RESUMO
OBJECTIVES: To conduct a systematic review on the translucency of bulk-fill (BF) composite materials, evaluating the factors influencing it and its clinical implications. MATERIALS AND METHODS: A systematic search was performed on four databases (Embase, Medline/PubMed, Scopus, and Web of Science) for articles published until October 2, 2023. Search terms were: "translucency," "translucency parameter," "contrast," "contrast ratio," "bulk," "bulk-fill," "bulk fill," "composite," "resin," "resin based," "resin-based," "restoration," and "dental." In vitro studies, written in English language, investigating BF resin-based composites translucency were included. The risk of bias was performed with the RoBDEMAT tool. RESULTS: Of 590 screened articles, 13 were included in this review. They investigated 11 high-viscosity BF and 5 low viscosity ones. The limited number of the identified studies and the heterogeneity of the extracted data did not allow to conduct a meta-analysis. CONCLUSIONS: BF materials exhibit variability in translucency due to variations in experimental designs and the heterogeneous composition. CLINICAL SIGNIFICANCE: BFs may behave differently in masking the substrate or in blending capacity.
Assuntos
Resinas Compostas , Resinas Compostas/química , Humanos , Teste de Materiais , Restauração Dentária Permanente/métodos , Materiais Dentários/químicaRESUMO
OBJECTIVES: To conduct a scoping review on color stability of bulk-fill compared to conventional resin-based composites exposed to colored beverages. MATERIALS AND METHODS: In vitro studies, investigating bulk-fill resin-based composites color stability submitted to artificial staining by colored beverages were included. Studies investigating color change induced by smoke and whitening treatments as well as papers not written in English language were excluded. A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) was performed on four databases (Embase, Medline, Scopus, Web of Science) for articles published until October 01st 2022. The study selection was then performed by two authors who screened the abstracts independently and followed the JBI approach. RESULTS: Of 717 screened abstracts, 59 were selected for full-text analysis. Finally, 19 studies were included in this review. They investigated 19 different bulk-fill composites and different artificial-staining-by-liquids-protocols including coffee, red wine, tea, coke, and others. Seven papers reported higher color change in the investigated bulk fill materials than in conventional resin-based composites, while nine studies reported the opposite. SonicFill showed the highest color stability for most of the papers. CONCLUSIONS: The available evidence suggests that bulk-fill materials show variability in color stability. This behavior can be attributed to the heterogeneity of composition and staining procedures in the selected studies. CLINICAL SIGNIFICANCE: Clinicians should keep in mind that bulk-fill materials may change color when exposed to colorant drinks or food.
Assuntos
Café , Materiais Dentários , Teste de Materiais , Coloração e RotulagemRESUMO
OBJECTIVE: To conduct a systematic review on color stability of dental resin-based composites (RBC) exposed to conventional and electronic cigarettes. MATERIALS AND METHODS: In vitro studies reporting on the color stability of RBC exposed to conventional cigarettes or to e-cigarettes: both Tobacco Heating Systems (THS) and Electronic Nicotine Delivery Systems (ENDS). The quality of the included studies was assessed with the QUIN tool (risk-of-bias tool for assessing in vitro studies conducted in dentistry). A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) was performed on four (n = 4) databases (Embase, Medline, Scopus, Web of Science) for articles published until March 28th, 2022. RESULTS: Of the 365 screened articles, 13 were included in this review. All the included articles analyzed conventional cigarette smoke (CS), four analyzed Electronic Nicotine Delivery Systems (ENDS) and two Tobacco Heating Systems (THS). In terms of study design, smoke exposure time, smoke flow, type and number of cigarettes a high variability was reported. CONCLUSIONS: The available evidence suggests that CS smoke significantly affects color stability. Electronic cigarettes show less color change that seems to be easily recovered under clinical acceptability thresholds, although evidence is scarce. CLINICAL SIGNIFICANCE: Clinicians should be aware, and should therefore warn their patients, that RBCs are subjected to irreversible color change if exposed to smoke. Electronic cigarettes (both ENDS and THS) induce less color change that can be recovered with repolishing or whitening procedures.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Humanos , Materiais Dentários , Nicotiana , FumarRESUMO
OBJECTIVE: The objective of this study was to review the experimental staining procedures performed in in-vitro studies for evaluating color stability of resin-based composites used for direct restorations. OVERVIEW: A review was performed with the purpose to identify in vitro procedures carried out to establish staining and color stability of resin-based composites used for direct restorations. A literature search was performed on four online databases (PubMed, Scopus, Embase and Web of Science) for articles published from January 1st 2001 till March 20th 2021, using a combination of free words and Medical Subject Headings (MESH) terms: "Composite Resins" AND "Color Stability" OR "Staining." Two reviewers screened titles and/or abstracts of 1728 unique studies. In total, 208 studies were selected for full-text reading, from which 178 were included in the review. The assessed variables were specimen dimensions, shape, and surface finishing; time before immersion; staining media type, dwell time, temperature and renewal interval; type of composite; color and translucency assessment parameters and measuring system. One hundred and seventy-eight articles analyzed color stability with staining liquids. Coffee was the most used staining medium (n = 102), followed by tea (n = 61), and red wine (n = 55). A disc-shaped specimen was used in most studies (n = 170) with a 2 mm thickness (n = 116). Spectrophotometers were the most used color assessment devices (n = 154), followed by colorimeters (n = 17). Color differences were quantified with ΔE (n = 154), ΔE00 (n = 23). Acceptability and or perceptibility thresholds were also taken into consideration (n = 126). CONCLUSIONS: The large variety of staining procedure suggests the need for standardization. CLINICAL SIGNIFICANCE: Aesthetic failure due to discoloration is a relevant clinical problem. Evaluating benefits and drawbacks of resin based composites artificial staining procedures will improve to predict materials clinical performances.
Assuntos
Materiais Dentários , Cor , Teste de Materiais , Coloração e Rotulagem , Propriedades de SuperfícieRESUMO
Background: Rotary Ni-Ti files are susceptible to sudden intra-canal separation due to cyclic fatigue stress, particularly in curved canals. To increase resistance to cyclic fatigue, new heat-treated files have been introduced. This study aimed to compare the performance of four heat-treated Ni-Ti files in two simulated curved root canals by evaluating the effect of the alloy, rotation speed, and diameter of the files on their resistance to cyclic fatigue. Methods: The Ni-Ti files included in the study were the ProTaper Gold® (Dentsply Sirona) F2, ProTaper Ultimate® (Dentsply Sirona) F2, FQ® (Komet) 25.06, and Blueshaper® (Zarc4Endo) Z4 25.06. Two groups of 30 files were selected for each system and were tested in two simulated canals milled in a specific metal template. One group was tested in a 60° curved canal and the other in a 90° curved canal. Results: In the 60° simulated canal, there were no instrument fractures within the 15 min time limit. In the 90° simulated canal, the Blueshaper Z4 demonstrated a lower resistance to cyclic fatigue, while FQ 25.06 showed statistically higher fatigue resistance based on both the Kruskal-Wallis and Games-Howell tests (p < 0.05). Conclusions: No differences were found between files when tested in a 60° curved canal for up to 15 min. However, in a 90° canal, the FQ® files showed significantly higher resistance to cyclic fatigue, especially compared to the Blueshaper® Z4. The ProTaper Ultimate and ProTaper Gold produced intermediate results, with the ProTaper Ultimate F2 slightly outperforming the ProTaper Gold F2.
RESUMO
In recent years, the continuous evolution of dental resin-based composites (RBCs) has led to various restorative improvements, allowing for reliable clinical results together with excellent esthetics.1 A composite material can be defined as a union of two or more insoluble phases. From this union, a material with superior characteristics compared to the single components is produced. The main elements of dental RBCs are the organic resin matrix and inorganic filler particles.
Assuntos
Resinas Compostas , Estética Dentária , Teste de Materiais , Materiais Dentários , Propriedades de SuperfícieRESUMO
BACKGROUND: To evaluate the effect of different experimental staining procedures on color stability and translucency of a nano-hybrid resin-based composite (RBC). METHODS: Forty-eight cylindrical-shaped specimens (10 × 2 mm) were prepared with a nano-hybrid RBC (Clearfil Majesty ES-2) and randomly divided in four groups according to the experimental staining procedure: G1) static immersion in a staining solution (coffee) (44 ± 1 °C); G2) staining cycling between coffee (44 ± 1°C) and distilled water (37 ± 1°C) with an experimental staining machine based on Arduino, an Open Source hardware development platform; G3) staining cycles as in G2 + brushing with a low abrasive toothpaste (Relative Dentin Abrasion RDA = 30) (Elmex Sensitive Professional); G4) staining cycles as in G3, with brushing performed with a very strong abrasive toothpaste (RDA = 90) (Lacult Active). Color parameters were recorded at the baseline (T0) after staining procedures (T1) and repolishing (T2) using a spectrophotometer. Color change (∆E00) and translucency (TP, CR) were evaluated. Data were statistically analyzed (p < 0.05). RESULTS: For ∆E00 after staining, Group 1 showed the highest color change and Group 3 the lowest. All groups were significantly different (p < 0.001) except for Group 2 vs. Group 4; after repolishing, Group 1 was significantly higher than Group 3 (p < 0.001), Group 2 (p < 0.001), and Group 4 (p = 0.003); Group 2 was higher than Group 3 (p < 0.001). For TP variable, after staining procedures, Group 2 was significantly higher than all other groups (p < 0.001), and Group 1 was significantly higher than Group 3 (p < 0.001) and Group 4 (p = 0.007). After repolishing, Group 4 was significantly lower than Group 3 (p = 0.008) and Group 2 (p = 0.027). Repolishing procedure significantly reduced color parameters. CONCLUSIONS: The investigated staining procedure induced significant differences in color stability and translucency. The use of a very strong abrasive toothpaste (RDA = 90) induced higher color change than a low abrasive one (RDA = 30). Repolishing procedures are able to partially reduce color change induced by artificial staining procedures.
RESUMO
BACKGROUND: This systematic review aims to evaluate the color stability of resin composite CAD/CAM blocks (CCB) when submitted to staining solutions. METHODS: A systematic search was performed on different databases (Embase, Medline, Scopus, Web of Science). Search terms were: 'polymer infiltrated', 'polymer-based', 'resin nanoceramic', 'resin ceramic', 'hybrid composite', 'hybrid ceramic', 'composite ceramic', 'resin infiltrated', 'CAD-CAM', 'CAD/CAM', 'color stability', 'staining', 'staining susceptibility', 'color change', 'color difference'. INCLUSION CRITERIA: in vitro articles published in the English language until 18 September 2022 without initial time restriction evaluating the color stability of CCB when submitted to staining solutions. EXCLUSION CRITERIA: studies investigating color change induced by smoke or whitening treatments; studies not including a clinical evaluation of the results using the thresholds for color perceptibility and acceptability. Risk of bias assessment using the QUIN tool. FINDINGS: Out of the 378 initially retrieved articles, 19 were included in this review. They investigated 17 different CCBs and different artificial staining by liquid protocols, including coffee, red wine, tea, and cola. CCBs exceeded clinical acceptability thresholds for color shift in 18 out of 19 studies, with a significantly higher color stability than conventional hybrid resin-based composites (RBCs), and a significantly lower color stability than ceramic materials. The identified differences in CCBs in color stability can be attributed to the material's composition, but also to the heterogeneity of staining procedures. Interpretation and clinical implication: Clinicians should be aware that, although to a lower degree when compared to RBCs used in direct or indirect procedures, CCBs undergo color changes to a higher degree in comparison to ceramic materials.
RESUMO
Fulfilling a patient's request for a healthy, functional and esthetic smile represents a daily challenge for dental practitioners [...].
RESUMO
The long-term survival of restorations in the oral cavity has always been one of the most significant challenges in modern dental practice [...].
RESUMO
The objective of this study was to review the experimental in vitro procedures employed to assess the color stability of resin-based composites exposed to smoke. A literature search was performed on four databases (Pubmed, Scopus, Embase, and Web of Science). The quality of the included papers was assessed with the Cochrane risk-of-bias tool (RoB 2). In total, 25 studies were selected for full-text reading, from which 12 were included in the review. The assessed variables were: dimensions, shape, time before exposure, finishing, smoke-type, exposure time, brushing simulation, color, measuring system, repolishing. A disk-shaped specimen was used in most studies (n=10) with a 2 mm thickness (n=7) in custom made devices equipped with vacuum pumps or in Vitrocell systems. Spectrophotometers were the most used devices (n=11). Color differences were quantified with ΔE (n=12), ΔE00 (n=1). The large variety of staining procedures suggests the need for standardization.
Assuntos
Resinas Compostas , Materiais Dentários , Cor , Propriedades de Superfície , Fumar , Teste de MateriaisRESUMO
Several lubricant materials can be used to model resin-based composites (RBCs) during restorative procedures. Clinically, instruments or brushes are wet with bonding agents (BAs) or modeling liquids (MLs) for sculpturing purposes. However, a knowledge gap exists on their effects on the mechanical properties of RBCs, requiring greater insight. Five databases were searched, including 295 in vitro studies on the use of lubricant materials for modeling RBCs during restorative procedures. Only articles in the English language were included, with no limits on the publication date. The last piece of research was dated 24 March 2022. In total, 16 studies were included in the review process, together with a paper retrieved after screening references. A total of 17 BAs and 7 MLs were investigated. Tensile (n = 5), flexural strength (n = 2), water sorption (n = 2), color stability (n = 8) and translucency (n = 3), micro-hardness (n = 4), roughness (n = 3), degree of conversion (n = 3), and monomer elution (n = 2) tests were carried out. In general, a maximum of 24 h of artificial storage was performed (n = 13), while four papers tested the specimens immediately. The present review identifies the possibilities and limitations of modeling lubricants used during restorative procedures on the mechanical, surface, and optical properties of RBCs. Clinicians should be aware that sculpturing RBCs with modeling resins might influence the composite surface properties in a way that is material-dependent.
RESUMO
BACKGROUND: COVID-19 pandemic has disrupted the daily work of the dental professionals, assuming unprecedented economic, managerial, and psychological implications. The aim of this cross-sectional survey was to analyze the extent of the impact linked to the imposed working conditions on the Italian dental team. METHODS: The survey was administered with a web-based form (Google Forms®; Google LLC, Mountain View, CA, USA) to Italian dentists and hygienists. To be enrolled in the study, participants had to reach the adulthood and agree to sign the privacy policy. The impact of COVID-19 was analyzed through a 27-items questionnaire, which was divided into 4 main domains: personal protective equipment (PPE), operative procedures, secretarial organization, and self-reported quality of life (including e-learning appraisal). RESULTS: A total of 614 between dentists and dental hygienists completed the questionnaire. Compared to the prepandemic period, the use of PPE such as face shields, surgical caps and disposable gowns were implemented after the COVID-19 outbreak. Almost the whole interviewed (99.9%) received the COVID-19 vaccine. An increased use of preoperatory mouthwashes and rubber dam was referred during the pandemic, while aerosolization (i.e., ultrasound) was drastically reduced. A certain number of respondents (30% dentists, 27% hygienists) suffered from work-related stresses during the pandemic until they desired to change jobs. E-learning was considered beneficial for the 70% of participants. CONCLUSIONS: COVID-19 pandemic influenced dental professionals' life, leading to a rearrangement of professional, managerial, and cultural life for both dentists and hygienists even after 1 year from the outbreak.
Assuntos
COVID-19 , Adulto , COVID-19/epidemiologia , Vacinas contra COVID-19 , Estudos Transversais , Odontólogos/psicologia , Humanos , Pandemias/prevenção & controle , Qualidade de Vida , SARS-CoV-2RESUMO
In esthetic restorations of anterior teeth the clinician has to manage several aspects in order to have a predictable outcome. A deep knowledge of the anatomy as well as the adhesive procedures and the optical properties of resin-based composites are mandatory to achieve esthetic results. Contemporary restorative materials present either several shades and different translucency properties and therefore they are able to mimic teeth's optical behavior thus providing a natural aspect to anterior restorations. The wrong thickness of different composite layers may provide unpleasant results such as low value (grayish) restorations that often requires reintervention. A precise step-by-step procedure is therefore mandatory to provide the proper shade at the correct place. There is therefore the need of some corrections and adjustments during the layer procedure in order to avoid errors in shade positioning that could affect final result. The authors present a case series (six clinical cases) treated with the proposed technique with up to five years follow-up.
RESUMO
This study evaluated the pitting corrosion resistance of nickel-titanium (NiTi) rotary instruments with different surface treatments in 17% ethylenediaminetetraacetic acid (EDTA) and NaCl solutions. Electropolished RaCe instruments were allocated to group A, non-electropolished RaCe instruments to group B, and physical vapor deposition (PVD)-coated Alpha files to group C (10 instruments per group). Electrochemical measurements were carried out by using a potentiostat for galvanic current measurements. On the basis of electrochemical tests, no localized corrosion problems are to be expected in EDTA. In NaCl, pitting potential occurred at higher values for the electropolished and PVD instruments, indicating an increased corrosion resistance. There appears to be a risk of corrosion for NiTi instruments without surface treatments in contact with NaCl. NiTi files with PVD and electropolishing surface treatments showed an increase corrosion resistance.
Assuntos
Quelantes/química , Ligas Dentárias/química , Ácido Edético/química , Níquel/química , Preparo de Canal Radicular/instrumentação , Cloreto de Sódio/química , Titânio/química , Materiais Revestidos Biocompatíveis/química , Corrosão , Polimento Dentário , Eletroquímica , Desenho de Equipamento , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Polarografia , Potenciometria , Propriedades de Superfície , TemperaturaRESUMO
BACKGROUND: The efficacy of endodontic irrigation procedures can be compromised by the complexity of the root canal system. Delivering irrigants to the apical third of curved canals presents a particular challenge to endodontists. This study compared the effects of two ultrasonic irrigation techniques on the penetration of sodium hypochlorite into the main canal and simulated lateral canals of curved roots in extracted teeth. MATERIAL AND METHODS: Two sets of simulated lateral canals were created at 2, 4, and 6 mm from the working length in 60 single-rooted teeth (6 canals/tooth, n = 360 canals). The teeth were randomly divided into three experimental irrigation groups: group 1 (n = 20), positive pressure irrigation (PPI); group 2 (n = 20), passive ultrasonic irrigation (PUI); and group 3 (n = 20), continuous ultrasonic irrigation (CUI). To assess the irrigation solution penetration, 20% Chinese ink (Sanford Rotring GmbH, Hamburg, Germany) was added to a 5% sodium hypochlorite solution and delivered into the curved root canals. The penetration of contrast solution into the simulated lateral canals was scored by counting the number of lateral canals (0-2) penetrated to at least 50% of the total length. RESULTS: The CUI group showed significantly higher (P < 0.05) irrigant penetration into the lateral canals and into the apical third of the main canals. The PPI group showed significantly lower sodium hypochlorite penetration (P < 0.001) into the main and lateral canals compared with that in the CUI and PUI groups. Significantly higher irrigant penetration was observed in the PUI group than the PPI group. CONCLUSIONS: Using CUI as the final rinse significantly increased the penetration of irrigant solution into the simulated lateral canals and apical third of curved roots. Key words:Continuous ultrasonic irrigation, curved root canals, passive ultrasonic irrigation, positive pressure irrigation, root canal irrigation.
RESUMO
BACKGROUND: Scientific studies show a possible influence of intercellular and intracellular proteins (VEGF) on the development of physiological and pathological tissue. VEGF, a key regulator of angiogenesis, it would seem essential to take action during the embryonic development of the dental germ. The purpose of the study is to investigate the importance of the enzymatic activity of VEGF through protein quantification at different stages of tooth germ development. METHODS: The quantification of VEGF protein was performed by 3 different laboratory tests: Western-blot analysis, semi-quantitative reverse transcriptase-polymerase chain reaction analysis (RT-PCR) and finally immunohistochemical analysis. Cell cultures of tooth tissue examined are: endothelial cells, stellate reticulum cells, odontoblasts and ameoblast. RESULTS: The VEGF peptide seems to induce an intense cell proliferation, not concomitant with differentiation towards the endothelial line. The expression of VEGF in the inner enamel epithelium (ameloblasts) would seem to depend on the stage of differentiation, leading us to deduce that VEGF and its respective receptor are expressed in dental germ and that induce alterations not only on the vascularization, but also on the inner epithelium activation and then on dental enamel development, respectively on cap and bell stages of embryogenesis. CONCLUSIONS: In our survey, the positive expression of VEGF in all the samples examined, might suggest a fundamental role of angiogenic gene proteins during all stages of embryonic tooth development. It is also characteristic the behavior of stellate reticulum cells, with a significant reduction in VEGF action between early and late stage, which could suggest a possible role of stellate reticulum cells, which would be able to promote and maintain an adequate energy supply to the tissues during early and late stages of differentiation and proliferation.
Assuntos
Germe de Dente/metabolismo , Fator A de Crescimento do Endotélio Vascular/análise , Adolescente , Ameloblastos/metabolismo , Western Blotting , Criança , Células Endoteliais/metabolismo , Feminino , Regulação da Expressão Gênica no Desenvolvimento , Humanos , Masculino , Odontoblastos/metabolismo , RNA Mensageiro/biossíntese , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Germe de Dente/crescimento & desenvolvimento , Fator A de Crescimento do Endotélio Vascular/biossíntese , Adulto JovemRESUMO
The dual purpose of this study was, to evaluate the fracture rate of Ni-Ti rotary instruments when following a manual glide path and using stainless steel hand files before carrying out instrumentation by means of rotary files and, to compare the results in this study with those obtained in two previous analyses, in which the glide path technique was not used. A total of 208 canals obtained from a pool of freshly extracted human mandibular and maxillary molars was divided into three groups corresponding to; K3, ProFile and ProTaper. The coronal 2/3 of each tooth were used. In all three groups the apical portion of the samples was prepared with size 10-20 stainless steel K-type hand files. The apical stops were prepared using K3, ProFile and ProTaper rotary instruments. Logistic regression model analysis indicated that breakage was significantly associated with the angle of curvature of the canal (OR = 1.078; 95% CI = 1.032-1.12; p = 0.001), and with the number of clinical uses (files used more than eight times broke more frequently that those used 1 or 2 times; OR: 22.686; 95% CI: 2.6-191.3; p = 0.004). The breakage rate obtained in the present study is significantly lower than in our previous studies, in which the angle of curvature was also greater than 30 degrees and rotational speed a constant 350 rpm, but in which the canals were not first prepared with hand files (25/205 = 12% versus 16/61 = 26%, p = 0.007). Based on the results of this study, we recommend the use of stainless steel hand files to prepare the apical 1/3 of curved canals before introducing rotary files.
Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Ligas Dentárias , Cavidade Pulpar/anatomia & histologia , Falha de Equipamento , Reutilização de Equipamento , Humanos , Modelos Logísticos , Dente Molar , Níquel , Aço Inoxidável , Titânio , Ápice DentárioRESUMO
OBJECTIVE: The aim of this study was to compare the scanning electron microscopic (SEM) morphology of root canal walls instrumented manually and mechanically with and without the application of Er:YAG laser. METHODS: Single-rooted, human, extracted teeth were cut at the cementoenamel junction. The teeth were divided into four groups: teeth that were simply instrumented manually, those that were instrumented manually and laser treated, a group that was mechanically instrumented, and a fourth in which the teeth were mechanically instrumented and laser treated. After instrumentation, the teeth were split longitudinally to facilitate their evaluation by SEM. RESULTS: The results show that the use of the Er:YAG laser is effective in removing the smear layer from root canal walls. CONCLUSIONS: The removal of the smear layer is essential to the success of endodontic treatment; the use of the Er:YAG laser combined with rotary and manual techniques improves the cleanliness of root canals.
Assuntos
Cavidade Pulpar/ultraestrutura , Terapia a Laser , Tratamento do Canal Radicular/instrumentação , Dente , Desenho de Equipamento , Segurança de Equipamentos , Érbio , Humanos , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Probabilidade , Distribuição Aleatória , Tratamento do Canal Radicular/métodos , Estudos de Amostragem , Sensibilidade e Especificidade , ÍtrioRESUMO
INTRODUCTION: This prospective randomized clinical trial evaluated the incidence of postoperative pain after glide path performed with PathFile (PF) (Dentsply Maillefer, Ballaigues, Switzerland) versus stainless-steel K-file (KF). METHODS: In 149 subjects, the mechanical glide path was performed with nickel-titanium (NiTi) rotary PF; in 146 subjects, the manual glide path was performed with stainless-steel KFs. Postoperative pain, analgesics consumption, and the number of days to complete pain resolution were evaluated in the following 7 days. An analysis of variance model for repeated measures was used to compare the variation of pain-scale values (P < .05). The Student's t test for continuous variables normally distributed, the nonparametric Mann-Whitney U test for the nonnormally distributed variables, and the chi-square test for dichotomous variables were used (P < .05). Despite homogeneous baseline conditions at diagnosis, tooth type, pain prevalence, and scores, the postoperative pain prevalence curves in PF group evidenced a more favorable trend in terms of time to pain resolution compared with the KF group (P = .004). The difference was also evident in the model adjusted for analgesics consumption in both groups (P = .012). The mean analgesics intake per subject was significantly higher in the KF group (3.7 ± 2.2) compared with the PF group (2 ± 1.7) (P < .001). Mean pain stop values were also significantly higher in the KF group (2.7) compared with the PF group (1.7) (P = .001). CONCLUSIONS: The glide path with NiTi Rotary PF leads to less postoperative pain and faster symptom resolution.