Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(7): 4379-4392, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38150075

RESUMO

OBJECTIVES: To quantify regional manifestations related to COPD as anomalies from a modeled distribution of normal-appearing lung on chest CT using a deep learning (DL) approach, and to assess its potential to predict disease severity. MATERIALS AND METHODS: Paired inspiratory/expiratory CT and clinical data from COPDGene and COSYCONET cohort studies were included. COPDGene data served as training/validation/test data sets (N = 3144/786/1310) and COSYCONET as external test set (N = 446). To differentiate low-risk (healthy/minimal disease, [GOLD 0]) from COPD patients (GOLD 1-4), the self-supervised DL model learned semantic information from 50 × 50 × 50 voxel samples from segmented intact lungs. An anomaly detection approach was trained to quantify lung abnormalities related to COPD, as regional deviations. Four supervised DL models were run for comparison. The clinical and radiological predictive power of the proposed anomaly score was assessed using linear mixed effects models (LMM). RESULTS: The proposed approach achieved an area under the curve of 84.3 ± 0.3 (p < 0.001) for COPDGene and 76.3 ± 0.6 (p < 0.001) for COSYCONET, outperforming supervised models even when including only inspiratory CT. Anomaly scores significantly improved fitting of LMM for predicting lung function, health status, and quantitative CT features (emphysema/air trapping; p < 0.001). Higher anomaly scores were significantly associated with exacerbations for both cohorts (p < 0.001) and greater dyspnea scores for COPDGene (p < 0.001). CONCLUSION: Quantifying heterogeneous COPD manifestations as anomaly offers advantages over supervised methods and was found to be predictive for lung function impairment and morphology deterioration. CLINICAL RELEVANCE STATEMENT: Using deep learning, lung manifestations of COPD can be identified as deviations from normal-appearing chest CT and attributed an anomaly score which is consistent with decreased pulmonary function, emphysema, and air trapping. KEY POINTS: • A self-supervised DL anomaly detection method discriminated low-risk individuals and COPD subjects, outperforming classic DL methods on two datasets (COPDGene AUC = 84.3%, COSYCONET AUC = 76.3%). • Our contrastive task exhibits robust performance even without the inclusion of expiratory images, while voxel-based methods demonstrate significant performance enhancement when incorporating expiratory images, in the COPDGene dataset. • Anomaly scores improved the fitting of linear mixed effects models in predicting clinical parameters and imaging alterations (p < 0.001) and were directly associated with clinical outcomes (p < 0.001).


Assuntos
Aprendizado Profundo , Doença Pulmonar Obstrutiva Crônica , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Idoso , Valor Preditivo dos Testes , Pulmão/diagnóstico por imagem , Estudos de Coortes
2.
Eur Radiol ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345607

RESUMO

OBJECTIVES: A prospective, multi-centre study to evaluate concordance of morphologic lung MRI and CT in chronic obstructive pulmonary disease (COPD) phenotyping for airway disease and emphysema. METHODS: A total of 601 participants with COPD from 15 sites underwent same-day morpho-functional chest MRI and paired inspiratory-expiratory CT. Two readers systematically scored bronchial wall thickening, bronchiectasis, centrilobular nodules, air trapping and lung parenchyma defects in each lung lobe and determined COPD phenotype. A third reader acted as adjudicator to establish consensus. Inter-modality and inter-reader agreement were assessed using Cohen's kappa (im-κ and ir-κ). RESULTS: The mean combined MRI score for bronchiectasis/bronchial wall thickening was 4.5/12 (CT scores, 2.2/12 for bronchiectasis and 6/12 for bronchial wall thickening; im-κ, 0.04-0.3). Expiratory right/left bronchial collapse was observed in 51 and 47/583 on MRI (62 and 57/599 on CT; im-κ, 0.49-0.52). Markers of small airways disease on MRI were 0.15/12 for centrilobular nodules (CT, 0.34/12), 0.94/12 for air trapping (CT, 0.9/12) and 7.6/12 for perfusion deficits (CT, 0.37/12 for mosaic attenuation; im-κ, 0.1-0.41). The mean lung defect score on MRI was 1.3/12 (CT emphysema score, 5.8/24; im-κ, 0.18-0.26). Airway-/emphysema/mixed COPD phenotypes were assigned in 370, 218 and 10 of 583 cases on MRI (347, 218 and 34 of 599 cases on CT; im-κ, 0.63). For all examined features, inter-reader agreement on MRI was lower than on CT. CONCLUSION: Concordance of MRI and CT for phenotyping of COPD in a multi-centre setting was substantial with variable inter-modality and inter-reader concordance for single diagnostic key features. CLINICAL RELEVANCE STATEMENT: MRI of lung morphology may well serve as a radiation-free imaging modality for COPD in scientific and clinical settings, given that its potential and limitations as shown here are carefully considered. KEY POINTS: • In a multi-centre setting, MRI and CT showed substantial concordance for phenotyping of COPD (airway-/emphysema-/mixed-type). • Individual features of COPD demonstrated variable inter-modality concordance with features of pulmonary hypertension showing the highest and bronchiectasis showing the lowest concordance. • For all single features of COPD, inter-reader agreement was lower on MRI than on CT.

3.
Eur Respir J ; 62(4)2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37802631

RESUMO

BACKGROUND: Screening for lung cancer with low radiation dose computed tomography has a strong evidence base, is being introduced in several European countries and is recommended as a new targeted cancer screening programme. The imperative now is to ensure that implementation follows an evidence-based process that will ensure clinical and cost effectiveness. This European Respiratory Society (ERS) task force was formed to provide an expert consensus for the management of incidental findings which can be adapted and followed during implementation. METHODS: A multi-European society collaborative group was convened. 23 topics were identified, primarily from an ERS statement on lung cancer screening, and a systematic review of the literature was conducted according to ERS standards. Initial review of abstracts was completed and full text was provided to members of the group for each topic. Sections were edited and the final document approved by all members and the ERS Science Council. RESULTS: Nine topics considered most important and frequent were reviewed as standalone topics (interstitial lung abnormalities, emphysema, bronchiectasis, consolidation, coronary calcification, aortic valve disease, mediastinal mass, mediastinal lymph nodes and thyroid abnormalities). Other topics considered of lower importance or infrequent were grouped into generic categories, suitable for general statements. CONCLUSIONS: This European collaborative group has produced an incidental findings statement that can be followed during lung cancer screening. It will ensure that an evidence-based approach is used for reporting and managing incidental findings, which will mean that harms are minimised and any programme is as cost-effective as possible.


Assuntos
Neoplasias Pulmonares , Guias de Prática Clínica como Assunto , Humanos , Detecção Precoce de Câncer/métodos , Etiquetas de Sequências Expressas , Achados Incidentais , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
4.
Eur Radiol ; 33(7): 5077-5086, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36729173

RESUMO

This statement from the European Society of Thoracic imaging (ESTI) explains and summarises the essentials for understanding and implementing Artificial intelligence (AI) in clinical practice in thoracic radiology departments. This document discusses the current AI scientific evidence in thoracic imaging, its potential clinical utility, implementation and costs, training requirements and validation, its' effect on the training of new radiologists, post-implementation issues, and medico-legal and ethical issues. All these issues have to be addressed and overcome, for AI to become implemented clinically in thoracic radiology. KEY POINTS: • Assessing the datasets used for training and validation of the AI system is essential. • A departmental strategy and business plan which includes continuing quality assurance of AI system and a sustainable financial plan is important for successful implementation. • Awareness of the negative effect on training of new radiologists is vital.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiologia/métodos , Radiologistas , Radiografia Torácica , Sociedades Médicas
5.
Eur Radiol ; 32(3): 1879-1890, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34553255

RESUMO

OBJECTIVES: Pulmonary perfusion abnormalities are prevalent in patients with chronic obstructive pulmonary disease (COPD), are potentially reversible, and may be associated with emphysema development. Therefore, we aimed to evaluate the clinical meaningfulness of perfusion defects in percent (QDP) using DCE-MRI. METHODS: We investigated a subset of baseline DCE-MRIs, paired inspiratory/expiratory CTs, and pulmonary function testing (PFT) of 83 subjects (age = 65.7 ± 9.0 years, patients-at-risk, and all GOLD groups) from one center of the "COSYCONET" COPD cohort. QDP was computed from DCE-MRI using an in-house developed quantification pipeline, including four different approaches: Otsu's method, k-means clustering, texture analysis, and 80th percentile threshold. QDP was compared with visual MRI perfusion scoring, CT parametric response mapping (PRM) indices of emphysema (PRMEmph) and functional small airway disease (PRMfSAD), and FEV1/FVC from PFT. RESULTS: All QDP approaches showed high correlations with the MRI perfusion score (r = 0.67 to 0.72, p < 0.001), with the highest association based on Otsu's method (r = 0.72, p < 0.001). QDP correlated significantly with all PRM indices (p < 0.001), with the strongest correlations with PRMEmph (r = 0.70 to 0.75, p < 0.001). QDP was distinctly higher than PRMEmph (mean difference = 35.85 to 40.40) and PRMfSAD (mean difference = 15.12 to 19.68), but in close agreement when combining both PRM indices (mean difference = 1.47 to 6.03) for all QDP approaches. QDP correlated moderately with FEV1/FVC (r = - 0.54 to - 0.41, p < 0.001). CONCLUSION: QDP is associated with established markers of disease severity and the extent corresponds to the CT-derived combined extent of PRMEmph and PRMfSAD. We propose to use QDP based on Otsu's method for future clinical studies in COPD. KEY POINTS: • QDP quantified from DCE-MRI is associated with visual MRI perfusion score, CT PRM indices, and PFT. • The extent of QDP from DCE-MRI corresponds to the combined extent of PRMEmph and PRMfSAD from CT. • Assessing pulmonary perfusion abnormalities using DCE-MRI with QDP improved the correlations with CT PRM indices and PFT compared to the quantification of pulmonary blood flow and volume.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Idoso , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Perfusão , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
Radiologe ; 62(2): 149-157, 2022 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-35006315

RESUMO

BACKGROUND: Even after more than 100 years, the chest X­ray is still an important technique to detect important pathological changes of lungs, heart and vessels in a fast and low-dose manner. For the German-speaking regions, there are only recommendations available published by the "Ständigen Strahlenschutzkommission (SSK)" regarding the indication. These recommendations are not updated on a regular basis and more recent developments are only integrated with delayed. METHODS: The chest division of the German Radiological Society has summarized their expertise for the usage and indication of the chest X­ray. Especially within the field of oncology the usage of chest X­ray is evaluated differently to the aforementioned recommendations; here chest computed tomography (CT) is much more sensitive for evaluation of metastasis and local invasion of tumors. Also, within the area of infectious diseases in non-immunocompetent patients, CT is the method of choice. Based on the structure of the current recommendations, many current guidelines and indications are summarized and presented within the context of the usage of chest X­ray.


Assuntos
Radiologia , Humanos , Pulmão , Radiografia , Radiografia Torácica , Tomografia Computadorizada por Raios X , Raios X
7.
Respir Res ; 22(1): 242, 2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34503520

RESUMO

BACKGROUND: Lung emphysema is an important phenotype of chronic obstructive pulmonary disease (COPD), and CT scanning is strongly recommended to establish the diagnosis. This study aimed to identify criteria by which physicians with limited technical resources can improve the diagnosis of emphysema. METHODS: We studied 436 COPD patients with prospective CT scans from the COSYCONET cohort. All items of the COPD Assessment Test (CAT) and the St George's Respiratory Questionnaire (SGRQ), the modified Medical Research Council (mMRC) scale, as well as data from spirometry and CO diffusing capacity, were used to construct binary decision trees. The importance of parameters was checked by the Random Forest and AdaBoost machine learning algorithms. RESULTS: When relying on questionnaires only, items CAT 1 & 7 and SGRQ 8 & 12 sub-item 3 were most important for the emphysema- versus airway-dominated phenotype, and among the spirometric measures FEV1/FVC. The combination of CAT item 1 (≤ 2) with mMRC (> 1) and FEV1/FVC, could raise the odds for emphysema by factor 7.7. About 50% of patients showed combinations of values that did not markedly alter the likelihood for the phenotypes, and these could be easily identified in the trees. Inclusion of CO diffusing capacity revealed the transfer coefficient as dominant measure. The results of machine learning were consistent with those of the single trees. CONCLUSIONS: Selected items (cough, sleep, breathlessness, chest condition, slow walking) from comprehensive COPD questionnaires in combination with FEV1/FVC could raise or lower the likelihood for lung emphysema in patients with COPD. The simple, parsimonious approach proposed by us might help if diagnostic resources regarding respiratory diseases are limited. Trial registration ClinicalTrials.gov, Identifier: NCT01245933, registered 18 November 2010, https://clinicaltrials.gov/ct2/show/record/NCT01245933 .


Assuntos
Árvores de Decisões , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Índice de Gravidade de Doença , Espirometria/métodos , Idoso , Estudos de Coortes , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Enfisema Pulmonar/epidemiologia , Tomografia Computadorizada por Raios X/métodos
8.
J Magn Reson Imaging ; 54(5): 1562-1571, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34050576

RESUMO

BACKGROUND: There is a clinical need for imaging-derived biomarkers for the management of chronic obstructive pulmonary disease (COPD). Observed pulmonary T1 (T1 (TE)) depends on the echo-time (TE) and reflects regional pulmonary function. PURPOSE: To investigate the potential diagnostic value of T1 (TE) for the assessment of lung disease in COPD patients by determining correlations with clinical parameters and quantitative CT. STUDY TYPE: Prospective non-randomized diagnostic study. POPULATION: Thirty COPD patients (67.7 ± 6.6 years). Data from a previous study (15 healthy volunteers [26.2 ± 3.9 years) were used as reference. FIELD STRENGTH/SEQUENCE: Study participants were examined at 1.5 T using dynamic contrast-enhanced three-dimensional gradient echo keyhole perfusion sequence and a multi-echo inversion recovery two-dimensional UTE (ultra-short TE) sequence for T1 (TE) mapping at TE1-5  = 70 µsec, 500 µsec, 1200 µsec, 1650 µsec, and 2300 µsec. ASSESSMENT: Perfusion images were scored by three radiologists. T1 (TE) was automatically quantified. Computed tomography (CT) images were quantified in software (qCT). Clinical parameters including pulmonary function testing were also acquired. STATISTICAL TESTS: Spearman rank correlation coefficients (ρ) were calculated between T1 (TE) and perfusion scores, clinical parameters and qCT. A P-value <0.05 was considered statistically significant. RESULTS: Median values were T1 (TE1-5 ) = 644 ± 78 msec, 835 ± 92 msec, 835 ± 87 msec, 831 ± 131 msec, 893 ± 220 msec, all significantly shorter than previously reported in healthy subjects. A significant increase of T1 was observed from TE1 to TE2 , with no changes from TE2 to TE3 (P = 0.48), TE3 to TE4 (P = 0.94) or TE4 to TE5 (P = 0.02) which demonstrates an increase at shorter TEs than in healthy subjects. Moderate to strong Spearman's correlations between T1 and parameters including the predicted diffusing capacity for carbon monoxide (DLCO, ρ < 0.70), mean lung density (MLD, ρ < 0.72) and the perfusion score (ρ > -0.69) were found. Overall, correlations were strongest at TE2 , weaker at TE1 and rarely significant at TE4 -TE5 . DATA CONCLUSION: In COPD patients, the increase of T1 (TE) with TE occurred at shorter TEs than previously found in healthy subjects. Together with the lack of correlation between T1 and clinical parameters of disease at longer TEs, this suggests that T1 (TE) quantification in COPD patients requires shorter TEs. The TE-dependence of correlations implies that T1 (TE) mapping might be developed further to provide diagnostic information beyond T1 at a single TE. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Imageamento por Ressonância Magnética , Doença Pulmonar Obstrutiva Crônica , Humanos , Pulmão/diagnóstico por imagem , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Testes de Função Respiratória
9.
Radiologe ; 59(Suppl 1): 10-20, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31172247

RESUMO

BACKGROUND: Despite recent advances in our knowledge about the pathophysiology and treatment of cystic fibrosis (CF), pulmonary involvement remains the most important determinant of morbidity and mortality in patients with CF. Since lung function testing may not be sensitive enough for subclinical disease progression, and because young children may have normal spirometry results over a longer period of time, imaging today plays an increasingly important role in clinical routine and research for the monitoring of CF lung disease. In this regard, chest magnetic resonance imaging (MRI) could serve as a radiation-free modality for structural and functional lung imaging. METHODS: Our research agenda encompassed the entire process of development, implementation, and validation of appropriate chest MRI protocols for use with infant and adult CF patients alike. RESULTS: After establishing a general MRI protocol for state-of-the-art clinical 1.5-T scanners based on the available sequence technology, a semiquantitative scoring system was developed followed by cross-validation of the method against the established modalities of computed tomography, radiography, and lung function testing. Cross-sectional studies were then set up to determine the sensitivity of the method for the interindividual variation of the disease and for changes in disease severity after treatment. Finally, the MRI protocol was implemented at multiple sites to be validated in a multicenter setting. CONCLUSION: After more than a decade, lung MRI has become a valuable tool for monitoring CF in clinical routine application and as an endpoint for clinical studies.


Assuntos
Fibrose Cística , Imageamento por Ressonância Magnética/métodos , Adulto , Criança , Pré-Escolar , Estudos Transversais , Fibrose Cística/diagnóstico por imagem , Feminino , Humanos , Lactente , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Tomografia Computadorizada por Raios X
10.
Chron Respir Dis ; 16: 1479972318775423, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29742906

RESUMO

Phenotyping of chronic obstructive pulmonary disease (COPD) with computed tomography (CT) is used to distinguish between emphysema- and airway-dominated type. The phenotype is reflected in correlations with lung function measures. Among these, the relative value of body plethysmography has not been quantified. We addressed this question using CT scans retrospectively collected from clinical routine in a large COPD cohort. Three hundred and thirty five patients with baseline data of the German COPD cohort COPD and Systemic Consequences-Comorbidities Network were included. CT scans were primarily evaluated using a qualitative binary emphysema score. The binary score was positive for emphysema in 52.5% of patients, and there were significant differences between the positive/negative groups regarding forced expiratory volume in 1 second (FEV1), FEV1/forced vital capacity (FVC), intrathoracic gas volume (ITGV), residual volume (RV), specific airway resistance (sRaw), transfer coefficient (KCO), transfer factor for carbon monoxide (TLCO), age, pack-years, and body mass index (BMI). Stepwise discriminant analyses revealed the combination of FEV1/FVC, RV, sRaw, and KCO to be significantly related to the binary emphysema score. The additional positive predictive value of body plethysmography, however, was only slightly higher than that of the conventional combination of spirometry and diffusing capacity, which if taken alone also achieved high predictive values, in contrast to body plethysmography. The additional information on the presence of CT-diagnosed emphysema as conferred by body plethysmography appeared to be minor compared to the well-known combination of spirometry and CO diffusing capacity.


Assuntos
Pulmão/fisiopatologia , Pletismografia/métodos , Capacidade de Difusão Pulmonar/fisiologia , Enfisema Pulmonar/diagnóstico , Espirometria/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Enfisema Pulmonar/fisiopatologia , Índice de Gravidade de Doença
11.
J Synchrotron Radiat ; 25(Pt 6): 1827-1832, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30407195

RESUMO

In-line free propagation phase-contrast synchrotron tomography of the lungs has been shown to provide superior image quality compared with attenuation-based computed tomography (CT) in small-animal studies. The present study was performed to prove the applicability on a human-patient scale using a chest phantom with ventilated fresh porcine lungs. Local areas of interest were imaged with a pixel size of 100 µm, yielding a high-resolution depiction of anatomical hallmarks of healthy lungs and artificial lung nodules. Details like fine spiculations into surrounding alveolar spaces were shown on a micrometre scale. Minor differences in artificial lung nodule density were detected by phase retrieval. Since we only applied a fraction of the X-ray dose used for clinical high-resolution CT scans, it is believed that this approach may become applicable to the detailed assessment of focal lung lesions in patients in the future.


Assuntos
Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Síncrotrons , Algoritmos , Pontos de Referência Anatômicos , Animais , Humanos , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Estudo de Prova de Conceito , Suínos , Tomografia Computadorizada por Raios X
12.
J Magn Reson Imaging ; 42(3): 610-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25604043

RESUMO

BACKGROUND: This work is intended to demonstrate that T1 measured in the lungs depends on the echo time (TE) used. Measuring lung T1 can be used to gain quantitative morphological and functional information. It is also shown that this dependence is particularly visible when using an ultra-short TE (UTE) sequence with TE well below 1 ms for T1 quantification in lung tissue, rather than techniques with TE on the order of 1-2 ms. METHODS: The lungs of 12 healthy volunteers (aged 22 to 33 years) were examined at 1.5 Tesla. A segmented inversion recovery Look-Locker multi-echo sequence based on two-dimensional UTE was used for independent T1 quantification at five TEs between TE1 = 70 µs and TE5 = 2.3 ms. RESULTS: The measured T1 was found to increase gradually with TE from 1060 ± 40 ms at TE1 to 1389 ± 53 ms at TE5 (P < 0.001). CONCLUSION: Measuring T1 at ultra-short echo times reveals a significant dependence of observed T1 on the echo time. Thus, any comparison of T1 values should also consider the TEs used. However, this dependence on TE could also be exploited to gain additional diagnostic information on the tissue compartments in the lung.


Assuntos
Pulmão/patologia , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Meios de Contraste/química , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Imagens de Fantasmas , Razão Sinal-Ruído , Fatores de Tempo , Adulto Jovem
13.
MAGMA ; 28(3): 227-38, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25381181

RESUMO

OBJECTIVE: To optimize a radial turbo spin-echo sequence for motion-robust morphological lung magnetic resonance imaging (MRI) in free respiration. MATERIALS AND METHODS: A versatile multi-shot radial turbo spin-echo (rTSE) sequence is presented, using a modified golden ratio-based reordering designed to prevent coherent streaking due to data inconsistencies from physiological motion and the decaying signal. The point spread function for a moving object was simulated using a model for joint respiratory and cardiac motion with a concomitant T2 signal decay and with rTSE acquisition using four different reordering techniques. The reordering strategies were compared in vivo using healthy volunteers and the sequence was tested for feasibility in two patients with lung cancer and pneumonia. RESULTS: Simulations and in vivo measurements showed very weak artifacts, aside from motion blur, using the proposed reordering. Due to the opportunity for longer scan times in free respiration, a high signal-to-noise ratio (SNR) was achieved, facilitating identification of the disease as compared to standard half-Fourier-acquisition single-shot turbo spin-echo (HASTE) scans. Additionally, post-processing allowed modifying the T2 contrast retrospectively, further improving the diagnostic fidelity. CONCLUSION: The proposed radial TSE sequence allowed for high-resolution imaging with limited obscuring artifacts. The radial k-space traversal allowed for versatile post-processing that may help to improve the diagnosis of subtle diseases.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/patologia , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Algoritmos , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Marcadores de Spin
14.
Am J Respir Crit Care Med ; 189(8): 956-65, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24564281

RESUMO

RATIONALE: Studies demonstrating early structural lung damage in infants and preschool children with cystic fibrosis (CF) suggest that noninvasive monitoring will be important to identify patients who may benefit from early therapeutic intervention. Previous studies demonstrated that magnetic resonance imaging (MRI) detects structural and functional abnormalities in lungs from older patients with CF without radiation exposure. OBJECTIVES: To evaluate the potential of MRI to detect abnormal lung structure and perfusion in infants and preschool children with CF, and to monitor the response to therapy for pulmonary exacerbation. METHODS: MRI studies were performed in 50 children with CF (age, 3.1 ± 2.1 yr; range, 0-6 yr) in stable clinical condition (n = 40) or pulmonary exacerbation before and after antibiotic treatment (n = 10), and in 26 non-CF control subjects (age, 2.9 ± 1.9 yr). T1- and T2-weighted sequences before and after intravenous contrast and first-pass perfusion imaging were acquired, and assessed on the basis of a dedicated morphofunctional score. MEASUREMENTS AND MAIN RESULTS: MRI demonstrated bronchial wall thickening/bronchiectasis, mucus plugging, and perfusion deficits from the first year of life in most stable patients with CF (global score, 10.0 ± 4.0), but not in non-CF control subjects (score, 0.0 ± 0.0; P < 0.001). In patients with exacerbations, the global MRI score was increased to 18.0 ± 2.0 (P < 0.001), and was significantly reduced to 12.0 ± 3.0 (P < 0.05) after antibiotic therapy. CONCLUSIONS: MRI detected abnormalities in lung structure and perfusion, and response to therapy for exacerbations in infants and preschool children with CF. These results support the development of MRI for noninvasive monitoring and as an end point in interventional trials for early CF lung disease. Clinical trial registered with www.clinicaltrials.gov (NCT00760071).


Assuntos
Fibrose Cística/diagnóstico , Pulmão/patologia , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Estudos de Casos e Controles , Pré-Escolar , Fibrose Cística/tratamento farmacológico , Fibrose Cística/patologia , Fibrose Cística/fisiopatologia , Diagnóstico Precoce , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
15.
Front Med (Lausanne) ; 11: 1360706, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38495118

RESUMO

Background: Chronic obstructive pulmonary disease (COPD) poses a substantial global health burden, demanding advanced diagnostic tools for early detection and accurate phenotyping. In this line, this study seeks to enhance COPD characterization on chest computed tomography (CT) by comparing the spatial and quantitative relationships between traditional parametric response mapping (PRM) and a novel self-supervised anomaly detection approach, and to unveil potential additional insights into the dynamic transitional stages of COPD. Methods: Non-contrast inspiratory and expiratory CT of 1,310 never-smoker and GOLD 0 individuals and COPD patients (GOLD 1-4) from the COPDGene dataset were retrospectively evaluated. A novel self-supervised anomaly detection approach was applied to quantify lung abnormalities associated with COPD, as regional deviations. These regional anomaly scores were qualitatively and quantitatively compared, per GOLD class, to PRM volumes (emphysema: PRMEmph, functional small-airway disease: PRMfSAD) and to a Principal Component Analysis (PCA) and Clustering, applied on the self-supervised latent space. Its relationships to pulmonary function tests (PFTs) were also evaluated. Results: Initial t-Distributed Stochastic Neighbor Embedding (t-SNE) visualization of the self-supervised latent space highlighted distinct spatial patterns, revealing clear separations between regions with and without emphysema and air trapping. Four stable clusters were identified among this latent space by the PCA and Cluster Analysis. As the GOLD stage increased, PRMEmph, PRMfSAD, anomaly score, and Cluster 3 volumes exhibited escalating trends, contrasting with a decline in Cluster 2. The patient-wise anomaly scores significantly differed across GOLD stages (p < 0.01), except for never-smokers and GOLD 0 patients. In contrast, PRMEmph, PRMfSAD, and cluster classes showed fewer significant differences. Pearson correlation coefficients revealed moderate anomaly score correlations to PFTs (0.41-0.68), except for the functional residual capacity and smoking duration. The anomaly score was correlated with PRMEmph (r = 0.66, p < 0.01) and PRMfSAD (r = 0.61, p < 0.01). Anomaly scores significantly improved fitting of PRM-adjusted multivariate models for predicting clinical parameters (p < 0.001). Bland-Altman plots revealed that volume agreement between PRM-derived volumes and clusters was not constant across the range of measurements. Conclusion: Our study highlights the synergistic utility of the anomaly detection approach and traditional PRM in capturing the nuanced heterogeneity of COPD. The observed disparities in spatial patterns, cluster dynamics, and correlations with PFTs underscore the distinct - yet complementary - strengths of these methods. Integrating anomaly detection and PRM offers a promising avenue for understanding of COPD pathophysiology, potentially informing more tailored diagnostic and intervention approaches to improve patient outcomes.

16.
J Magn Reson Imaging ; 37(3): 727-32, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22987283

RESUMO

PURPOSE: To use the acquisition of the k-space center signal (DC signal) implemented into a Cartesian three-dimensional (3D) FLASH sequence for retrospective respiratory self-gating and, thus, for the examination of the whole human lung in high spatial resolution during free breathing. MATERIALS AND METHODS: Volunteer as well as patient measurements were performed under free breathing conditions. The DC signal is acquired after the actual image data acquisition within each excitation of a 3D FLASH sequence. The DC signal is then used to track respiratory motion for retrospective respiratory gating. RESULTS: It is shown that the acquisition of the DC signal after the imaging module can be used in a 3D FLASH sequence to extract respiratory motion information for retrospective respiratory self-gating and allows for shorter echo times (TE) and therefore increased lung parenchyma SNR. CONCLUSION: The acquisition of the DC signal after image signal acquisition allows successful retrospective gating, enabling the reconstruction of high resolution images of the whole human lung under free breathing conditions.


Assuntos
Imageamento Tridimensional/métodos , Pulmão/patologia , Imageamento por Ressonância Magnética/instrumentação , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pneumopatias/patologia , Imageamento por Ressonância Magnética/métodos , Movimento , Estudos Retrospectivos , Razão Sinal-Ruído
17.
Invest Radiol ; 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37812482

RESUMO

OBJECTIVES: With the introduction of clinical photon-counting detector computed tomography (PCD-CT) and its novel reconstruction techniques, a quantitative investigation of different acquisition and reconstruction settings is necessary to optimize clinical acquisition protocols for metal artifact reduction. MATERIALS AND METHODS: A multienergy phantom was scanned on a clinical dual-source PCD-CT (NAEOTOM Alpha; Siemens Healthcare GmbH) with 4 different central inserts: water-equivalent plastic, aluminum, steel, and titanium. Acquisitions were performed at 120 kVp and 140 kVp (CTDIvol 10 mGy) and reconstructed as virtual monoenergetic images (VMIs; 110-150 keV), as T3D, and with the standard reconstruction "none" (70 keV VMI) using different reconstruction kernels (Br36, Br56) and with as well as without iterative metal artifact reduction (iMAR). Metal artifacts were quantified, calculating relative percentages of metal artifacts. Mean CT numbers of an adjacent water-equivalent insert and different tissue-equivalent inserts were evaluated, and eccentricity of metal rods was measured. Repeated-measures analysis of variance was performed for statistical analysis. RESULTS: Metal artifacts were most prevalent for the steel insert (12.6% average artifacts), followed by titanium (4.2%) and aluminum (1.0%). The strongest metal artifact reduction was noted for iMAR (with iMAR: 1.4%, without iMAR: 10.5%; P < 0.001) or VMI (VMI: 110 keV 2.6% to 150 keV 3.3%, T3D: 11.0%, and none: 16.0%; P < 0.001) individually, with best results when combining iMAR and VMI at 110 keV (1.2%). Changing acquisition tube potential (120 kV: 6.6%, 140 kV: 5.2%; P = 0.33) or reconstruction kernel (Br36: 5.5%, Br56: 6.4%; P = 0.17) was less effective. Mean CT numbers and standard deviations were significantly affected by iMAR (with iMAR: -3.0 ± 21.5 HU, without iMAR: -8.5 ± 24.3 HU; P < 0.001), VMI (VMI: 110 keV -3.6 ± 21.6 HU to 150 keV -1.4 ± 21.2 HU, T3D: -11.7 ± 23.8 HU, and none: -16.9 ± 29.8 HU; P < 0.001), tube potential (120 kV: -4.7 ± 22.8 HU, 140 kV: -6.8 ± 23.0 HU; P = 0.03), and reconstruction kernel (Br36: -5.5 ± 14.2 HU, Br56: -6.8 ± 23.0 HU; P < 0.001). Both iMAR and VMI improved quantitative CT number accuracy and metal rod eccentricity for the steel rod, but iMAR was of limited effectiveness for the aluminum rod. CONCLUSIONS: For metal artifact reduction in PCD-CT, a combination of iMAR and VMI at 110 keV demonstrated the strongest artifact reduction of the evaluated options, whereas the impact of reconstruction kernel and tube potential was limited.

18.
Radiol Cardiothorac Imaging ; 5(2): e220176, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37124637

RESUMO

Purpose: To investigate morphofunctional chest MRI for the detection and management of incidental pulmonary nodules in participants with chronic obstructive pulmonary disease (COPD). Materials and Methods: In this prospective study, 567 participants (mean age, 66 years ± 9 [SD]; 340 men) underwent same-day contrast-enhanced MRI and nonenhanced low-dose CT (LDCT) in a nationwide multicenter trial (clinicaltrials.gov: NCT01245933). Nodule dimensions, morphologic features, and Lung Imaging Reporting and Data System (Lung-RADS) category were assessed at MRI by two blinded radiologists, and consensual LDCT results served as the reference standard. Comparisons were performed using the Student t test, and agreements were assessed using the Cohen weighted κ. Results: A total of 525 nodules larger than 3 mm in diameter were detected at LDCT in 178 participants, with a mean diameter of 7.2 mm ± 6.1 (range, 3.1-63.1 mm). Nodules were not detected in the remaining 389 participants. Sensitivity and positive predictive values with MRI for readers 1 and 2, respectively, were 63.0% and 84.8% and 60.2% and 83.9% for solid nodules (n = 495), 17.6% and 75.0% and 17.6% and 60.0% for part-solid nodules (n = 17), and 7.7% and 100% and 7.7% and 50.0% for ground-glass nodules (n = 13). For nodules 6 mm or greater in diameter, sensitivity and positive predictive values were 73.3% and 92.2% for reader 1 and 71.4% and 93.2% for reader 2, respectively. Readers underestimated the long-axis diameter at MRI by 0.5 mm ± 1.7 (reader 1) and 0.5 mm ± 1.5 (reader 2) compared with LDCT (P < .001). For Lung-RADS categorization per nodule using MRI, there was substantial to perfect interreader agreement (κ = 0.75-1.00) and intermethod agreement compared with LDCT (κ = 0.70-1.00 and 0.69-1.00). Conclusion: In a multicenter setting, morphofunctional MRI showed moderate sensitivity for detection of incidental pulmonary nodules in participants with COPD but high agreement with LDCT for Lung-RADS classification of nodules.Clinical trial registration no. NCT01245933 and NCT02629432Keywords: MRI, CT, Thorax, Lung, Chronic Obstructive Pulmonary Disease, Screening© RSNA, 2023 Supplemental material is available for this article.

19.
Front Med (Lausanne) ; 10: 1254003, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38249975

RESUMO

Introduction: Due to hypoxic vasoconstriction, perfusion is interesting in the lungs. Magnetic Resonance Imaging (MRI) perfusion imaging based on Dynamic Contrast Enhancement (DCE) has been demonstrated in patients with Chronic Obstructive Pulmonary Diseases (COPD) using visual scores, and quantification methods were recently developed further. Inter-patient correlations of echo time-dependent observed T1 [T1(TE)] have been shown with perfusion scores, pulmonary function testing, and quantitative computed tomography. Here, we examined T1(TE) quantification and quantitative perfusion MRI together and investigated both inter-patient and local correlations between T1(TE) and quantitative perfusion. Methods: 22 patients (age 68.0 ± 6.2) with COPD were examined using morphological MRI, inversion recovery multi-echo 2D ultra-short TE (UTE) in 1-2 slices for T1(TE) mapping, and 4D Time-resolved angiography With Stochastic Trajectories (TWIST) for DCE. T1(TE) maps were calculated from 2D UTE at five TEs from 70 to 2,300 µs. Pulmonary Blood Flow (PBF) and perfusion defect (QDP) maps were produced from DCE measurements. Lungs were automatically segmented on UTE images and morphological MRI and these segmentations registered to DCE images. DCE images were separately registered to UTE in corresponding slices and divided into corresponding subdivisions. Spearman's correlation coefficients were calculated for inter-patient correlations using the entire segmented slices and for local correlations separately using registered images and subdivisions for each TE. Median T1(TE) in normal and defect areas according to QDP maps were compared. Results: Inter-patient correlations were strongest on average at TE2 = 500 µs, reaching up to |ρ| = 0.64 for T1 with PBF and |ρ| = 0.76 with QDP. Generally, local correlations of T1 with PBF were weaker at TE2 than at TE1 or TE3 and with maximum values of |ρ| = 0.66 (from registration) and |ρ| = 0.69 (from subdivision). In 18 patients, T1 was shorter in defect areas than in normal areas, with the relative difference smallest at TE2. Discussion: The inter-patient correlations of T1 with PBF and QDP found show similar strength and TE-dependence as those previously reported for visual perfusion scores and quantitative computed tomography. The local correlations and median T1 suggest that not only base T1 but also the TE-dependence of observed T1 in normal areas is closer to that found previously in healthy volunteers than in defect areas.

20.
Sci Rep ; 13(1): 4788, 2023 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-36959233

RESUMO

Absorption-based clinical computed tomography (CT) is the current imaging method of choice in the diagnosis of lung diseases. Many pulmonary diseases are affecting microscopic structures of the lung, such as terminal bronchi, alveolar spaces, sublobular blood vessels or the pulmonary interstitial tissue. As spatial resolution in CT is limited by the clinically acceptable applied X-ray dose, a comprehensive diagnosis of conditions such as interstitial lung disease, idiopathic pulmonary fibrosis or the characterization of small pulmonary nodules is limited and may require additional validation by invasive lung biopsies. Propagation-based imaging (PBI) is a phase sensitive X-ray imaging technique capable of reaching high spatial resolutions at relatively low applied radiation dose levels. In this publication, we present technical refinements of PBI for the characterization of different artificial lung pathologies, mimicking clinically relevant patterns in ventilated fresh porcine lungs in a human-scale chest phantom. The combination of a very large propagation distance of 10.7 m and a photon counting detector with [Formula: see text] pixel size enabled high resolution PBI CT with significantly improved dose efficiency, measured by thermoluminescence detectors. Image quality was directly compared with state-of-the-art clinical CT. PBI with increased propagation distance was found to provide improved image quality at the same or even lower X-ray dose levels than clinical CT. By combining PBI with iodine k-edge subtraction imaging we further demonstrate that, the high quality of the calculated iodine concentration maps might be a potential tool for the analysis of lung perfusion in great detail. Our results indicate PBI to be of great value for accurate diagnosis of lung disease in patients as it allows to depict pathological lesions non-invasively at high resolution in 3D. This will especially benefit patients at high risk of complications from invasive lung biopsies such as in the setting of suspected idiopathic pulmonary fibrosis (IPF).


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Animais , Suínos , Humanos , Raios X , Pulmão/diagnóstico por imagem , Pulmão/patologia , Tomografia Computadorizada por Raios X/métodos , Doenças Pulmonares Intersticiais/patologia , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Fibrose Pulmonar Idiopática/patologia , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA