Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Endocrinol Invest ; 44(5): 1097-1101, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32852704

RESUMO

OBJECTIVE: To assess the magnitude of COVID-19 spread and the associated risk factors among health care workers (HCWs), we conducted an in-hospital survey in a central Italian COVID Hospital. METHODS: Participants underwent nasopharyngeal swab and/or serum collection for SARS-CoV-2 IgG examination. We divided participants according to working status, into rotating-night shift workers (r-NSW) and day-workers. RESULTS: We found 30 cases of COVID-19 infection in a total of 1180 HCWs (2.5%). Most COVID-19-positive hospital employees were r-NSWs with significantly higher BMI than that of individuals who tested negative. After adjustment for covariates, night work and BMI > 30 were associated with a markedly greater risk of COVID-19 diagnosis (OR 3.049 [95%CI 1.260-7.380] and OR 7.15 [95%CI 2.91-17.51], respectively). CONCLUSIONS: Our results describe a low prevalence of COVID-19 infection among HCWs at a central Italian COVID Hospital. COVID-19 infection risk appears to be associated with obesity and night shift work, thus supporting the need for careful health surveillance among frontline HCWs exposed to COVID-19.


Assuntos
Índice de Massa Corporal , COVID-19/epidemiologia , Pessoal de Saúde/estatística & dados numéricos , Jornada de Trabalho em Turnos , Idoso , Teste para COVID-19 , Feminino , Humanos , Imunoglobulina G/imunologia , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/epidemiologia , Recursos Humanos em Hospital , Prevalência , Fatores de Risco , Inquéritos e Questionários
2.
Breast ; 76: 103755, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38852211

RESUMO

INTRODUCTION: Neoadjuvant chemotherapies for breast cancer (BC) are effective but potentially cardiotoxic, and expose long survivors at risk of chemotherapy-related cardiac dysfunction (CTRCD). Unfortunately, early screening for CTRCD has actual diagnostic limits. Myocardial extracellular volume (mECV) is a radiological marker used in cardiac CT scans and cardiac magnetic resonance for diagnosis and follow-up of CTRCD. It can be measured in whole-body CT (WB-CT) scan, routinely performed in patients at high risk of relapse, to evaluate CTRCD occurrence during oncological follow-up. METHODS: 82 WB-CT scans were examined at baseline (T0) and during oncological follow-up at first year (T1) and fifth year (T5) after the end of neoadjuvant treatment. mECV was measured at 1 min (PP) and 5 min (DP) after contrast injection. 31 echocardiograms were retrieved in T1 to perform a linear correlation between mECV and left ventricular ejection fraction (LVEF). RESULTS: mECV values in T0 were similar between the two groups both in PP and in DP. Significant results were found for PP values in T1 (37.0 % vs 32 %, p = 0.0005) and in T5 (27.2 % vs 31.2 %, p = 0.025). A cut-off value of 35 % in PP proved significant in T1 (OR = 12.4, p = 0.004), while mECV was inversely correlated with LVEF both in PP (adj-S = -3.54, adj-p = 0.002) and in DP (adj-S = -2.51, adj-p = 0.0002), suggesting a synergistic action with the age at diagnosis (p < 0.0001, respectively). CONCLUSIONS: WB-CT scans performed during oncological reassessment in patients at high-risk of recurrence could be used for CTRCD screening in cardiovascular low-risk patients, especially in aging patients with mECV values above 35 %.

3.
Neuroradiology ; 55(2): 193-200, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23014893

RESUMO

INTRODUCTION: This study aims to assess the effectiveness of combined procedure of cryoablation and vertebroplasty (CVT) for reduction of pain and improvement of the quality of life in patients with single painful metastatic vertebral fractures. METHODS: We retrospectively analyzed data from 23 patients with single vertebral metastasis treated with combined procedure of CVT, compared with those obtained in 23 patients treated by vertebroplasty. Pain intensity was evaluated by a visual analog scale (VAS) score administered before and 1 day, 1 week, and 1, 3, and 6 months after procedure. Quality of life was evaluated by an Oswestry Disability Index (ODI) score administered before and at 3 and 6 months after procedure. RESULTS: Procedural success was achieved in all patients without any complications. The VAS and ODI scores showed a reduction in both groups during follow-up (VAS score, p < 0.05 and p < 0.001, respectively; ODI score, p < 0.0001). No difference of the VAS and ODI scores were observed before treatment (p = 0.33 and 0.78, respectively). VAS score showed a difference at 1 week and 1, 3, and 6 months after treatment (p < 0.001). ODI score showed a difference at 3 and 6 months after treatment (p < 0.001). CONCLUSION: Our findings suggested that combined procedure of CVT is safe and effective for pain relief in single metastatic vertebral fractures, especially when other standard palliative treatments have failed, and improves disability. Careful needle positioning and accurate fluoroscopic and CT guidance are mandatory for a complication-free treatment.


Assuntos
Angiografia/métodos , Criocirurgia/métodos , Fraturas da Coluna Vertebral/terapia , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/terapia , Vertebroplastia/métodos , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada/métodos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Rotação , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Resultado do Tratamento
4.
Eur Rev Med Pharmacol Sci ; 26(10): 3712-3717, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35647853

RESUMO

OBJECTIVE: Spontaneous coronary artery dissection (SCAD) is a spontaneous separation of the coronary artery wall whose etiology appears to be poorly understood. SCAD is a rare cause of acute coronary syndromes, and it is a life-threatening condition. CASE REPORT: We report the case of a young woman who developed SCAD during a thyroid storm (TS). RESULTS: To the best of our knowledge, this is the first reported case of SCAD during a TS, and it suggests a possible association between high levels of circulating thyroid hormones and SCAD susceptibility. CONCLUSIONS: Early identification of SCAD predisposing factors is important to identify high-risk patients. In patients presenting to the emergency department because of chest pain with a history of dysthyroidism, early determination of thyroid hormones and troponin could prevent certain forms of sudden cardiac death.


Assuntos
Dissecção Aórtica , Aneurisma Coronário , Crise Tireóidea , Dissecção Aórtica/etiologia , Aneurisma Coronário/complicações , Anomalias dos Vasos Coronários , Vasos Coronários , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Crise Tireóidea/complicações , Crise Tireóidea/diagnóstico , Doenças Vasculares/congênito
5.
Ann Cardiol Angeiol (Paris) ; 70(3): 161-167, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33958189

RESUMO

PURPOSE: Spontaneous coronary artery dissection (SCAD) may occur in middle age population without any cardiovascular risk factor. We retrospectively evaluated anatomic features of 11 patients with SCAD using a coronary arteries computed tomography (CCT), compared to age and sex balanced patients who underwent CCT. MATERIAL AND METHODS: CCT was performed in 11 patients (7 females and 4 males) as follow-up in patients with SCAD (left anterior descending - LAD or circumflex artery - Cx) and compared, using the propensity score matching analysis, with 11 healthy patients. Several anatomic features were evaluated: Left main (LM) length, angle between descending coronary artery (LAD) and its first branch, angle between LAD and LM, distance from the annulus to RCA (a-RCA distance) and LM (a-LM distance) ostia and their ratio; ratio between LM length and length a-LM and tortuosity score of the vessel with SCAD. A fluid dynamic analysis has been performed to evaluate the effects on shear stress of vessels wall. RESULTS: LM length was significantly shorter in patients with SCAD versus healthy subjects (P=0.01) as well as LM length/a-LM (P=0.03) and the angle between LAD and the first adjacent branch was sharper (P<0.01). Tortuosity score showed a statistically significant difference between groups (P<0.001). Fluid dynamic analysis demonstrates that, in SCAD group, an angle<90 degree is present at the first bifurcation and it can be a cause of increased strain on vessel wall in patients with high tortuosity of coronary artery. CONCLUSION: Tortuosity and angle between the LAD and the adjacent arterial branch combined may determine increased shear stress on the vessel wall that increases the risk of SCAD.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Pontuação de Propensão , Doenças Vasculares/congênito , Fatores Etários , Estudos de Casos e Controles , Anomalias dos Vasos Coronários/etiologia , Anomalias dos Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Feminino , Hemorreologia/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia
6.
Eur Rev Med Pharmacol Sci ; 23(18): 8018-8027, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31599427

RESUMO

OBJECTIVE: The aim of the meta-analysis was to assess post-procedural outcome of the new generation of transcatheter aortic valve implantation (TAVI) devices, focusing on the transfemoral and balloon-expandable SAPIEN 3 (Edwards Lifesciences Inc., Irvine, CA, USA), the self-expanding CoreValveTM Evolut series R and PRO (R/PRO)TM (Medtronic Inc., Minneapolis, MN, USA) and ACURATE neoTM transcatheter aortic valve (Symetis SA, a Boston Scientific company, Ecublens, Switzerland). MATERIALS AND METHODS: All observational studies were retrieved through PubMed computerized database from January 2014 until June 30th, 2019. The risk difference (RD) with the 95% confidence interval (CI) was used to assess the effectiveness of the intervention under comparison. The primary end point was 30-day mortality. Safety end points included: (i) stroke, (ii) moderate/severe paravalvular leak, and (iii) the need for new permanent pacemaker implantation. RESULTS: Meta-analysis demonstrated no significant differences as regards to either 30-day mortality or stroke for all the groups of prostheses under comparison. ACURATE neo was associated with significantly less new permanent pacemaker implantation compared to SAPIEN 3 (RD: -0.06; 95% CI -0.08 to -0.03; p<0.0001; I2=0%) or to EVOLUT R/PRO (RD: -0.06; 95% CI -0.09 to -0.02; p=0.0009; I2=0%). A significant reduction of new permanent pacemaker need was observed in the group of patients implanted with SAPIEN 3 compared to EVOLUT R/PRO (RD: -0.07; 95% CI -0.09 to -0.04; p<0.00001; I2=7%). The occurrence of moderate/severe leak was significantly increased in the group of patients implanted with ACURATE neo vs. SAPIEN 3 (RD: 0.04; 95% CI 0.02 to 0.05; p<0.00001; I2=0%). No significant differences were found between ACURATE neo vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.02; p=0.69; I2=0%) and between SAPIEN 3 vs. EVOLUT R/PRO (RD: -0.01; 95% CI -0.04 to 0.01; p=0.28; I2=73%). CONCLUSIONS: The results of the meta-analysis show that: (1) ACURATE neo was associated with significantly less new permanent pacemaker implantation than SAPIEN 3 and EVOLUT R/PRO; (2) SAPIEN 3 had significantly lower occurrence of moderate/severe valvular leak than ACURATE neo.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Estimulação Cardíaca Artificial , Humanos , Mortalidade , Falha de Prótese , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
7.
Eur Rev Med Pharmacol Sci ; 23(12): 5402-5412, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31298393

RESUMO

OBJECTIVE: We studied the impact of transcatheter aortic valve implantation (TAVI) compared to the surgical aortic valve replacement (SAVR) on 30-day and one-year mortality from randomized controlled trials (RCTs) in patients with severe aortic stenosis at high or low-intermediate surgical risk. MATERIALS AND METHODS: All RCTs were retrieved through PubMed computerized database and the site https://www.clinicaltrials.gov from January 2010 until March 31st, 2019. The absolute risk reduction (RD) with the 95% confidence interval (CI) was used to assess the effectiveness of the intervention under comparison. We evaluated overall mortality rates at 30-day and one-year follow-up in the comparison between TAVI vs. SAVR. We also evaluated the role played by the site access for TAVI performed through the femoral or subclavian artery (TV-TAVI) vs. SAVR, or transapically (TA-TAVI) vs. SAVR. RESULTS: In the "as-treated population" the overall 30-day mortality was significantly lower in TAVI (p=0.03) with respect to SAVR. However, the analysis for TAVI subgroups showed that 30-day mortality was (1) significantly lower in TV-TAVI vs. SAVR (p=0.006), (2) increased, not significantly, in TA-TAVI vs. SAVR (p=0.62). No significant differences were found between TAVI vs. SAVR at one-year follow-up. CONCLUSIONS: The results of our meta-analysis suggest that TV-TAVI is a powerful tool in the treatment of severe aortic stenosis at high or low-intermediate surgical risk, with a significant lower mortality with respect to SAVR. On the contrary, SAVR seems to provide better results than TA-TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Mortalidade Hospitalar , Humanos , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
8.
Cardiovasc Intervent Radiol ; 31(5): 1030-3, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17968618

RESUMO

A young patient affected by a pelvic arteriovenous malformation (pAVM) with recurrent episodes of hematuria following exercise, underwent transcatheter embolization using Glubran 2 acrylic glue (GEM, Viareggio, Italy). All branches of the pAVM were successfully occluded. The patient showed prompt resolution of symptoms and persistent occlusion of the pAVM at the 6 month follow-up.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Embolização Terapêutica/métodos , Pelve/diagnóstico por imagem , Adulto , Angiografia Digital/métodos , Malformações Arteriovenosas/fisiopatologia , Cateterismo , Cianoacrilatos/farmacologia , Cistoscopia/métodos , Seguimentos , Hematúria/diagnóstico , Hematúria/etiologia , Humanos , Masculino , Pelve/fisiopatologia , Radiografia Intervencionista/métodos , Medição de Risco , Adesivos Teciduais/farmacologia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Urinálise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA