Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Phys Rev Lett ; 130(10): 101001, 2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36962014

RESUMO

Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c^{2} mass dark matter. We present new constraints for sub-GeV/c^{2} dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12 306±184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c^{2}. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below 3.6 GeV/c^{2}.

2.
Phys Rev Lett ; 130(10): 101002, 2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36962032

RESUMO

We present a search for dark matter particles with sub-GeV/c^{2} masses whose interactions have final state electrons using the DarkSide-50 experiment's (12 306±184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section σ[over ¯]_{e}, the axioelectric coupling constant g_{Ae}, and the dark photon kinetic mixing parameter κ. We also set the first dark matter direct-detection constraints on the mixing angle |U_{e4}|^{2} for keV/c^{2} sterile neutrinos.

3.
Phys Rev Lett ; 121(11): 111303, 2018 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-30265123

RESUMO

We present new constraints on sub-GeV dark-matter particles scattering off electrons based on 6780.0 kg d of data collected with the DarkSide-50 dual-phase argon time projection chamber. This analysis uses electroluminescence signals due to ionized electrons extracted from the liquid argon target. The detector has a very high trigger probability for these signals, allowing for an analysis threshold of three extracted electrons, or approximately 0.05 keVee. We calculate the expected recoil spectra for dark matter-electron scattering in argon and, under the assumption of momentum-independent scattering, improve upon existing limits from XENON10 for dark-matter particles with masses between 30 and 100 MeV/c^{2}.

4.
Phys Rev Lett ; 121(8): 081307, 2018 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-30192596

RESUMO

We present the results of a search for dark matter weakly interacting massive particles (WIMPs) in the mass range below 20 GeV/c^{2} using a target of low-radioactivity argon with a 6786.0 kg d exposure. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso. The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 event/keVee/kg/d and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^{2} for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^{2}.

5.
Phys Rev Lett ; 116(15): 151806, 2016 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-27127961

RESUMO

We report results from the first search for ν_{µ}→ν_{e} transitions by the NOvA experiment. In an exposure equivalent to 2.74×10^{20} protons on target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of 0.99±0.11(syst) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of 1.07±0.14(syst). The 3.3σ excess of events observed in the primary analysis disfavors 0.1π<δ_{CP}<0.5π in the inverted mass hierarchy at the 90% C.L.

6.
Eur Phys J C Part Fields ; 83(6): 467, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37303462

RESUMO

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous νe appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV2. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

7.
Anesth Prog ; 37(4): 201-4, 1990 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2129002

RESUMO

Five patients requiring general anesthesia but presenting with compromised airways were successfully intubated by blind awake intubation with the aid of regional anesthesia and the use of appropriate sedation. Arterial blood gases were collected at three intervals: presedation, postsedation, and postintubation. Analysis of the blood gases revealed varying degrees of hypoxemia, hypercarbia, and acidosis following deep sedation before intubation. A decrease in oxygen saturation was also observed. Supplemental oxygen is suggested to avoid the effects of arterial desaturation during the sedation process. If oxygen is not administered, the risk of moderate hypoxia associated with blind awake intubation must be considered along with alternative problems including loss of protective reflexes or the inability to ventilate during induction and intubation via a direct technique.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos , Intubação Intratraqueal/métodos , Adulto , Anestesia Geral , Dióxido de Carbono/análise , Droperidol , Feminino , Fentanila , Humanos , Hipóxia , Masculino , Pessoa de Meia-Idade , Pressão Parcial , Tiopental , Vigília
8.
Anesth Prog ; 34(2): 58-60, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3474911

RESUMO

A retrospective study of 672 ASA Class I patients undergoing outpatient general anesthesia for oral surgical procedures was performed to evaluate the significance and incidence of abnormal preoperative serum glucose and hematocrit levels. There was an 11% overall incidence of "abnormal" values. Specifically, 6% of the patients had serum glucose levels below 60 g/dl and 5% had hematocritis less than 35 mg/dl. These values are not outside the realm of normal and had no impact on the preoperative, perioperative, or postoperative anesthetic management. The results of this study and review of the suggest that routine laboratory analysis is of little value in the anesthetic management of ASA Class I patients in which a thorough history and physical examination is obtained.


Assuntos
Anestesia Dentária , Anestesia Geral , Glicemia/análise , Hematócrito , Adulto , Criança , Humanos , Cuidados Pré-Operatórios , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA