RESUMO
Methods of cognitive enhancement for humans are most impactful when they generalize across tasks. However, the extent to which such "transfer" is possible via interventions is widely debated. In addition, the contribution of excitatory and inhibitory processes to such transfer is unknown. Here, in a large-scale neuroimaging individual differences study with humans (both sexes), we paired multitasking training and noninvasive brain stimulation (transcranial direct current stimulation, tDCS) over multiple days and assessed performance across a range of paradigms. In addition, we varied tDCS dosage (1.0 and 2.0â mA), electrode montage (left or right prefrontal regions), and training task (multitasking vs a control task) and assessed GABA and glutamate concentrations via ultrahigh field 7T magnetic resonance spectroscopy. Generalized benefits were observed in spatial attention, indexed by visual search performance, when multitasking training was combined with 1.0â mA stimulation targeting either the left or right prefrontal cortex (PFC). This transfer effect persisted for â¼30â d post intervention. Critically, the transferred benefits associated with right prefrontal tDCS were predicted by pretraining concentrations of glutamate in the PFC. Thus, the effects of this combined stimulation and training protocol appear to be linked predominantly to excitatory brain processes.
Assuntos
Ácido Glutâmico , Aprendizagem , Córtex Pré-Frontal , Estimulação Transcraniana por Corrente Contínua , Humanos , Masculino , Feminino , Estimulação Transcraniana por Corrente Contínua/métodos , Adulto , Ácido Glutâmico/metabolismo , Córtex Pré-Frontal/fisiologia , Córtex Pré-Frontal/metabolismo , Adulto Jovem , Aprendizagem/fisiologia , Ácido gama-Aminobutírico/metabolismo , Atenção/fisiologia , Espectroscopia de Ressonância Magnética/métodosRESUMO
PURPOSE: Ultra-high field (UHF) provides improved SNR which greatly benefits SNR starved imaging techniques such as perfusion imaging. However, transmit field (B1 + ) inhomogeneities commonly observed at UHF hinders the excitation uniformity. Here we show how replacing standard excitation pulses with parallel transmit pulses can improve efficiency of velocity selective labeling. METHODS: The standard tip-down and tip-up excitation pulses found in a velocity selective preparation module were replaced with tailored non-selective kT -points pulse solutions. Bloch simulations and experimental validation on a custom-built flow phantom and in vivo was performed to evaluate different pulse configurations in circularly polarized mode (CP-mode) and parallel transmit (pTx) mode. RESULTS: Tailored pTx pulses significantly improved velocity selective labeling fidelity and signal uniformity. The transverse magnetization normalized RMS error was reduced from 0.489 to 0.047 when compared to standard rectangular pulses played in CP-mode. Simulations showed that manipulation of time symmetry in the tailored pTx pulses is vital in minimizing residual magnetization. In addition, in vivo experiments achieved a 44% lower RF power output and a shorter pulse duration when compared to using adiabatic pulses in CP-mode. CONCLUSION: Using tailored pTx pulses for excitation within a velocity selective labeling preparation mitigated transmit field artifacts and improved SNR and contrast fidelity. The improvement in labeling efficiency highlights the potential of using pTx to improve robustness and accessibility of flow-based sequences such as velocity selective spin labeling at ultra-high field.
Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Artefatos , AlgoritmosRESUMO
PURPOSE: The purpose of this study is to improve the image quality of diffusion-weighted images obtained with a single RF transmit channel 7 T MRI setup using time-resampled frequency-offset corrected inversion (TR-FOCI) pulses to refocus the spins in a twice-refocused spin-echo readout scheme. METHODS: We replaced the conventional Shinnar-Le Roux-pulses in the twice refocused diffusion sequence with TR-FOCI pulses. The slice profiles were evaluated in simulation and experimentally in phantoms. The image quality was evaluated in vivo comparing the Shinnar-Le Roux and TR-FOCI implementation using a b value of 0 and of 1000 s/mm2. RESULTS: The b0 and diffusion-weighted images acquired using the modified sequence improved the image quality across the whole brain. A region of interest-based analysis showed an SNR increase of 113% and 66% for the nondiffusion-weighted (b0) and the diffusion-weighted (b = 1000 s/mm2) images in the temporal lobes, respectively. Investigation of all slices showed that the adiabatic pulses mitigated B 1 + $$ {B}_1^{+} $$ inhomogeneity globally using a conventional single-channel transmission setup. CONCLUSION: The TR-FOCI pulse can be used in a twice-refocused spin-echo diffusion pulse sequence to mitigate the impact of B 1 + $$ {B}_1^{+} $$ inhomogeneity on the signal intensity across the brain at 7 T. However, further work is needed to address SAR limitations.
Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Imagens de FantasmasRESUMO
High acceleration factors in radial magnetic resonance fingerprinting (MRF) of the prostate lead to strong streak-like artefacts from flow in the femoral blood vessels, possibly concealing important anatomical information. Region-optimised virtual (ROVir) coils is a beamforming-based framework to create virtual coils that maximise signal in a region of interest while minimising signal in a region of interference. In this study, the potential of removing femoral flow streak artefacts in prostate MRF using ROVir coils is demonstrated in silico and in vivo. The ROVir framework was applied to radial MRF k-space data in an automated pipeline designed to maximise prostate signal while minimising signal from the femoral vessels. The method was tested in 15 asymptomatic volunteers at 3 T. The presence of streaks was visually assessed and measurements of whole prostate T1, T2 and signal-to-noise ratio (SNR) with and without streak correction were examined. In addition, a purpose-built simulation framework in which blood flow through the femoral vessels can be turned on and off was used to quantitatively evaluate ROVir's ability to suppress streaks in radial prostate MRF. In vivo it was shown that removing selected ROVir coils visibly reduces streak-like artefacts from the femoral blood flow, without increasing the reconstruction time. On average, 80% of the prostate SNR was retained. A similar reduction of streaks was also observed in silico, while the quantitative accuracy of T1 and T2 mapping was retained. In conclusion, ROVir coils efficiently suppress streaking artefacts from blood flow in radial MRF of the prostate, thereby improving the visual clarity of the images, without significant sacrifices to acquisition time, reconstruction time and accuracy of quantitative values. This is expected to help enable T1 and T2 mapping of prostate cancer in clinically viable times, aiding differentiation between prostate cancer from noncancer and healthy prostate tissue.
Assuntos
Artefatos , Imageamento por Ressonância Magnética , Próstata , Humanos , Masculino , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Adulto , Pessoa de Meia-Idade , Razão Sinal-Ruído , Simulação por Computador , Fêmur/diagnóstico por imagem , Fêmur/irrigação sanguíneaRESUMO
In this work, we introduce a super-resolution method that generates a high-resolution (HR) sodium (23 Na) image from simultaneously acquired low-resolution (LR) 23 Na density-weighted MRI and HR proton density, T1 , and T2 maps from proton (1 H) MR fingerprinting in the brain at 7 T. The core of our method is a partial least squares regression between the HR (1 H) images and the LR (23 Na) image. An iterative loop and deconvolution with the point spread function of each acquired image were included in the algorithm to generate a final HR 23 Na image without losing features from the LR 23 Na image. The method was applied to simultaneously acquired HR proton and LR sodium data with in-plane resolution ratios between sodium and proton data of 3.8 and 1.9 and the same slice thickness. Four volunteers were scanned to evaluate the method's performance. For the data with a resolution ratio of 3.8, the mean absolute difference between the generated and ground truth HR 23 Na images was in the range of 1.5%-7.2% of the ground truth with a multiscale structural similarity index (M-SSIM) of 0.93 ± 0.03. For the data with a resolution ratio of 1.9, the mean absolute difference was in the range of 4.8%-6.3% with an M-SSIM of 0.95 ± 0.01.
Assuntos
Prótons , Sódio , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , AlgoritmosRESUMO
BACKGROUND: Magnetic resonance fingerprinting (MRF) techniques have been recently described for simultaneous multiparameter cartilage mapping of the knee although investigation of their ability to detect early cartilage degeneration remains limited. PURPOSE: To investigate age-dependent changes in knee cartilage T1 , T2 , and T1p relaxation times measured using a three-dimensional (3D) MRF sequence in healthy volunteers. STUDY TYPE: Prospective. SUBJECTS: The study group consisted of 24 healthy asymptomatic human volunteers (15 males with mean age 34.9 ± 14.4 years and 9 females with mean age 44.5 ± 13.1 years). FIELD STRENGTH/SEQUENCE: A 3.0 T gradient-echo-based 3D-MRF sequence was used to simultaneously create proton density-weighted images and T1 , T2 , and T1p maps of knee cartilage. ASSESSMENT: Mean global cartilage and regional cartilage (lateral femur, lateral tibia, medial femur, medial tibia, and patella) T1 , T2 , and T1ρ relaxation times of the knee were measured. STATISTICAL TESTS: Kruskal-Wallis tests were used to compared cartilage T1 , T2 , and T1ρ relaxation times between different age groups, while Spearman correlation coefficients was used to determine the association between age and cartilage T1 , T2 , and T1ρ relaxation times. The value of P < 0.05 was considered statistically significant. RESULTS: Higher age groups showed higher global and regional cartilage T1 , T2 , and T1ρ . There was a significant difference between age groups in global cartilage T2 and T1ρ but no significant difference (P = 0.13) in global cartilage T1. Significant difference was also present between age groups in cartilage T2 and T1ρ for medial femur cartilage and medial tibia cartilage. There were significant moderate correlations between age and T2 and T1ρ for global cartilage (R2 = 0.63-0.64), medial femur cartilage (R2 = 0.50-0.56), and medial tibia cartilage (R2 = 0.54-0.66). CONCLUSION: Cartilage T2 and T1p relaxation times simultaneously measured using a 3D-MRF sequence in healthy volunteers showed age-dependent changes in knee cartilage, primarily within the medial compartment.
Assuntos
Cartilagem Articular , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Joelho , Imageamento por Ressonância Magnética/métodosRESUMO
BACKGROUND: Magnetic resonance fingerprinting (MRF) is a method to speed up acquisition of quantitative MRI data. However, MRF does not usually produce contrast-weighted images that are required by radiologists, limiting reachable total scan time improvement. Contrast synthesis from MRF could significantly decrease the imaging time. PURPOSE: To improve clinical utility of MRF by synthesizing contrast-weighted MR images from the quantitative data provided by MRF, using U-nets that were trained for the synthesis task utilizing L1- and perceptual loss functions, and their combinations. STUDY TYPE: Retrospective. POPULATION: Knee joint MRI data from 184 subjects from Northern Finland 1986 Birth Cohort (ages 33-35, gender distribution not available). FIELD STRENGTH AND SEQUENCE: A 3 T, multislice-MRF, proton density (PD)-weighted 3D-SPACE (sampling perfection with application optimized contrasts using different flip angle evolution), fat-saturated T2-weighted 3D-space, water-excited double echo steady state (DESS). ASSESSMENT: Data were divided into training, validation, test, and radiologist's assessment sets in the following way: 136 subjects to training, 3 for validation, 3 for testing, and 42 for radiologist's assessment. The synthetic and target images were evaluated using 5-point Likert scale by two musculoskeletal radiologists blinded and with quantitative error metrics. STATISTICAL TESTS: Friedman's test accompanied with post hoc Wilcoxon signed-rank test and intraclass correlation coefficient. The statistical cutoff P <0.05 adjusted by Bonferroni correction as necessary was utilized. RESULTS: The networks trained in the study could synthesize conventional images with high image quality (Likert scores 3-4 on a 5-point scale). Qualitatively, the best synthetic images were produced with combination of L1- and perceptual loss functions and perceptual loss alone, while L1-loss alone led to significantly poorer image quality (Likert scores below 3). The interreader and intrareader agreement were high (0.80 and 0.92, respectively) and significant. However, quantitative image quality metrics indicated best performance for the pure L1-loss. DATA CONCLUSION: Synthesizing high-quality contrast-weighted images from MRF data using deep learning is feasible. However, more studies are needed to validate the diagnostic accuracy of these synthetic images. EVIDENCE LEVEL: 4. TECHNICAL EFFICACY: Stage 1.
Assuntos
Aprendizado Profundo , Humanos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodosRESUMO
PURPOSE: To develop a 3D MR technique to simultaneously acquire proton multiparametric maps (T1 , T2 , and proton density) and sodium density weighted images over the whole brain. METHODS: We implemented a 3D stack-of-stars MR pulse sequence which consists of interleaved proton (1 H) and sodium (23 Na) excitations, tailored slice encoding gradients that can encode the same slice for both nuclei, and simultaneous readout with different radial trajectories (1 H, full-radial; 23 Na, center-out radial). The receive chain of our 7T scanner was modified to enable simultaneous acquisition of 1 H and 23 Na signal. A heuristically optimized flip angle train was implemented for proton MR fingerprinting (MRF). The SNR and the accuracy of proton T1 and T2 were evaluated in phantoms. Finally, in vivo application of the method was demonstrated in five healthy subjects. RESULTS: The SNR for the simultaneous measurement was almost identical to that for the single-nucleus measurements (<2% change). The proton T1 and T2 maps remained similar to the results from a reference 2D MRF technique (normalized RMS error in T1 ≈ 4.2% and T2 ≈ 11.3%). Measurements in healthy subjects corroborated these results and demonstrated the feasibility of our method for in vivo application. The in vivo T1 values measured using our method were lower than the results measured by other conventional techniques. CONCLUSIONS: With the 3D simultaneous implementation, we were able to acquire sodium and proton density weighted images in addition to proton T1 , T2 , and B1+ from 1 H MRF that covers the whole brain volume within 21 min.
Assuntos
Processamento de Imagem Assistida por Computador , Prótons , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , SódioRESUMO
Quantitative MRI can detect early biochemical changes in cartilage, but its bilateral use in clinical routines is challenging. The aim of this prospective study was to demonstrate the feasibility of magnetic resonance fingerprinting for bilateral simultaneous T1 , T2 , and T1ρ mapping of the hip joint. The study population consisted of six healthy volunteers with no known trauma or pain in the hip. Monoexponential T1 , T2 , and T1ρ relaxation components were assessed in femoral lateral, superolateral, and superomedial, and inferior, as well as acetabular, superolateral, and superomedial subregions in left and right hip cartilage. Aligned ranked nonparametric factorial analysis was used to assess the side's impact on the subregions. Kruskal-Wallis and Wilcoxon tests were used to compare subregions, and coefficient of variation to assess repeatability. Global averages of T1 (676.0 ± 45.4 and 687.6 ± 44.5 ms), T2 (22.5 ± 2.6 and 22.1 ± 2.5 ms), and T1ρ (38.2 ± 5.5 and 38.2 ± 5.5 ms) were measured in the left and right hip, and articular cartilage, respectively. The Kruskal-Wallis test showed a significant difference between different subregions' relaxation times regardless of the hip side (p < 0.001 for T1 , p = 0.012 for T2 , and p < 0.001 for T1ρ ). The Wilcoxon test showed that T1 of femoral layers was significantly (p < 0.003) higher than that for acetabular cartilage. The experiments showed excellent repeatability with CVrms of 1%, 2%, and 4% for T1 , T2 , and T1ρ, respectively. It was concluded that bilateral T1 , T2 , and T1ρ relaxation times, as well as B1+ maps, can be acquired simultaneously from hip joints using the proposed MRF sequence.
Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Humanos , Espectroscopia de Ressonância Magnética , Estudos ProspectivosRESUMO
PURPOSE: To develop a novel MR-fingerprinting (MRF) pulse sequence that is insensitive to B1+ and B0 imperfections for simultaneous T1 , T2 , and T1ρ relaxation mapping. METHODS: We implemented a totally balanced spin-lock (TB-SL) module to encode T1ρ relaxation into an existing MRF framework that encoded T1 and T2 . The spin-lock module used two 180° pulses with compensatory phases to reduce T1ρ sensitivity to B1 and B0 inhomogeneities. We compared T1ρ measured using TB-SL MRF in Bloch simulations, model agar phantoms, and in vivo experiments to those with a self-compensated spin-lock preparation module (SC-SL). The TB-SL MRF repeatability was evaluated in maps acquired in the lower leg skeletal muscle of 12 diabetic peripheral neuropathy patients, scanned two times each during visits separated by about 30 days. RESULTS: The phantom relaxation times measured with TB-SL and SC-SL MRF were in good agreement with reference values in regions with low B1 inhomogeneities. Compared with SC-SL, TB-SL MRF showed in experiments greater robustness against severe B1 inhomogeneities and in Bloch simulations greater robustness against B1 and B0 . We measured with TB-SL MRF an average T1 = 950.1 ± 28.7 ms, T2 = 26.0 ± 1.2 ms, and T1ρ = 31.7 ± 3.2 ms in skeletal muscle across patients. Bland-Altman analysis demonstrated low bias between TB-SL and SC-SL MRF and between TB-SL MRF maps acquired in two visits. The coefficient of variation was less than 3% for all measurements. CONCLUSION: The proposed TB-SL MRF sequence is fast and insensitive to B1+ and B0 imperfections. It can simultaneously map T1 , T2 , T1ρ , and B1+ in a single scan and can potentially be used to study muscle composition.
Assuntos
Perna (Membro) , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador , Músculo Esquelético/diagnóstico por imagem , Imagens de FantasmasRESUMO
In this work, we propose a free-breathing magnetic resonance fingerprinting (MRF) method that can be used to obtain B1+ -robust quantitative T1 maps of the abdomen in a clinically acceptable time. A three-dimensional MRF sequence with a radial stack-of-stars trajectory was implemented, and its k-space acquisition ordering was adjusted to improve motion-robustness in the context of MRF. The flip angle pattern was optimized using the Cramér-Rao Lower Bound, and the encoding efficiency of sequences with 300, 600, 900 and 1800 flip angles was evaluated. To validate the sequence, a movable multicompartment phantom was developed. Reference multiparametric maps were acquired under stationary conditions using a previously validated MRF method. Periodic motion of the phantom was used to investigate the motion-robustness of the proposed sequence. The best performing sequence length (600 flip angles) was used to image the abdomen during a free-breathing volunteer scan. When using a series of 600 or more flip angles, the estimated T1 values in the stationary phantom showed good agreement with the reference scan. Phantom experiments revealed that motion-related artifacts can appear in the quantitative maps and confirmed that a motion-robust k-space ordering is essential. The in vivo scan demonstrated that the proposed sequence can produce clean parameter maps while the subject breathes freely. Using this sequence, it is possible to generate B1+ -robust quantitative maps of T1 and B1+ next to M0 -weighted images under free-breathing conditions at a clinically usable resolution within 5 min.
Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração , Humanos , Movimento (Física) , Imagens de FantasmasRESUMO
PURPOSE: The goal of this work is to demonstrate a method for the simultaneous acquisition of proton multiparametric maps (T1 , T2 , and proton density) and sodium density images in 1 single scan. We hope that the development of such capabilities will help to ease the implementation of sodium MRI in clinical trials and provide more opportunities for researchers to investigate metabolism through sodium MRI. METHODS: We developed a sequence based on magnetic resonance fingerprinting (MRF), which contains interleaved proton (1 H) and sodium (23 Na) excitations followed by a simultaneous center-out radial readout for both nuclei. The receive chain of a 7T scanner was modified to enable simultaneous acquisition of 1 H and 23 Na signal. The obtained signal-to-noise ratio (SNR) was evaluated, and the accuracy of both proton T1 , T2 , and B1+ and sodium density maps were verified in phantoms. Finally, the method was demonstrated in 2 healthy subjects. RESULTS: The SNR obtained using the simultaneous measurement was almost identical to single-nucleus measurements (<1% change). Similarly, the proton T1 and T2 maps remained stable (normalized root mean square error in T1 ≈ 2.2%, in T2 ≈ 1.4%, and B1+ ≈ 5.4%), which indicates that the proposed sequence and hardware have no significant effects on the signal from either nucleus. In vivo measurements corroborated these results and demonstrated the feasibility of our method for in vivo application. CONCLUSIONS: With the proposed approach, we were able to simultaneously acquire sodium density images in addition to proton T1 , T2 , and B1+ maps as well as proton density images.
Assuntos
Prótons , Sódio , Encéfalo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagens de FantasmasRESUMO
PURPOSE: To study the effects of magnetization transfer (MT, in which a semi-solid spin pool interacts with the free pool), in the context of magnetic resonance fingerprinting (MRF). METHODS: Simulations and phantom experiments were performed to study the impact of MT on the MRF signal and its potential influence on T1 and T2 estimation. Subsequently, an MRF sequence implementing off-resonance MT pulses and a dictionary with an MT dimension, generated by incorporating a two-pool model, were used to estimate the fractional pool size in addition to the B1+ , T1 , and T2 values. The proposed method was evaluated in the human brain. RESULTS: Simulations and phantom experiments showed that an MRF signal obtained from a cross-linked bovine serum sample is influenced by MT. Using a dictionary based on an MT model, a better match between simulations and acquired MR signals can be obtained (NRMSE 1.3% vs. 4.7%). Adding off-resonance MT pulses can improve the differentiation of MT from T1 and T2 . In vivo results showed that MT affects the MRF signals from white matter (fractional pool-size ~16%) and gray matter (fractional pool-size ~10%). Furthermore, longer T1 (~1060 ms vs. ~860 ms) and T2 values (~47 ms vs. ~35 ms) can be observed in white matter if MT is accounted for. CONCLUSION: Our experiments demonstrated a potential influence of MT on the quantification of T1 and T2 with MRF. A model that encompasses MT effects can improve the accuracy of estimated relaxation parameters and allows quantification of the fractional pool size.
Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Animais , Encéfalo/diagnóstico por imagem , Bovinos , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
Diffusion tractography is routinely used to study white matter architecture and brain connectivity in vivo. A key step for successful tractography of neuronal tracts is the correct identification of tract directions in each voxel. Here we propose a fingerprinting-based methodology to identify these fiber directions in Orientation Distribution Functions, dubbed ODF-Fingerprinting (ODF-FP). In ODF-FP, fiber configurations are selected based on the similarity between measured ODFs and elements in a pre-computed library. In noisy ODFs, the library matching algorithm penalizes the more complex fiber configurations. ODF simulations and analysis of bootstrapped partial and whole-brain in vivo datasets show that the ODF-FP approach improves the detection of fiber pairs with small crossing angles while maintaining fiber direction precision, which leads to better tractography results. Rather than focusing on the ODF maxima, the ODF-FP approach uses the whole ODF shape to infer fiber directions to improve the detection of fiber bundles with small crossing angle. The resulting fiber directions aid tractography algorithms in accurately displaying neuronal tracts and calculating brain connectivity.
Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Substância Branca/diagnóstico por imagem , Algoritmos , Encéfalo/anatomia & histologia , Simulação por Computador , Humanos , Vias Neurais/anatomia & histologia , Vias Neurais/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Substância Branca/anatomia & histologiaRESUMO
PURPOSE: The optimization and analysis of spin ensemble trajectories in the hybrid state-a state in which the direction of the magnetization adiabatically follows the steady state while the magnitude remains in a transient state. METHODS: Numerical optimizations were performed to find spin ensemble trajectories that minimize the Cramér-Rao bound for T1 -encoding, T2 -encoding, and their weighted sum, respectively, followed by a comparison between the Cramér-Rao bounds obtained with our optimized spin-trajectories, Look-Locker sequences, and multi-spin-echo methods. Finally, we experimentally tested our optimized spin trajectories with in vivo scans of the human brain. RESULTS: After a nonrecurring inversion segment on the southern half of the Bloch sphere, all optimized spin trajectories pursue repetitive loops on the northern hemisphere in which the beginning of the first and the end of the last loop deviate from the others. The numerical results obtained in this work align well with intuitive insights gleaned directly from the governing equation. Our results suggest that hybrid-state sequences outperform traditional methods. Moreover, hybrid-state sequences that balance T1 - and T2 -encoding still result in near optimal signal-to-noise efficiency for each relaxation time. Thus, the second parameter can be encoded at virtually no extra cost. CONCLUSIONS: We provided new insights into the optimal encoding processes of spin relaxation times in order to guide the design of robust and efficient pulse sequences. We found that joint acquisitions of T1 and T2 in the hybrid state are substantially more efficient than sequential encoding techniques.
Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , HumanosRESUMO
BACKGROUND: Quantitative MRI can detect early changes in cartilage biochemical components, but its routine clinical implementation is challenging. PURPOSE: To introduce a novel technique to measure T1 and T2 along radial sections of the hip for accurate and reproducible multiparametric quantitative cartilage assessment in a clinically feasible scan time. STUDY TYPE: Reproducibility, technical validation. SUBJECTS/PHANTOM: A seven-compartment phantom and three healthy volunteers. FIELD STRENGTH/SEQUENCE: A novel MR pulse sequence that simultaneously measures proton density (PD), T1 , and T2 at 3 T was developed. Automatic positioning and semiautomatic cartilage segmentation were implemented to improve consistency and simplify workflow. ASSESSMENT: Intra- and interscanner variability of our technique was assessed over multiple scans on three different MR scanners. STATISTICAL TESTS: For each scan, the median of cartilage T1 and T2 over six radial slices was calculated. Restricted maximum likelihood estimation of variance components was used to estimate intrasubject variances reflecting variation between results from the two scans using the same scanner (intrascanner variance) and variation among results from the three scanners (interscanner variance). RESULTS: The estimation error for T1 and T2 with respect to reference standard measurements was less than 3% on average for the phantom. The average interscanner coefficient of variation was 1.5% (1.2-1.9%) and 0.9% (0.0-3.7%) for T1 and T2 , respectively, in the seven compartments of the phantom. Total scan time in vivo was 7:13 minutes to obtain PD, T1 , and T2 maps along six radial hip sections at 0.6 × 0.6 × 4.0 mm3 voxel resolution. Interscanner variability for the in vivo study was 1.99% and 5.46% for T1 and T2 , respectively. in vivo intrascanner variability was 1.15% for T1 and 3.24% for T2 . DATA CONCLUSION: Our method, which includes slice positioning, model-based parameter estimation, and cartilage segmentation, is highly reproducible. It could enable employing quantitative hip cartilage evaluation for longitudinal and multicenter studies. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:810-815.
Assuntos
Cartilagem Articular/anatomia & histologia , Articulação do Quadril/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
PURPOSE: To design a robust and patient friendly radiofrequency coil array (8-channel transmit and 16-channel receive) for cross-sectional body imaging at 7 T, and to improve our understanding of the combination of dipole and loop like elements for ultra high field strengths. METHODS: The hybrid coil array was optimized in eletromagnetic simulations. Considered array candidates were the dipole, loop and birdcage array. The winning design was constructed and the signal-to-noise (SNR) was compared to a close fitting array at 3 T. Transmit and receive properties for different body sizes were assessed, and multi-parametric maps were acquired with the Plug-and-Play MRF method. RESULTS: The winning design consists of a dipole array for transceive combined with a birdcage array for receive only. The central SNR improved by a factor of 3 as compared to a 3 T system with a local receive array. A transmit efficiency between 2.4 and 3.9 µT/kW, a specific absorption rate efficiency of 0.25 to 0.53 µT/W/kg, and a high SNR was achieved in the center for the targeted patient population. CONCLUSION: The constructed coil array is easy to handle, safe, and patient friendly, allowing further development of abdominal imaging at 7 T. Quantitative MRI in the abdomen is possible with Plug-and-Play MRF using the designed coil array. Magn Reson Med 80:822-832, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imagem Corporal Total/instrumentação , Abdome/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído , Imagem Corporal Total/métodosRESUMO
PURPOSE: Transmit arrays are essential tools for various RF shimming or parallel excitation techniques at 7T. Here we present an array design with triangular coils to improve diversity in the B1 profiles in the longitudinal (z) direction and allow for next-nearest neighbor decoupling. METHODS: Two cylindrical 8-channel arrays having the same length and diameter, 1 of triangular coils and the other of rectangular coils, were constructed and compared in phantom imaging experiments using measures of excitation distribution for a variety of RF shim settings and geometry factor maps for different accelerations on different planes. RESULTS: Coupling between elements was -20 dB or better for all triangular coil pairs, but worse than -12 dB for several of the rectangular coil pairs. Both coils could produce adequate shims on a central transverse plane, but the same shim produced worse results off center for the triangular coil array than for the rectangular coil array. Compared to the rectangular coil array, the maximum geometry factor for the triangular coil array was reduced by a factor of 13.1 when using a 2-fold acceleration in the z-direction. CONCLUSION: An array design with triangular coils provides effective decoupling mechanisms for nearest and next-nearest neighboring elements, as well as diversity in B1 profiles along the z-direction, although this also means that individual slices must be shimmed separately. This design is well suited for parallel transmit applications while also having high receive sensitivity.
Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Razão Sinal-RuídoRESUMO
PURPOSE: The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for magnetic resonance fingerprinting. METHODS: Based on a singular value decomposition of the signal evolution, magnetic resonance fingerprinting is formulated as a low rank (LR) inverse problem in which one image is reconstructed for each singular value under consideration. This LR approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the LR approximation improves the conditioning of the problem, which is further improved by extending the LR inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers. The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. RESULTS: The proposed LR alternating direction method of multipliers approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a LR approximation alone and to an alternating direction method of multipliers approach without a LR approximation. Incorporating sensitivity encoding allows for further artifact reduction. CONCLUSION: The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other magnetic resonance fingerprinting reconstruction approaches evaluated in this study. Magn Reson Med 79:83-96, 2018. © 2017 International Society for Magnetic Resonance in Medicine.