Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Lett B ; 761: 281-286, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-28057978

RESUMO

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

2.
Appl Radiat Isot ; 210: 111364, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38843648

RESUMO

166Ho (T1/2≈ 26.8 h) is an emerging theragnostic radionuclide of interest in nuclear medicine due to its peculiar decay scheme, featuring high-energy ß- emission (≈ 1.8 MeV) coupled with the main gamma-ray emission (≈ 80.6 keV). Using the new 166Ho activity standard and the well-calibrated, high-energy resolution HPGe detector, both available at ENEA-INMRI, a new determination of several 166Ho gamma-ray emission intensities, Iγ, was performed with low uncertainty. The new Iγ values contributed to the Decay Data Evaluation Project.

3.
Appl Radiat Isot ; 66(6-7): 948-53, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18372184

RESUMO

A (64)Cu national primary standard, was developed by the National Institute for Ionising Radiation Metrology (INMRI) of the ENEA (ENEA-INMRI) using the CIEMAT/NIST method of 4pibeta liquid scintillation spectrometry with (3)H-standard efficiency tracing. Relatively short (64)Cu half-life is required for the work to be performed at the production site. It was produced at the Scanditronix MC40 Cyclotron of the Joint Research Centre (JRC) of the European Commission (Ispra, Italy) through the (64)Zn(d,2p) (64)Cu reaction. Significant efforts were made to identify and quantify the impurities of (61)Cu and (65)Zn in the mother solution, which were activated through the (64)Zn(d,alphan) (61)Cu and (64)Zn(d,p) (65)Zn reactions, respectively. To this purpose, a new procedure for the determination of pure beta-emitter impurities by the CIEMAT/NIST method has been applied. A transfer standard portable well-type ionisation chamber was also calibrated with minimum uncertainty.

4.
Appl Radiat Isot ; 134: 370-375, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28821372

RESUMO

In this paper, the application of the efficiency transfer method to the evaluation of the surface beta contamination is described. Using efficiency transfer factors, the reference calibration factor of contamination monitors is corrected, to obtain the calibration factor for an actual contamination source. The experimental part of the paper illustrates the applicability of the method to the direct measurement of the surface beta contamination.

5.
Appl Radiat Isot ; 134: 105-107, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29066213

RESUMO

A severe supply crisis of 99Mo, precursor of 99mTc a diagnostic radionuclide largely used in Nuclear Medicine, occurred in 2008-2009 due to repeated shut-down of the two main (aged) fission reactors. An alternative route for producing 99Mo by 100Mo(n,2n)99Mo reaction was investigated at ENEA. The experiment, designed according to Monte Carlo simulations performed with the Fluka code, produced 99Mo by irradiating a natural Molybdenum powdered target with 14MeV neutrons produced at the Frascati Neutron Generator. The 99Mo specific activity was measured at metrological level by γ-ray spectrometry.

6.
Radiat Prot Dosimetry ; 180(1-4): 102-108, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29040768

RESUMO

The design and operation of ITER experimental fusion reactor requires the development of neutron measurement techniques and numerical tools to derive the fusion power and the radiation field in the device and in the surrounding areas. Nuclear analyses provide essential input to the conceptual design, optimisation, engineering and safety case in ITER and power plant studies. The required radiation transport calculations are extremely challenging because of the large physical extent of the reactor plant, the complexity of the geometry, and the combination of deep penetration and streaming paths. This article reports the experimental activities which are carried-out at JET to validate the neutronics measurements methods and numerical tools used in ITER and power plant design. A new deuterium-tritium campaign is proposed in 2019 at JET: the unique 14 MeV neutron yields produced will be exploited as much as possible to validate measurement techniques, codes, procedures and data currently used in ITER design thus reducing the related uncertainties and the associated risks in the machine operation.


Assuntos
Deutério/análise , Nêutrons , Reatores Nucleares/instrumentação , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/instrumentação , Trítio/análise , Doses de Radiação
7.
Appl Radiat Isot ; 65(1): 120-5, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16996744

RESUMO

Following the approach of the National Primary Laboratory of the UK (NPL) for the calibration of radionuclide calibrators, but using a commercially available instrument with no data available in the literature, the radionuclide calibrator response was investigated as a function of different measurement geometries at the "Regina Elena" National Cancer Institute (IRE) in Rome. Working with Italian National Metrology Institute for ionising radiation quantities (ENEA-INMRI), specific calibration factors with traceability to national primary standards were determined for different types of glass vials, solid capsules and plastic syringes, investigating three radionuclides with different energy spectra (Tc-99m, In-111, I-131). For each kind of syringe, calibration correction factors for different filling volumes were calculated. For Tc-99m and I-131 the difference between measured and true activity was in the range 2-7%, depending on measurement geometry. For In-111 a large percentage deviation from the true activity value was found in each geometry considered, reaching 35%. The magnitude of this difference is particularly dependent on the energies of the emitted photons.


Assuntos
Guias como Assunto , Radioisótopos/análise , Radioisótopos/normas , Radiometria/instrumentação , Radiometria/normas , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/normas , Calibragem , União Europeia , Doses de Radiação , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Appl Radiat Isot ; 129: 135-141, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28850827

RESUMO

This paper describes a new approach in evaluating the surface beta contamination using the direct method of measurement. It makes use of previous results obtained in numerical modeling of electron transport in planar geometry and is mainly based on the estimation of the efficiency of contamination sources for beta radiation and its standard uncertainty using the available information concerning the component materials of the sources and their main parameters. Experimental results illustrate the appropriateness of the new approach for surface beta contamination measurements.

9.
Appl Radiat Isot ; 126: 256-262, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28258951

RESUMO

The determination of characteristic limits in the measurement of radioactive materials is an important aspect of low-level measurements and the underlying principles are well understood by scientists working on such measurements. ISO 11929:2010 provides a rigorous basis for the systematic calculation of detection limits, but may be difficult to interpret for the routine user. This paper attempts to simplify some of the more arcane aspects of this standard.

10.
Appl Radiat Isot ; 130: 252-259, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29040881

RESUMO

This paper addresses the measurement facilities for pre-selection of waste materials prior to measurement for repository acceptance or possible free release (segregation measurement system); and free release (free release measurement system), based on a single standardized concept characterized by unique, patented lead-free shielding. The key objective is to improve the throughput, accuracy, reliability, modularity and mobility of segregation and free-release measurement. This will result in a more reliable decision-making with regard to the safe release and disposal of radioactive wastes into the environment and, resulting in positive economic outcomes. The research was carried out within "Metrology for Decommissioning Nuclear Facilities" (MetroDecom) project.

11.
Appl Radiat Isot ; 126: 138-145, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28187932

RESUMO

Characterization and calibration measurements were carried out at the National Institute of Ionizing Radiation Metrology of ENEA on the TAp WAter RAdioactivity (TAWARA) Real Time Monitor system recently developed for real time monitoring of radioactive contamination in water processed at water treatment facilities. Reference radiations and radionuclides were chosen in order to reflect energy ranges and radiation types of the major water radioactive contaminants possibly arising from environmental, industrial or terroristic origin. The following instrument parameters were tested: sensitivity, selectivity, background, short/long term stability, linearity with respect to activity.


Assuntos
Sistemas Computacionais , Monitoramento de Radiação/instrumentação , Poluentes Radioativos da Água/análise , Purificação da Água , Partículas alfa , Partículas beta , Calibragem , Sistemas Computacionais/estatística & dados numéricos , Desenho de Equipamento , Humanos , Monitoramento de Radiação/normas , Monitoramento de Radiação/estatística & dados numéricos , Radioisótopos/análise , Padrões de Referência , Espectrometria gama , Poluentes Radioativos da Água/normas , Contaminação Radioativa da Água/análise , Purificação da Água/normas
12.
Appl Radiat Isot ; 126: 279-284, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28233595

RESUMO

Reliable measurement of Naturally Occurring Radioactive Materials is of significance in order to comply with environmental regulations and for radiological protection purposes. This paper discusses the standardisation of three reference materials, namely sand, tuff and TiO2 to serve as quality control materials for traceability, method validation and instrument calibration. The sample preparation, material characterization via γ, α and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and the assignment of values for both the 4n (Thorium) and 4n+2 (Uranium) decay series are described.

13.
Appl Radiat Isot ; 64(10-11): 1229-33, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16549350

RESUMO

The sum-peak counting method was applied for 125I absolute activity measurement. Count rate-dependent corrections for random summing and dead time effects were experimentally determined at different count rates and in several experimental conditions. Two NaI(Tl) crystals of different volumes were used. They were connected to pulse recording systems with different characteristics, with or without pile-up rejection live-time corrector circuits (PUR/LTC). A theoretical model was proposed to explain the different behaviours found experimentally. It is shown that count rate-dependent effects are drastically reduced by the use of PUR/LTC.


Assuntos
Algoritmos , Artefatos , Radiometria/métodos , Radiometria/normas , Simulação por Computador , República Tcheca , Interpretação Estatística de Dados , Guias como Assunto , Itália , Modelos Químicos , Modelos Estatísticos , Doses de Radiação , Distribuição Aleatória , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Appl Radiat Isot ; 107: 206-213, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26524407

RESUMO

This paper is concerned with the modeling of the transmission of beta rays through thin foils in planar geometry based on the plane source concept, using Monte Carlo simulation of electron transport and least squares fitting. Applications of modeling results for calculating the efficiency of large-area beta sources, transmission coefficient of beta rays through thin foils and the beta detection efficiency of large-area detectors used in surface contamination measurements are also presented.

15.
Appl Radiat Isot ; 109: 358-362, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26701656

RESUMO

A novel method has been developed for the activity measurement of large-area beta reference sources. It makes use of two emission rate measurements and is based on the weak dependence between the source activity and the activity distribution for a given value of transmission coefficient. The method was checked experimentally by measuring the activity of two ((60)Co and (137)Cs) large-area reference sources constructed from anodized aluminum foils. Measurement results were compared with the activity values measured by gamma spectrometry. For each source, they agree within one standard uncertainty and also agree within the same limits with the certified values of the source activity.


Assuntos
Algoritmos , Partículas beta , Radioisótopos/análise , Radioisótopos/normas , Espectrometria gama/métodos , Espectrometria gama/normas , Internacionalidade , Análise Numérica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Phys Med ; 32(12): 1745-1752, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27692753

RESUMO

Peptide receptor therapy with 177Lu-labelled somatostatin analogues is a promising tool in the management of patients with inoperable or metastasized neuroendocrine tumours. The aim of this work was to perform accurate activity quantification of 177Lu in complex anthropomorphic geometry using advanced correction algorithms. Acquisitions were performed on the higher 177Lu photopeak (208keV) using a Philips IRIX gamma camera provided with medium-energy collimators. System calibration was performed using a 16mL Jaszczak sphere surrounded by non-radioactive water. Attenuation correction was performed using µ-maps derived from CT data, while scatter and septal penetration corrections were performed using the transmission-dependent convolution-subtraction method. SPECT acquisitions were finally corrected for dead time and partial volume effects. Image analysis was performed using the commercial QSPECT software. The quantitative SPECT approach was validated on an anthropomorphic phantom provided with a home-made insert simulating a hepatic lesion. Quantitative accuracy was studied using three tumour-to-background activity concentration ratios (6:1, 9:1, 14:1). For all acquisitions, the recovered total activity was within 12% of the calibrated activity both in the background region and in the tumour. Using a 6:1 tumour-to-background ratio the recovered total activity was within 2% in the tumour and within 5% in the background. Partial volume effects, if not properly accounted for, can lead to significant activity underestimations in clinical conditions. In conclusion, accurate activity quantification of 177Lu can be obtained if activity measurements are performed with equipment traceable to primary standards, advanced correction algorithms are used and acquisitions are performed at the 208keV photopeak using medium-energy collimators.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Lutécio , Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Técnica de Subtração
17.
Appl Radiat Isot ; 112: 156-64, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27064195

RESUMO

Over the last years (177)Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, (177)Lu emits low energy gamma radiation of 113keV and 208keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives. The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with (177)Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with (177)LuCl3. Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208keV, with agreement within 5% for all geometries. The use of a Jaszczak 16mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in anthropomorphic geometry within about 10% (range -11.6% to +7.3%) for acquisitions at the 208keV photopeak. As a general rule, scatter and attenuation play a much larger role at 113keV compared to 208keV and are likely to hinder an accurate absolute quantification. Acquisitions of only the (177)Lu main photopeak (208keV) are therefore recommended in clinical practice. Preliminary results suggest that the gamma camera calibration factor can be assessed with a standard uncertainty below (or of the order of) 3% if activity is determined with equipment traceable to primary standards, accurate volume measurements are made, and an appropriate chemical carrier is used to allow a homogeneous and stable solution to be used during the measurements.


Assuntos
Câmaras gama , Lutécio , Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Calibragem , Câmaras gama/estatística & dados numéricos , Humanos , Interpretação de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
18.
Appl Radiat Isot ; 109: 17-23, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26682894

RESUMO

In 2014, the first three comparisons of activity measurements of (18)F were carried out at the VNIIM, NPL and the ENEA-INMRI using the BIPM's Transfer Instrument of the International Reference System. The transfer instrument and the NMIs primary measurement methods are briefly described. The degrees of equivalence with the key comparison reference value defined in the frame of the corresponding SIR comparison have been evaluated. World-wide consistency of activity measurements of (18)F is demonstrated.


Assuntos
Radioisótopos de Flúor/análise , Radioisótopos de Flúor/normas , Laboratórios/normas , Medicina Nuclear/normas , Radiometria/normas , Internacionalidade , Doses de Radiação , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Sci Total Environ ; 69: 29-41, 1988 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-3363329

RESUMO

A national intercomparison was organized by ENEA for activity measurements of 90Sr and 137Cs in spiked solutions of milk. The participants in the intercomparison were the laboratories belonging to the Italian network for control of radioactivity in the environment. The purpose of these measurements was to check the reliability of measurement procedures and experimental means as routinely used by each participant. This first intercomparison showed appreciable discrepancies among the participants and this was due both to improper procedures and non correct calibrated spectrometers. Soon after a second intercomparison was carried out to check to what extent the previous results were reproducible among the various participants. Methods and results are discussed.


Assuntos
Radioisótopos de Césio/análise , Leite/análise , Radiometria/métodos , Radioisótopos de Estrôncio/análise , Animais , Bovinos , Itália , Laboratórios , Valores de Referência
20.
Sci Total Environ ; 130-131: 473-83, 1993 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-8469959

RESUMO

A programme for the Quality Assurance of the Italian network for surveillance of radioactivity in foodstuff and environmental samples was started by the ENEA in 1983. The main purpose of this programme is to establish uniform levels of accuracy and reproducibility in measurement procedures routinely used by the laboratories belonging to the network. This paper describes the technical aspects relevant to the calibration and intercomparison campaigns carried out, in Italy, in the period 1986-1989. The relevant measurements include gamma spectrometry and beta-ray counting in liquid aqueous samples.


Assuntos
Contaminação Radioativa de Alimentos/análise , Vigilância da População , Contagem de Cintilação/normas , Espectrometria gama/normas , Calibragem/normas , Humanos , Itália , Laboratórios/normas , Controle de Qualidade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA