Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(25): 256903, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37418723

RESUMO

Spin-lattice relaxation within the nitrogen-vacancy (NV) center's electronic ground-state spin triplet limits its coherence times, and thereby impacts its performance in quantum applications. We report measurements of the relaxation rates on the NV center's |m_{s}=0⟩↔|m_{s}=±1⟩ and |m_{s}=-1⟩↔|m_{s}=+1⟩ transitions as a function of temperature from 9 to 474 K in high-purity samples. We show that the temperature dependencies of the rates are reproduced by an ab initio theory of Raman scattering due to second-order spin-phonon interactions, and we discuss the applicability of the theory to other spin systems. Using a novel analytical model based on these results, we suggest that the high-temperature behavior of NV spin-lattice relaxation is dominated by interactions with two groups of quasilocalized phonons centered at 68.2(17) and 167(12) meV.


Assuntos
Diamante , Nitrogênio , Temperatura
2.
Nat Nanotechnol ; 11(3): 247-52, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26571007

RESUMO

Quantum sensors based on single solid-state spins promise a unique combination of sensitivity and spatial resolution. The key challenge in sensing is to achieve minimum estimation uncertainty within a given time and with high dynamic range. Adaptive strategies have been proposed to achieve optimal performance, but their implementation in solid-state systems has been hindered by the demanding experimental requirements. Here, we realize adaptive d.c. sensing by combining single-shot readout of an electron spin in diamond with fast feedback. By adapting the spin readout basis in real time based on previous outcomes, we demonstrate a sensitivity in Ramsey interferometry surpassing the standard measurement limit. Furthermore, we find by simulations and experiments that adaptive protocols offer a distinctive advantage over the best known non-adaptive protocols when overhead and limited estimation time are taken into account. Using an optimized adaptive protocol we achieve a magnetic field sensitivity of 6.1 ± 1.7 nT Hz(-1/2) over a wide range of 1.78 mT. These results open up a new class of experiments for solid-state sensors in which real-time knowledge of the measurement history is exploited to obtain optimal performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA