Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 302(1): 218-225, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34665030

RESUMO

Background Aortic diameter measurements in patients with a thoracic aortic aneurysm (TAA) show wide variation. There is no technique to quantify aortic growth in a three-dimensional (3D) manner. Purpose To validate a CT-based technique for quantification of 3D growth based on deformable registration in patients with TAA. Materials and Methods Patients with ascending and descending TAA with two or more CT angiography studies between 2006 and 2020 were retrospectively identified. The 3D aortic growth was quantified using vascular deformation mapping (VDM), a technique that uses deformable registration to warp a mesh constructed from baseline aortic anatomy. Growth assessments between VDM and clinical CT diameter measurements were compared. Aortic growth was quantified as the ratio of change in surface area at each mesh element (area ratio). Manual segmentations were performed by independent raters to assess interrater reproducibility. Registration error was assessed using manually placed landmarks. Agreement between VDM and clinical diameter measurements was assessed using Pearson correlation and Cohen κ coefficients. Results A total of 38 patients (68 surveillance intervals) were evaluated (mean age, 69 years ± 9 [standard deviation]; 21 women), with TAA involving the ascending aorta (n = 26), descending aorta (n = 10), or both (n = 2). VDM was technically successful in 35 of 38 (92%) patients and 58 of 68 intervals (85%). Median registration error was 0.77 mm (interquartile range, 0.54-1.10 mm). Interrater agreement was high for aortic segmentation (Dice similarity coefficient = 0.97 ± 0.02) and VDM-derived area ratio (bias = 0.0, limits of agreement: -0.03 to 0.03). There was strong agreement (r = 0.85, P < .001) between peak area ratio values and diameter change. VDM detected growth in 14 of 58 (24%) intervals. VDM revealed growth outside the maximally dilated segment in six of 14 (36%) growth intervals, none of which were detected with diameter measurements. Conclusion Vascular deformation mapping provided reliable and comprehensive quantitative assessment of three-dimensional aortic growth and growth patterns in patients with thoracic aortic aneurysms undergoing CT surveillance. Published under a CC BY 4.0 license Online supplemental material is available for this article. See also the editorial by Wieben in this issue.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/patologia , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional/métodos , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Bipolar Disord ; 20(4): 381-390, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29316081

RESUMO

OBJECTIVES: Quantitative mapping of T1 relaxation in the rotating frame (T1ρ) is a magnetic resonance imaging technique sensitive to pH and other cellular and microstructural factors, and is a potentially valuable tool for identifying brain alterations in bipolar disorder. Recently, this technique identified differences in the cerebellum and cerebral white matter of euthymic patients vs healthy controls that were consistent with reduced pH in these regions, suggesting an underlying metabolic abnormality. The current study built upon this prior work to investigate brain T1ρ differences across euthymic, depressed, and manic mood states of bipolar disorder. METHODS: Forty participants with bipolar I disorder and 29 healthy control participants matched for age and gender were enrolled. Participants with bipolar disorder were imaged in one or more mood states, yielding 27, 12, and 13 imaging sessions in euthymic, depressed, and manic mood states, respectively. Three-dimensional, whole-brain anatomical images and T1ρ maps were acquired for all participants, enabling voxel-wise evaluation of T1ρ differences between bipolar mood state and healthy control groups. RESULTS: All three mood state groups had increased T1ρ relaxation times in the cerebellum compared to the healthy control group. Additionally, the depressed and manic groups had reduced T1ρ relaxation times in and around the basal ganglia compared to the control and euthymic groups. CONCLUSIONS: The study implicated the cerebellum and basal ganglia in the pathophysiology of bipolar disorder and its mood states, the roles of which are relatively unexplored. These findings motivate further investigation of the underlying cause of the abnormalities, and the potential role of altered metabolic activity in these regions.


Assuntos
Afeto/fisiologia , Gânglios da Base , Transtorno Bipolar , Cerebelo , Adulto , Gânglios da Base/diagnóstico por imagem , Gânglios da Base/metabolismo , Transtorno Bipolar/diagnóstico , Transtorno Bipolar/metabolismo , Mapeamento Encefálico/métodos , Cerebelo/diagnóstico por imagem , Cerebelo/metabolismo , Correlação de Dados , Feminino , Humanos , Concentração de Íons de Hidrogênio , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa
3.
J Appl Clin Med Phys ; 17(2): 550-560, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074479

RESUMO

Ventilation distribution calculation using 4D CT has shown promising potential in several clinical applications. This study evaluated the direct geometric ventilation calculation method, namely the ΔV method, with xenon-enhanced CT (XeCT) ventilation data from four sheep, and compared it with two other published meth-ods, the Jacobian and the Hounsfield unit (HU) methods. Spearman correlation coefficient (SCC) and Dice similarity coefficient (DSC) were used for the evaluation and comparison. The average SCC with one standard deviation was 0.44 ± 0.13 with a range between 0.29 and 0.61 between the XeCT and ΔV ventilation distributions. The average DSC value for lower 30% ventilation volumes between the XeCT and ΔV ventilation distributions was 0.55 ± 0.07 with a range between 0.48 and 0.63. Ventilation difference introduced by deformable image registration errors improved with smoothing. In conclusion, ventilation distributions generated using ΔV-4D CT and deformable image registration are in reasonably agreement with the in vivo XeCT measured ventilation distribution.


Assuntos
Algoritmos , Tomografia Computadorizada Quadridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Ventilação Pulmonar , Respiração , Xenônio , Animais , Masculino , Ovinos , Razão Sinal-Ruído
4.
IEEE Trans Med Imaging ; 43(7): 2448-2465, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38373126

RESUMO

Chest computed tomography (CT) at inspiration is often complemented by an expiratory CT to identify peripheral airways disease. Additionally, co-registered inspiratory-expiratory volumes can be used to derive various markers of lung function. Expiratory CT scans, however, may not be acquired due to dose or scan time considerations or may be inadequate due to motion or insufficient exhale; leading to a missed opportunity to evaluate underlying small airways disease. Here, we propose LungViT- a generative adversarial learning approach using hierarchical vision transformers for translating inspiratory CT intensities to corresponding expiratory CT intensities. LungViT addresses several limitations of the traditional generative models including slicewise discontinuities, limited size of generated volumes, and their inability to model texture transfer at volumetric level. We propose a shifted-window hierarchical vision transformer architecture with squeeze-and-excitation decoder blocks for modeling dependencies between features. We also propose a multiview texture similarity distance metric for texture and style transfer in 3D. To incorporate global information into the training process and refine the output of our model, we use ensemble cascading. LungViT is able to generate large 3D volumes of size 320×320×320 . We train and validate our model using a diverse cohort of 1500 subjects with varying disease severity. To assess model generalizability beyond the development set biases, we evaluate our model on an out-of-distribution external validation set of 200 subjects. Clinical validation on internal and external testing sets shows that synthetic volumes could be reliably adopted for deriving clinical endpoints of chronic obstructive pulmonary disease.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Algoritmos , Radiografia Torácica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
5.
Int J Radiat Oncol Biol Phys ; 119(5): 1393-1402, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38387810

RESUMO

PURPOSE: To determine whether 4-dimensional computed tomography (4DCT) ventilation-based functional lung avoidance radiation therapy preserves pulmonary function compared with standard radiation therapy for non-small cell lung cancer (NSCLC). METHODS AND MATERIALS: This single center, randomized, phase 2 trial enrolled patients with NSCLC receiving curative intent radiation therapy with either stereotactic body radiation therapy or conventionally fractionated radiation therapy between 2016 and 2022. Patients were randomized 1:1 to standard of care radiation therapy or functional lung avoidance radiation therapy. The primary endpoint was the change in Jacobian-based ventilation as measured on 4DCT from baseline to 3 months postradiation. Secondary endpoints included changes in volume of high- and low-ventilating lung, pulmonary toxicity, and changes in pulmonary function tests (PFTs). RESULTS: A total of 122 patients were randomized and 116 were available for analysis. Median follow up was 29.9 months. Functional avoidance plans significantly (P < .05) reduced dose to high-functioning lung without compromising target coverage or organs at risk constraints. When analyzing all patients, there was no difference in the amount of lung showing a reduction in ventilation from baseline to 3 months between the 2 arms (1.91% vs 1.87%; P = .90). Overall grade ≥2 and grade ≥3 pulmonary toxicities for all patients were 24.1% and 8.6%, respectively. There was no significant difference in pulmonary toxicity or changes in PFTs between the 2 study arms. In the conventionally fractionated cohort, there was a lower rate of grade ≥2 pneumonitis (8.2% vs 32.3%; P = .049) and less of a decline in change in forced expiratory volume in 1 second (-3 vs -5; P = .042) and forced vital capacity (1.5 vs -6; P = .005) at 3 months, favoring the functional avoidance arm. CONCLUSIONS: There was no difference in posttreatment ventilation as measured by 4DCT between the arms. In the cohort of patients treated with conventionally fractionated radiation therapy with functional lung avoidance, there was reduced pulmonary toxicity, and less decline in PFTs suggesting a clinical benefit in patients with locally advanced NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Pulmão , Humanos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Pulmão/efeitos da radiação , Pulmão/diagnóstico por imagem , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/efeitos da radiação , Órgãos em Risco/diagnóstico por imagem , Testes de Função Respiratória , Respiração
6.
J Affect Disord ; 368: 448-460, 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39278469

RESUMO

BACKGROUND: Bipolar disorder (BD) is a chronic psychiatric mood disorder that is solely diagnosed based on clinical symptoms. These symptoms often overlap with other psychiatric disorders. Efforts to use machine learning (ML) to create predictive models for BD based on data from brain imaging are expanding but have often been limited using only a single modality and the exclusion of the cerebellum, which may be relevant in BD. METHODS: In this study, we sought to improve ML classification of BD by combining information from structural, functional, and diffusion-weighted imaging. Participants (108 BD I, 78 control) with BD type I and matched controls were recruited into an imaging study. This dataset was randomly divided into training and testing sets. For each of the three modalities, a separate ML model was selected, trained, and then used to generate a prediction of the class of each test subject. Majority voting was used to combine results from the three models to make a final prediction of whether a subject had BD. An independent replication sample was used to evaluate the ability of the ML classification to generalize to data collected at other sites. RESULTS: Combining the three machine learning models through majority voting resulted in an accuracy of 89.5 % for classification of the test subjects as being in the BD or control group. Bootstrapping resulted in a 95 % confidence interval of 78.9 %-97.4 % for test accuracy. Performance was reduced when only using 2 of the 3 modalities. Analysis of feature importance revealed that the cerebellum and nodes of the emotional control network were among the most important regions for classification. The machine learning model performed at chance on the independent replication sample. CONCLUSION: BD I could be identified with high accuracy in our relatively small sample by combining structural, functional, and diffusion-weighted imaging data within a single site but not generalize well to an independent replication sample. Future studies using harmonized imaging protocols may facilitate generalization of ML models.

7.
Front Physiol ; 14: 1040028, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36866176

RESUMO

Purpose: To quantify the impact of image noise on CT-based lung ventilation biomarkers calculated using Jacobian determinant techniques. Methods: Five mechanically ventilated swine were imaged on a multi-row CT scanner with acquisition parameters of 120 kVp and 0.6 mm slice thickness in static and 4-dimensional CT (4DCT) modes with respective pitches of 1 and 0.09. A range of tube current time product (mAs) values were used to vary image dose. On two dates, subjects received two 4DCTs: one with 10 mAs/rotation (low-dose, high-noise) and one with CT simulation standard of care 100 mAs/rotation (high-dose, low-noise). Additionally, 10 intermediate noise level breath-hold (BHCT) scans were acquired with inspiratory and expiratory lung volumes. Images were reconstructed with and without iterative reconstruction (IR) using 1 mm slice thickness. The Jacobian determinant of an estimated transformation from a B-spline deformable image registration was used to create CT-ventilation biomarkers estimating lung tissue expansion. 24 CT-ventilation maps were generated per subject per scan date: four 4DCT ventilation maps (two noise levels each with and without IR) and 20 BHCT ventilation maps (10 noise levels each with and without IR). Biomarkers derived from reduced dose scans were registered to the reference full dose scan for comparison. Evaluation metrics were gamma pass rate (Γ) with 2 mm distance-to-agreement and 6% intensity criterion, voxel-wise Spearman correlation (ρ) and Jacobian ratio coefficient of variation (CoV JR ). Results: Comparing biomarkers derived from low (CTDI vol = 6.07 mGy) and high (CTDI vol = 60.7 mGy) dose 4DCT scans, mean Γ, ρ and CoV JR values were 93% ± 3%, 0.88 ± 0.03 and 0.04 ± 0.009, respectively. With IR applied, those values were 93% ± 4%, 0.90 ± 0.04 and 0.03 ± 0.003. Similarly, comparisons between BHCT-based biomarkers with variable dose (CTDI vol = 1.35-7.95 mGy) had mean Γ, ρ and CoV JR of 93% ± 4%, 0.97 ± 0.02 and 0.03 ± 0.006 without IR and 93% ± 4%, 0.97 ± 0.03 and 0.03 ± 0.007 with IR. Applying IR did not significantly change any metrics (p > 0.05). Discussion: This work demonstrated that CT-ventilation, calculated using the Jacobian determinant of an estimated transformation from a B-spline deformable image registration, is invariant to Hounsfield Unit (HU) variation caused by image noise. This advantageous finding may be leveraged clinically with potential applications including dose reduction and/or acquiring repeated low-dose acquisitions for improved ventilation characterization.

8.
Med Phys ; 50(5): 3199-3209, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36779695

RESUMO

BACKGROUND: Functional lung avoidance radiation therapy (RT) is a technique being investigated to preferentially avoid specific regions of the lung that are predicted to be more susceptible to radiation-induced damage. Reducing the dose delivered to high functioning regions may reduce the occurrence radiation-induced lung injuries (RILIs) and toxicities. However, in order to develop effective lung function-sparing plans, accurate predictions of post-RT ventilation change are needed to determine which regions of the lung should be spared. PURPOSE: To predict pulmonary ventilation change following RT for nonsmall cell lung cancer using machine learning. METHODS: A conditional generative adversarial network (cGAN) was developed with data from 82 human subjects enrolled in a randomized clinical trial approved by the institution's IRB to predict post-RT pulmonary ventilation change. The inputs to the network were the pre-RT pulmonary ventilation map and radiation dose distribution. The loss function was a combination of the binary cross-entropy loss and an asymmetrical structural similarity index measure (aSSIM) function designed to increase penalization of under-prediction of ventilation damage. Network performance was evaluated against a previously developed polynomial regression model using a paired sample t-test for comparison. Evaluation was performed using eight-fold cross-validation. RESULTS: From the eight-fold cross-validation, we found that relative to the polynomial model, the cGAN model significantly improved predicting regions of ventilation damage following radiotherapy based on true positive rate (TPR), 0.14±0.15 to 0.72±0.21, and Dice similarity coefficient (DSC), 0.19±0.16 to 0.46±0.14, but significantly declined in true negative rate, 0.97±0.05 to 0.62±0.21, and accuracy, 0.79±0.08 to 0.65±0.14. Additionally, the average true positive volume increased from 104±119 cc in the POLY model to 565±332 cc in the cGAN model, and the average false negative volume decreased from 654±361 cc in the POLY model to 193±163 cc in the cGAN model. CONCLUSIONS: The proposed cGAN model demonstrated significant improvement in TPR and DSC. The higher sensitivity of the cGAN model can improve the clinical utility of functional lung avoidance RT by identifying larger volumes of functional lung that can be spared and thus decrease the probability of the patient developing RILIs.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Ventilação Pulmonar , Pulmão , Respiração
9.
Med Phys ; 50(9): 5698-5714, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36929883

RESUMO

BACKGROUND: Chest computed tomography (CT) enables characterization of pulmonary diseases by producing high-resolution and high-contrast images of the intricate lung structures. Deformable image registration is used to align chest CT scans at different lung volumes, yielding estimates of local tissue expansion and contraction. PURPOSE: We investigated the utility of deep generative models for directly predicting local tissue volume change from lung CT images, bypassing computationally expensive iterative image registration and providing a method that can be utilized in scenarios where either one or two CT scans are available. METHODS: A residual regression convolutional neural network, called Reg3DNet+, is proposed for directly regressing high-resolution images of local tissue volume change (i.e., Jacobian) from CT images. Image registration was performed between lung volumes at total lung capacity (TLC) and functional residual capacity (FRC) using a tissue mass- and structure-preserving registration algorithm. The Jacobian image was calculated from the registration-derived displacement field and used as the ground truth for local tissue volume change. Four separate Reg3DNet+ models were trained to predict Jacobian images using a multifactorial study design to compare the effects of network input (i.e., single image vs. paired images) and output space (i.e., FRC vs. TLC). The models were trained and evaluated on image datasets from the COPDGene study. Models were evaluated against the registration-derived Jacobian images using local, regional, and global evaluation metrics. RESULTS: Statistical analysis revealed that both factors - network input and output space - were significant determinants for change in evaluation metrics. Paired-input models performed better than single-input models, and model performance was better in the output space of FRC rather than TLC. Mean structural similarity index for paired-input models was 0.959 and 0.956 for FRC and TLC output spaces, respectively, and for single-input models was 0.951 and 0.937. Global evaluation metrics demonstrated correlation between registration-derived Jacobian mean and predicted Jacobian mean: coefficient of determination (r2 ) for paired-input models was 0.974 and 0.938 for FRC and TLC output spaces, respectively, and for single-input models was 0.598 and 0.346. After correcting for effort, registration-derived lobar volume change was strongly correlated with the predicted lobar volume change: for paired-input models r2 was 0.899 for both FRC and TLC output spaces, and for single-input models r2 was 0.803 and 0.862, respectively. CONCLUSIONS: Convolutional neural networks can be used to directly predict local tissue mechanics, eliminating the need for computationally expensive image registration. Networks that use paired CT images acquired at TLC and FRC allow for more accurate prediction of local tissue expansion compared to networks that use a single image. Networks that only require a single input image still show promising results, particularly after correcting for effort, and allow for local tissue expansion estimation in cases where multiple CT scans are not available. For single-input networks, the FRC image is more predictive of local tissue volume change compared to the TLC image.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Algoritmos , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador
10.
Med Phys ; 50(10): 6366-6378, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36999913

RESUMO

BACKGROUND: Biomarkers estimating local lung ventilation have been derived from computed tomography (CT) imaging using various image acquisition and post-processing techniques. CT-ventilation biomarkers have potential clinical use in functional avoidance radiation therapy (RT), in which RT treatment plans are optimized to reduce dose delivered to highly ventilated lung. Widespread clinical implementation of CT-ventilation biomarkers necessitates understanding of biomarker repeatability. Performing imaging within a highly controlled experimental design enables quantification of error associated with remaining variables. PURPOSE: To characterize CT-ventilation biomarker repeatability and dependence on image acquisition and post-processing methodology in anesthetized and mechanically ventilated pigs. METHODS: Five mechanically ventilated Wisconsin Miniature Swine (WMS) received multiple consecutive four-dimensional CT (4DCT) and maximum inhale and exhale breath-hold CT (BH-CT) scans on five dates to generate CT-ventilation biomarkers. Breathing maneuvers were controlled with an average tidal volume difference <200 cc. As surrogates for ventilation, multiple local expansion ratios (LERs) were calculated from the acquired CT scans using Jacobian-based post-processing techniques. L E R 2 $LER_2$ measured local expansion between an image pair using either inhale and exhale BH-CT images or two 4DCT breathing phase images. L E R N $LER_N$ measured the maximum local expansion across the 4DCT breathing phase images. Breathing maneuver consistency, intra- and interday biomarker repeatability, image acquisition and post-processing technique dependence were quantitatively analyzed. RESULTS: Biomarkers showed strong agreement with voxel-wise Spearman correlation ρ > 0.9 $\rho > 0.9$ for intraday repeatability and ρ > 0.8 $\rho > 0.8$ for all other comparisons, including between image acquisition techniques. Intra- and interday repeatability were significantly different (p < 0.01). LER2 and LERN post-processing did not significantly affect intraday repeatability. CONCLUSIONS: 4DCT and BH-CT ventilation biomarkers derived from consecutive scans show strong agreement in controlled experiments with nonhuman subjects.


Assuntos
Neoplasias Pulmonares , Humanos , Suínos , Animais , Neoplasias Pulmonares/radioterapia , Ventilação Pulmonar , Respiração , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional/métodos , Biomarcadores
11.
Sci Rep ; 13(1): 9377, 2023 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-37296169

RESUMO

Imaging biomarkers can assess disease progression or prognoses and are valuable tools to help guide interventions. Particularly in lung imaging, biomarkers present an opportunity to extract regional information that is more robust to the patient's condition prior to intervention than current gold standard pulmonary function tests (PFTs). This regional aspect has particular use in functional avoidance radiation therapy (RT) in which treatment planning is optimized to avoid regions of high function with the goal of sparing functional lung and improving patient quality of life post-RT. To execute functional avoidance, detailed dose-response models need to be developed to identify regions which should be protected. Previous studies have begun to do this, but for these models to be clinically translated, they need to be validated. This work validates two metrics that encompass the main components of lung function (ventilation and perfusion) through post-mortem histopathology performed in a novel porcine model. With these methods validated, we can use them to study the nuanced radiation-induced changes in lung function and develop more advanced models.


Assuntos
Neoplasias Pulmonares , Suínos , Animais , Neoplasias Pulmonares/radioterapia , Qualidade de Vida , Pulmão/diagnóstico por imagem , Perfusão , Tomografia Computadorizada por Raios X , Biomarcadores , Planejamento da Radioterapia Assistida por Computador/métodos
12.
Radiother Oncol ; 182: 109553, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36813178

RESUMO

PURPOSE: To identify metrics of radiation dose delivered to highly ventilated lung that are predictive of radiation-induced pneumonitis. METHODS AND MATERIALS: A cohort of 90 patients with locally advanced non-small cell lung cancer treated with standard fractionated radiation therapy (RT) (60-66 Gy in 30-33 fractions) were evaluated. Regional lung ventilation was determined from pre-RT 4-dimensional computed tomography (4DCT) using the Jacobian determinant of a B-spline deformable image registration to estimate lung tissue expansion during respiration. Multiple voxel-wise population- and individual-based thresholds for defining high functioning lung were considered. Mean dose and volumes receiving dose ≥ 5-60 Gy were analyzed for both total lung-ITV (MLD,V5-V60) and highly ventilated functional lung-ITV (fMLD,fV5-fV60). The primary endpoint was symptomatic grade 2+ (G2+) pneumonitis. Receiver operator curve (ROC) analyses were used to identify predictors of pneumonitis. RESULTS: G2+ pneumonitis occurred in 22.2% of patients, with no differences between stage, smoking status, COPD, or chemo/immunotherapy use between G<2 and G2+ patients (P≥ 0.18). Highly ventilated lung was defined as voxels exceeding the population-wide median of 18% voxel-level expansion. All total and functional metrics were significantly different between patients with and without pneumonitis (P≤ 0.039). Optimal ROC points predicting pneumonitis from functional lung dose were fMLD ≤ 12.3 Gy, fV5 ≤ 54% and fV20 ≤ 19 %. Patients with fMLD ≤ 12.3 Gy had a 14% risk of developing G2+ pneumonitis whereas risk significantly increased to 35% for those with fMLD > 12.3 Gy (P = 0.035). CONCLUSIONS: Dose to highly ventilated lung is associated with symptomatic pneumonitis and treatment planning strategies should focus on limiting dose to functional regions. These findings provide important metrics to be used in functional lung avoidance RT planning and designing clinical trials.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Pneumonite por Radiação , Humanos , Neoplasias Pulmonares/radioterapia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Pulmão/diagnóstico por imagem , Pneumonite por Radiação/diagnóstico , Pneumonite por Radiação/etiologia , Respiração
13.
J Affect Disord ; 340: 269-279, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37562560

RESUMO

BACKGROUND: The neural underpinnings of bipolar disorder (BD) remain poorly understood. The cerebellum is ideally positioned to modulate emotional regulation circuitry yet has been understudied in BD. Literature suggests differences in cerebellar activity and metabolism in BD, however findings on structural differences remain contradictory. Potential reasons include combining BD subtypes, small sample sizes, and potential moderators such as genetics, adverse childhood experiences (ACEs), and pharmacotherapy. METHODS: We collected 3 T MRI scans from participants with (N = 131) and without (N = 81) BD type I, as well as blood and questionnaires. We assessed differences in cerebellar volumes and explored potentially influential factors. RESULTS: The cerebellar cortex was smaller bilaterally in participants with BD. Polygenic propensity score did not predict any cerebellar volumes, suggesting that non-genetic factors may have greater influence on the cerebellar volume difference we observed in BD. Proportionate cerebellar white matter volumes appeared larger with more ACEs, but this may result from reduced ICV. Time from onset and symptom burden were not associated with cerebellar volumes. Finally, taking sedatives was associated with larger cerebellar white matter and non-significantly larger cortical volume. LIMITATIONS: This study was cross-sectional, limiting interpretation of possible mechanisms. Most of our participants were White, which could limit the generalizability. Additionally, we did not account for potential polypharmacy interactions. CONCLUSIONS: These findings suggest that external factors, such as sedatives and childhood experiences, may influence cerebellum structure in BD and may mask underlying differences. Accounting for such variables may be critical for consistent findings in future studies.


Assuntos
Transtorno Bipolar , Humanos , Transtorno Bipolar/psicologia , Estudos Transversais , Cerebelo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Córtex Cerebelar
14.
bioRxiv ; 2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36778335

RESUMO

Purpose: Studies of the neural underpinnings of bipolar type I disorder have focused on the emotional control network. However, there is also growing evidence for cerebellar involvement, including abnormal structure, function, and metabolism. Here, we sought to assess functional connectivity of the cerebellum with the cerebrum in bipolar disorder and to assess whether any effects might depend on mood. Methods: This cross-sectional study enrolled 128 participants with bipolar type I disorder and 83 control comparison participants who completed a 3T MRI scan, which included anatomical imaging as well as resting state BOLD imaging. Functional connectivity of the cerebellar vermis to all other brain regions was assessed. Based on quality control metrics of the fMRI data, 109 participants with bipolar disorder and 79 controls were used to in the statistical analysis comparing connectivity of the vermis as well as associations with mood. Potential impacts of medications were also explored. Results: Functional connectivity of the cerebellar vermis in bipolar disorder was found to differ significantly between brain regions known to be involved in the control of emotion, motor function, and language. While connections with emotion and motor control areas were significantly stronger in bipolar disorder, connection to a region associated language production was significantly weaker. In the participants with bipolar disorder, ratings of depression and mania were inversely associated with vermis functional connectivity. No effect of medications on these connections were observed. Conclusion: Together the findings suggest cerebellum may play a compensatory role in bipolar disorder and when it can no longer fulfill this role, depression and mania develop. The proximity of the cerebellar vermis to the skull may make this region a potential target for treatment with transcranial magnetic stimulation.

15.
Front Psychiatry ; 14: 1147540, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37215681

RESUMO

Purpose: Studies of the neural underpinnings of bipolar type I disorder have focused on the emotional control network. However, there is also growing evidence for cerebellar involvement, including abnormal structure, function, and metabolism. Here, we sought to assess functional connectivity of the cerebellar vermis with the cerebrum in bipolar disorder and to assess whether connectivity might depend on mood. Methods: This cross-sectional study enrolled 128 participants with bipolar type I disorder and 83 control comparison participants who completed a 3 T magnetic resonance imaging (MRI) study, which included anatomical as well as resting state Blood Oxygenation Level Dependent (BOLD) imaging. Functional connectivity of the cerebellar vermis to all other brain regions was assessed. Based on quality control metrics of the fMRI data, 109 participants with bipolar disorder and 79 controls were included in the statistical analysis comparing connectivity of the vermis. In addition, the data was explored for the potential impacts of mood, symptom burden, and medication in those with bipolar disorder. Results: Functional connectivity between the cerebellar vermis and the cerebrum was found to be aberrant in bipolar disorder. The connectivity of the vermis was found to be greater in bipolar disorder to regions involved in motor control and emotion (trending), while reduced connectivity was observed to a region associated with language production. In the participants with bipolar disorder, past depression symptom burden affected connectivity; however, no effects of medication were observed. Functional connectivity between the cerebellar vermis and all other regions revealed an inverse association with current mood ratings. Conclusion: Together the findings may suggest that the cerebellum plays a compensatory role in bipolar disorder. The proximity of the cerebellar vermis to the skull may make this region a potential target for treatment with transcranial magnetic stimulation.

16.
Lancet Digit Health ; 5(2): e83-e92, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36707189

RESUMO

BACKGROUND: Quantitative CT is becoming increasingly common for the characterisation of lung disease; however, its added potential as a clinical tool for predicting severe exacerbations remains understudied. We aimed to develop and validate quantitative CT-based models for predicting severe chronic obstructive pulmonary disease (COPD) exacerbations. METHODS: We analysed the Subpopulations and Intermediate Outcome Measures In COPD Study (SPIROMICS) cohort, a multicentre study done at 12 clinical sites across the USA, of individuals aged 40-80 years from four strata: individuals who never smoked, individuals who smoked but had normal spirometry, individuals who smoked and had mild to moderate COPD, and individuals who smoked and had severe COPD. We used 3-year follow-up data to develop logistic regression classifiers for predicting severe exacerbations. Predictors included age, sex, race, BMI, pulmonary function, exacerbation history, smoking status, respiratory quality of life, and CT-based measures of density gradient texture and airway structure. We externally validated our models in a subset from the Genetic Epidemiology of COPD (COPDGene) cohort. Discriminative model performance was assessed using the area under the receiver operating characteristic curve (AUC), which was also compared with other predictors, including exacerbation history and the BMI, airflow obstruction, dyspnoea, and exercise capacity (BODE) index. We evaluated model calibration using calibration plots and Brier scores. FINDINGS: Participants in SPIROMICS were enrolled between Nov 12, 2010, and July 31, 2015. Participants in COPDGene were enrolled between Jan 10, 2008, and April 15, 2011. We included 1956 participants from the SPIROMICS cohort who had complete 3-year follow-up data: the mean age of the cohort was 63·1 years (SD 9·2) and 1017 (52%) were men and 939 (48%) were women. Among the 1956 participants, 434 (22%) had a history of at least one severe exacerbation. For the CT-based models, the AUC was 0·854 (95% CI 0·852-0·855) for at least one severe exacerbation within 3 years and 0·931 (0·930-0·933) for consistent exacerbations (defined as ≥1 acute episode in each of the 3 years). Models were well calibrated with low Brier scores (0·121 for at least one severe exacerbation; 0·039 for consistent exacerbations). For the prediction of at least one severe event during 3-year follow-up, AUCs were significantly higher with CT biomarkers (0·854 [0·852-0·855]) than exacerbation history (0·823 [0·822-0·825]) and BODE index 0·812 [0·811-0·814]). 6965 participants were included in the external validation cohort, with a mean age of 60·5 years (SD 8·9). In this cohort, AUC for at least one severe exacerbation was 0·768 (0·767-0·769; Brier score 0·088). INTERPRETATION: CT-based prediction models can be used for identification of patients with COPD who are at high risk of severe exacerbations. The newly identified CT biomarkers could potentially enable investigation into underlying disease mechanisms responsible for exacerbations. FUNDING: National Institutes of Health and the National Heart, Lung, and Blood Institute.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Qualidade de Vida , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Expiratório Forçado , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Biomarcadores , Tomografia Computadorizada por Raios X
17.
Med Phys ; 39(3): 1595-608, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22380392

RESUMO

PURPOSE: Lung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and 3D image registration can be used to locally estimate lung tissue expansion and contraction (regional lung volume change) by computing the determinant of the Jacobian matrix of the image registration deformation field. In this study, the authors examine the reproducibility of Jacobian-based measures of lung tissue expansion in two repeat 4DCT acquisitions of mechanically ventilated sheep and free-breathing humans. METHODS: 4DCT image data from three white sheep and nine human subjects were used for this analysis. In each case, two 4DCT studies were acquired for each subject within a short time interval. The animal subjects were anesthetized and mechanically ventilated, while the humans were awake and spontaneously breathing based on respiratory pacing audio cues. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm and the Jacobian of the registration deformation field was used to measure regional lung expansion. The Jacobian map from the baseline data set was compared to the Jacobian map from the followup data by measuring the voxel-by-voxel Jacobian ratio. RESULTS: In the animal subjects, the mean Jacobian ratio (baseline scan Jacobian divided by followup scan Jacobian, voxel-by-voxel) was 0.9984±0.021 (mean ± standard deviation, averaged over the entire lung region). The mean Jacobian ratio was 1.0224±0.058 in the human subjects. The reproducibility of the Jacobian values was found to be strongly dependent on the reproducibility of the subject's respiratory effort and breathing pattern. CONCLUSIONS: Lung expansion, a surrogate for lung function, can be assessed using two or more respiratory-gated CT image acquisitions. The results show that good reproducibility can be obtained in anesthetized, mechanically ventilated animals, but variations in respiratory effort and breathing patterns reduce reproducibility in spontaneously-breathing humans. The global linear normalization can globally compensate for breathing effort differences, but a homogeneous scaling does not account for differences in regional lung expansion rates. Additional work is needed to develop compensation procedures or normalization schemes that can account for local variations in lung expansion during respiration.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Pulmão/anatomia & histologia , Pulmão/diagnóstico por imagem , Adulto , Idoso , Animais , Feminino , Humanos , Pulmão/citologia , Pulmão/fisiologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Respiração , Respiração Artificial , Ovinos
18.
Med Phys ; 39(8): 5084-98, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22894434

RESUMO

PURPOSE: Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this paper, the authors propose a new regional measure of lung mechanics-the specific air volume change by corrected Jacobian. The authors compare this new measure, along with two existing registration based measures of lung ventilation, to a regional ventilation measurement derived from xenon-CT (Xe-CT) imaging. METHODS: 4DCT and Xe-CT datasets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). The authors show that the commonly used SAI measure can be derived from the direct SAJ measure by using the air-tissue mixture model and assuming there is no tissue volume change between the end inspiration and end expiration datasets. All three ventilation measures are evaluated by comparing to Xe-CT estimates of regional ventilation. RESULTS: After registration, the mean registration error is on the order of 1 mm. For cubical regions of interest (ROIs) in cubes with size 20 mm × 20 mm × 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r(2) = 0.75 and r(2) = 0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm × 8 mm × 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r(2) = 0.88, r(2) = 0.92, and r(2) = 0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. The authors demonstrate a linear relationship between the difference of specific air volume change and difference of tissue volume in all four animals (linear regression, average r(2) = 0.86). CONCLUSIONS: Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied. The SACJ introduced here, provides better correlations with Xe-CT based sV than the SAJ and SAI measures, thus providing an improved surrogate for regional ventilation.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Tomografia Computadorizada Espiral/métodos , Xenônio/química , Algoritmos , Animais , Desenho de Equipamento , Imageamento Tridimensional/métodos , Masculino , Modelos Estatísticos , Ventilação Pulmonar , Reprodutibilidade dos Testes , Ovinos , Software
19.
Med Phys ; 49(4): 2514-2530, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35106769

RESUMO

PURPOSE: Accurate assessment of thoracic aortic aneurysm (TAA) growth is important for appropriate clinical management. Maximal aortic diameter is the primary metric that is used to assess growth, but it suffers from substantial measurement variability. A recently proposed technique, termed vascular deformation mapping (VDM), is able to quantify three-dimensional aortic growth using clinical computed tomography angiography (CTA) data using an approach based on deformable image registration (DIR). However, the accuracy and robustness of VDM remains undefined given the lack of ground truth from clinical CTA data, and, furthermore, the performance of VDM relative to standard manual diameter measurements is unknown. METHODS: To evaluate the performance of the VDM pipeline for quantifying aortic growth, we developed a novel and systematic evaluation process to generate 76 unique synthetic CTA growth phantoms (based on 10 unique cases) with variable degrees and locations of aortic wall deformation. Aortic deformation was quantified using two metrics: area ratio (AR), defined as the ratio of surface area in triangular mesh elements and the magnitude of deformation in the normal direction (DiN) relative to the aortic surface. Using these phantoms, we further investigated the effects on VDM's measurement accuracy resulting from factors that influence the quality of clinical CTA data such as respiratory translations, slice thickness, and image noise. Lastly, we compare the measurement error of VDM TAA growth assessments against two expert raters performing standard diameter measurements of synthetic phantom images. RESULTS: Across our population of 76 synthetic growth phantoms, the median absolute error was 0.063 (IQR: 0.073-0.054) for AR and 0.181 mm (interquartile range [IQR]: 0.214-0.143 mm) for DiN. Median relative error was 1.4% for AR and 3.3 % $3.3\%$ for DiN at the highest tested noise level (contrast-to-noise ratio [CNR] = 2.66). Error in VDM output increased with slice thickness, with the highest median relative error of 1.5% for AR and 4.1% for DiN at a slice thickness of 2.0 mm. Respiratory motion of the aorta resulted in maximal absolute error of 3% AR and 0.6 mm in DiN, but bulk translations in aortic position had a very small effect on measured AR and DiN values (relative errors < 1 % $< 1\%$ ). VDM-derived measurements of magnitude and location of maximal diameter change demonstrated significantly high accuracy and lower variability compared to two expert manual raters ( p < 0.03 $p<0.03$ across all comparisons). CONCLUSIONS: VDM yields an accurate, three-dimensional assessment of aortic growth in TAA patients and is robust to factors such as image noise, respiration-induced translations, and differences in patient position. Further, VDM significantly outperformed two expert manual raters in assessing the magnitude and location of aortic growth despite optimized experimental measurement conditions. These results support validation of the VDM technique for accurate quantification of aortic growth in patients and highlight several important advantages over diameter measurements.


Assuntos
Aorta Torácica , Angiografia por Tomografia Computadorizada , Algoritmos , Aorta , Aorta Torácica/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
20.
Front Physiol ; 13: 1008526, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36324304

RESUMO

Vessel segmentation in the lung is an ongoing challenge. While many methods have been able to successfully identify vessels in normal, healthy, lungs, these methods struggle in the presence of abnormalities. Following radiotherapy, these methods tend to identify regions of radiographic change due to post-radiation therapytoxicities as vasculature falsely. By combining texture analysis and existing vasculature and masking techniques, we have developed a novel vasculature segmentation workflow that improves specificity in irradiated lung while preserving the sensitivity of detection in the rest of the lung. Furthermore, radiation dose has been shown to cause vascular injury as well as reduce pulmonary function post-RT. This work shows the improvements our novel vascular segmentation method provides relative to existing methods. Additionally, we use this workflow to show a dose dependent radiation-induced change in vasculature which is correlated with previously measured perfusion changes (R 2 = 0.72) in both directly irradiated and indirectly damaged regions of perfusion. These results present an opportunity to extend non-contrast CT-derived models of functional change following radiation therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA