J Acoust Soc Am ; 146(4): 2350, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31671949

RESUMO

Monitoring mechanical systems operating in uncertain environments contaminated with both environmental disturbances and noise lead directly to low signal-to-noise-ratios, creating an extremely challenging processing problem, especially in real-time. In order to estimate the performance of a particular system from uncertain vibrational data, it is necessary to identify its unique resonant (modal) frequency signature. The monitoring of structural modes to determine the condition of a device under investigation is essential, especially if it is a critical entity of an operational system. The development of a model-based scheme capable of the on-line tracking of the inherent structural modal frequencies by applying both constrained subspace identification techniques to extract the modal frequencies and state estimation methods to track the evolution is discussed. An application of this approach to a cylindrical structural device (pipe-in-air) is analyzed based on theoretical simulations along with controlled validation experiments, including injected anomalies illustrate the approach and performance. Statistics are gathered to bound potential processors for real-time performance employing these constrained techniques.

2.
Rev Sci Instrum ; 81(10): 10D335, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033855

RESUMO

Numerical modeling of the neutron imaging system for the National Ignition Facility (NIF), forward from calculated target neutron emission to a camera image, will guide both the reduction of data and the future development of the system. Located 28 m from target chamber center, the system can produce two images at different neutron energies by gating on neutron arrival time. The brighter image, using neutrons near 14 MeV, reflects the size and symmetry of the implosion "hot spot." A second image in scattered neutrons, 10-12 MeV, reflects the size and symmetry of colder, denser fuel, but with only ∼1%-7% of the neutrons. A misalignment of the pinhole assembly up to ±175 µm is covered by a set of 37 subapertures with different pointings. The model includes the variability of the pinhole point spread function across the field of view. Omega experiments provided absolute calibration, scintillator spatial broadening, and the level of residual light in the down-scattered image from the primary neutrons. Application of the model to light decay measurements of EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A suggests that DPAC-30 and Liquid A would be preferred over the BCF99-55 scintillator chosen for the first NIF system, if they could be fabricated into detectors with sufficient resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA