Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 21(17): 7109-7115, 2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34414765

RESUMO

Phonon polaritons (PhPs) in van der Waals (vdW) crystal slabs enable nanoscale infrared light manipulation. Specifically, periodically structured vdW slabs behave as polaritonic crystals (vdW-PCs), where the polaritons form Bloch modes. Because the polariton wavelengths are smaller than that of light, conventional far-field spectroscopy does not allow for a complete characterization of vdW-PCs or for revealing their band structure. Here, we perform hyperspectral infrared nanoimaging and analysis of PhPs in a vdW-PC slab made of h-BN. We demonstrate that infrared spectra recorded at individual spatial positions within the unit cell of the vdW-PC can be associated with its band structure and local density of photonic states (LDOS). We thus introduce hyperspectral infrared nanoimaging as a tool for the comprehensive analysis of polaritonic crystals, which could find applications in the reconstruction of complex polaritonic dispersion surfaces in momentum-frequency space or for exploring exotic electromagnetic modes in topological photonic structures.

2.
Nano Lett ; 17(1): 228-235, 2017 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-27966994

RESUMO

Hyperbolic polaritons in van der Waals (vdW) materials recently attract a lot of attention, owing to their strong electromagnetic field confinement, ultraslow group velocities, and long lifetimes. Typically, volume-confined hyperbolic polaritons (HPs) are studied. Here we show the first near-field optical images of hyperbolic surface polaritons (HSPs), which are confined and guided at the edges of thin flakes of a vdW material. To that end, we applied scattering-type scanning near-field optical microscopy (s-SNOM) for launching and real-space nanoimaging of hyperbolic surface phonon polariton modes on a hexagonal boron nitride (h-BN) flake. Our imaging data reveal that the fundamental HSP mode exhibits a stronger field confinement (shorter wavelength), smaller group velocities, and nearly identical lifetimes, as compared to the fundamental HP mode of the same h-BN flake. Our experimental data, corroborated by theory, establish a solid basis for future studies and applications of HPs and HSPs in vdW materials.

3.
Cardiovasc Diabetol ; 16(1): 114, 2017 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-28915818

RESUMO

BACKGROUND: Good glycaemic control in type 2 diabetes (T2DM) protects the microcirculation. Current guidelines suggest glycaemic targets be relaxed in advanced diabetes. We explored whether disease duration or pre-existing macrovascular complications attenuated the association between hyperglycaemia and microvascular function. METHODS: 743 participants with T2DM (n = 222), cardiovascular disease (CVD = 183), both (n = 177) or neither (controls = 161) from two centres in the UK, underwent standard clinical measures and endothelial dependent (ACh) and independent (SNP) microvascular function assessment using laser Doppler imaging. RESULTS: People with T2DM and CVD had attenuated ACh and SNP responses compared to controls. This was additive in those with both (ANOVA p < 0.001). In regression models, cardiovascular risk factors accounted for attenuated ACh and SNP responses in CVD, whereas HbA1c accounted for the effects of T2DM. HbA1c was associated with ACh and SNP response after adjustment for cardiovascular risk factors (adjusted standardised beta (ß) -0.096, p = <0.008 and -0.135, p < 0.001, respectively). Pre-existing CVD did not modify this association (ß -0.099; p = 0.006 and -0.138; p < 0.001, respectively). Duration of diabetes accounted for the association between HbA1c and ACh (ß -0.043; p = 0.3), but not between HbA1c and SNP (ß -0.105; p = 0.02). CONCLUSIONS: In those with T2DM and CVD, good glycaemic control is still associated with better microvascular function, whereas in those with prolonged disease this association is lost. This suggests duration of diabetes may be a better surrogate for "advanced disease" than concomitant CVD, although this requires prospective validation.


Assuntos
Glicemia/metabolismo , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/diagnóstico por imagem , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Microcirculação/fisiologia , Idoso , Doenças Cardiovasculares/epidemiologia , Estudos de Casos e Controles , Comorbidade , Diabetes Mellitus Tipo 2/epidemiologia , Feminino , Índice Glicêmico/fisiologia , Humanos , Fluxometria por Laser-Doppler/métodos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
4.
J Intern Med ; 278(3): 291-302, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25752315

RESUMO

BACKGROUND: There is a need to develop and validate surrogate markers of cardiovascular disease (CVD) in subjects with diabetes. The macrovascular changes associated with diabetes include aggravated atherosclerosis, increased arterial stiffness and endothelial dysfunction. The aim of this study was to determine which of these factors is most strongly associated with clinically manifest cardiovascular events. METHODS: Vascular changes were measured in a cohort of 458 subjects with type 2 diabetes (T2D) and CVD (myocardial infarction, stroke or lower extremity arterial disease), 527 subjects with T2D but without clinically manifest CVD and 515 subjects without T2D and with or without CVD. RESULTS: Carotid intima-media thickness (IMT) and ankle-brachial pressure index were independently associated with the presence of CVD in subjects with T2D, whereas pulse wave velocity and endothelial function provided limited independent additive information. Measurement of IMT in the carotid bulb provided better discrimination of the presence of CVD in subjects with T2D than measurement of IMT in the common carotid artery. The factors most significantly associated with increased carotid IMT in T2D were age, disease duration, systolic blood pressure, impaired renal function and increased arterial stiffness, whereas there were no or weak independent associations with metabolic factors and endothelial dysfunction. CONCLUSIONS: Measures of atherosclerotic burden are associated with clinically manifest CVD in subjects with T2D. In addition, vascular changes that are not directly related to known metabolic risk factors are important in the development of both atherosclerosis and CVD in T2D. A better understanding of the mechanisms involved is crucial for enabling better identification of CVD risk in T2D.


Assuntos
Arteriosclerose/diagnóstico por imagem , Doenças Cardiovasculares/patologia , Diabetes Mellitus Tipo 2/complicações , Idoso , Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Estudos Transversais , Diabetes Mellitus Tipo 2/patologia , Endotélio Vascular/fisiopatologia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Fatores de Risco , Rigidez Vascular/fisiologia
5.
Nanotechnology ; 26(9): 095303, 2015 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-25676599

RESUMO

Two different room-temperature processes for the electron beam induced deposition of high purity platinum (Pt), using the standard MeCpPtMe3 precursor and oxygen for purification, have been investigated. The first process is a sequential method, which uses two independent gas injector systems (GIS) in order to perform a standard Pt deposition, followed by an e-beam post-irradiation under oxygen flux. The second process is a parallel, single-step process that includes a simultaneous flow of both precursor and oxygen, using an add-on device that can be mounted on the standard GIS needle. Both processes are effective in producing high purity Pt depositions close to 100 at%. The first method requires a high current and irradiation dose in the clean-up phase, and provides Pt structures with small voids, a maximum thickness of around 100 nm and resistivity of 88 ± 10 µΩ cm. The second method requires a high oxygen/precursor flux ratio and produces void-free structures with resistivity of 60 ± 5 µΩ cm, only six times the bulk value for Pt. The second method is easier to use and produces a void-free deposition of high purity Pt.

6.
Chemphyschem ; 15(14): 3060-6, 2014 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-25111845

RESUMO

Real-time nuclear magnetic resonance (NMR) spectroscopy measurements carried out with a bench-top system installed next to the reactor inside the fume hood of the chemistry laboratory are presented. To test the system for on-line monitoring, a transfer hydrogenation reaction was studied by continuously pumping the reaction mixture from the reactor to the magnet and back in a closed loop. In addition to improving the time resolution provided by standard sampling methods, the use of such a flow setup eliminates the need for sample preparation. Owing to the progress in terms of field homogeneity and sensitivity now available with compact NMR spectrometers, small molecules dissolved at concentrations on the order of 1 mmol L(-1) can be characterized in single-scan measurements with 1 Hz resolution. Owing to the reduced field strength of compact low-field systems compared to that of conventional high-field magnets, the overlap in the spectrum of different NMR signals is a typical situation. The data processing required to obtain concentrations in the presence of signal overlap are discussed in detail, methods such as plain integration and line-fitting approaches are compared, and the accuracy of each method is determined. The kinetic rates measured for different catalytic concentrations show good agreement with those obtained with gas chromatography as a reference analytical method. Finally, as the measurements are performed under continuous flow conditions, the experimental setup and the flow parameters are optimized to maximize time resolution and signal-to-noise ratio.

7.
Phys Rev Lett ; 110(18): 180801, 2013 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-23683185

RESUMO

Permanent magnetic materials are the only magnetic source that can be used to generate magnetic fields without power consumption or maintenance. Such stand-alone magnets are very attractive for many scientific and engineering areas, but they suffer from poor temporal field stability, which arises from the strong sensitivity of the magnetic materials and mechanical support to temperature variation. In this work, we describe a highly efficient method useful to cancel the temperature coefficient of permanent magnet assemblies in a passive and accurate way. It is based on the combination of at least two units made of magnetic materials with different temperature coefficients arranged in such a way that the ratio of the fields generated by each unit matches the ratio of their effective temperature coefficients defined by both the magnetic and mechanical contributions. Although typically available magnetic materials have negative temperature coefficients, the cancellation is achieved by aligning the fields generated by each unit in the opposite direction. We demonstrate the performance of this approach by stabilizing the field generated by a dipolar Halbach magnet, recently proposed to achieve high field homogeneity. Both the field drift and the homogeneity are monitored via nuclear magnetic resonance spectroscopy experiments. The results demonstrate the compatibility of the thermal compensation approach with existing strategies useful to fine-tune the spatial dependence of the field generated by permanent magnet arrays.

8.
Phys Rev Lett ; 110(20): 203902, 2013 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-25167410

RESUMO

Theory predicts a distinct spectral shift between the near- and far-field optical response of plasmonic antennas. Here we combine near-field optical microscopy and far-field spectroscopy of individual infrared-resonant nanoantennas to verify experimentally this spectral shift. Numerical calculations corroborate our experimental results. We furthermore discuss the implications of this effect in surface-enhanced infrared spectroscopy.

9.
Nat Prod Res ; 36(5): 1405-1408, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33641558

RESUMO

Polyphenols, condensed tannins, total flavonoids, total carotenoids, lycopene and ascorbic acid were determined besides verifying antioxidant capacity of peel, pulp and desserts (with and without sugar) of red guava (Psidium guajava L.) as well as the effects of lycopene on cytotoxicity, cell cycle and apoptosis on breast cancer cell line MCF-7. Guava peel contains 90% of the total ascorbic acid and heat treatment does not modify bioactive compounds content and antioxidant capacity. Sugar addition decreased guava pulp functional capacity. After heat treatment, lycopene content was stable, but sugar addition reduced its concentration by 57%. Lycopene (10 µM) extracted from guava and standard presented the same cytotoxic effect on MCF-7 cells. Lycopene influenced over G2-M transition check-point of the cell cycle and increased apoptotic cells percentages compared to untreated cells. The consumption of in natura guava, especially with peel can be considered an important source of bioactive compounds.


Assuntos
Neoplasias da Mama , Psidium , Antioxidantes/farmacologia , Neoplasias da Mama/tratamento farmacológico , Carotenoides/farmacologia , Feminino , Humanos , Licopeno/farmacologia
10.
Monaldi Arch Chest Dis ; 71(1): 15-20, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19522160

RESUMO

BACKGROUND: Chronic obstructive lung disease (COPD) is characterised by partially reversible usually progressive airflow limitation caused by inflammation and remodelling. Stromelysin-1 (MMP-3) has regulatory activity on other matrix-metalloproteinases. Altered MMP-3 activity has been described in different diseases. We investigated the role of a promoter MMP-3 polymorphism in determining susceptibility and severity of COPD. METHODS: We studied 147 patients with COPD in stable conditions and distinguished two groups based on FEV1 values. In 100 patients functional modifications across a two-year period were noted. 133 healthy subjects were used as controls. Genotyping for the -1171 5A/6A MMP-3 polymorphism was performed using nucleotide sequencing. RESULTS: No difference was noted in the genotype distribution between COPD patients and controls. However, among patients with severe disease 6A/6A genotype and 6A allelic frequency were significantly more represented than among mild-moderate patients (p < 0.05). The 6A/6A genotype was also associated with a higher FEV1 decline over time. CONCLUSIONS: Our data suggests that -1171 6A allele does not represent a risk factor for the development of COPD while it is associated with more severe disease and different functional decline. We hypothesis that a disregulation of MMP-3, possibly caused by the -1171 5A/6A polymorphism or other linked variants, may lead to different progression in COPD.


Assuntos
Metaloproteinase 3 da Matriz/genética , Polimorfismo Genético , Doença Pulmonar Obstrutiva Crônica/genética , Idoso , Alelos , Análise de Variância , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Progressão da Doença , Feminino , Predisposição Genética para Doença , Genótipo , Humanos , Masculino , Regiões Promotoras Genéticas , Doença Pulmonar Obstrutiva Crônica/enzimologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Fatores de Risco
11.
An Pediatr (Barc) ; 71(1): 31-7, 2009 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-19464968

RESUMO

OBJECTIVE: To determine management practices of minor head trauma in children evaluated at Spanish Hospital Emergency Departments and to determine patient variables associated with intracranial injury. METHODS: Multicenter and prospective study during 18 months in 9 hospitals in Spain. Patients up to the age of 18 years with minor head trauma (Glasgow Coma Scale score higher than or equal to 13 on admission), treated in Emergency Departments and with a maximum onset of 72h since the traumatism, were included in the study. RESULTS: A total of 1070 patients were studied with a median age of 2.4 years (p25-75 0.9-6.4 years); 61.2% were male. The median time between head trauma and medical consultation was 1 hour (p25-75 0.6-2.5h). Skull X-rays were performed on 64.5% of the children and a head CT scan on 9%; 91.4% of X-ray and 84.4% of CT were normal. The prevalence of intracranial injury was 1.4% (95% CI: 0.8-2.3). Twenty-five point three percent of the patients were admitted; 4 (3.7%) required neurosurgical intervention during admission. None of the patients died. Multiple logistic regression analysis identified loss of consciousness (OR 4.2, 95% CI: 1.1-17; P=0.045), neurological deterioration (OR 8.8, 95% CI: 2.1-37.6; P=0.003) and cephalhaematoma (OR 14.6, 95% CI: 4.9-44; P <0.001) as independent predictors of intracranial injury. CONCLUSIONS: The combination of clinical parameters allows selection of patients with minor head trauma who need complementary explorations. In consequence, the routine use of skull X-ray in their initial evaluation is unnecessary.


Assuntos
Lesões Encefálicas/epidemiologia , Sistema de Registros , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Escala de Gravidade do Ferimento , Masculino , Estudos Prospectivos , Espanha
12.
Nat Commun ; 10(1): 2089, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-31064992

RESUMO

Marcus's theory of electron transfer, initially formulated six decades ago for redox reactions in solution, is now of great importance for very diverse scientific communities. The molecular scale tunability of electronic properties renders organic semiconductor materials in principle an ideal platform to test this theory. However, the demonstration of charge transfer in different Marcus regions requires a precise control over the driving force acting on the charge carriers. Here, we make use of a three-terminal hot-electron molecular transistor, which lets us access unconventional transport regimes. Thanks to the control of the injection energy of hot carriers in the molecular thin film we induce an effective negative differential resistance state that is a direct consequence of the Marcus Inverted Region.

13.
Nat Commun ; 10(1): 42, 2019 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-30604741

RESUMO

Photonic crystals (PCs) are periodically patterned dielectrics providing opportunities to shape and slow down the light for processing of optical signals, lasing and spontaneous emission control. Unit cells of conventional PCs are comparable to the wavelength of light and are not suitable for subwavelength scale applications. We engineer a nanoscale hole array in a van der Waals material (h-BN) supporting ultra-confined phonon polaritons (PhPs)-atomic lattice vibrations coupled to electromagnetic fields. Such a hole array represents a polaritonic crystal for mid-infrared frequencies having a unit cell volume of [Formula: see text] (with λ0 being the free-space wavelength), where PhPs form ultra-confined Bloch modes with a remarkably flat dispersion band. The latter leads to both angle- and polarization-independent sharp Bragg resonances, as verified by far-field spectroscopy and near-field optical microscopy. Our findings could lead to novel miniaturized angle- and polarization-independent infrared narrow-band couplers, absorbers and thermal emitters based on van der Waals materials and other thin polar materials.

14.
Nat Commun ; 10(1): 3242, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31324759

RESUMO

Launching and manipulation of polaritons in van der Waals materials offers novel opportunities for field-enhanced molecular spectroscopy and photodetection, among other applications. Particularly, the highly confined hyperbolic phonon polaritons (HPhPs) in h-BN slabs attract growing interest for their capability of guiding light at the nanoscale. An efficient coupling between free space photons and HPhPs is, however, hampered by their large momentum mismatch. Here, we show -by far-field infrared spectroscopy, infrared nanoimaging and numerical simulations- that resonant metallic antennas can efficiently launch HPhPs in thin h-BN slabs. Despite the strong hybridization of HPhPs in the h-BN slab and Fabry-Pérot plasmonic resonances in the metal antenna, the efficiency of launching propagating HPhPs in h-BN by resonant antennas exceeds significantly that of the non-resonant ones. Our results provide fundamental insights into the launching of HPhPs in thin polar slabs by resonant plasmonic antennas, which will be crucial for phonon-polariton based nanophotonic devices.

15.
J Magn Reson ; 192(1): 1-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18294890

RESUMO

Depth profiles taken from the surface of UV irradiated natural rubber sheets have been measured with microscopic resolution using a Profile NMR-MOUSE. An NMR observable related to the sum of the spin echoes in the Carr-Purcell-Meiboom-Gill pulse sequence was used to characterize the cross-link density changes produced by the action of UV radiation in each sheet. The aging process was investigated as function of irradiation time and penetration depth. An exponential attenuation law with a space dependent absorption coefficient describes the change in the NMR observable with penetration depth. An Avrami model is used to describe the dependence of the absorption coefficient on the aging time. The method can be applied to investigate the effect of various aging agents on the surfaces of elastomers.

16.
Rev Gastroenterol Mex (Engl Ed) ; 83(3): 215-222, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29706421

RESUMO

INTRODUCTION AND AIMS: Dyspepsia is a multifactorial disease that can involve alcohol, tobacco, or nonsteroidal anti-inflammatory drug use, as well as lifestyle, diet, socioeconomic elements, or psychologic factors. The aim of the present article was to establish the frequency of uninvestigated dyspepsia and determine its associated factors in students at 4 Latin American schools of medicine. MATERIALS AND METHODS: A cross-sectional, analytic study was conducted, in which a survey made up of closed-ended questions was applied at just one point in time. The association between the variables was then analyzed. A new questionnaire for the diagnosis of dyspepsia was one of the tests utilized to diagnose uninvestigated dyspepsia. Generalized linear models were used for the bivariate and multivariate analyses, employing the Poisson model with the log link function, obtaining crude prevalence ratios, adjusted prevalence ratios, and their 95% confidence intervals. RESULTS: Of the 1,241 individuals surveyed, 54% (841) were females and the median age was 21 years (range: 19-23 years). Prevalence of uninvestigated dyspepsia was 46%. The factors that had a direct association with dyspepsia were: depression, difficulty sleeping, and coffee consumption. On the contrary, eating regularly in a boarding house and the male sex had an inverse association. CONCLUSIONS: Uninvestigated dyspepsia frequency was high in students at 4 Latin American schools. Depression, difficulty sleeping, and steady coffee drinking were factors directly associated with dyspepsia, whereas male sex and eating out at regular hours were factors with a reverse association. Therefore, we recommend that universities implement early detection programs for this highly preventable pathology.


Assuntos
Dispepsia/epidemiologia , Faculdades de Medicina/estatística & dados numéricos , Estudantes de Medicina/estatística & dados numéricos , Estudos Transversais , Feminino , Humanos , América Latina , Masculino , Prevalência , Inquéritos e Questionários , Adulto Jovem
17.
Nat Commun ; 8: 15624, 2017 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-28589941

RESUMO

Polaritons in layered materials-including van der Waals materials-exhibit hyperbolic dispersion and strong field confinement, which makes them highly attractive for applications including optical nanofocusing, sensing and control of spontaneous emission. Here we report a near-field study of polaritonic Fabry-Perot resonances in linear antennas made of a hyperbolic material. Specifically, we study hyperbolic phonon-polaritons in rectangular waveguide antennas made of hexagonal boron nitride (h-BN, a prototypical van der Waals crystal). Infrared nanospectroscopy and nanoimaging experiments reveal sharp resonances with large quality factors around 100, exhibiting atypical modal near-field patterns that have no analogue in conventional linear antennas. By performing a detailed mode analysis, we can assign the antenna resonances to a single waveguide mode originating from the hybridization of hyperbolic surface phonon-polaritons (Dyakonov polaritons) that propagate along the edges of the h-BN waveguide. Our work establishes the basis for the understanding and design of linear waveguides, resonators, sensors and metasurface elements based on hyperbolic materials and metamaterials.

18.
J Magn Reson ; 180(2): 274-9, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16580238

RESUMO

The unavoidable spatial inhomogeneity of the static magnetic field generated by open sensors has precluded their use for high-resolution NMR spectroscopy. In fact, this application was deemed impossible because these field variations are usually orders of magnitude larger than those created by the microscopic structure of the molecules to be detected. Recently, chemical shift resolved NMR spectra were observed for the first time outside a portable single-sided magnet by implementing a method that exploits inhomogeneities in the rf field designed to reproduce variations of the static magnetic field. In this communication, we describe in detail the magnet system built from permanent magnets as well as the rf coil geometry used to compensate the static field variations.

19.
J Magn Reson ; 182(1): 143-51, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16843023

RESUMO

The unambiguous determination of velocities with spatial resolution in a multiecho PFG NMR sequence strongly depends on the homogeneity of the B1 field. This affects, in particular, the use of surface coils that bear considerable potential for on-line flow monitoring where a fast-imaging sequence can become vital. However, even with most rf coils dedicated for imaging applications, B1 inhomogeneities are sufficiently large to generate severe problems in performing velocity-imaging experiments. In this paper, the use of a combination of different phase cycles in Carr-Purcell sequences is discussed. The suggested phase cycling scheme tolerates large flip angle imperfections arising in inhomogeneous B1 fields, and thus allows acquisition of a maximum number of echoes within a pulse train. The performance of the velocity-imaging sequence is proven by using phantom samples developing known laminar flow patterns.

20.
J Magn Reson ; 180(2): 229-35, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16545589

RESUMO

A simple and fast method of measuring self-diffusion coefficients of protonated systems with a mobile single-sided NMR sensor is discussed. The NMR sensor uses a magnet geometry that generates a highly flat sensitive volume where a strong and highly uniform static magnetic field gradient is defined. Self-diffusion coefficients were measured by Hahn- and stimulated echoes detected in the presence of the uniform magnetic field gradient of the static field. To improve the sensitivity of these experiments, a Carr-Purcell-Meiboom-Gill pulse sequence was applied after the main diffusion-encoding period. By adding the echo train the experimental time was strongly shortened, allowing the measurement of complete diffusion curves in less than 1min. This method has been tested by measuring the self-diffusion coefficients D of various organic solvents and poly(dimethylsiloxane) samples with different molar masses. Diffusion coefficients were also measured for n-hexane absorbed at saturation in natural rubber with different cross-link densities. The results show a dependence on the concentration that is in good agreement with the theoretical prediction. Moreover, the stimulated-echo sequence was successfully used to measure the diffusion coefficient as a function of the evolution time in systems with restricted diffusion. This type of experiment proves the pore geometry and gives access to the surface-to-volume ratio. It was applied to measure the diffusion of water in sandstones and sheep Achilles tendon. Thanks to the strong static gradient G(0), all diffusion coefficients could be measured without having to account for relaxation during the pulse sequence.


Assuntos
Tendão do Calcâneo/química , Espectroscopia de Ressonância Magnética/métodos , Borracha/química , Animais , Anisotropia , Difusão , Campos Eletromagnéticos , Ovinos , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA