Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Obes (Lond) ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926461

RESUMO

BACKGROUND/OBJECTIVES: Weight loss outcomes vary individually. Magnetic resonance imaging (MRI)-based evaluation of adipose tissue (AT) might help to identify AT characteristics that predict AT loss. This study aimed to assess the impact of an 8-week low-calorie diet (LCD) on different AT depots and to identify predictors of short-term AT loss using MRI in adults with obesity. METHODS: Eighty-one adults with obesity (mean BMI 34.08 ± 2.75 kg/m², mean age 46.3 ± 10.97 years, 49 females) prospectively underwent baseline MRI (liver dome to femoral head) and anthropometric measurements (BMI, waist-to-hip-ratio, body fat), followed by a post-LCD-examination. Visceral and subcutaneous AT (VAT and SAT) volumes and AT fat fraction were extracted from the MRI data. Apparent lipid volumes based on MRI were calculated as approximation for the lipid contained in the AT. SAT and VAT volumes were subdivided into equidistant thirds along the craniocaudal axis and normalized by length of the segmentation. T-tests compared baseline and follow-up measurements and sex differences. Effect sizes on subdivided AT volumes were compared. Spearman Rank correlation explored associations between baseline parameters and AT loss. Multiple regression analysis identified baseline predictors for AT loss. RESULTS: Following the LCD, participants exhibited significant weight loss (11.61 ± 3.07 kg, p < 0.01) and reductions in all MRI-based AT parameters (p < 0.01). Absolute SAT loss exceeded VAT loss, while relative apparent lipid loss was higher in VAT (both p < 0.01). The lower abdominopelvic third showed the most significant SAT and VAT reduction. The predictor of most AT and apparent lipid losses was the normalized baseline SAT volume in the lower abdominopelvic third, with smaller volumes favoring greater AT loss (p < 0.01 for SAT and VAT loss and SAT apparent lipid volume loss). CONCLUSIONS: The LCD primarily reduces lower abdominopelvic SAT and VAT. Furthermore, lower abdominopelvic SAT volume was detected as a potential predictor for short-term AT loss in persons with obesity.

2.
Eur Radiol ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38388721

RESUMO

OBJECTIVE: This study analyzes the potential cost-effectiveness of integrating an artificial intelligence (AI)-assisted system into the differentiation of incidental renal lesions as benign or malignant on MR images during follow-up. MATERIALS AND METHODS: For estimation of quality-adjusted life years (QALYs) and lifetime costs, a decision model was created, including the MRI strategy and MRI + AI strategy. Model input parameters were derived from recent literature. Willingness to pay (WTP) was set to $100,000/QALY. Costs of $0 for the AI were assumed in the base-case scenario. Model uncertainty and costs of the AI system were assessed using deterministic and probabilistic sensitivity analysis. RESULTS: Average total costs were at $8054 for the MRI strategy and $7939 for additional use of an AI-based algorithm. The model yielded a cumulative effectiveness of 8.76 QALYs for the MRI strategy and of 8.77 for the MRI + AI strategy. The economically dominant strategy was MRI + AI. Deterministic and probabilistic sensitivity analysis showed high robustness of the model with the incremental cost-effectiveness ratio (ICER), which represents the incremental cost associated with one additional QALY gained, remaining below the WTP for variation of the input parameters. If increasing costs for the algorithm, the ICER of $0/QALY was exceeded at $115, and the defined WTP was exceeded at $667 for the use of the AI. CONCLUSIONS: This analysis, rooted in assumptions, suggests that the additional use of an AI-based algorithm may be a potentially cost-effective alternative in the differentiation of incidental renal lesions using MRI and needs to be confirmed in the future. CLINICAL RELEVANCE STATEMENT: These results hint at AI's the potential impact on diagnosing renal masses. While the current study urges careful interpretation, ongoing research is essential to confirm and seamlessly integrate AI into clinical practice, ensuring its efficacy in routine diagnostics. KEY POINTS: • This is a model-based study using data from literature where AI has been applied in the diagnostic workup of incidental renal lesions. • MRI + AI has the potential to be a cost-effective alternative in the differentiation of incidental renal lesions. • The additional use of AI can reduce costs in the diagnostic workup of incidental renal lesions.

3.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855855

RESUMO

OBJECTIVES: T2 STIR MRI sequences can detect preclinical changes associated with periodontal inflammation, i.e. intraosseous edema in the tooth-supporting bone. In this study, we assessed whether MRI can be used for monitoring periodontal disease. MATERIAL AND METHODS: In a prospective cohort study, we examined 35 patients with periodontitis between 10/2018 and 04/2019 by using 3D isotropic T2-weighted short tau inversion recovery (STIR) and Fast Field Echo T1-weighted Black bone sequences. All patients received standardized clinical exams before and three months after non-surgical periodontal therapy. Bone marrow edema extent was quantified in the STIR sequence at 922 sites before and after treatment. Results were compared with standard clinical findings. Non-parametric statistical analysis was performed. RESULTS: Non-surgical periodontal treatment caused significant improvement in mean probing depth (p < 0.001) and frequency of bleeding on probing (p < 0.001). The mean depth of osseous edema per site was reduced from a median [IQR] of 2 [1, 3] mm at baseline to 1 [0, 3] mm, (p < 0.001). Periodontal treatment reduced the frequency of sites with edema from 35 to 24% (p < 0.01). CONCLUSION: The decrease of periodontal bone marrow edema, as observed with T2 STIR MR imaging, is indicative of successful periodontal healing. CLINICAL RELEVANCE STATEMENT: T2 STIR hyperintense bone marrow edema in the periodontal bone decreases after treatment and can therefore be used to evaluate treatment success. Furthermore, MRI reveals new options to depict hidden aspects of periodontitis. KEY POINTS: • T2 STIR hyperintense periodontal intraosseous edema was prospectively investigated in 35 patients with periodontitis before and after treatment and compared to clinical outcomes. • The frequency of affected sites was reduced from 35 to 24% (p < 0.001), and mean edema depth was reduced from a median [IQR] of 2 [1, 3] mm at baseline to 1 [0, 3] mm 3 months after treatment. (p < 0.001). • T2 STIR sequences can be used to monitor the posttreatment course of periodontitis.

4.
Ultraschall Med ; 44(5): e248-e256, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36646113

RESUMO

PURPOSE: This prospective two-centre study investigated localisation-dependent lesion patterns in COVID-19 with standard lung ultrasonography (LUS) and their relationship with thoracic computed tomography (CT) and clinical parameters. MATERIALS AND METHODS: Between April 2020 and April 2021, 52 SARS-CoV-2-positive patients in two hospitals were examined by means of LUS for "B-lines", fragmented pleura, consolidation and air bronchogram in 12 lung regions and for pleural effusions. A newly developed LUS score based on the number of features present was correlated with clinical parameters (respiration, laboratory parameters) and the CT and analysed with respect to the 30- and 60-day outcome. All patients were offered an outpatient LUS follow-up. RESULTS: The LUS and CT showed a bilateral, partially posteriorly accentuated lesion distribution pattern. 294/323 (91%) of CT-detected lesions were pleural. The LUS score showed an association with respiratory status and C-reactive protein; the correlation with the CT score was weak (Spearman's rho = 0.339, p < 0.001). High LUS scores on admission were also observed in patients who were discharged within 30 days. LUS during follow-up showed predominantly declining LUS scores. CONCLUSION: The LUS score reflected the clinical condition of the patients. No conclusion could be made on the prognostic value of the LUS, because of the low event rate. The LUS and CT score showed no sufficient correlation. This is probably due to different physical principles, which is why LUS could be of complementary value.

5.
Clin Oral Investig ; 27(7): 3705-3712, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37039958

RESUMO

OBJECTIVES: Maxillary sinus mucositis is frequently associated with odontogenic foci. Periapical inflammation of maxillary molars and premolars cannot be visualized directly using radiation-based imaging. The purpose of this study was to answer the following clinical question: among patients with periapical inflammatory processes in the maxilla, does the use of magnetic resonance imaging (MRI), as compared to conventional periapical (AP) and panoramic radiography (OPT), improve diagnostic accuracy? METHODS: Forty-two subjects with generalized periodontitis were scanned on a 3 T MRI. Sixteen asymptomatic subjects with mucosal swelling of the maxillary sinus were enrolled in the study. Periapical edema was assessed using short tau inversion recovery (STIR) sequence. Apical osteolysis and mucosal swelling were assessed by MRI, AP, and OPT imaging using the periapical index score (PAI). Comparisons between groups were performed with chi-squared tests with Yates' correction. Significance was set at p < 0.05. RESULTS: Periapical lesions of maxillary premolars and molars were identified in 16 subjects, 21 sinuses, and 58 teeth. Bone edema and PAI scores were significantly higher using MRI as compared to OPT and AP (p < 0.05). Using the STIR sequence, a significant association of PAI score > 1 and the presence of mucosal swelling in the maxillary sinus was detected (p = 0.03). CONCLUSION: Periapical inflammation and maxillary mucositis could be visualized using STIR imaging. The use of MRI may help detect early, subtle inflammatory changes in the periapical tissues surrounding maxillary dentition. Early detection could guide diagnostic criteria, as well as treatment and prevention.


Assuntos
Mucosite , Periodontite Periapical , Humanos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/patologia , Estudos de Viabilidade , Inflamação/diagnóstico por imagem , Inflamação/patologia , Periodontite Periapical/complicações , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Feixe Cônico/métodos
6.
Clin Oral Investig ; 27(9): 5063-5072, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37382718

RESUMO

OBJECTIVE: To determine the accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. MATERIAL AND METHODS: A retrospective analysis of 28 patients that underwent virtually planned orthognathic surgery with maxillary Le Fort I osteotomy either using VSP-generated splints (n = 13) or patient-specific implants (PSI) (n = 15) was conducted. The accuracy and surgical outcome of both techniques were compared by superimposing preoperative surgical planning with postoperative CT scans and measurement of translational and rotational deviation for each patient. RESULTS: The 3D global geometric deviation between the planned position and the postoperative outcome was 0.60 mm (95%-CI 0.46-0.74, range 0.32-1.11 mm) for patients with PSI and 0.86 mm (95%-CI 0.44-1.28, range 0.09-2.60 mm) for patients with surgical splints. Postoperative differences for absolute and signed single linear deviations between planned and postoperative position were a little higher regarding the x-axis and pitch but lower regarding the y- and z-axis as well as yaw and roll for PSI compared to surgical splints. There were no significant differences regarding global geometric deviation, absolute and signed linear deviations in the x-, y-, and z-axis, and rotations (yaw, pitch, and roll) between both groups. CONCLUSIONS: Regarding accuracy for positioning of maxillary segments after Le Fort I osteotomy in orthognathic surgery patient-specific implants and surgical splints provide equivalent high accuracy. CLINICAL RELEVANCE: Patient-specific implants for maxillary positioning and fixation facilitate the concept of splintless orthognathic surgery and can be reliably used in clinical routines.


Assuntos
Implantes Dentários , Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Humanos , Placas Oclusais , Procedimentos Cirúrgicos Ortognáticos/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Maxila/cirurgia , Computadores , Imageamento Tridimensional/métodos , Osteotomia de Le Fort/métodos
7.
Clin Oral Investig ; 27(9): 5403-5412, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37464086

RESUMO

OBJECTIVES: To detect and evaluate early signs of apical periodontitis using MRI based on a 3D short-tau-inversion-recovery (STIR) sequence compared to conventional panoramic radiography (OPT) and periapical radiographs in patients with apical periodontitis. MATERIALS AND METHODS: Patients with clinical evidence of periodontal disease were enrolled prospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR sequence. The MRI sequences were assessed for the occurrence and extent of bone changes associated with apical periodontitis including bone edema, periradicular cysts, and dental granulomas. OPTs and intraoral periapical radiographs, if available, were assessed for corresponding periapical radiolucencies using the periapical index (PAI). RESULTS: In total, 232 teeth of 37 patients (mean age 62±13.9 years, 18 women) were assessed. In 69 cases reactive bone edema was detected on MRI with corresponding radiolucency according to OPT. In 105 cases edema was detected without corresponding radiolucency on OPT. The overall extent of edema measured on MRI was significantly larger compared to the radiolucency on OPT (mean: STIR 2.4±1.4 mm, dental radiograph 1.3±1.2 mm, OPT 0.8±1.1 mm, P=0.01). The overall PAI score was significantly higher on MRI compared to OPT (mean PAI: STIR 1.9±0.7, dental radiograph 1.3±0.5, OPT 1.2±0.7, P=0.02). CONCLUSION: Early detection and assessment of bone changes of apical periodontitis using MRI was feasible while the extent of bone edema measured on MRI exceeded the radiolucencies measured on OPT. CLINICAL RELEVANCE: In clinical routine, dental MRI might be useful for early detection and assessment of apical periodontitis before irreversible bone loss is detected on conventional panoramic and intraoral periapical radiographs.


Assuntos
Periodontite Periapical , Dente não Vital , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Tratamento do Canal Radicular , Periodontite Periapical/complicações , Radiografia , Imageamento por Ressonância Magnética , Dente não Vital/diagnóstico por imagem
8.
Clin Oral Investig ; 27(3): 1227-1233, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36208329

RESUMO

OBJECTIVES: To assess and compare the diagnostic performance of CT-like images based on a three- dimensional (3D) T1-weighted spoiled gradient-echo sequence (3D T1 GRE) with CT in patients with acute traumatic fractures of the mandible. MATERIALS AND METHODS: Subjects with acute mandibular fractures diagnosed on conventional CT were prospectively recruited and received an additional 3 T MRI with a CT-like 3D T1 GRE sequence. The images were assessed by two radiologists with regard to fracture localization, degree of dislocation, and number of fragments. Bone to soft tissue contrast, diagnostic confidence, artifacts, and overall image quality were rated using a five-point Likert-scale. Agreement of measurements was assessed using an independent t-test. RESULTS: Fourteen subjects and 22 fracture sites were included (26 ± 3.9 years; 4 females, 10 males). All traumatic fractures were accurately detected on CT-like MRI (n = 22, κ 1.00 (95% CI 1.00-1.00)). There was no statistically significant difference in the assessment of the fracture dislocation (axial mean difference (MD) 0.06 mm, p = 0.93, coronal MD, 0.08 mm, p = 0.89 and sagittal MD, 0.04 mm, p = 0.96). The agreement for the fracture classification as well as the inter- and intra-rater agreement was excellent (range κ 0.92-0.98 (95% CI 0.96-0.99)). CONCLUSION: Assessment of mandibular fractures was feasible and accurate using CT-like MRI based on a 3D T1 GRE sequence and is comparable to conventional CT. CLINICAL RELEVANCE: For the assessment of acute mandibular fractures, CT-like MRI might become a useful alternative to CT in order to reduce radiation exposure particularly in young patients.


Assuntos
Fraturas Mandibulares , Masculino , Feminino , Humanos , Adulto Jovem , Estudos de Viabilidade , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X
9.
Eur J Nucl Med Mol Imaging ; 49(11): 3870-3877, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35606526

RESUMO

BACKGROUND AND PURPOSE: Treatment of oral squamous cell carcinoma (OSCC) is based on clinical exam, biopsy, and a precise imaging-based TNM-evaluation. A high sensitivity and specificity for magnetic resonance imaging (MRI) and F-18 FDG PET/CT are reported for N-staging. Nevertheless, staging of oral squamous cell carcinoma is most often based on computed tomography (CT) scans. This study aims to evaluate cost-effectiveness of MRI and PET/CT compared to standard of care imaging in initial staging of OSCC within the US Healthcare System. METHODS: A decision model was constructed using quality-adjusted life years (QALYs) and overall costs of different imaging strategies including a CT of the head, neck, and the thorax, MRI of the neck with CT of the thorax, and whole body F-18 FDG PET/CT using Markov transition simulations for different disease states. Input parameters were derived from literature and willingness to pay (WTP) was set to US $100,000/QALY. Deterministic sensitivity analysis of diagnostic parameters and costs was performed. Monte Carlo modeling was used for probabilistic sensitivity analysis. RESULTS: In the base-case scenario, total costs were at US $239,628 for CT, US $240,001 for MRI, and US $239,131 for F-18 FDG PET/CT whereas the model yielded an effectiveness of 5.29 QALYs for CT, 5.30 QALYs for MRI, and 5.32 QALYs for F-18 FDG PET/CT respectively. F-18 FDG PET/CT was the most cost-effective strategy over MRI as well as CT, and MRI was the cost-effective strategy over CT. Deterministic and probabilistic sensitivity analysis showed high robustness of the model with incremental cost effectiveness ratio remaining below US $100,000/QALY for a wide range of variability of input parameters. CONCLUSION: F-18 FDG PET/CT is the most cost-effective strategy in the initial N-staging of OSCC when compared to MRI and CT. Despite less routine use, both whole body PET/CT and MRI are cost-effective modalities in the N-staging of OSCC. Based on these findings, the implementation of PET/CT for initial staging could be suggested to help reduce costs while increasing effectiveness in OSCC.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Análise Custo-Benefício , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Imageamento por Ressonância Magnética , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/patologia , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Tomografia Computadorizada por Raios X
10.
Respir Res ; 22(1): 119, 2021 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-33892720

RESUMO

BACKGROUND: In the absence of PCR detection of SARS-CoV-2 RNA, accurate diagnosis of COVID-19 is challenging. Low-dose computed tomography (CT) detects pulmonary infiltrates with high sensitivity, but findings may be non-specific. This study assesses the diagnostic value of SARS-CoV-2 serology for patients with distinct CT features but negative PCR. METHODS: IgM/IgG chemiluminescent immunoassay was performed for 107 patients with confirmed (group A: PCR + ; CT ±) and 46 patients with suspected (group B: repetitive PCR-; CT +) COVID-19, admitted to a German university hospital during the pandemic's first wave. A standardized, in-house CT classification of radiological signs of a viral pneumonia was used to assess the probability of COVID-19. RESULTS: Seroconversion rates (SR) determined on day 5, 10, 15, 20 and 25 after symptom onset (SO) were 8%, 25%, 65%, 76% and 91% for group A, and 0%, 10%, 19%, 37% and 46% for group B, respectively; (p < 0.01). Compared to hospitalized patients with a non-complicated course (non-ICU patients), seroconversion tended to occur at lower frequency and delayed in patients on intensive care units. SR of patients with CT findings classified as high certainty for COVID-19 were 8%, 22%, 68%, 79% and 93% in group A, compared with 0%, 15%, 28%, 50% and 50% in group B (p < 0.01). SARS-CoV-2 serology established a definite diagnosis in 12/46 group B patients. In 88% (8/9) of patients with negative serology > 14 days after symptom onset (group B), clinico-radiological consensus reassessment revealed probable diagnoses other than COVID-19. Sensitivity of SARS-CoV-2 serology was superior to PCR > 17d after symptom onset. CONCLUSIONS: Approximately one-third of patients with distinct COVID-19 CT findings are tested negative for SARS-CoV-2 RNA by PCR rendering correct diagnosis difficult. Implementation of SARS-CoV-2 serology testing alongside current CT/PCR-based diagnostic algorithms improves discrimination between COVID-19-related and non-related pulmonary infiltrates in PCR negative patients. However, sensitivity of SARS-CoV-2 serology strongly depends on the time of testing and becomes superior to PCR after the 2nd week following symptom onset.


Assuntos
COVID-19/sangue , COVID-19/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Cuidados Críticos/estatística & dados numéricos , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Imunoglobulina G/análise , Imunoglobulina M/análise , Masculino , Pessoa de Meia-Idade , Pandemias , Reação em Cadeia da Polimerase , Estudos Retrospectivos , Soroconversão , Testes Sorológicos , Tomografia Computadorizada por Raios X , Adulto Jovem
11.
Eur Radiol ; 31(8): 6069-6077, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33507353

RESUMO

OBJECTIVES: To compare spinal bone measures derived from automatic and manual assessment in routine CT with dual energy X-ray absorptiometry (DXA) in their association with prevalent osteoporotic vertebral fractures using our fully automated framework ( https://anduin.bonescreen.de ) to assess various bone measures in clinical CT. METHODS: We included 192 patients (141 women, 51 men; age 70.2 ± 9.7 years) who had lumbar DXA and CT available (within 1 year). Automatic assessment of spinal bone measures in CT included segmentation of vertebrae using a convolutional neural network (CNN), reduction to the vertebral body, and extraction of bone mineral content (BMC), trabecular and integral volumetric bone mineral density (vBMD), and CT-based areal BMD (aBMD) using asynchronous calibration. Moreover, trabecular bone was manually sampled (manual vBMD). RESULTS: A total of 148 patients (77%) had vertebral fractures and significantly lower values in all bone measures compared to patients without fractures (p ≤ 0.001). Except for BMC, all CT-based measures performed significantly better as predictors for vertebral fractures compared to DXA (e.g., AUC = 0.885 for trabecular vBMD and AUC = 0.86 for integral vBMD vs. AUC = 0.668 for DXA aBMD, respectively; both p < 0.001). Age- and sex-adjusted associations with fracture status were strongest for manual vBMD (OR = 7.3, [95%] CI 3.8-14.3) followed by automatically assessed trabecular vBMD (OR = 6.9, CI 3.5-13.4) and integral vBMD (OR = 4.3, CI 2.5-7.6). Diagnostic cutoffs of integral vBMD for osteoporosis (< 160 mg/cm3) or low bone mass (160 ≤ BMD < 190 mg/cm3) had sensitivity (84%/41%) and specificity (78%/95%) similar to trabecular vBMD. CONCLUSIONS: Fully automatic osteoporosis screening in routine CT of the spine is feasible. CT-based measures can better identify individuals with reduced bone mass who suffered from vertebral fractures than DXA. KEY POINTS: • Opportunistic osteoporosis screening of spinal bone measures derived from clinical routine CT is feasible in a fully automatic fashion using a deep learning-driven framework ( https://anduin.bonescreen.de ). • Manually sampled volumetric BMD (vBMD) and automatically assessed trabecular and integral vBMD were the best predictors for prevalent vertebral fractures. • Except for bone mineral content, all CT-based bone measures performed significantly better than DXA-based measures. • We introduce diagnostic thresholds of integral vBMD for osteoporosis (< 160 mg/cm3) and low bone mass (160 ≤ BMD < 190 mg/cm3) with almost equal sensitivity and specificity compared to conventional thresholds of quantitative CT as proposed by the American College of Radiology (osteoporosis < 80 mg/cm3).


Assuntos
Osteoporose , Fraturas da Coluna Vertebral , Absorciometria de Fóton , Idoso , Densidade Óssea , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Osteoporose/epidemiologia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/epidemiologia , Tomografia Computadorizada por Raios X
12.
J Clin Periodontol ; 48(7): 929-948, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33745132

RESUMO

AIM: To evaluate the correlation between standard clinical findings, radiographic (OPT) and magnetic resonance imaging (MRI) as well as to assess whether MRI is capable of providing additional information related to the severity and extent of periodontal disease. METHODS: 42 patients with generalized periodontitis received pre-interventional MRI scans. These were compared to MR images of a periodontal healthy control group (n = 34). The extent of the osseous oedema, detected by MRI, was set in correlation with clinical periodontitis-associated findings. RESULTS: A highly significant correlation between bone oedema and clinical testings such as probing depth (p < 0.0001) and bleeding on probing (p < 0.0001) was revealed. The oedema exceeded the extent of demineralized bone. Patients with a positive BOP test showed a 2.51-fold increase in risk of already having a bone oedema around the respective tooth even if probing depth was ≤3 mm (logistic binary regression analysis, OR 2.51; 95% CI: 1.54-4.11; p < 0.0001). CONCLUSION: MRI findings correlated with standard clinical findings, and MRI was able to depict intraosseous changes before any osseous defect had occurred.


Assuntos
Doenças Periodontais , Periodontite , Humanos , Imageamento por Ressonância Magnética , Periodontite/diagnóstico por imagem , Estudos Prospectivos
13.
J Oral Maxillofac Surg ; 79(5): 1045-1052, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33358707

RESUMO

PURPOSE: The pathophysiology and treatment of medication-related osteonecrosis of the jaws (MRONJ) remain unclear after nearly two decades of recorded observation and discussion. The purpose of this study was to assess outcomes of surgical resection of MRONJ in patients exposed to denosumab. MATERIALS AND METHODS: A literature review was performed in conjunction with experts at the University of Illinois at Chicago Library. The primary outcome of interest was surgical success defined by maintenance of complete mucosal closure without bone exposure and infection after surgical resection. Secondary interests included demographics, MRONJ stage, location of the focus of osteonecrosis, and the primary underlying disease necessitating antiresorptive treatment. Statistical analysis was performed by χ2, analysis of variance, or t test (P < .05 and b = 0.2 or a power of 0.8). RESULTS: A total of 70 articles were identified and 14 met inclusion criteria. Twenty patients were included (13 women; 7 men); age 61.8 years ± 12.9 (range 19 to 77); and MRONJ stage I (40.0%), II (35.0%), and III (25.0%). Most cases occurred in the mandible (65.0%), followed by the maxilla (30.0%). The success rate of surgical intervention for MRONJ secondary to denosumab was in 16 of 20 (80.0%) patients. Stage I MRONJ lesions achieved mucosal closure in 100% of patients, stage II in 71.4%, and stage III in 60.0%. The surgical success rate was 83.3% in the maxilla and 76.9% in the mandible. CONCLUSIONS: The surgical success rate for MRONJ secondary to denosumab was 80.0%, similar to that reported in bisphosphonates of 85 to 95%; however, more evidence must be reported and analyzed.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/cirurgia , Conservadores da Densidade Óssea/efeitos adversos , Chicago , Denosumab/efeitos adversos , Difosfonatos , Feminino , Humanos , Arcada Osseodentária , Masculino , Pessoa de Meia-Idade
14.
Medicina (Kaunas) ; 57(5)2021 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-34065104

RESUMO

Medication-related osteonecrosis of the jaw (MRONJ) has become a well-known side effect of antiresorptive, and antiangiogenic drugs commonly used in cancer management. Despite a considerable amount of literature addressing MRONJ, it is still widely accepted that the underlying pathomechanism of MRONJ is unclear. However, several clinical and preclinical studies indicate that infection seems to have a major role in the pathogenesis of MRONJ. Although there is no conclusive evidence for the infection hypothesis yet, available data have shown a robust association between local infection and MRONJ development. This observation is very critical in order to implement policies to reduce the risk of MRONJ in patients under antiresorptive drugs. This critical review was conducted to collect the most reliable evidence regarding the link between local infection and MRONJ pathogenesis.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Neoplasias , Inibidores da Angiogênese , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/tratamento farmacológico , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/epidemiologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/uso terapêutico , Humanos , Neoplasias/tratamento farmacológico
15.
Clin Oral Investig ; 24(8): 2625-2634, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31705309

RESUMO

OBJECTIVE: Since MRI using dedicated imaging sequences has recently shown promising results in direct visualization of the inferior alveolar nerve (IAN) and the lingual nerve (LN) with high spatial resolution, the aim of this study was to generate suitable standard specifications to reliably depict the IAN and LN in MRI and to delineate the anatomy and its variants of these nerves in healthy subjects. METHODS: Thirty healthy volunteers were examined on a 3-T scanner (Elition, Philips Healthcare, Best, the Netherlands). The sequence protocol consisted of 3D STIR, 3D DESS, and 3D T1 FFE "black bone" sequences. RESULTS: The study reconfirmed a good feasibility of direct visualization of proximal and peripheral portions of the IAN and of the proximal course of the LN. The STIR sequence showed the highest apparent signal to noise ratio (aSNR) and best apparent nerve-muscle contrast to noise ratio (aNMCNR) for IAN and for the LN. The applied MRI sequences allowed to differentiate the tissue composition of the neurovascular bundle inside the mandibular canal. CONCLUSION: Dedicated MRI sequence protocols proved effectively to detect the IAN and LN and their course in healthy volunteers. The tissue composition of the mandibular neurovascular bundle was conclusively distinguishable as was the varying topography inside multiple bony channels. CLINICAL RELEVANCE: The presented data on the precise and valid visualization of the IAN and LN have clinical implications in respect to local anesthesia prior to dental treatments in the mandible but also regarding surgical procedures and implant insertion in the molar region.


Assuntos
Nervo Lingual , Nervo Mandibular , Benchmarking , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Mandíbula , Países Baixos , Traumatismos do Nervo Trigêmeo
16.
BMC Musculoskelet Disord ; 20(1): 152, 2019 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-30961552

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is the modality of choice for diagnosing and monitoring muscular tissue pathologies and bone marrow alterations in the context of lower back pain, neuromuscular diseases and osteoporosis. Chemical shift encoding-based water-fat MRI allows for reliable determination of proton density fat fraction (PDFF) of the muscle and bone marrow. Prior to quantitative data extraction, segmentation of the examined structures is needed. Performed manually, the segmentation process is time consuming and therefore limiting the clinical applicability. Thus, the development of automated segmentation algorithms is an ongoing research focus. CONSTRUCTION AND CONTENT: This database provides ground truth data which may help to develop and test automatic lumbar muscle and vertebra segmentation algorithms. Lumbar muscle groups and vertebral bodies (L1 to L5) were manually segmented in chemical shift encoding-based water-fat MRI and made publically available in the database MyoSegmenTUM. The database consists of water, fat and PDFF images with corresponding segmentation masks for lumbar muscle groups (right/left erector spinae and psoas muscles, respectively) and lumbar vertebral bodies 1-5 of 54 healthy Caucasian subjects. The database is freely accessible online at https://osf.io/3j54b/?view_only=f5089274d4a449cda2fef1d2df0ecc56 . CONCLUSION: A development and testing of segmentation algorithms based on this database may allow the use of quantitative MRI in clinical routine.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Bases de Dados Factuais , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sistema Musculoesquelético/diagnóstico por imagem , Músculos Paraespinais/diagnóstico por imagem , Tecido Adiposo/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema Musculoesquelético/metabolismo , Músculos Paraespinais/metabolismo , Água/metabolismo
17.
Clin Oral Investig ; 22(1): 1-27, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28616750

RESUMO

OBJECTIVES: We sought to identify oral symptoms found in hyperparathyroidism and compare their rate of occurrence, as well as potential variations in sequelae between primary, secondary, and tertiary hyperparathyroidism. MATERIALS AND METHODS: Database searches were performed through EMBASE and PubMed, with a continual handsearch for relevant articles. PRISMA guidelines were followed. RESULTS: Two hundred five articles including 245 patients were analyzed with data extraction. The average age was 34.02 years old (age range 1-83), with 91 male and 154 female patients (1:1.7 M/F ratio). Patients presented with symptoms including facial asymmetry or swelling (167/214 cases; 78.0%), oral pain (30/214; 14.0%), systemic symptoms (25/214; 11.7%), referrals or incidental findings (16/214; 7.5%), and neuropathy (6/214; 2.8%) independently and in combination together. Bony pathology occurred most often in the mandible (100/245 cases; 40.8%), while 72 cases were in the maxilla (29.4%) and 73 cases in both jaw bones (29.8%). CONCLUSIONS: Our data collection identifies a wide variation in the presentation of hyperparathyroidism. In order to be more certain of oral maladies from hyperparathyroidism, studies with large patient populations need to be conducted at healthcare centers to clarify the oral outcomes of hyperparathyroidism. CLINICAL RELEVANCE: What was thought to be a characteristic finding of HPT, mandibular radiolucency occurred in only a minor portion of cases. Furthermore, the pathognomonic sign of HPT on radiograph, loss of lamina dura, was only the third most common presentation. Bone pathology was most commonly reported in literature, but should not be assumed the only oral sequelae of hyperparathyroidism.


Assuntos
Hiperparatireoidismo/complicações , Doenças da Boca/etiologia , Humanos
18.
Sci Rep ; 14(1): 663, 2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182726

RESUMO

In clinical practice, diagnosis of suspected carious lesions is verified by using conventional dental radiography (DR), including panoramic radiography (OPT), bitewing imaging, and dental X-ray. The aim of this study was to evaluate the use of magnetic resonance imaging (MRI) for caries visualization. Fourteen patients with clinically suspected carious lesions, verified by standardized dental examination including DR and OPT, were imaged with 3D isotropic T2-weighted STIR (short tau inversion recovery) and T1 FFE Black bone sequences. Intensities of dental caries, hard tissue and pulp were measured and calculated as aSNR (apparent signal to noise ratio) and aHTMCNR (apparent hard tissue to muscle contrast to noise ratio) in both sequences. Imaging findings were then correlated to clinical examination results. In STIR as well as in T1 FFE black bone images, aSNR and aHTMCNR was significantly higher in carious lesions than in healthy hard tissue (p < 0.001). Using water-sensitive STIR sequence allowed for detecting significantly lower aSNR and aHTMCNR in carious teeth compared to healthy teeth (p = 0.01). The use of MRI for the detection of caries is a promising imaging technique that may complement clinical exams and traditional imaging.


Assuntos
Cárie Dentária , Humanos , Cárie Dentária/diagnóstico por imagem , Suscetibilidade à Cárie Dentária , Imageamento por Ressonância Magnética , Inversão Cromossômica , Nível de Saúde
19.
Clin Neuroradiol ; 33(1): 187-197, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35881162

RESUMO

OBJECTIVE: Here we compare the procedural and clinical outcome of patients undergoing thrombectomy with running thrombolysis to matched controls with completed intravenous therapy and an only marginally overlapping activity. METHODS: Patients from 25 sites in Germany were included, who presented with an acute ischemic stroke. Patients' baseline characteristics (including ASPECTS, NIHSS and mRS), grade of reperfusion, and functional outcome 24 h and at day 90 after intervention were extracted from the German Stroke Registry (n = 2566). In a case-control design we stepwise matched the groups due to age, sex and time to groin puncture and time to flow restoration. RESULTS: In the initial cohort (overlap group n = 864, control group n = 1702) reperfusion status (median TICI in overlap group vs. control group: 3 vs. 2b), NIHSS after 24 h, early neurological improvement parameters, mRS at 24 h and at day 90 were significantly better in the overlap group (p < 0.001) with a similar risk of bleeding (2.9% vs. 2.4%) and death (18% vs. 22%). After adjustment mRS at day 90 still showed a trend for lower disability scores in the overlap group (3 IQR 1-5 vs. 3 IQR 1-6, p = 0.09). While comparable bleeding risk could be maintained (4% in both groups), there were significantly more deaths in the control group (18% vs. 30%, p = 0.006). CONCLUSION: The presented results support the approach of continuing and completing a simultaneous administration of intravenous thrombolysis during mechanical thrombectomy procedures.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , AVC Isquêmico/etiologia , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Trombectomia/métodos , Terapia Trombolítica , Sistema de Registros , Estudos de Casos e Controles
20.
Quant Imaging Med Surg ; 13(9): 5472-5482, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37711780

RESUMO

Background: To investigate reproducibility of texture features and volumetric bone mineral density (vBMD) extracted from trabecular bone in the thoracolumbar spine in routine clinical multi-detector computed tomography (MDCT) data in a single scanner environment. Methods: Patients who underwent two routine clinical thoraco-abdominal MDCT exams at a single scanner with a time interval of 6 to 26 months (n=203, 131 males; time interval mean, 13 months; median, 12 months) were included in this observational study. Exclusion criteria were metabolic and hematological disorders, bone metastases, use of bone-active medications, and history of osteoporotic vertebral fractures (VFs) or prior diagnosis of osteoporosis. A convolutional neural network (CNN)-based framework was used for automated spine labeling and segmentation (T5-L5), asynchronous Hounsfield unit (HU)-to-BMD calibration, and correction for the intravenous contrast medium phase. Vertebral vBMD and six texture features [varianceglobal, entropy, short-run emphasis (SRE), long-run emphasis (LRE), run-length non-uniformity (RLN), and run percentage (RP)] were extracted for mid- (T5-T8) and lower thoracic (T9-T12), and lumbar vertebrae (L1-L5), respectively. Relative annual changes were calculated in texture features and vBMD for each vertebral level and sorted by sex, and changes were checked for statistical significance (P<0.05) using paired t-tests. Root mean square coefficient of variation (RMSCV) and root mean square error (RMSE) were calculated as measures of variability. Results: SRE, LRE, RLN, and RP exhibited substantial reproducibility with RMSCV-values below 2%, for both sexes and at all spine levels, while vBMD was less reproducible (RMSCV =11.9-16.2%). Entropy showed highest variability (RMSCV =4.34-7.69%) due to statistically significant increases [range, mean ± standard deviation: (4.40±5.78)% to (8.36±8.66)%, P<0.001]. RMSCV of varianceglobal ranged from 1.60% to 3.03%. Conclusions: Opportunistic assessment of texture features in a single scanner environment using the presented CNN-based framework yields substantial reproducibility, outperforming vBMD reproducibility. Lowest scan-rescan variability was found for higher-order texture features. Further studies are warranted to determine, whether microarchitectural changes to the trabecular bone may be assessed through texture features.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA