Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 50(2): 328-343, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36114872

RESUMO

PURPOSE: In light of recently published clinical reports and trials, the TheraSphere Global Dosimetry Steering Committee (DSC) reconvened to review new data and to update previously published clinical and dosimetric recommendations for the treatment of hepatocellular carcinoma (HCC). METHODS: The TheraSphere Global DSC is comprised of health care providers across multiple disciplines involved in the treatment of HCC with yttrium-90 (Y-90) glass microsphere-based transarterial radioembolization (TARE). Literature published between January 2019 and September 2021 was reviewed, discussed, and adjudicated by the Delphi method. Recommendations included in this updated document incorporate both the results of the literature review and the expert opinion and experience of members of the committee. RESULTS: Committee discussion and consensus led to the expansion of recommendations to apply to five common clinical scenarios in patients with HCC to support more individualized efficacious treatment with Y-90 glass microspheres. Existing clinical scenarios were updated to reflect recent developments in dosimetry approaches and broader treatment paradigms evolving for patients presenting with HCC. CONCLUSION: Updated consensus recommendations are provided to guide clinical and dosimetric approaches for the use of Y-90 glass microsphere TARE in HCC, accounting for disease presentation, tumor biology, and treatment intent.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Radioisótopos de Ítrio/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Microesferas , Compostos Radiofarmacêuticos/uso terapêutico , Embolização Terapêutica/métodos , Vidro
2.
Eur J Nucl Med Mol Imaging ; 50(3): 921-928, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36282299

RESUMO

BACKGROUND: A textbook outcome (TO) is a composite indicator covering the entire intervention process in order to reflect the "ideal" intervention and be a surrogate for patient important outcomes. Selective internal radiation therapy (SIRT) is a complex multidisciplinary and multistep intervention facing the challenge of standardization. This expert opinion-based study aimed to define a TO for SIRT of hepatocellular carcinoma. METHODS: This study involved two steps: (1) the steering committee (4 interventional radiologists) first developed an extensive list of possible relevant items reflecting an optimal SIRT intervention based on a literature review and (2) then conducted an international and multidisciplinary survey which resulted in the final TO. This survey was online, from February to July 2021, and consisted three consecutive rounds with predefined settings. Experts were identified by contacting senior authors of randomized trials, large observational studies, or studies on quality improvement in SIRT. This study was strictly academic. RESULTS: A total of 50 items were included in the first round of the survey. A total of 29/40 experts (73%) responded, including 23 interventional radiologists (79%), three nuclear medicine physicians (10%), two hepatologists, and one oncologist, from 11 countries spanning three continents. The final TO consisted 11 parameters across six domains ("pre-intervention workup," "tumor targeting and dosimetry," "intervention," "post-90Y imaging," "length of hospital stay," and "complications"). Of these, all but one were applied in the institutions of > 80% of experts. CONCLUSIONS: This multidimensional indicator is a comprehensive standardization tool, suitable for routine care, clinical round, and research.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Radiometria , Radioisótopos de Ítrio/uso terapêutico
3.
Eur J Nucl Med Mol Imaging ; 46(8): 1695-1704, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31098749

RESUMO

The TheraSphere Global Dosimetry Steering Committee was formed in 2017 by BTG International to review existing data and address gaps in knowledge related to dosimetry. This committee is comprised of health care providers with diverse areas of expertise and perspectives on radiation dosimetry. The goal of these recommendations is to optimize glass microspheres radiation therapy for hepatocellular carcinoma while accounting for variables including disease presentation, tumour vascularity, liver function, and curative/palliative intent. The recommendations aim to unify glass microsphere users behind standardized dosimetry methodology that is simple, reproducible and supported by clinical data, with the overarching goal of improving clinical outcomes and advancing the knowledge of dosimetry.


Assuntos
Conferências de Consenso como Assunto , Guias de Prática Clínica como Assunto , Radiometria/normas , Compostos Radiofarmacêuticos/normas , Radioterapia/normas , Radioisótopos de Ítrio/normas , Carcinoma Hepatocelular/radioterapia , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Compostos Radiofarmacêuticos/uso terapêutico , Radioterapia/métodos , Dosagem Radioterapêutica , Radioisótopos de Ítrio/uso terapêutico
4.
J Hepatol ; 68(4): 724-732, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29331342

RESUMO

BACKGROUND & AIMS: Yttrium-90 transarterial radioembolization (TARE) has shown promising efficacy in the treatment of patients with hepatocellular carcinoma (HCC), associated with portal vein tumor thrombus (PVTT). The aim of this study is to identify prognostic factors for survival in patients with HCC and PVTT undergoing TARE, and build a prognostic classification for these patients. METHODS: This is a single center retrospective study conducted over six years (2010-2015), on consecutive patients undergoing TARE. Patients were included if they met the following criteria: presence of at least one measurable HCC, presence of PVTT not occluding the main portal trunk, absence of extrahepatic metastases, Child-Pugh score within B7, Eastern Cooperative Oncology Group performance status 0-1. Uni- and multivariable analysis was used to explore the variables that showed an independent relationship with survival. A prognostic score was then derived, and three prognostic categories were identified. RESULTS: A total of 120 patients were included in the study. Median overall survival (OS) was 14.1 months (95% CI 10.7-17.5) and median progression-free survival (PFS) was 6.5 months (95% CI 3.8-9.2). The only variables independently correlated with OS were bilirubin, extension of PVTT and tumor burden. Three prognostic categories were identified: favourable prognosis (0 points), intermediate prognosis (2-3 points) and dismal prognosis (>3 points). Median OS in the three categories was 32.2 months, 14.9 months and 7.8 months respectively (p <0.0001). PFS (p = 0.045) and the risk of liver decompensation (p <0.0001) also significantly differed along the same prognostic categories. CONCLUSIONS: Radioembolization with Yttrium-90 is an effective therapy for patients with HCC and PVTT. The proposed prognostic stratification may help to better identify good candidates for the treatment, and those for whom TARE may be futile. LAY SUMMARY: Yttrium-90 transarterial radioembolization (TARE) is a microembolic procedure that minimizes alterations to hepatic arterial flow, and thus can be safely performed in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT). In this study, we retrospectively evaluated the independent predictors of long-term outcomes in patients with HCC and PVTT treated with TARE. Bilirubin level, extension of PVTT and tumor burden were independently related to post-treatment survival: the combination of these factors allowed us to build a prognostic stratification that may help to better identify good candidates for the treatment, and those for whom TARE may be futile.


Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Veia Porta/patologia , Radioisótopos de Ítrio/uso terapêutico , Idoso , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Prognóstico , Estudos Retrospectivos
5.
Eur J Nucl Med Mol Imaging ; 45(13): 2426-2441, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29785514

RESUMO

PURPOSE: Peptide receptor radionuclide therapy (PRRT) with 90Y-labelled and 177Lu-labelled peptides is an effective strategy for the treatment of metastatic/nonresectable neuroendocrine tumours (NETs). Dosimetry provides important information useful for optimizing PRRT with individualized regimens to reduce toxicity and increase tumour responses. However, this strategy is not applied in routine clinical practice, despite the fact that several dosimetric studies have demonstrated significant dose-effect correlations for normal organ toxicity and tumour response that can better guide therapy planning. The present study reviews the key relationships and the radiobiological models available in the literature with the aim of providing evidence that optimization of PRRT is feasible through the implementation of dosimetry. METHODS: The MEDLINE database was searched combining specific keywords. Original studies published in the English language reporting dose-effect outcomes in patients treated with PRRT were chosen. RESULTS: Nine of 126 studies were selected from PubMed, and a further five were added manually, reporting on 590 patients. The studies were analysed and are discussed in terms of weak and strong elements of correlations. CONCLUSION: Several studies provided evidence of clinical benefit from the implementation of dosimetry in PRRT, indicating the potential contribution of this approach to reducing severe toxicity and/or reducing undertreatment that commonly occurs. Prospective trials, possibly multicentre, with larger numbers of patients undergoing quantitative dosimetry and with standardized methodologies should be carried out to definitively provide robust predictive paradigms to establish effective tailored PRRT.


Assuntos
Lutécio/efeitos adversos , Lutécio/uso terapêutico , Medicina de Precisão/métodos , Radioisótopos/efeitos adversos , Radioisótopos/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Receptores de Peptídeos/metabolismo , Radioisótopos de Ítrio/efeitos adversos , Radioisótopos de Ítrio/uso terapêutico , Humanos , Dosagem Radioterapêutica
8.
Hepatology ; 57(5): 1826-37, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22911442

RESUMO

UNLABELLED: Yttrium-90 radioembolization (Y90RE) is a novel approach to radiation therapy for hepatocellular carcinoma (HCC), never tested in phase 2 studies. Fifty-two patients with intermediate (n.17) to advanced (n.35) HCC were prospectively recruited to assess, as the primary endpoint, efficacy of Y90RE on time-to-progression (TTP). Secondary endpoints were tumor response, safety, and overall survival (OS). All patients were Eastern Cooperative Oncology Group (ECOG) score 0-1, Child-Pugh class A-B7. Y90RE treatments aimed at a lobar delivery of 120 Gy. Retrospective dosimetric correlations were conducted and related to response. Fifty-eight treatments were performed on 52 patients. The median follow-up was 36 months. The median TTP was 11 months with no significant difference between portal vein thrombosis (PVT) versus no PVT (7 versus 13 months). The median OS was 15 months (95% confidence interval [CI], 12-18 months) with a nonsignificant trend in favor of non-PVT versus PVT patients (18 versus 13 months). Five complete responses occurred (9.6%), and the 2 year-progression rate was 62%. Objective response was 40.4%, whereas the disease control rate (78.8%) significantly affected survival (responders versus nonresponders: 18.4% versus 9.1%; P = 0.009). Tumor response significantly correlated with absorbed dose in target lesions (r = 0.60, 95% CI, 0.41-0.74, P < 0.001) and a threshold of 500 Gy predicted response (area under the curve, 0.78). Mortality at 30-90 days was 0%-3.8%. Various grades of reduction in liver function occurred within 6 months in 36.5% of patients, with no differences among stages. On multivariate analysis, tumor response was the sole variable affecting TTP (P < 0.001) and the second affecting survival (after Child-Pugh class). CONCLUSION: Y90RE is an effective treatment in intermediate to advanced HCC, particularly in the case of PVT. Further prospective evaluations comparing Y90RE with conventional treatments are warranted.


Assuntos
Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Índice de Gravidade de Doença , Radioisótopos de Ítrio , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/mortalidade , Estudos de Coortes , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
9.
Eur J Nucl Med Mol Imaging ; 41(10): 1976-88, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24915892

RESUMO

Molecular radiotherapy (MRT) has demonstrated unique therapeutic advantages in the treatment of an increasing number of cancers. As with other treatment modalities, there is related toxicity to a number of organs at risk. Despite the large number of clinical trials over the past several decades, considerable uncertainties still remain regarding the optimization of this therapeutic approach and one of the vital issues to be answered is whether an absorbed radiation dose-response exists that could be used to guide personalized treatment. There are only limited and sporadic data investigating MRT dosimetry. The determination of dose-effect relationships for MRT has yet to be the explicit aim of a clinical trial. The aim of this article was to collate and discuss the available evidence for an absorbed radiation dose-effect relationships in MRT through a review of published data. Based on a PubMed search, 92 papers were found. Out of 79 studies investigating dosimetry, an absorbed dose-effect correlation was found in 48. The application of radiobiological modelling to clinical data is of increasing importance and the limited published data on absorbed dose-effect relationships based on these models are also reviewed. Based on National Cancer Institute guideline definition, the studies had a moderate or low rate of clinical relevance due to the limited number of studies investigating overall survival and absorbed dose. Nevertheless, the evidence strongly implies a correlation between the absorbed doses delivered and the response and toxicity, indicating that dosimetry-based personalized treatments would improve outcome and increase survival.


Assuntos
Medicina Baseada em Evidências/métodos , Neoplasias/diagnóstico por imagem , Radioterapia/métodos , Humanos , Neoplasias/radioterapia , Cintilografia , Dosagem Radioterapêutica
10.
Eur Radiol ; 24(1): 143-50, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23979108

RESUMO

OBJECTIVE: Evaluation of the diagnostic efficacy and interobserver agreement of Q-elastography in the differentiation of benign from malignant thyroid nodules. METHODS: A total of 344 thyroid nodules in 288 patients were examined with grey-scale and colour Doppler ultrasound (CDUS) and Q-elastography by two independent operators. Nodules with hypoechogenicity, poorly defined margins, microcalcifications, and intralesional vascularity were classified as suspicious. Diagnostic performances of CDUS features and Q-elastography for predicting thyroid malignancy were estimated using ROC analysis. Cytology or histopathology was the reference standard. Interobserver agreement in the evaluation of CDUS and Q-elastography was assessed using Cohen's k-statistic. RESULTS: Q-elastography showed excellent diagnostic performance for the prediction of thyroid malignancy, with sensitivity of 93 % and specificity of 92 % for operator 1 (best cutoff at 2.02), and sensitivity of 84 % and specificity of 79 % for operator 2 (best cutoff at 1.86). Performance of Q-elastography was superior to that of CDUS. Reproducibility of the findings was excellent for both Q-elastography and CDUS features as assessed with Cohen's k, which was highest for strain ratio measurements (0.95) and lowest for the echogenicity score (0.83). CONCLUSIONS: Q-elastography showed excellent performance. It is a valid and reproducible diagnostic method as well as a promising tool for identifying suspicious solid thyroid nodules needing cytological assessment and surgery. KEY POINTS: • Elastography is an additional tool for optimal characterisation of malignant thyroid nodules. • The use of semiquantitative elastographic evaluation increases the diagnostic performance, • The interobserver agreement of quantitative elastography can be considered to be good.


Assuntos
Calcinose/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Ultrassonografia Doppler em Cores/métodos , Adulto Jovem
12.
Health Phys ; 127(2): 276-286, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38394553

RESUMO

ABSTRACT: In the widespread use of medical cyclotrons for isotope production, radiological and economic consequences related to the decommissioning of particle accelerators are often neglected. However, decommissioning regulation and its related procedures always demand efforts and costs that can unexpectedly impact on budgets. The magnitude of this impact depends strongly on the residual radioactivity of the accelerator and of the vault, and more specifically on the kind and activity concentration of residual radionuclides. This work reports and discusses a case study that analyzes in detail the characterization activities needed for optimized management of the decommissioning of a medical cyclotron vault. In particular, this paper presents the activities carried out for assessing the activity concentrations and for guiding the disposal of the cyclotron vault of the Italian National Cancer Institute of Milano (INT). An unshielded 17 MeV cyclotron vault was characterized by high resolution gamma-ray spectrometry both in-situ and in-laboratory on extracted samples. Monte Carlo simulations were also carried out to assess the overall distribution of activation in the vault. After a few months from the final shutdown of the accelerator, activity concentrations in the concrete walls due to neutron activation exceeded the clearance levels in many regions, especially close to the cyclotron target. Due to the relatively long half-lives of some radionuclides, a time interval of about 20 y after the end of bombardment is necessary for achieving clearance in some critical positions. Far from the target or in positions shielded by the cyclotron, activation levels were below the clearance level. The comparison between Monte Carlo simulations and experimental results shows a good agreement. The in-situ measurements, simpler and economically advantageous, cannot completely replace the destructive measurements, but they may limit the number of required samples and consequently the decommissioning costs. The methodology described and the results obtained demonstrated that it is possible to obtain accurate estimations of activity concentrations with cheap and quick in-situ measurements if the concentration profile in-depth inside the wall is well known. This profile can be obtained either experimentally or numerically through suitably validated Monte Carlo simulations.


Assuntos
Ciclotrons , Método de Monte Carlo , Itália , Radioisótopos/análise , Resíduos Radioativos/análise , Humanos
13.
Phys Med ; 116: 103166, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37926641

RESUMO

The European Council Directive 2013/59/Euratom (BSS Directive) includes optimisation of treatment with radiotherapeutic procedures based on patient dosimetry and verification of the absorbed doses delivered. The present policy statement summarises aspects of three directives relating to the therapeutic use of radiopharmaceuticals and medical devices, and outlines the steps needed for implementation of patient dosimetry for radioactive drugs. To support the transition from administrations of fixed activities to personalised treatments based on patient-specific dosimetry, EFOMP presents a number of recommendations including: increased networking between centres and disciplines to support data collection and development of codes-of-practice; resourcing to support an infrastructure that permits routine patient dosimetry; research funding to support investigation into individualised treatments; inter-disciplinary training and education programmes; and support for investigator led clinical trials. Close collaborations between the medical physicist and responsible practitioner are encouraged to develop a similar pathway as is routine for external beam radiotherapy and brachytherapy. EFOMP's policy is to promote the roles and responsibilities of medical physics throughout Europe in the development of molecular radiotherapy to ensure patient benefit. As the BSS directive is adopted throughout Europe, unprecedented opportunities arise to develop informed treatments that will mitigate the risks of under- or over-treatments.


Assuntos
Medicina Nuclear , Humanos , Radiometria , Políticas , Europa (Continente)
15.
Tumori ; 108(4): 315-325, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34405748

RESUMO

OBJECTIVE: To give an updated overview on clinical aspects and survival effects of lutetium-177-prostate-specific membrane antigen (PSMA) (177Lu-PSMA) radioligand therapy (RLT), a novel treatment option for patients with metastatic castration-resistant prostate cancer (mCRPC). METHODS: PubMed/MEDLINE database was searched for relevant articles published up to March 2021. The search was restricted to English-language articles. RESULTS: Current evidence from the literature consistently demonstrated the efficacy, safety, and survival benefit of 177Lu-PSMA RLT in mCRPC. However, current data rely predominantly on retrospective analyses, showing heterogeneity of patient population and treatment protocols. More recently, results from the first randomized phase II study (TheraP) demonstrated that 177Lu-PMSA therapy significantly improved prostate-specific antigen response rate (66% vs 37%) and had fewer grade 3/4 adverse events when compared to cabazitaxel in patients with docetaxel-pretreated, progressive mCRPC. This review is intended to provide an updated overview of treatment protocols and responses, toxicity profile, and survival effects of 177Lu-PSMA RLT. CONCLUSIONS: 177Lu-PSMA RLT has emerged as a promising targeted treatment in mCRPC. It is currently applied in compassionate use programs and following exhaustion of approved therapies. Crucial for establishing this treatment in routine clinical management will be the results of the phase III VISION trial, which may confirm the encouraging patient outcomes reported to date.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Ensaios Clínicos Fase II como Assunto , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Neoplasias de Próstata Resistentes à Castração/radioterapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Resultado do Tratamento
16.
Cancers (Basel) ; 14(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35205712

RESUMO

In this confirmatory study, we tested if a calculation that included the non-uniformity of dose deposition through a voxel-based dosimetric variable Ψ was able to improve the dose-response agreement with respect to the mean absorbed dose D. We performed dosimetry with 99mTc-MAA SPECT/CT and 90Y-PET/CT in 86 patients treated 8 instead of 4 days after the reference date with 2.8 times more 90Y glass microspheres/GBq than in our previous study. The lesion-by-lesion response was assessed with the mRECIST method and with an experimental densitometric criterion. A total of 106 lesions were studied. Considering Ψ as a prognostic response marker, having no Ψ provided a significantly higher AUC than D. The correlation, t-test, and AUC values were statistically significant only with the densitometric method and only with post-therapy dosimetry. In comparison with our previous study, the dose-response correlation and AUC values were poorer (maximum r = 0.43, R2 = 0.14, maximal AUC = 0.71), and the efficacy at a high dose did not reach 100%. The expected advantages of voxel dosimetry were nullified by the correlation between any Ψ and D due to the limited image spatial resolution. The lower AUC and efficacy may be explained by the mega-clustering effect triggered by the higher number of microspheres/GBq injected on day 8.

17.
Eur J Nucl Med Mol Imaging ; 38(7): 1393-406, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21494856

RESUMO

Primary liver cancers (i.e. hepatocellular carcinoma or cholangiocarcinoma) are worldwide some of the most frequent cancers, with rapidly fatal liver failure in a large majority of patients. Curative therapy consists of surgery (i.e. resection or liver transplantation), but only 10-20% of patients are candidates for this. In other patients, a variety of palliative treatments can be given, such as chemoembolization, radiofrequency ablation or recently introduced tyrosine kinase inhibitors, e.g. sorafenib. Colorectal cancer is the second most lethal cancer in Europe and liver metastases are prevalent either at diagnosis or in follow-up. These patients are usually treated by a sequence of surgery, chemotherapy and antibody therapy [Okuda et al. (Cancer 56:918-928, 1985); Schafer and Sorrell (Lancet 353:1253-1257, 1999); Leong et al. (Arnold, London, 1999)]. Radioembolization is an innovative therapeutic approach defined as the injection of micron-sized embolic particles loaded with a radioisotope by use of percutaneous intra-arterial techniques. Advantages of the use of these intra-arterial radioactive compounds are the ability to deliver high doses of radiation to small target volumes, the relatively low toxicity profile, the possibility to treat the whole liver including microscopic disease and the feasibility of combination with other therapy modalities. Disadvantages are mainly due to radioprotection constraints mainly for (131)I-labelled agents, logistics and the possibility of inadvertent delivery or shunting [Novell et al. (Br J Surg 78:901-906, 1991)]. The Therapy, Oncology and Dosimetry Committees have worked together in order to revise the European Association of Nuclear Medicine (EANM) guidelines on the use of the radiopharmaceutical (131)I-Lipiodol (Lipiocis®, IBA, Brussels, Belgium) and include the newer medical devices with (90)Y-microspheres. (90)Y is either bound to resin (SIR-Spheres®, Sirtex Medical, Lane Cove, Australia) or embedded in a glass matrix (TheraSphere®, MDS Nordion, Kanata, ON, Canada). Since (90)Y-microspheres are not metabolized, they are not registered as unsealed sources. However, the microspheres are delivered in aqueous solution: radioactive contamination is a concern and microspheres should be handled, like other radiopharmaceuticals, as open sources. The purpose of this guideline is to assist the nuclear medicine physician in treating and managing patients undergoing such treatment.


Assuntos
Artérias , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Medicina Nuclear/métodos , Traçadores Radioativos , Radioterapia/métodos , Sociedades Médicas , Contraindicações , Europa (Continente) , Seguimentos , Neoplasias Hepáticas/irrigação sanguínea , Microesferas , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/uso terapêutico , Radioterapia/efeitos adversos , Radioterapia/normas , Planejamento da Radioterapia Assistida por Computador , Valores de Referência
18.
Phys Med ; 89: 317-326, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34583307

RESUMO

This recommendation by the Italian Associations of Nuclear Medicine (AIMN) and Medical Physics (AIFM) focuses on the dosimetric optimization of Nuclear Medicine Therapy (NMT) as clearly requested by the article 56 of the EURATOM Directive 2013/59 and its consequent implementation in article 158 in the Italian Law n. 101/2020. However, this statement must deal with scientific and methodological limits that still exist and, above all, with the currently available limited resources. This paper addresses these specific issues. It distinguishes among many possible kinds of NMT. For each type, dosimetric optimization is recommended or considered optional, according to the general criteria adopted in any human choice, i.e. a check of technical feasibility first, followed by a cost/benefit argument. The classification of therapies as standardized or non-standardized is presented. This is based on the complexity of the type of pathology, on the variability of the treatment outcome, and on the risks involved. According to the present document, which was officially delivered to Italian Health Ministry as necessary interpretation of the law, a therapeutic team can, in science and consciousness, overcome the indications of posology, to optimize and tailoring a treatment with dosimetry, on the basis of published national or international data or guidelines, without need of an Ethics Committee approval. Data collected in this way will provide additional evidence about optimal dosimetric reference values. As conclusion, a formal appeal is made to the European and National regulatory agencies for pharmaceuticals to obtain the official acknowledgment of this principle.


Assuntos
Medicina Nuclear , União Europeia , Humanos , Itália , Física , Radiometria
19.
EJNMMI Phys ; 8(1): 77, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34767102

RESUMO

The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in 90Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of 99mTc albumin macro-aggregates (MAA) and 90Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between 99mTc-MAA predictions and actual 90Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments.Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected 99mTc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and 90Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected 99mTc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative 90Y bremsstrahlung SPECT can be used if dedicated correction methods are available.The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.

20.
Eur J Nucl Med Mol Imaging ; 37(6): 1238-50, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20411259

RESUMO

INTRODUCTION: The level of administered activity in radionuclide therapy is often limited by haematological toxicity resulting from the absorbed dose delivered to the bone marrow. The purpose of these EANM guidelines is to provide advice to scientists and clinicians on data acquisition and data analysis related to bone-marrow and whole-body dosimetry. MATERIALS AND METHODS: The guidelines are divided into sections "Data acquisition" and "Data analysis". The Data acquisition section provides advice on the measurements required for accurate dosimetry including blood samples, quantitative imaging and/or whole-body measurements with a single probe. Issues specific to given radiopharmaceuticals are considered. The Data analysis section provides advice on the calculation of absorbed doses to the whole body and the bone marrow. The total absorbed dose to the bone marrow consists of contributions from activity in the bone marrow itself (self-absorbed dose) and the cross-absorbed dose to the bone marrow from activity in bone, larger organs and the remainder of the body. CONCLUSION: As radionuclide therapy enters an era where patient-specific dosimetry is used to guide treatments, accurate bone-marrow and whole-body dosimetry will become an essential element of treatment planning. We hope that these guidelines will provide a basis for the optimization and standardization of the treatment of cancer with radiopharmaceuticals, which will facilitate single- and multi-centre radionuclide therapy studies.


Assuntos
Medula Óssea/efeitos da radiação , Medicina Nuclear/métodos , Radiometria/métodos , Sociedades Médicas , Imagem Corporal Total/métodos , Células Sanguíneas/efeitos da radiação , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Europa (Continente) , Espaço Extracelular/efeitos da radiação , Processamento de Imagem Assistida por Computador , Doses de Radiação , Radiografia , Cintilografia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA