Med Phys ; 37(8): 4331-42, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20879593

RESUMO

PURPOSE: This work presents the experimental extraction of the overall perturbation factor PQ in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD). METHODS: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers. RESULTS: The authors found that the perturbation factors for the NACP-02 and Roos chambers increased substantially with depth, especially for low-energy electron beams. The experimental results were in good agreement with the results of Monte Carlo simulations reported by other investigators. The authors also found that using an effective point of measurement (EPOM) placed inside the air cavity reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. CONCLUSIONS: A PSD can be used to experimentally extract perturbation factors for ionization chambers. The dosimetry protocol recommendations indicating that the point of measurement be placed on the inside face of the front window appear to be incorrect for parallel-plate chambers and result in errors in the R50 of approximately 0.4 mm at 6 MeV, 1.0 mm at 12 MeV, and 1.2 mm at 18 MeV.


Assuntos
Plásticos/efeitos da radiação , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Contagem de Cintilação/instrumentação , Análise de Falha de Equipamento/instrumentação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Med Phys ; 46(11): 5195-5208, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31424563

RESUMO

PURPOSE: ICRU Report 90 on Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications (2014) has reaffirmed the recommended value of the mean energy required to create an ion pair in air, Wair , to be 33.97(12) eV. The report also indicates that this "constant" of radiation dosimetry is energy independent above 10 keV, since there is no theoretical or experimental evidence to the contrary. The goal of this investigation is to obtain additional experimental determinations of Wair in high energy beams and thus to verify the suggested energy independence. METHODS: Wair can be evaluated by combining ionometric and calorimetric measurements with a calculated ratio of the absorbed dose in the ion chamber air cavity and that of the calorimeter absorbing element. In this investigation, a graphite parallel plate chamber and a graphite calorimeter were used and the dose ratio was calculated using the EGSnrc Monte Carlo code. Measurements were made in electron beams from the NRC Vickers linear accelerator at two incident energies, 20 and 35 MeV. A range of average energies at the measurement point were obtained by inserting graphite plates in the primary beam. RESULTS: The average value of Wair obtained in this investigation is 33.85(18) eV which is consistent with the recommended value of 33.97(12) eV where the number in brackets represents the combined standard uncertainty of the value, referring to the corresponding last digits. The individual values of Wair do not show any statistically significant energy dependence. CONCLUSION: The overall combined uncertainty of 0.5% meets the original target of the investigation. A larger-scale investigation, involving more individual energy points and a wider range of electron energies is required to go further and, for example, comment on the Wair energy dependency question raised by Tessier et al. [Med. Phys. 2018;45:370-381].


Assuntos
Elétrons , Grafite , Radiometria/instrumentação , Método de Monte Carlo
3.
Med Phys ; 45(1): 370-381, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29131343

RESUMO

PURPOSE: The average energy expended by an energetic electron to create an ion pair in dry air, Wair , is a key quantity in radiation dosimetry. Although Wair is well established for electron energies up to about 3 MeV, there is limited data for higher energies. The measurements by Domen and Lamperti [Med. Phys. 3, 294-301 (1976)] using electron beams in the energy range from 15 to 50 MeV can, in principle, be used to deduce values for Wair , if the electron stopping power of graphite and air are known. A previous analysis of these data revealed an anomalous variation of 2% in Wair as a function of the electron energy. We use Monte Carlo simulation techniques to reanalyze the original data and obtain new estimates for Wair , and to investigate the source of the reported anomaly. METHODS: Domen and Lamperti (DL) reported the ratio of the response of a graphite calorimeter to that of a graphite ionization chamber for broad beams of electrons with energies between 15 and 50 MeV and at different depths in graphite (including depths well beyond the range of the primary electrons, i.e., in the bremsstrahlung photon regime). Using a detailed EGSnrc model of the DL apparatus, as well as up-to-date stopping powers, we compute the dose ratio between the ionization chamber cavity and the calorimeter core, for plane-parallel electron beams. This dose ratio, multiplied by the DL measured ratio, provides a direct estimate for Wair . RESULTS: Despite an improved analysis of the original work, the extracted values of Wair still exhibit an increase as the mean electron energy at the point of measurement decreases below about 15 MeV. This anomalous trend is dubious physically, and inconsistent with extensive data for Wair obtained at lower energies. A thorough sensitivity analysis indicates that this trend is unlikely to stem from errors in extrapolation and correction procedures, uncertainties in electron stopping powers, or bias in calorimetry or ionization chamber measurements. However, we find that results are quite sensitive to the intrinsic graphite mass thickness of the detectors and to the incident beam energy. CONCLUSIONS: The DL experiment provides data in an energy regime where the electron stopping power is insensitive to the mean excitation energy of graphite - an issue plaguing Wair experiments at lower energies. Unfortunately, state-of-the-art scrutiny of the original data cannot explain the anomalous trend in terms of perturbation effects or extrapolation bias. It can only be understood in terms of speculative offsets in graphite mass thickness or beam energy. Therefore higher accuracy measurements for electron energies above 15 MeV are recommended to further resolve the value of Wair .


Assuntos
Elétrons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Ar , Simulação por Computador , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/instrumentação
4.
Phys Med Biol ; 63(8): 085004, 2018 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-29488467

RESUMO

Two Fricke-based absorbed dose to water standards for HDR Ir-192 dosimetry, developed independently by the LCR in Brazil and the NRC in Canada have been compared. The agreement in the determination of the dose rate from a HDR Ir-192 source at 1 cm in a water phantom was found to be within the k = 1 combined measurement uncertainties of the two standards: D NRC/D LCR = 1.011, standard uncertainty = 2.2%. The dose-based standards also agreed within the uncertainties with the manufacturer's stated dose rate value, which is traceable to a national standard of air kerma. A number of possible influence quantities were investigated, including the specific method for producing the ferrous-sulphate Fricke solution, the geometry of the holder, and the Monte Carlo code used to determine correction factors. The comparison highlighted the lack of data on the determination of G(Fe3+) in this energy range and the possibilities for further development of the holders used to contain the Fricke solution. The comparison also confirmed the suitability of Fricke dosimetry for Ir-192 primary standard dose rate determinations at therapy dose levels.


Assuntos
Braquiterapia/métodos , Compostos Ferrosos , Radioisótopos de Irídio/uso terapêutico , Radiometria/normas , Soluções , Água , Brasil , Canadá , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Padrões de Referência , Incerteza
5.
Med Phys ; 44(10): 5433-5444, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28688120

RESUMO

PURPOSE: To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, kQ , for several ion chamber types. METHODS: Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator. Ion chamber measurements are made as a function of depth for cylindrical and plane-parallel ion chambers over a period of five years to investigate the stability of ion chamber response and for indirect calibration. Water calorimetry measurements are made in 18 MeV and 22 MeV beams. An insulated enclosure with fine temperature control is used to maintain a constant temperature (drifts less than 0.1 mK/min) of the calorimeter phantom at 4°C to minimize effects from convection. Two vessels of different designs are used with calibrated thermistor probes to measure radiation induced temperature rise. The vessels are filled with high-purity water and saturated with H2 or N2 gas to minimize the effect of radiochemical reactions on the measured temperature rise. A set of secondary standard ion chambers are calibrated directly against the calorimeter. Finally, several other ion chambers are calibrated in the NRC 60 Co reference field and then cross-calibrated against the secondary standard chambers in electron beams to realize kQ factors. RESULTS: The long-term stability of the cylindrical ion chambers in electron beams is better (always <0.15%) than plane-parallel chambers (0.2% to 0.4%). Calorimetry measurements made at 22 MeV with two different vessel geometries are consistent within 0.2% after correction for the vessel perturbation. Measurements of absorbed dose calibration coefficients for the same secondary standard chamber separated in time by 10 yr are within 0.2%. Drifts in linac output that would affect the transfer of the standard are mitigated to the 0.1% level by performing daily ion chamber normalization measurements. Calibration coefficients for secondary standard ion chambers can be achieved with uncertainties less than 0.4% (k = 1) in high-energy electron beams. The additional uncertainty in deriving calibration coefficients for well-behaved chambers indirectly against the secondary standard reference chambers is negligible. The kQ factors measured here differ by up to 1.3% compared to those in TG-51, an important change for reference dosimetry measurements. CONCLUSIONS: The measurements made here of kQ factors for eight plane-parallel and six cylindrical ion chambers will impact future updates of reference dosimetry protocols by providing some of the highest quality measurements of this crucial dosimetric parameter.


Assuntos
Calorimetria , Elétrons , Água , Calibragem , Controle de Qualidade , Radiometria , Temperatura , Incerteza
6.
Phys Med Biol ; 60(11): 4481-95, 2015 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-25988983

RESUMO

The aim of this project was to develop an absorbed dose to water primary standard for Ir-192 brachytherapy based on the Fricke dosimeter. To achieve this within the framework of the existing TG-43 protocol, a determination of the absorbed dose to water at the reference position, D(r0,θ0), was undertaken. Prior to this investigation, the radiation chemical yield of the ferric ions (G-value) at the Ir-192 equivalent photon energy (0.380 MeV) was established by interpolating between G-values obtained for Co-60 and 250 kV x-rays.An irradiation geometry was developed with a cylindrical holder to contain the Fricke solution and allow irradiations in a water phantom to be conducted using a standard Nucletron microSelectron V2 HDR Ir-192 afterloader. Once the geometry and holder were optimized, the dose obtained with the Fricke system was compared to the standard method used in North America, based on air-kerma strength.Initial investigations focused on reproducible positioning of the ring-shaped holder for the Fricke solution with respect to the Ir-192 source and obtaining an acceptable type A uncertainty in the optical density measurements required to yield the absorbed dose. Source positioning was found to be reproducible to better than 0.3 mm, and a careful cleaning and control procedure reduced the variation in optical density reading due to contamination of the Fricke solution by the PMMA holder. It was found that fewer than 10 irradiations were required to yield a type A standard uncertainty of less than 0.5%.Correction factors to take account of the non-water components of the geometry and the volume averaging effect of the Fricke solution volume were obtained from Monte Carlo calculations. A sensitivity analysis showed that the dependence on the input data used (e.g. interaction cross-sections) was small with a type B uncertainty for these corrections estimated to be 0.2%.The combined standard uncertainty in the determination of absorbed dose to water at the reference position for TG-43 (1 cm from the source on the transverse axis, in a water phantom) was estimated to be 0.8% with the dominant uncertainty coming from the determination of the G-value. A comparison with absorbed dose to water obtained using the product of air-kerma strength and the dose rate constant gave agreement within 1.5% for three different Ir-192 sources, which is within the combined standard uncertainties of the two methods.


Assuntos
Braquiterapia/métodos , Compostos Ferrosos/efeitos da radiação , Radioisótopos de Irídio/uso terapêutico , Radiometria/normas , Soluções/efeitos da radiação , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Água