Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nanotechnology ; 27(25): 254001, 2016 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-27242024

RESUMO

We report high photovoltaic performance of a novel donor-acceptor (D-A) conjugated polymer poly[2,6[4,8-bis(2-ethyl-hexyl)benzo[1,2-b;4,5-b']dithiophene-co-2,5-thiophene-co-4,7[5,6-bis-octyloxy-benzo[1,2,5]thiadiazole]-co-2,5-thiophene] (PBDTTBTZT) in bulk heterojunctions with [6,6]-phenyl-C71-butyric acid methyl ester (PC70BM). A power conversion efficiency (PCE) of more than 7% is obtained for optimized charge-extracting electrodes. Upon application of thermal stress via annealing, a superior thermal stability is demonstrated as compared to poly[N-9″-hepta-decanyl-2,7-carbazole-alt-5,5-(4',7'-di-2-thienyl-2',1',3'-benzothiadiazole)] (PCDTBT).

2.
Science ; 238(4826): 512-4, 1987 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-17809615

RESUMO

The nuclear reactor from the Soviet radar reconnaissance satellite, Cosmos-1402, reentered the earth's atmosphere on 7 February 1983 and disintegrated over the South Atlantic Ocean. The reactor was powered by approximately 50 kilograms of uranium-235 ((235)U). In an effort to determine the fate of the reactor core, a series of aerosol samples were collected at altitudes between 27 and 36 kilometers in the Northern Hemisphere approximately 1.1 years later by high-altitude balloons. At an altitude of 36 kilometers a 53 +/- 20 percent excess in the (235)U concentration was measured. The total excess of (235)U in the stratosphere was calculated to be 44 +/- 15 kilograms.

3.
J Res Natl Inst Stand Technol ; 103(6): 625-632, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-28009370

RESUMO

We describe the use of Bayesian inference to include prior information about the value of the measurand in the calculation of measurement uncertainty. Typical examples show this can, in effect, reduce the expanded uncertainty by up to 85 %. The application of the Bayesian approach to proving workpiece conformance to specification (as given by international standard ISO 14253-1) is presented and a procedure for increasing the conformance zone by modifying the expanded uncertainty guard bands is discussed.

4.
J Res Natl Inst Stand Technol ; 106(2): 371-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-27500027

RESUMO

This paper presents a detailed discussion of the technical aspects of the calibration process with emphasis on the definition of the measurand, the conditions under which the calibration results are valid, and the subsequent use of the calibration results in measurement uncertainty statements. The concepts of measurement uncertainty, error, systematic error, and reproducibility are also addressed as they pertain to the calibration process.

5.
J Res Natl Inst Stand Technol ; 105(4): 571-9, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-27551625

RESUMO

The problem of determining a consensus value and its uncertainty from the results of multiple methods or laboratories is discussed. Desirable criteria of a solution are presented. A solution motivated by the ISO Guide to the Expression of Uncertainty in Measurement (ISO GUM) is introduced and applied in a detailed worked example. A Bayesian hierarchical model motivated by the proposed solution is presented and compared to the solution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA