Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Alzheimers Dement ; 20(2): 1284-1297, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37985230

RESUMO

INTRODUCTION: Blood biomarkers have proven useful in Alzheimer's disease (AD) research. However, little is known about their biological variation (BV), which improves the interpretation of individual-level data. METHODS: We measured plasma amyloid beta (Aß42, Aß40), phosphorylated tau (p-tau181, p-tau217, p-tau231), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL) in plasma samples collected weekly over 10 weeks from 20 participants aged 40 to 60 years from the European Biological Variation Study. We estimated within- (CVI ) and between-subject (CVG ) BV, analytical variation, and reference change values (RCV). RESULTS: Biomarkers presented considerable variability in CVI and CVG . Aß42/Aß40 had the lowest CVI (≈ 3%) and p-tau181 the highest (≈ 16%), while others ranged from 6% to 10%. Most RCVs ranged from 20% to 30% (decrease) and 25% to 40% (increase). DISCUSSION: BV estimates for AD plasma biomarkers can potentially refine their clinical and research interpretation. RCVs might be useful for detecting significant changes between serial measurements when monitoring early disease progression or interventions. Highlights Plasma amyloid beta (Aß42/Aß40) presents the lowest between- and within-subject biological variation, but also changes the least in Alzheimer's disease (AD) patients versus controls. Plasma phosphorylated tau variants significantly vary in their within-subject biological variation, but their substantial fold-changes in AD likely limits the impact of their variability. Plasma neurofilament light chain and glial fibrillary acidic protein demonstrate high between-subject variation, the impact of which will depend on clinical context. Reference change values can potentially be useful in monitoring early disease progression and the safety/efficacy of interventions on an individual level. Serial sampling revealed that unexpectedly high values in heathy individuals can be observed, which urges caution when interpreting AD plasma biomarkers based on a single test result.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides , Proteína Glial Fibrilar Ácida , Biomarcadores , Progressão da Doença , Proteínas tau
2.
Clin Chim Acta ; 552: 117632, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37940015

RESUMO

BACKGROUND: Measurement of serum amino acid (AA) concentrations is important in particular for the diagnosis and monitoring of inborn errors of AA metabolism. To ensure optimal clinical interpretation of AAs, reliable biological variation (BV) data are essential. In the present study, we derived BV data for 22 non-essential, conditionally essential, and essential AAs and assessed differences in BV of AAs related to sex. METHODS: Morning blood samples were drawn from 66 subjects (31 males and 35 females) once a week for 10 consecutive weeks. All samples were analyzed in duplicate using liquid chromatography-tandem mass-spectrometry. The data were assessed for outliers, trends, normality and variance homogeneity analysis prior to estimating within-subject (CVI) and between-subject (CVG) BV. RESULTS: CVI estimates ranged from 9.0 % for histidine (male) to 33.0 % for taurine (male). CVI estimates in males and females were significantly different for all AAs except for aspartic acid, citrulline and phenylalanine, in most cases higher in females than in males. Apart from for arginine, CVG estimates in males and females were similar. CONCLUSIONS: In this highly powered BV study, we provide updated BV estimates for 22 AAs and demonstrate that for most AAs, CVI estimates differ between males and females, with implications for interpretation and use of AAs in clinical practice.


Assuntos
Aminoácidos , Caracteres Sexuais , Feminino , Humanos , Masculino , Aminoácidos/sangue
3.
Biochem Med (Zagreb) ; 32(2): 020709, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35799986

RESUMO

Introduction: The Fourth Universal Definition of Myocardial Infarction Global Taskforce recommends the use of high sensitive troponin (hs-Tn) assays in the diagnosis of acute myocardial infarction. We evaluated the analytical performance of the Atellica IM High-sensitivity Troponin I Assay (hs-TnI) (Siemens Healthcare Diagnostics Inc., Tarrytown, USA) and compared its performance to other hs-TnI assays (Siemens Advia Centaur, Dimension Vista, Dimension EXL, and Abbott Architect (Wiesbaden, Germany)) at one or more sites across Europe. Materials and methods: Precision, detection limit, linearity, method comparison, and interference studies were performed according to Clinical and Laboratory Standards Institute protocols. Values in 40 healthy individuals were compared to the manufacturer's cut-offs. Sample turnaround time (TAT) was examined. Results: Imprecision repeatability CVs were 1.1-4.7% and within-lab imprecision were 1.8-7.6% (10.0-25,000 ng/L). The limit of blank (LoB), detection (LoD), and quantitation (LoQ) aligned with the manufacturer's values of 0.5 ng/L, 1.6 ng/L, and 2.5 ng/L, respectively. Passing-Bablok regression demonstrated good correlations between Atellica IM analyser with other systems; some minor deviations were observed. All results in healthy volunteers fell below the 99th percentile URL, and greater than 50% of each sex demonstrated values above the LoD. No interference was observed for biotin (≤ 1500 µg/L), but a slight bias at 5.0 g/L haemoglobin and 50 ng/L Tn was observed. TAT from was fast (mean time = 10.9 minutes) and reproducible (6%CV). Conclusions: Real-world analytical and TAT performance of the hs-TnI assay on the Atellica IM analyser make this assay fit for routine use in clinical laboratories.


Assuntos
Bioensaio , Troponina I , Testes de Coagulação Sanguínea , Europa (Continente) , Humanos , Laboratórios
4.
Arch Pathol Lab Med ; 144(10): 1209-1216, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32649215

RESUMO

CONTEXT.­: Point-of-care testing allows rapid analysis and short turnaround times. To the best of our knowledge, the present study assesses, for the first time, clinical, operative, and economic outcomes of point-of-care blood gas analysis in a nephrology department. OBJECTIVE.­: To evaluate the impact after implementing blood gas analysis in the nephrology department, considering clinical (differences in blood gas analysis results, critical results), operative (turnaround time, elapsed time between consecutive blood gas analysis, preanalytical errors), and economic (total cost per process) outcomes. DESIGN.­: A total amount of 3195 venous blood gas analyses from 688 patients of the nephrology department before and after point-of-care blood gas analyzer installation were included. Blood gas analysis results obtained by ABL90 FLEX PLUS were acquired from the laboratory information system. Statistical analyses were performed using SAS 9.3 software. RESULTS.­: During the point-of-care testing period, there was an increase in blood glucose levels and a decrease in pCO2, lactate, and sodium as well as fewer critical values (especially glucose and lactate). The turnaround time and the mean elapsed time were shorter. By the beginning of this period, the number of preanalytical errors increased; however, no statistically significant differences were found during year-long monitoring. Although there was an increase in the total number of blood gas analysis requests, the total cost per process decreased. CONCLUSIONS.­: The implementation of a point-of-care blood gas analysis in a nephrology department has a positive impact on clinical, operative, and economic terms of patient care.


Assuntos
Gasometria/economia , Nefropatias/sangue , Nefrologia/economia , Sistemas Automatizados de Assistência Junto ao Leito/economia , Testes Imediatos/economia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA