RESUMO
OBJECTIVES: As cervical cancer screening programs are implemented and expanded, an increasing number of women require loop electrosurgical excision procedure (LEEP) for treatment of pre-invasive cervical disease. Our objective was to describe the pathological results of LEEP specimens performed as part of the MULHER study and identify factors associated with positive LEEP margins. METHODS: The MULHER study enrolled 9014 women who underwent HPV testing followed by visual assessment for treatment (VAT) using visual inspection with acetic acid (VIA) and thermal ablation for those with positive results. Participants with lesions ineligible for ablation underwent LEEP. Pathology reports were reviewed for specimen size/volume, number of fragments, pathological diagnosis and margin status. Multivariable regression analysis was performed to identify variables associated with positive LEEP margins. RESULTS: 169 participants underwent LEEP. The median age was 38 years (range 30-49). 65.1% were women living with HIV. Pathological diagnosis was available for 154 patients and included cancer (n=6, 3.9%); cervical intraepithelial neoplasia (CIN) 2/3 (n=75, 48.7%); CIN 1 (n=67, 43.5%); and normal/benign findings (n=6,3.9%). 31.8% of LEEP specimens were removed in more than one fragment. The mean specimen volume was 2.9 cm3 (range 0.2-15.0). LEEP margin status was available for 130 patients. Positive margins (ectocervical/endocervical only, or both) were noted in 76 (58.5%) patients and associated with HIV+status (p=0.0499) and a diagnosis of CIN 2 or worse (p=0.0197). There were no associations between margin status and age, number of fragments or specimen volume. CONCLUSION: Our results showed a high number of LEEP specimens with positive margins. Additional evaluation is needed to better understand the characteristics of precancerous cervical lesions in this high-risk population. As cervical cancer screening programs are scaled in Mozambique and other lower-resource countries, there is a need to train providers to perform high-quality LEEP and for accurate and timely pathological interpretation.
RESUMO
OBJECTIVE: To evaluate cervical cancer screening with primary human papillomavirus (HPV) testing in Mozambique, a country with one of the highest burdens of cervical cancer globally. METHODS: Women aged 30-49 years were prospectively enrolled and offered primary HPV testing using either self-collected or provider-collected specimens. Patients who tested positive for HPV underwent visual assessment for treatment using visual inspection with acetic acid to determine eligibility for thermal ablation. If ineligible, they were referred for excision with a loop electrosurgical excision procedure, for cold knife conization, or for cervical biopsy if malignancy was suspected. RESULTS: Between January 2020 and January 2023, 9014 patients underwent cervical cancer screening. Median age was 37 years (range 30-49) and 4122 women (45.7%) were patients living with HIV. Most (n=8792, 97.5%) chose self-collection. The HPV positivity rate was 31.1% overall and 39.5% among patients living with HIV. Of the 2805 HPV-positive patients, 2588 (92.3%) returned for all steps of their diagnostic work-up and treatment, including ablation (n=2383, 92.1%), loop electrosurgical excision procedure (n=169, 6.5%), and cold knife conization (n=5, 0.2%). Thirty-one patients (1.2%) were diagnosed with cancer and referred to gynecologic oncology. CONCLUSION: It is feasible to perform cervical cancer screening with primary HPV testing and follow-up in low-resource settings. Participants preferred self-collection, and the majority of screen-positive patients completed all steps of their diagnostic work-up and treatment. Our findings provide important information for further implementation and scale-up of cervical cancer screening and treatment services as part of the WHO global strategy for the elimination of cervical cancer.
Assuntos
Infecções por HIV , Infecções por Papillomavirus , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/cirurgia , Neoplasias do Colo do Útero/prevenção & controle , Infecções por Papillomavirus/diagnóstico , Detecção Precoce de Câncer/métodos , Moçambique/epidemiologia , Papillomaviridae , Programas de Rastreamento/métodos , Infecções por HIV/diagnósticoRESUMO
Cervical cancer remains a leading cause of cancer death for women in low- and middle-income countries. The goal of our study was to evaluate screening and triage strategies, including high-resolution microendoscopy (HRME), to detect cervical abnormalities concerning for precancer at the point of care. Women (n = 1824) were enrolled at the Instituto de Cáncer de El Salvador. All underwent screening by both human papillomavirus (HPV) testing using careHPV and visual inspection with acetic acid (VIA). Screen-positives, along with 10% of screen-negatives, were invited to return for a follow-up examination that included triage with VIA, colposcopy and HRME imaging. Biopsies were taken of any abnormalities identified. If no abnormalities were identified, then the worst scoring site by HRME was biopsied. The sensitivities of HPV testing and VIA to screen for cervical intraepithelial neoplasia Grade 2 or more severe diagnoses (CIN2+) were 82.1% and 75% (P = .77), while the specificities were 90.4% and 80.9% (P < .001), respectively. The sensitivities of VIA, colposcopy and HRME as triage tests for CIN2+ were 82.1%, 82.1% and 71.4%, respectively (P ≥ .38). HRME had a significantly higher specificity (66.7%) than VIA (51.9%) (P < .001) and colposcopy (53.3%) (P < .001). When evaluating different theoretical screening and triage strategies, screening with HPV testing followed by triage with HRME would result in more women receiving appropriate care (97%) compared to screening with VIA (75%) or HPV alone (90%). Our findings demonstrate that screening with HPV is superior to VIA, and that triage with HRME imaging increases the specificity of detecting CIN2+ at the point of care in a low-resource setting.
RESUMO
Line-scanning confocal microendoscopy offers video-rate cellular imaging of scattering tissue with relatively simple hardware, but its axial response is inferior to that of point-scanning systems. Based on Fourier optics theory, we designed differential confocal apertures with a simple subtraction technique to improve the line-scanning sectioning performance. Taking advantage of digital slit apertures on a digital light projector and a CMOS rolling shutter, we demonstrate real-time optical sectioning performance comparable to point scanning in a dual-camera microendoscope (<$6,000). We validate the background rejection capability when imaging porcine columnar epithelium stained with fluorescent contrast agents with different uptake mechanisms and staining properties.
RESUMO
Fiber-optic endomicroscopy is a minimally invasive tool to probe disease progression with subcellular resolution. In this Letter, we demonstrate a low-cost and compact fluorescence microendoscope capable of line-scanning confocal imaging by synchronizing a digital light projector with a CMOS camera. We present the digital aperture design to enable real-time confocal imaging, and we implement parallel illumination to improve the optical sectioning performance. Furthermore, we show that the confocal microendoscope can enhance visualization of disease-associated features when imaging highly scattering esophageal specimens.
Assuntos
Custos e Análise de Custo , Endoscópios/economia , Microscopia Confocal/economia , Microscopia Confocal/instrumentação , Esôfago/diagnóstico por imagem , Humanos , Fibras Ópticas , Fatores de TempoRESUMO
BACKGROUND: Optical detection of circulating haemozoin has been suggested as a needle free method to diagnose malaria using in vivo microscopy. Haemozoin is generated within infected red blood cells by the malaria parasite, serving as a highly specific, endogenous biomarker of malaria. However, phagocytosis of haemozoin by white blood cells which persist after the infection is resolved presents the potential for false positive diagnosis; therefore, the focus of this work is to identify a feature of the haemozoin signal to discriminate between infected red blood cells and haemozoin-containing white blood cells. METHODS: Conventional brightfield microscopy of thin film blood smears was used to analyse haemozoin absorbance signal in vitro. Cell type and parasite maturity were morphologically determined using colocalized DAPI staining. The ability of features to discriminate between infected red blood cells and haemozoin-containing white blood cells was evaluated using images of smears from subjects infected with two species of Plasmodium, Plasmodium yoelii and Plasmodium falciparum. Discriminating features identified by blood smear microscopy were characterized in vivo in P. yoelii-infected mice. RESULTS: Two features of the haemozoin signal, haemozoin diameter and normalized intensity difference, were identified as potential parameters to differentiate infected red blood cells and haemozoin-containing white blood cells. Classification performance was evaluated using the area under the receiver operating characteristic curve, with area under the curve values of 0.89 for the diameter parameter and 0.85 for the intensity parameter when assessed in P. yoelii samples. Similar results were obtained from P. falciparum blood smears, showing an AUC of 0.93 or greater for both classification features. For in vivo investigations, the intensity-based metric was the best classifier, with an AUC of 0.91. CONCLUSIONS: This work demonstrates that size and intensity features of haemozoin absorbance signal collected by in vivo microscopy are effective classification metrics to discriminate infected red blood cells from haemozoin-containing white blood cells. This reduces the potential for false positive results associated with optical imaging strategies for in vivo diagnosis of malaria based on the endogenous biomarker haemozoin.
Assuntos
Testes Diagnósticos de Rotina/métodos , Eritrócitos/parasitologia , Hemeproteínas/análise , Microscopia Intravital , Leucócitos/parasitologia , Malária/diagnóstico , Humanos , Microscopia Intravital/estatística & dados numéricosRESUMO
Significance: Fiber-optic microendoscopy is a promising approach to noninvasively visualize epithelial nuclear morphometry for early cancer and precancer detection. However, the broader clinical application of this approach is limited by a lack of topical contrast agents available for in vivo use. Aim: The aim of this study was to evaluate the ability to image nuclear morphometry in vivo with a novel fiber-optic microendoscope used together with topical application of methylene blue (MB), a dye with FDA approval for use in chromoendoscopy in the gastrointestinal tract. Approach: The low-cost, high-resolution microendoscope implements scanning darkfield imaging without complex optomechanical components by leveraging programmable illumination and the rolling shutter of the image sensor. We validate the integration of our system and MB staining for visualizing epithelial cell nuclei by performing ex vivo imaging on fresh animal specimens and in vivo imaging on healthy volunteers. Results: The results indicate that scanning darkfield imaging significantly reduces specular reflection and resolves epithelial nuclei with enhanced image contrast and spatial resolution compared to non-scanning widefield imaging. The image quality of darkfield images with MB staining is comparable to that of fluorescence images with proflavine staining. Conclusions: Our approach enables real-time microscopic evaluation of nuclear patterns and has the potential to be a powerful noninvasive tool for early cancer detection.
Assuntos
Azul de Metileno , Azul de Metileno/química , Animais , Humanos , Núcleo Celular , Tecnologia de Fibra Óptica/instrumentação , Desenho de Equipamento , Endoscopia/métodos , Endoscopia/instrumentação , Administração TópicaRESUMO
Esophageal carcinoma is the sixth-leading cause of cancer death worldwide. A precursor to esophageal adenocarcinoma (EAC) is Barrett's Esophagus (BE). Early-stage diagnosis and treatment of esophageal neoplasia (Barrett's with high-grade dysplasia/intramucosal cancer) increase the five-year survival rate from 10% to 98%. BE is a global challenge; however, current endoscopes for early BE detection are costly and require extensive infrastructure for patient examination and sedation. We describe the design and evaluation of the first prototype of ScanCap, a high-resolution optical endoscopy system with a reusable, low-cost tethered capsule, designed to provide high-definition, blue-green illumination imaging for the early detection of BE in unsedated patients. The tethered capsule (12.8 mm diameter, 35.5 mm length) contains a color camera and rotating mirror and is designed to be swallowed; images are collected as the capsule is retracted manually via the tether. The tether provides electrical power and illumination at wavelengths of 415 nm and 565 nm and transmits data from the camera to a tablet. The ScanCap prototype capsule was used to image the oral mucosa in normal volunteers and ex vivo esophageal resections; images were compared to those obtained using an Olympus CV-180 endoscope. Images of superficial capillaries in intact oral mucosa were clearly visible in ScanCap images. Diagnostically relevant features of BE, including irregular Z-lines, distorted mucosa, and dilated vasculature, were clearly visible in ScanCap images of ex vivo esophageal specimens.
RESUMO
OBJECTIVE: Early detection and treatment of cervical precancers can prevent disease progression. However, in low-resource communities with a high incidence of cervical cancer, high equipment costs and a shortage of specialists hinder preventative strategies. This manuscript presents a low-cost multiscale in vivo optical imaging system coupled with a computer-aided diagnostic system that could enable accurate, real-time diagnosis of high-grade cervical precancers. METHODS: The system combines portable colposcopy and high-resolution endomicroscopy (HRME) to acquire spatially registered widefield and microscopy videos. A multiscale imaging fusion network (MSFN) was developed to identify cervical intraepithelial neoplasia grade 2 or more severe (CIN 2+). The MSFN automatically identifies and segments the ectocervix and lesions from colposcopy images, extracts nuclear morphology features from HRME videos, and integrates the colposcopy and HRME information. RESULTS: With a threshold value set to achieve sensitivity equal to clinical impression (0.98 [p = 1.0]), the MSFN achieved a significantly higher specificity than clinical impression (0.75 vs. 0.43, p = 0.000006). CONCLUSION: Our findings show that multiscale optical imaging of the cervix allows the highly sensitive and specific detection of high-grade precancers. SIGNIFICANCE: The multiscale imaging system and MSFN could facilitate the accurate, real-time diagnosis of cervical precancers in low-resource settings.
Assuntos
Colposcopia , Neoplasias do Colo do Útero , Feminino , Humanos , Colposcopia/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Imagem Óptica/métodos , Lesões Pré-Cancerosas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Displasia do Colo do Útero/diagnóstico por imagem , Displasia do Colo do Útero/patologia , Microscopia/métodos , Colo do Útero/diagnóstico por imagem , Colo do Útero/patologia , Adulto , Sensibilidade e EspecificidadeRESUMO
INTRODUCTION: In the United States, the effectiveness of anal cancer screening programs has been limited by a lack of trained professionals proficient in high-resolution anoscopy (HRA) and a high patient lost-to-follow-up rate between diagnosis and treatment. Simplifying anal intraepithelial neoplasia grade 2 or more severe (AIN 2+) detection could radically improve the access and efficiency of anal cancer prevention. Novel optical imaging providing point-of-care diagnoses could substantially improve existing HRA and histology-based diagnosis. This work aims to demonstrate the potential of high-resolution microendoscopy (HRME) coupled with a novel machine learning algorithm for the automated, in vivo diagnosis of anal precancer. METHODS: The HRME, a fiber-optic fluorescence microscope, was used to capture real-time images of anal squamous epithelial nuclei. Nuclear staining is achieved using 0.01% wt/vol proflavine, a topical contrast agent. HRME images were analyzed by a multitask deep learning network (MTN) that computed the probability of AIN 2+ for each HRME image. RESULTS: The study accrued data from 77 people living with HIV. The MTN achieved an area under the receiver operating curve of 0.84 for detection of AIN 2+. At the AIN 2+ probability cutoff of 0.212, the MTN achieved comparable performance to expert HRA impression with a sensitivity of 0.92 ( P = 0.68) and specificity of 0.60 ( P = 0.48) when using histopathology as the gold standard. DISCUSSION: When used in combination with HRA, this system could facilitate more selective biopsies and promote same-day AIN2+ treatment options by enabling real-time diagnosis.
Assuntos
Neoplasias do Ânus , Infecções por HIV , Humanos , Papillomavirus Humano , Canal Anal , Neoplasias do Ânus/complicações , Neoplasias do Ânus/diagnóstico , Neoplasias do Ânus/patologia , Biópsia , Infecções por HIV/complicações , Infecções por HIV/patologiaRESUMO
Cancer continues to affect underserved populations disproportionately. Novel optical imaging technologies, which can provide rapid, non-invasive, and accurate cancer detection at the point of care, have great potential to improve global cancer care. This article reviews the recent technical innovations and clinical translation of low-cost optical imaging technologies, highlighting the advances in both hardware and software, especially the integration of artificial intelligence, to improve in vivo cancer detection in low-resource settings. Additionally, this article provides an overview of existing challenges and future perspectives of adapting optical imaging technologies into clinical practice, which can potentially contribute to novel insights and programs that effectively improve cancer detection in low-resource settings.
RESUMO
Characterization of microvascular changes during neoplastic progression has the potential to assist in discriminating precancer and early cancer from benign lesions. Here, we introduce a novel high-resolution microendoscope that leverages scanning darkfield reflectance imaging to characterize angiogenesis without exogenous contrast agents. Scanning darkfield imaging is achieved by coupling programmable illumination with a complementary metal-oxide semiconductor (CMOS) camera rolling shutter, eliminating the need for complex optomechanical components and making the system portable, low-cost (<$5,500) and simple to use. Imaging depth is extended by placing a gradient-index (GRIN) lens at the distal end of the imaging fiber to resolve subepithelial microvasculature. We validated the capability of the scanning darkfield microendoscope to visualize microvasculature at different anatomic sites in vivo by imaging the oral cavity of healthy volunteers. Images of cervical specimens resected for suspected neoplasia reveal distinct microvascular patterns in columnar and squamous epithelium with different grades of precancer, indicating the potential of scanning darkfield microendoscopy to aid in efforts to prevent cervical cancer through early diagnosis.
RESUMO
Significance: Despite recent advances in multimodal optical imaging, oral imaging systems often do not provide real-time actionable guidance to the clinician who is making biopsy and treatment decisions. Aim: We demonstrate a low-cost, portable active biopsy guidance system (ABGS) that uses multimodal optical imaging with deep learning to directly project cancer risk and biopsy guidance maps onto oral mucosa in real time. Approach: Cancer risk maps are generated based on widefield autofluorescence images and projected onto the at-risk tissue using a digital light projector. Microendoscopy images are obtained from at-risk areas, and multimodal image data are used to calculate a biopsy guidance map, which is projected onto tissue. Results: Representative patient examples highlight clinically actionable visualizations provided in real time during an imaging procedure. Results show multimodal imaging with cancer risk and biopsy guidance map projection offers a versatile, quantitative, and precise tool to guide biopsy site selection and improve early detection of oral cancers. Conclusions: The ABGS provides direct visible guidance to identify early lesions and locate appropriate sites to biopsy within those lesions. This represents an opportunity to translate multimodal imaging into real-time clinically actionable visualizations to help improve patient outcomes.
Assuntos
Neoplasias Bucais , Imagem Óptica , Humanos , Imagem Óptica/métodos , Detecção Precoce de Câncer/métodos , Neoplasias Bucais/diagnóstico , Biópsia , Mucosa Bucal/patologiaRESUMO
Neonatal jaundice is an important cause of morbidity and mortality worldwide, and neonates born in low and middle-income countries bear a disproportionate burden. We previously developed a low-cost, point-of-care system to measure total serum bilirubin (TSB) in neonates. This device was effective at detecting and monitoring jaundice; however, the disposable strips were difficult to produce at scale. Here, we report a new lateral flow cassette design, called BiliDx, that was produced at scale using traditional manufacturing techniques. We evaluated the performance of BiliDx at sites in Nigeria and Malawi. The lateral flow strip consists of plasma separation membranes, nitrocellulose, and a plastic cassette. We evaluated the performance of the strips and reader at two hospitals located in Nigeria and Malawi compared to reference standard TSB. We also assessed performance for samples with high direct bilirubin (DB) and high hematocrit (HCT). We collected 1,144 samples from 758 neonates (TSB ranged from 0.2 to 45.9 mg/dL). The mean bias of BiliDx measurements in the validation set was +0.75 mg/dL, and 95% limits of agreement were -2.57 to 4.07 mg/dL. The mean bias and limits of agreement were comparable for samples with HCT < 60% and HCT ≥ 60%, and for samples with low and intermediate DB levels; the samples with high DB levels had wider 95% limits of agreement (-4.50 to +3.03 mg/dL). Error grid analysis shows that 96.9% of samples measured with BiliDx would have resulted in the same clinical decision as the reference standard. This performance is comparable to previous results that used a handmade two-dimensional strip. Additionally, error grid analysis shows that all 20 samples with high DB levels would have resulted in the same clinical decision as the reference standard. This evaluation supports the use of BiliDx lateral flow cassettes to provide accurate point-of-care measurements in low-resource settings.
RESUMO
Anal cancer incidence is significantly higher in people living with HIV as HIV increases the oncogenic potential of human papillomavirus. The incidence of anal cancer in the United States has recently increased, with diagnosis and treatment hampered by high loss-to-follow-up rates. Novel methods for the automated, real-time diagnosis of AIN 2+ could enable "see and treat" strategies, reducing loss-to-follow-up rates. A previous retrospective study demonstrated that the accuracy of a high-resolution microendoscope (HRME) coupled with a deep learning model was comparable to expert clinical impression for diagnosis of AIN 2+ (sensitivity 0.92 [P = 0.68] and specificity 0.60 [P = 0.48]). However, motion artifacts and noise led to many images failing quality control (17%). Here, we present a high frame rate HRME (HF-HRME) with improved image quality, deployed in the clinic alongside a deep learning model and evaluated prospectively for detection of AIN 2+ in real-time. The HF-HRME reduced the fraction of images failing quality control to 4.6% by employing a high frame rate camera that enhances contrast and limits motion artifacts. The HF-HRME outperformed the previous HRME (P < 0.001) and clinical impression (P < 0.0001) in the detection of histopathologically confirmed AIN 2+ with a sensitivity of 0.91 and specificity of 0.87.
Assuntos
Neoplasias do Ânus , Aprendizado Profundo , Infecções por HIV , Humanos , Estados Unidos , Endoscopia , Diagnóstico por Imagem , Neoplasias do Ânus/diagnóstico por imagem , Infecções por HIV/complicaçõesRESUMO
Cervical cancer is a leading cause of cancer death for women in low-resource settings. The World Health Organization recommends that cervical cancer screening programs incorporate HPV DNA testing, but available tests are expensive, require laboratory infrastructure, and cannot be performed at the point-of-care. We developed a two-dimensional paper network (2DPN), hybrid-capture, signal amplification assay and a point-of-care sample preparation protocol to detect high-risk HPV DNA from exfoliated cervical cells within an hour. The test does not require expensive equipment and has an estimated cost of <$3 per test without the need for batching. We evaluated performance of the paper HPV DNA assay with short synthetic and genomic HPV DNA targets, HPV positive and negative cellular samples, and two sets of clinical samples. The first set of clinical samples consisted of 16 biobanked, provider-collected cervical samples from a study in El Salvador previously tested with careHPV and subsequently tested in a controlled laboratory environment. The paper HPV DNA test correctly identified eight of eight HPV-negative clinical samples and seven of eight HPV-positive clinical samples. We then performed a field evaluation of the paper HPV DNA test in a hospital laboratory in Mozambique. Cellular controls generated expected results throughout field testing with fully lyophilized sample preparation and 2DPN reagents. When evaluated with 16 residual self-collected cervicovaginal samples previously tested by the GeneXpert HPV assay ("Xpert"), the accuracy of the HPV DNA paper test in the field was reduced compared to testing in the controlled laboratory environment, with positive results obtained for all eight HPV-positive samples as well as seven of eight HPV-negative samples. Further evaluation showed reduction in performance was likely due in part to increased concentration of exfoliated cells in the self-collected clinical samples from Mozambique compared with provider-collected samples from El Salvador. Finally, a formal usability assessment was conducted with users in El Salvador and Mozambique; the assay was rated as acceptable to perform after minimal training. With additional optimization for higher cell concentrations and inclusion of an internal cellular control, the paper HPV DNA assay offers promise as a low-cost, point-of-care cervical cancer screening test in low-resource settings.
Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/prevenção & controle , Infecções por Papillomavirus/diagnóstico , Detecção Precoce de Câncer/métodos , Interface Usuário-Computador , Papillomaviridae/genética , DNARESUMO
We investigate the use of a semiconductor optical amplifier operated in the saturation regime as a phase modulator for long range laser radar applications. The nature of the phase and amplitude modulation resulting from a high peak power Gaussian pulse, and the impact this has on the ideal pulse response of a laser radar system, is explored. We also present results of a proof-of-concept laboratory demonstration using phase-modulated pulses to interrogate a stationary target.
RESUMO
From 2013-2015, a CPAP quality improvement program (QIP) was implemented to introduce and monitor CPAP usage and outcomes in the neonatal wards at all government district and central hospitals in Malawi. In 2016 the CPAP QIP was extended into healthcare facilities operated by the Christian Health Association of Malawi. Although clinical outcomes improved, ward assessments indicated that many rural sites lacked other essential equipment and a suitable space to adequately treat sick neonates, which likely limited the impact of improved respiratory care. The aim of this study was to determine if a ward-strengthening program improved outcomes for neonates treated with CPAP. To address the needs identified from ward assessments, a ward-strengthening program was implemented from 2017-2018 at rural hospitals in Malawi to improve the care of sick neonates. The ward-strengthening program included the distribution of a bundle of equipment, supplemental training, and, in some cases, health facility renovations. Survival to discharge was compared for neonates treated with CPAP at 12 rural hospitals for one year before and for one year immediately after implementation of the ward-strengthening program. In the year prior to ward strengthening, 189 neonates were treated with CPAP; in the year after, 232 neonates received CPAP. The overall rate of survival for those treated with CPAP improved from 46.6% to 57.3% after ward strengthening (p = 0.03). For the subset of neonates with admission weights between 1.00-2.49 kg diagnosed with respiratory distress syndrome, survival increased from 39.4% to 60.3% after ward strengthening (p = 0.001). A ward-strengthening program including the distribution of a bundle of equipment, supplemental training, and some health facility renovations, further improved survival among neonates treated with CPAP at district-level hospitals in Malawi.
RESUMO
OBJECTIVES: BiliSpec is a low-cost spectrophotometric reader and disposable paper-based strip to quantify total serum bilirubin from several blood drops. This study was a prospective evaluation of BiliSpec in 2 neonatal wards in Malawi compared with a reference standard bilirubinometer over a large range of bilirubin and hematocrit levels. METHODS: The accuracy of BiliSpec and a transcutaneous bilirubinometer were compared with the reference standard of spectrophotometry for 475 blood samples collected from 375 subjects across a range of total serum bilirubin concentrations from 0.0 to 33.7 mg/dL. The development of error grids to assess the clinical effects of measurement differences is reported. RESULTS: BiliSpec was found to have a mean bias of -0.48 mg/dL and 95% limits of agreement of -5.09 mg/dL to +4.12 mg/dL. Results show 90.7% of BiliSpec measurements would have resulted in the same clinical decision as the reference standard, whereas 55.0% of transcutaneous bilirubin measurements would have resulted in the same clinical decision as the reference standard. CONCLUSIONS: This evaluation supports use of BiliSpec to provide accurate, low-cost, point-of-care bilirubin measurements in low-resource hospitals. Future work is needed to evaluate BiliSpec among a larger number of users.