report a case of a 52-year-old woman who was referred to our institution with a superior vena cava syndrome and was investigated through echocardiography, CT and MRI revealing a well-defined, encapsulated pericardial mass. The pathology, correlated with the immunohistochemical analysis, concluded it was an extremely rare primary pericardial synovial sarcoma. The patient underwent surgery and chemotherapy with a 16-month disease-free survival and passed away after a contralateral aggressive relapse. Moreover, we discuss the role of each imaging modality together with their pericardial synovial sarcoma reported features.

7.
Cancers (Basel) ; 14(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36497347

RESUMO

Aim: To evaluate the role of MR relaxometry and derived proton density analysis in the prediction of early treatment response after two cycles of neoadjuvant therapy (NAT), in patients with breast cancer. Methods: This was a prospective study that included 59 patients with breast cancer, who underwent breast MRI prior (MRI1) and after two cycles of NAT (MRI2). The MRI1 included a sequential acquisition with five different TE's (50, 100, 150, 200 and 250 ms) and a TR of 5000 ms. Post-processing was used to obtain the T2 relaxometry map from the MR acquisition. The tumor was delineated and seven relaxometry and proton density parameters were extracted. Additional histopathology data, T2 features and ADC were included. The response to NAT was reported based on the MRI2 as responders: partial response (>30% decreased size) and complete response (no visible tumor stable disease (SD); and non-responders: stable disease or progression (>20% increased size). Statistics was done using Medcalc software. Results: There were 50 (79.3%) patients with response and 13 (20.7%) non-responders to NAT. Age, histologic type, "in situ" component, tumor grade, estrogen and progesterone receptors, ki67% proliferation index and HER2 status were not associated with NAT response (all p > 0.05). The nodal status (N) 0 was associated with early response, while N2 was associated with non-response (p = 0.005). The tumor (T) and metastatic (M) stage were not statistically significant associated with response (p > 0.05). The margins, size and ADC values were not associated with NAT response (p-value > 0.05). The T2 min relaxometry value was associated with response (p = 0.017); a cut-off value of 53.58 obtained 86% sensitivity (95% CI 73.3−94.2), 69.23 specificity (95% CI 38.6−90.9), with an AUC = 0.715 (p = 0.038). The combined model (T2 min and N stage) achieved an AUC of 0.826 [95% CI: 0.66−0.90, p-value < 0.001]. Conclusions: MR relaxometry may be a useful tool in predicting early treatment response to NAT in breast cancer patients.

8.
J Pers Med ; 11(2)2021 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-33573122

RESUMO

The aim of this paper is to highlight the role of contrast-enhanced ultrasound in breast cancer in terms of diagnosis, staging and follow-up of the post-treatment response. Contrast-enhanced ultrasound (CEUS) is successfully used to diagnose multiple pathologies and has also clinical relevance in breast cancer. CEUS has high accuracy in differentiating benign from malignant lesions by analyzing the enhancement characteristics and calculating the time-intensity curve's quantitative parameters. It also has a significant role in axillary staging, especially when the lymph nodes are not suspicious on clinical examination and have a normal appearance on gray-scale ultrasound. The most significant clinical impact consists of predicting the response to neoadjuvant chemotherapy, which offers the possibility of adjusting the therapy by dynamically evaluating the patient. CEUS is a high-performance, feasible, non-irradiating, accessible, easy-to-implement imaging method and has proven to be a valuable addition to breast ultrasound.

9.
J Pers Med ; 11(8)2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34442347

RESUMO

Automated breast ultrasound (ABUS) is an ultrasound technique that tends to be increasingly used as a supplementary technique in the evaluation of patients with dense glandular breasts. Patients with dense breasts have an increased risk of developing breast cancer compared to patients with fatty breasts. Furthermore, for this group of patients, mammography has a low sensitivity in detecting breast cancers, especially if it is not associated with architectural distortion or calcifications. ABUS is a standardized examination with many advantages in both screening and diagnostic settings: it increases the detection rate of breast cancer, improves the workflow, and reduces the examination time. On the other hand, like any imaging technique, ABUS has disadvantages and even some limitations. Many disadvantages can be diminished by additional attention and training. Disadvantages regarding image acquisition are the inability to assess the axilla, the vascularization, and the elasticity of a lesion, while concerning the interpretation, the disadvantages are the artifacts due to poor positioning, lack of contact, motion or lesion related. This article reviews and discusses the indications, the advantages, and disadvantages of the method and also the sources of error in the ABUS examination.

10.
Diagnostics (Basel) ; 11(7)2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34359332

RESUMO

BACKGROUND: The purpose of this study was to assess the effectiveness of the radiomic analysis of contrast-enhanced spectral mammography (CESM) in discriminating between breast cancers and background parenchymal enhancement (BPE). METHODS: This retrospective study included 38 patients that underwent CESM examinations for clinical purposes between January 2019-December 2020. A total of 57 malignant breast lesions and 23 CESM examinations with 31 regions of BPE were assessed through radiomic analysis using MaZda software. The parameters that demonstrated to be independent predictors for breast malignancy were exported into the B11 program and a k-nearest neighbor classifier (k-NN) was trained on the initial groups of patients and was tested using a validation group. Histopathology results obtained after surgery were considered the gold standard. RESULTS: Radiomic analysis found WavEnLL_s_2 parameter as an independent predictor for breast malignancies with a sensitivity of 68.42% and a specificity of 83.87%. The prediction model that included CH1D6SumAverg, CN4D6Correlat, Kurtosis, Perc01, Perc10, Skewness, and WavEnLL_s_2 parameters had a sensitivity of 73.68% and a specificity of 80.65%. Higher values were obtained of WavEnLL_s_2 and the prediction model for tumors than for BPEs. The comparison between the ROC curves provided by the WaveEnLL_s_2 and the entire prediction model did not show statistically significant results (p = 0.0943). The k-NN classifier based on the parameter WavEnLL_s_2 had a sensitivity and specificity on training and validating groups of 71.93% and 45.16% vs. 60% and 44.44%, respectively. CONCLUSION: Radiomic analysis has the potential to differentiate CESM between malignant lesions and BPE. Further quantitative insight into parenchymal enhancement patterns should be performed to facilitate the role of BPE in personalized clinical decision-making and risk assessment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA