Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Exp Cell Res ; 314(16): 2941-50, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18703050

RESUMO

The ST6Gal-I glycosyltransferase, which adds alpha2-6-linked sialic acids to glycoproteins, is overexpressed in colon adenocarcinoma, and enzyme activity is correlated with tumor cell invasiveness. Previously we reported that forced expression of oncogenic ras in HD3 colonocytes causes upregulation of ST6Gal-I, leading to increased alpha2-6 sialylation of beta1 integrins. To determine whether ras-induced sialylation is involved in promoting the tumor cell phenotype, we used shRNA to downregulate ST6Gal-I in ras-expressors, and then monitored integrin-dependent responses. Here we show that forced ST6Gal-I downregulation, leading to diminished alpha2-6 sialylation of integrins, inhibits cell adhesion to collagen I, a beta1 ligand. Correspondingly, collagen binding is reduced by enzymatic removal of cell surface sialic acids from ras-expressors with high ST6Gal-I levels (i.e., no shRNA). Cells with forced ST6Gal-I downregulation also exhibit decreased migration on collagen I and diminished invasion through Matrigel. Importantly, GD25 cells, which lack beta1 integrins (and ST6Gal-I), do not demonstrate differential invasiveness when forced to express ST6Gal-I, suggesting that the effects of variant sialylation are mediated specifically by beta1 integrins. The observation that cell migration and invasion can be blocked in oncogenic ras-expressing cells by forcing ST6Gal-I downregulation implicates differential sialylation as an important ras effector, and also suggests that ST6Gal-I is a promising therapeutic target.


Assuntos
Movimento Celular/fisiologia , Neoplasias do Colo , Integrinas/química , Integrinas/metabolismo , Invasividade Neoplásica , Ácidos Siálicos/metabolismo , Adenocarcinoma/metabolismo , Adenocarcinoma/patologia , Animais , Adesão Celular/fisiologia , Linhagem Celular Tumoral , Colágeno Tipo I/metabolismo , Neoplasias do Colo/metabolismo , Neoplasias do Colo/patologia , Humanos , Integrinas/genética , Camundongos , Invasividade Neoplásica/patologia , Neuraminidase/metabolismo , Isoformas de Proteínas/química , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Sialiltransferases/genética , Sialiltransferases/metabolismo , Proteínas ras/genética , Proteínas ras/metabolismo , beta-D-Galactosídeo alfa 2-6-Sialiltransferase
2.
Biomaterials ; 29(11): 1705-12, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18192004

RESUMO

Traditional cell culture substrates consist of static, flat surfaces although in vivo, cells exist on various dynamic topographies. We report development of a reconfigurable microtopographical system compatible with cell culture that is comprised of reversible wavy microfeatures on poly(dimethylsiloxane). Robust reversibility of the wavy micropattern is induced on the cell culture customized substrate by first plasma oxidizing the substrate to create a thin, brittle film on the surface and then applying and releasing compressive strain, to introduce and remove the microfeatures, respectively. The reversible topography was able to align, unalign, and realign C2C12 myogenic cell line cells repeatedly on the same substrate within 24 h intervals, and did not inhibit cell differentiation. The flexibility and simplicity of the materials and methods presented here provide a broadly applicable capability by which to investigate and compare dynamic cellular processes not yet easily studied using conventional in vitro culture substrates.


Assuntos
Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Animais , Linhagem Celular , Camundongos
3.
Biomaterials ; 29(24-25): 3461-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18490051

RESUMO

Ultra-smooth nanostructured diamond (USND) can be applied to greatly increase the wear resistance of orthopaedic implants over conventional designs. Herein we describe surface modification techniques and cytocompatibility studies performed on this new material. We report that hydrogen (H)-terminated USND surfaces supported robust mesenchymal stem cell (MSC) adhesion and survival, while oxygen- (O) and fluorine (F)-terminated surfaces resisted cell adhesion, indicating that USND can be modified to either promote or prevent cell/biomaterial interactions. Given the favorable cell response to H-terminated USND, this material was further compared with two commonly used biocompatible metals, titanium alloy (Ti-6Al-4V) and cobalt chrome (CoCrMo). MSC adhesion and proliferation were significantly improved on USND compared with CoCrMo, although cell adhesion was greatest on Ti-6Al-4V. Comparable amounts of the pro-adhesive protein, fibronectin, were deposited from serum on the three substrates. Finally, MSCs were induced to undergo osteoblastic differentiation on the three materials, and deposition of a mineralized matrix was quantified. Similar amounts of mineral were deposited onto USND and CoCrMo, whereas mineral deposition was slightly higher on Ti-6Al-4V. When coupled with recently published wear studies, these in vitro results suggest that USND has the potential to reduce debris particle release from orthopaedic implants without compromising osseointegration.


Assuntos
Materiais Biocompatíveis/metabolismo , Diamante/metabolismo , Células-Tronco Mesenquimais/metabolismo , Materiais Biocompatíveis/química , Proliferação de Células/efeitos dos fármacos , Diamante/química , Diamante/farmacologia , Fibronectinas/metabolismo , Humanos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/ultraestrutura , Microscopia Eletrônica de Varredura , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Ortopedia/métodos , Osseointegração/efeitos dos fármacos , Próteses e Implantes
4.
J Biomed Mater Res A ; 76(2): 279-87, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16265649

RESUMO

Improved methods to increase surface hardness of metallic biomedical implants are being developed in an effort to minimize the formation of wear debris particles that cause local pain and inflammation. However, for many implant surface treatments, there is a risk of film delamination due to the mismatch of mechanical properties between the hard surface and the softer underlying metal. In this article, we describe the surface modification of titanium alloy (Ti-6Al-4V), using microwave plasma chemical vapor deposition to induce titanium nitride formation by nitrogen diffusion. The result is a gradual transition from a titanium nitride surface to the bulk titanium alloy, without a sharp interface that could otherwise lead to delamination. We demonstrate that vitronectin adsorption, as well as the adhesion and spreading of human mesenchymal stem cells to plasma-nitrided titanium is equivalent to that of Ti-6Al-4V, while hardness is improved 3- to 4-fold. These in vitro results suggest that the plasma nitriding technique has the potential to reduce wear, and the resulting debris particle release, of biomedical implants without compromising osseointegration; thus, minimizing the possibility of implant loosening over time.


Assuntos
Materiais Revestidos Biocompatíveis/química , Células-Tronco Mesenquimais/citologia , Titânio/química , Adesão Celular , Forma Celular , Humanos , Teste de Materiais , Micro-Ondas , Falha de Prótese , Propriedades de Superfície , Vitronectina/farmacologia
5.
J Tissue Eng Regen Med ; 9(5): 577-83, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-23166109

RESUMO

Guided bone regeneration (GBR) barrier membranes are used to prevent soft tissue infiltration into the graft space during dental procedures that involve bone grafting. Chitosan materials have shown promise as GBR barrier membranes, due to their biocompatibility and predictable biodegradability, but degradation rates may still be too high for clinical applications. In this study, chitosan GBR membranes were electrospun using chitosan (70% deacetylated, 312 kDa, 5.5 w/v%), with or without the addition of 5 or 10 mm genipin, a natural crosslinking agent, in order to extend the degradation to meet the clinical target time frame of 4-6 months. Membranes were evaluated for fibre diameter, tensile strength, biodegradation rate, bond structure and cytocompatibility. Genipin addition, at 5 or 10 mm, resulted in median fibre diameters 184, 144 and 154 nm for uncrosslinked, 5 mm and 10 mm crosslinked, respectively. Crosslinking, examined by Fourier transform infrared spectroscopy, showed a decrease in N-H stretch as genipin levels were increased. Genipin-crosslinked mats exhibited only 22% degradation based on mass loss, as compared to 34% for uncrosslinked mats at 16 weeks in vitro. The ultimate tensile strength of the mats was increased by 165% to 32 MPa with 10 mm crosslinking as compared to the uncrosslinked mats. Finally, genipin-crosslinked mats supported the proliferation of SAOS-2 cells in a 5 day growth study, similar to uncrosslinked mats. These results suggest that electrospun chitosan mats may benefit from genipin crosslinking and have the potential to meet clinical degradation time frames for GBR applications.


Assuntos
Materiais Biocompatíveis/química , Quitosana/química , Reagentes de Ligações Cruzadas/química , Engenharia Tecidual/métodos , Regeneração Óssea , Osso e Ossos/patologia , Linhagem Celular Tumoral , Proliferação de Células , Sobrevivência Celular , Glutaral/química , Humanos , Iridoides/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Pressão , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Resistência à Tração
6.
Biomaterials ; 33(2): 524-34, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22014462

RESUMO

Bone-mimetic electrospun scaffolds consisting of polycaprolactone (PCL), collagen I and nanoparticulate hydroxyapatite (HA) have previously been shown to support the adhesion, integrin-related signaling and proliferation of mesenchymal stem cells (MSCs), suggesting these matrices serve as promising degradable substrates for osteoregeneration. However, the small pore sizes in electrospun scaffolds hinder cell infiltration in vitro and tissue-ingrowth into the scaffold in vivo, limiting their clinical potential. In this study, three separate techniques were evaluated for their capability to increase the pore size of the PCL/col I/nanoHA scaffolds: limited protease digestion, decreasing the fiber packing density during electrospinning, and inclusion of sacrificial fibers of the water-soluble polymer PEO. The PEO sacrificial fiber approach was found to be the most effective in increasing scaffold pore size. Furthermore, the use of sacrificial fibers promoted increased MSC infiltration into the scaffolds, as well as greater infiltration of endogenous cells within bone upon placement of scaffolds within calvarial organ cultures. These collective findings support the use of sacrificial PEO fibers as a means to increase the porosity of complex, bone-mimicking electrospun scaffolds, thereby enhancing tissue regenerative processes that depend upon cell infiltration, such as vascularization and replacement of the scaffold with native bone tissue.


Assuntos
Materiais Biomiméticos/química , Substitutos Ósseos/química , Colágeno Tipo I/química , Durapatita/química , Poliésteres/química , Alicerces Teciduais/química , Animais , Adesão Celular , Proliferação de Células , Matriz Extracelular/metabolismo , Masculino , Células-Tronco Mesenquimais/citologia , Microscopia Eletrônica de Varredura , Porosidade , Ratos , Ratos Sprague-Dawley , Engenharia Tecidual/métodos
7.
PLoS One ; 6(2): e16813, 2011 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-21346817

RESUMO

The performance of biomaterials designed for bone repair depends, in part, on the ability of the material to support the adhesion and survival of mesenchymal stem cells (MSCs). In this study, a nanofibrous bone-mimicking scaffold was electrospun from a mixture of polycaprolactone (PCL), collagen I, and hydroxyapatite (HA) nanoparticles with a dry weight ratio of 50/30/20 respectively (PCL/col/HA). The cytocompatibility of this tri-component scaffold was compared with three other scaffold formulations: 100% PCL (PCL), 100% collagen I (col), and a bi-component scaffold containing 80% PCL/20% HA (PCL/HA). Scanning electron microscopy, fluorescent live cell imaging, and MTS assays showed that MSCs adhered to the PCL, PCL/HA and PCL/col/HA scaffolds, however more rapid cell spreading and significantly greater cell proliferation was observed for MSCs on the tri-component bone-mimetic scaffolds. In contrast, the col scaffolds did not support cell spreading or survival, possibly due to the low tensile modulus of this material. PCL/col/HA scaffolds adsorbed a substantially greater quantity of the adhesive proteins, fibronectin and vitronectin, than PCL or PCL/HA following in vitro exposure to serum, or placement into rat tibiae, which may have contributed to the favorable cell responses to the tri-component substrates. In addition, cells seeded onto PCL/col/HA scaffolds showed markedly increased levels of phosphorylated FAK, a marker of integrin activation and a signaling molecule known to be important for directing cell survival and osteoblastic differentiation. Collectively these results suggest that electrospun bone-mimetic matrices serve as promising degradable substrates for bone regenerative applications.


Assuntos
Materiais Biomiméticos/farmacologia , Osso e Ossos/citologia , Colágeno Tipo I/química , Durapatita/química , Células-Tronco Mesenquimais/efeitos dos fármacos , Nanopartículas/química , Poliésteres/química , Adsorção , Animais , Materiais Biomiméticos/química , Adesão Celular/efeitos dos fármacos , Moléculas de Adesão Celular/química , Proliferação de Células/efeitos dos fármacos , Ativação Enzimática/efeitos dos fármacos , Proteína-Tirosina Quinases de Adesão Focal/metabolismo , Humanos , Masculino , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Fosforilação/efeitos dos fármacos , Ratos , Resistência à Tração , Alicerces Teciduais/química
8.
Biomaterials ; 30(10): 1898-909, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19157536

RESUMO

Integrin-binding peptides increase cell adhesion to naive hydroxyapatite (HA), however, in the body, HA becomes rapidly modified by protein adsorption. Previously we reported that, when combined with an adsorbed protein layer, RGD peptides interfered with cell adhesion to HA. In the current study we evaluated mesenchymal stem cell (MSC) interactions with HA disks coated with the collagen-mimetic peptides, DGEA, P15 and GFOGER. MSCs adhered equally well to disks coated with DGEA, P15, or collagen I, and all three substrates, but not GFOGER, supported greater cell adhesion than uncoated HA. When peptide-coated disks were overcoated with proteins from serum or the tibial microenvironment, collagen mimetics did not inhibit MSC adhesion, as was observed with RGD, however neither did they enhance adhesion. Given that activation of collagen-selective integrins stimulates osteoblastic differentiation, we monitored osteocalcin secretion and alkaline phosphatase activity from MSCs adherent to DGEA or P15-coated disks. Both of these osteoblastic markers were upregulated by DGEA and P15, in the presence and absence of differentiation-inducing media. Finally, bone formation on HA tibial implants was increased by the collagen mimetics. Collectively these results suggest that collagen-mimetic peptides improve osseointegration of HA, most probably by stimulating osteoblastic differentiation, rather than adhesion, of MSCs.


Assuntos
Colágeno/química , Durapatita/química , Células-Tronco Mesenquimais/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Peptídeos/química , Peptídeos/farmacologia , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Western Blotting , Diferenciação Celular/efeitos dos fármacos , Ensaio de Imunoadsorção Enzimática , Humanos , Células-Tronco Mesenquimais/citologia , Mimetismo Molecular , Peptídeos/síntese química
9.
J Biomed Mater Res B Appl Biomater ; 85(1): 140-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17853416

RESUMO

BACKGROUND: Some loss of joint prostheses has been attributed to osteolytic loosening associated with debris from wear of polyethylene articulating against metal alloys. Reduced polyethylene wear has been reported with ceramics serving as an alternative counterface. METHODS: Nanostructured Diamond (NSD) coatings were deposited onto Ti6Al4V by microwave plasma-assisted chemical vapor deposition, with both hydrogen-rich (H-NSD) and helium-rich (He-NSD) feedgas mixtures. Pin-on-disk wear tests of polyethylene against NSD and CoCr were performed in serum lubrication at body temperature. Scanning electron microscopy was used to examine surface morphology, and nanoindentation was used to determine hardness and modulus of the polyethylene wear surfaces. Raman spectroscopy, surface roughness, and wettability analyses of the NSD coatings were performed. RESULTS: Raman spectroscopy confirmed sp(2) and sp(3) bonded carbon in the NSD coatings. No significant differences in wear factors were found between polyethylene on H-NSD, He-NSD, and CoCr, despite higher roughness and friction coefficients for the He-NSD and H-NSD coatings, compared with CoCr. Contact angles for the diamond coatings were reduced following the wear tests, indicating that these surfaces became more hydrophilic. Numerous small protuberances were observed on pins articulated against CoCr, and a single, large protuberance was observed in polyethylene-on-NSD. These features were conjectured to be reconsolidated polyethylene particles. Nanoindentation modulus and hardness of the worn polyethylene surfaces were lower for polyethylene-on-diamond than for polyethylene-on-CoCr. CONCLUSIONS: As a counterface to polyethylene, NSD-coated Ti6Al4V produced wear factors comparable to CoCr in the present pin-on-disk tests, a promising step towards its use in joint replacement bearing applications.


Assuntos
Materiais Revestidos Biocompatíveis/química , Diamante/química , Teste de Materiais , Nanoestruturas , Polietilenos/química , Ligas/química , Ligas de Cromo/química , Força Compressiva , Análise de Falha de Equipamento , Fricção , Humanos , Tamanho da Partícula , Falha de Prótese , Análise Espectral Raman , Propriedades de Superfície , Titânio/química , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA