Int J Audiol ; : 1-7, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602203

RESUMO

OBJECTIVE: To objectively measure audibility in patients wearing bone conduction devices (BCDs) with a new approach using a skin microphone at the patient's forehead. DESIGN: The skin microphone was attached by a softband and shielded by an earmuff. This set-up was confirmed not to be influenced by neither noise floor nor sound bypassing the BCD. Sound field warble tones were used for measuring aided hearing thresholds and maximum power output (MPO) whereas an international speech test signal (ISTS) was presented at different speech levels. STUDY SAMPLE: 29 patients were tested (two were bilateral), 19 used percutaneous, eight used active transcutaneous and two used passive transcutaneous devices. RESULTS: The skin microphone responses at ISTS levels, hearing threshold and MPO, could be obtained in all patients. Two patients with poor audibility are highlighted in this article as examples. After adjusting the gain of the BCD, they were retested with the skin microphone (for verification) and with speech-in-noise tests (for validation). Both tests confirmed an improved audibility after the adjustments. CONCLUSION: In summary, the proposed measurement of audibility of speech using a skin microphone is a promising method that can be used in a clinical setting for all types of BCDs.

2.
Int J Audiol ; 62(4): 357-361, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35238713

RESUMO

OBJECTIVE: Objective measurement of audibility (verification) using bone conduction devices (BCDs) has long remained an elusive problem for BCDs. For air conduction hearing aids there are well-defined and often used objective methods, and the aim of this study is to develop an objective method for BCDs. DESIGN: In a novel setup for audibility measurements of bone-anchored hearing aid (BAHA) attached via a soft band, we used a skin microphone (SM) on the forehead measuring in-situ sound field thresholds, maximum power output (MPO) and international speech test signal (ISTS) responses. STUDY SAMPLE: Five normal-hearing persons. RESULT: Using the electrical output of SM it was possible to objectively measure the audibility of a skin drive BCD, presented as an eSPL-o-gram showing thresholds, MPO and ISTS response. Normalised eSPL-o-gram was verified against corresponding FL-o-grams (corresponding force levels from skull simulator and artificial mastoid (AM)). CONCLUSION: The proposed method with the SM can be used for objective measurements of the audibility of any BCDs based on thresholds, MPO and speech response allowing for direct comparisons of hearing and BCD output on the same graph using an eSPL-o-gram. After normalisation to hearing thresholds, the audibility can be assessed without the need for complicated calibration procedures.


Assuntos
Auxiliares de Audição , Humanos , Condução Óssea/fisiologia , Projetos Piloto , Audição , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/reabilitação
3.
Crit Care ; 26(1): 142, 2022 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-35585614

RESUMO

BACKGROUND: Critically ill COVID-19 patients may develop acute respiratory distress syndrome and the need for respiratory support, including mechanical ventilation in the intensive care unit. Previous observational studies have suggested early tracheotomy to be advantageous. The aim of this parallel, multicentre, single-blinded, randomized controlled trial was to evaluate the optimal timing of tracheotomy. METHODS: SARS-CoV-2-infected patients within the Region Västra Götaland of Sweden who needed intubation and mechanical respiratory support were included and randomly assigned to early tracheotomy (≤ 7 days after intubation) or late tracheotomy (≥ 10 days after intubation). The primary objective was to compare the total number of mechanical ventilation days between the groups. RESULTS: One hundred fifty patients (mean age 65 years, 79% males) were included. Seventy-two patients were assigned to early tracheotomy, and 78 were assigned to late tracheotomy. One hundred two patients (68%) underwent tracheotomy of whom sixty-one underwent tracheotomy according to the protocol. The overall median number of days in mechanical ventilation was 18 (IQR 9; 28), but no significant difference was found between the two treatment regimens in the intention-to-treat analysis (between-group difference: - 1.5 days (95% CI - 5.7 to 2.8); p = 0.5). A significantly reduced number of mechanical ventilation days was found in the early tracheotomy group during the per-protocol analysis (between-group difference: - 8.0 days (95% CI - 13.8 to - 2.27); p = 0.0064). The overall correlation between the timing of tracheotomy and days of mechanical ventilation was significant (Spearman's correlation: 0.39, p < 0.0001). The total death rate during intensive care was 32.7%, but no significant differences were found between the groups regarding survival, complications or adverse events. CONCLUSIONS: The potential superiority of early tracheotomy when compared to late tracheotomy in critically ill patients with COVID-19 was not confirmed by the present randomized controlled trial but is a strategy that should be considered in selected cases where the need for MV for more than 14 days cannot be ruled out. Trial registration NCT04412356 , registered 05/24/2020.


Assuntos
COVID-19 , SARS-CoV-2 , Idoso , Estado Terminal/epidemiologia , Estado Terminal/terapia , Feminino , Humanos , Masculino , Respiração Artificial/métodos , Traqueotomia/métodos , Resultado do Tratamento
4.
Audiol Neurootol ; 25(5): 263-275, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32268333

RESUMO

BACKGROUND: The bone conduction implant (BCI) is an active transcutaneous bone conduction device where the transducer has direct contact to the bone, and the skin is intact. Sixteen patients have been implanted with the BCI with a planned follow-up of 5 years. This study reports on hearing, quality of life, and objective measures up to 36 months of follow-up in 10 patients. METHOD: Repeated measures were performed at fitting and after 1, 3, 6, 12, and 36 months including sound field warble tone thresholds, speech recognition thresholds in quiet, speech recognition score in noise, and speech-to-noise thresholds for 50% correct words with adaptive noise. Three quality of life questionnaires were used to capture the benefit from the intervention, appreciation from different listening situations, and the ability to interact with other people when using the BCI. The results were compared to the unaided situation and a Ponto Pro Power on a soft band. The implant functionality was measured by nasal sound pressure, and the retention force from the audio processor against the skin was measured using a specially designed audio processor and a force gauge. RESULTS: Audiometry and quality of life questionnaires using the BCI or the Ponto Pro Power on a soft band were significantly improved compared to the unaided situation and the results were statistically supported. There was generally no significant difference between the two devices. The nasal sound pressure remained stable over the study period and the force on the skin from the audio processor was 0.71 ± 0.22 N (mean ± 1 SD). CONCLUSION: The BCI improves the hearing ability for tones and speech perception in quiet and in noise for the indicated patients. The results are stable over a 3-year period, and the patients subjectively report a beneficial experience from using the BCI. The transducer performance and contact to the bone is unchanged over time, and the skin area under the audio processor remains without complications during the 3-year follow-up.


Assuntos
Condução Óssea , Auxiliares de Audição , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Audição/fisiologia , Qualidade de Vida , Percepção da Fala/fisiologia , Adolescente , Adulto , Idoso , Audiometria , Feminino , Seguimentos , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
5.
Int J Audiol ; 58(12): 945-955, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31710259

RESUMO

Objective: The objective of this study is to evaluate its safety and effectiveness of the bone conduction implant (BCI) having an implanted transducer and to review similar bone conduction devices.Design: This is a consecutive prospective case series study where the patients were evaluated after 1, 3, 6 and 12 months. Outcome measures were focussed on intraoperative and postoperative safety, the effectiveness of the device in terms of audiological performance and patient's experience.Study sample: Sixteen patients with average age of 40.2 (range 18-74) years have been included. Thirteen patients were operated in Gothenburg and three in Stockholm.Results: It was found that the procedure for installing the BCI is safe and the transmission condition was stable over the follow-up time. No serious adverse events or severe adverse device effects occurred. The hearing sensitivity, speech in noise and the self-assessment as compared with the unaided condition improved significantly with the BCI. These patients also performed similar or better than with a conventional bone conduction reference device on a softband.Conclusions: In summary, it was found that the BCI can provide a safe and effective hearing rehabilitation alternative for patients with mild-to-moderate conductive or mixed hearing impairments.


Assuntos
Condução Óssea , Auxiliares de Audição , Perda Auditiva Condutiva/cirurgia , Implantação de Prótese/métodos , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Perda Auditiva Condutiva/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
6.
Int J Audiol ; 54(6): 408-16, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25705995

RESUMO

OBJECTIVE: To investigate audiological and quality of life outcomes for a new active transcutaneous device, called the bone conduction implant (BCI), where the transducer is implanted under intact skin. DESIGN: A clinical study with sound field audiometry and questionnaires at six-month follow-up was conducted with a bone-anchored hearing aid on a softband as reference device. STUDY SAMPLE: Six patients (age 18-67 years) with mild-to-moderate conductive or mixed hearing loss. RESULTS: The surgical procedure was found uneventful with no adverse events. The first hypothesis that BCI had a statistically significant improvement over the unaided condition was proven by a pure-tone-average improvement of 31.0 dB, a speech recognition threshold improvement in quiet (27.0 dB), and a speech recognition score improvement in noise (51.2 %). At speech levels, the signal-to-noise ratio threshold for BCI was - 5.5 dB. All BCI results were better than, or similar to the reference device results, and the APHAB and GBI questionnaires scores showed statistically significant improvements versus the unaided situation, supporting the second and third hypotheses. CONCLUSIONS: The BCI provides significant hearing rehabilitation for patients with mild-to-moderate conductive or mixed hearing impairments, and can be easily and safely implanted under intact skin.


Assuntos
Condução Óssea/fisiologia , Correção de Deficiência Auditiva/instrumentação , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Próteses Neurais , Qualidade de Vida , Estimulação Acústica/instrumentação , Estimulação Acústica/métodos , Adolescente , Adulto , Idoso , Audiometria de Tons Puros , Limiar Auditivo , Feminino , Perda Auditiva Condutiva/fisiopatologia , Perda Auditiva Condutiva/psicologia , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Razão Sinal-Ruído , Percepção da Fala/fisiologia , Resultado do Tratamento , Adulto Jovem
7.
Int J Audiol ; 54(10): 736-44, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26068536

RESUMO

OBJECTIVE: The objective of this study is to describe the technical design and verify the technical performance of a new bone conduction implant (BCI) system. DESIGN: The BCI consists of an external audio processor and an implanted unit called the bridging bone conductor. These two units use an inductive link to communicate with each other through the intact skin in order to drive an implanted transducer. STUDY SAMPLE: In this study, the design of the full BCI system has been described and verified on a skull simulator and on real patients. RESULTS: It was found that the maximum output force (peak 107 dB re 1 µN) of the BCI is robust for skin thickness range of 2-8 mm and that the total harmonic distortion is below 8% in the speech frequency range for 70 dB input sound pressure level. The current consumption is 7.5 mA, which corresponds to 5-7 days use with a single battery. CONCLUSIONS: This study shows that the BCI is a robust design that gives a sufficiently high output and an excellent sound quality for the hearing rehabilitation of indicated patients.


Assuntos
Condução Óssea , Auxiliares de Audição , Perda Auditiva Neurossensorial/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Implantação de Prótese , Percepção da Fala , Estimulação Acústica , Audiometria da Fala , Limiar Auditivo , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Perda Auditiva Neurossensorial/psicologia , Humanos , Teste de Materiais , Modelos Anatômicos , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Processamento de Sinais Assistido por Computador , Inteligibilidade da Fala
8.
Int J Audiol ; 53(6): 360-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24588466

RESUMO

OBJECTIVE: Bone conduction (BC) stimulation closer to the cochlea has previously been shown to give higher cochlear promontory acceleration measured by laser Doppler vibrometry (LDV). This study is investigating whether stimulation closer to the cochlea also gives improved hearing sensitivity. Furthermore, the study compares shifts in hearing sensitivity (BC thresholds) and ear-canal sound pressure (ECSP). DESIGN: BC hearing thresholds and ECSP have been measured for stimulation at two positions: the existing bone-anchored hearing aid (BAHA) position, and a new bone conduction implant (BCI) position that is located closer to the cochlea. STUDY SAMPLE: The measurements were made on 20 normal-hearing subjects. RESULTS: Depending on frequency, the ipsilateral hearing threshold was 3-14 dB better, and the ipsilateral ECSP was 2-12 dB higher for the BCI than for the BAHA position, with no significant differences between threshold and ECSP shifts at group level for most frequencies, and individually only for some subjects. CONCLUSIONS: It was found that both the objective ECSP and the subjective hearing threshold measurements gave similar improvement as previous LDV measurements for stimulation closer to the cochlea. One exception was that the LDV measurements did not show the improved sensitivity for frequencies below 500 Hz found here.


Assuntos
Limiar Auditivo , Condução Óssea , Cóclea/fisiologia , Testes Auditivos/métodos , Estimulação Acústica , Adulto , Audiometria de Tons Puros , Cóclea/anatomia & histologia , Feminino , Testes Auditivos/instrumentação , Humanos , Masculino , Valor Preditivo dos Testes , Pressão , Valores de Referência , Transdutores de Pressão , Adulto Jovem
9.
Hear Res ; 421: 108503, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35490057

RESUMO

Active transcutaneous bone conduction devices are a type of bone conduction device developed to keep the skin intact and provide direct bone conduction stimulation. The Bone Conduction Implant (BCI) is such a device and has been implanted in 16 patients. The objective of this paper is to give a broad overview of the BCI development to the final results of 13 patients at 5-year follow-up. Follow-up of these patients included audiological performance investigations, questionnaires, as well as safety evaluation and objective functionality testing of the device. Among those audiological measurements were sound field warble tone thresholds, speech recognition threshold (SRT), speech recognition score (SRS) and signal to noise ratio threshold (SNR-threshold). The accumulated implant time for all 16 patients was 113 years in February 2022. During this time, no serious adverse events have occurred. The functional improvement for the 13 patients reported in this paper was on average 29.5 dB (average over 0.5, 1, 2 and 4 kHz), while the corresponding effective gain was -12.4 dB. The SRT improvement was 24.5 dB and the SRS improvement was 38.1%, while the aided SNR-threshold was on average -6.4 dB. It was found that the BCI can give effective and safe hearing rehabilitation for patients with conductive and mild-to-moderate mixed hearing loss.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista , Perda Auditiva , Percepção da Fala , Audiometria , Condução Óssea/fisiologia , Seguimentos , Perda Auditiva Condutiva , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/terapia , Humanos , Resultado do Tratamento
10.
Front Surg ; 9: 885964, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36117815

RESUMO

Osseointegration, the ability for an implant to be anchored in bone tissue with direct bone-implant contact and allowing for continuous adaptive remodelling, is clinically used in different reconstructive fields, such as dentistry, orthopedics and otology. The latter uses a bone conducting sound processor connected to a skin-penetrating abutment that is mounted on a titanium implant placed in the temporal bone, thereby acting as a path for transmission of the vibrations generated by the sound processor. The success of the treatment relies on bone healing and osseointegration, which could be improved by surface modifications. The aim of this study was to evaluate the long-term osseointegration in a sheep skull model and compare a laser-ablated implant surface with a machined implant. Commercially available 4 mm titanium implants, either with a machined (Wide Ponto) or a laser-ablated surface (Ponto BHX, Oticon Medical, Sweden), were used in the current study. The surfaces were evaluated by scanning electron microscopy. The implantation was performed with a full soft tissue flap and the osteotomy was prepared using the MIPS drill kit (Oticon Medical, Sweden) prior to installation of the implants in the frontal bone of eight female sheep. After five months, biopsies including the implant and surrounding bone tissue obtained, processed and analysed using histology, histomorphometry, scanning electron microscopy and Raman spectroscopy. The animals healed well, without signs of adverse events. Histomorphometry showed a large amount of bone tissue around both implant types, with 75% of the threaded area occupied by bone for both implant types. A large amount of bone-implant contact was observed for both implant types, with 67%-71% of the surface covered by bone. Both implant types were surrounded by mature remodelled lamellar bone with high mineral content, corroborating the histological observations. The current results show that the laser-ablated surface induces healing similar to the well-known clinically used machined surface in ovine cranial bone. In conclusion, the present long-term experimental results indicate that a laser-ablated implant performs equally well as a clinically used implant with a machined surface. This, together with previously reported, improved early biomechanical anchorage, suggests future, safe and efficient clinical potential.

11.
Laryngoscope Investig Otolaryngol ; 6(3): 446-452, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34195366

RESUMO

OBJECTIVES: The aim of this study was to analyze the timing of tracheotomy and the duration of mechanical ventilation and stay in the intensive care unit (ICU) in patients with COVID-19 infection. Furthermore, we aimed to investigate tracheotomy complications and mortality. METHODS: Consecutive patients with COVID-19 infection admitted to the Department of Infectious Diseases in Gothenburg, Sweden were identified. Medical records were retrieved and retrospectively assessed. RESULTS: One hundred eighty-eight patients with COVID-19 infection requiring hospital care were identified. Of these, 116 patients were critically ill and intubated, and 55 patients underwent tracheotomy. The mean time from endotracheal intubation to tracheotomy was 12 days (range 5-28 days). There was a correlation between the timing of tracheotomy and the duration of mechanical ventilation, where a shorter time between intubation and tracheotomy was correlated with a shorter duration of mechanical ventilation (r .58, P < .001), and a correlation was identified between the timing of tracheotomy and the duration of ICU stay (r .52, P < .001). Perioperative hypoxemia was registered in 9% of tracheotomies performed, whereas postoperative bleeding was observed in 27% of cases, the majority of which were minor. CONCLUSIONS: This retrospective cohort study indicates that early tracheotomy is related to a reduced need for mechanical ventilation and a shorter duration of stay in the ICU in severe cases of COVID-19 disease. Complications during and after tracheotomy in this specific cohort included risk perioperative hypoxia and postoperative bleeding. Prospective randomized controlled trials would be of value to confirm these findings. LEVEL OF EVIDENCE: 4, Case series.

12.
Med Devices (Auckl) ; 14: 225-237, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34267559

RESUMO

OBJECTIVE: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation. METHODS: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone. RESULTS: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ. CONCLUSION: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones.

13.
Int J Audiol ; 49(3): 203-15, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20105095

RESUMO

Percutaneous bone anchored hearing aids (BAHA) are today an important rehabilitation alternative for patients suffering from conductive or mixed hearing loss. Despite their success they are associated with drawbacks such as skin infections, accidental or spontaneous loss of the bone implant, and patient refusal for treatment due to stigma. A novel bone conduction implant (BCI) system has been proposed as an alternative to the BAHA system because it leaves the skin intact. Such a BCI system has now been developed and the encapsulated transducer uses a non-screw attachment to a hollow recess of the lateral portion of the temporal bone. The aim of this study is to describe the basic engineering principals and some preclinical results obtained with the new BCI system. Laser Doppler vibrometer measurements on three cadaver heads show that the new BCI system produces 0-10 dB higher maximum output acceleration level at the ipsilateral promontory relative to conventional ear-level BAHA at speech frequencies. At the contralateral promontory the maximum output acceleration level was considerably lower for the BCI than for the BAHA.


Assuntos
Condução Óssea , Auxiliares de Audição , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Desenho de Prótese , Implantação de Prótese/métodos
14.
Front Surg ; 7: 5, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32211417

RESUMO

Background: Soft tissue preservation using a hydroxyapatite-coated abutment in bone conduction hearing implant surgery may lead to improved clinical outcomes over the short (1 year) and long term (3 years). Methods: In this open multi-center, randomized (1:1), controlled clinical trial, subjects with conductive, mixed hearing loss or single-sided sensorineural deafness were randomly assigned to receive the conventional intervention, a titanium abutment with soft tissue reduction surgery (control), or a new intervention, a hydroxyapatite-coated abutment with soft tissue preservation surgery (test). The primary efficacy outcome was the combined endpoint of numbness, pain, peri-abutment dermatitis, and soft tissue thickening/overgrowth after 1 and 3 years. Results: The Intention-to-treat (ITT) population consisted of 52 control subjects and 51 test subjects. The difference between the groups after 1 year of follow-up as measured by the primary efficacy outcome was not statistically significant (p = 0.12) in the ITT population (n = 103), but did reach statistical significance (p = 0.03) in the per-protocol (PP) population (n = 96). It showed an advantage for the test group, with over twice as many subjects (29%) without these medical events during the first year compared to the control group (13%). After 3 years, the difference between the two groups had declined and did not reach statistical significance (24 vs. 10%, ITT p = 0.45). Secondary outcome measures which showed a statistical significant difference during the first year, such as surgical time (15 vs. 25 minutes, p < 0.0001), numbness (90 vs. 69% of subjects experienced no numbness at 1 year, p < 0.01), neuropathic pain at 3 months (p = 0.0087) and the overall opinion of the esthetic outcome (observer POSAS scale at 3 months, p < 0.01) were favorable for the test group. More soft tissue thickening/overgrowth was observed at 3 weeks for the test group (p = 0.016). Similar results were achieved for the long term follow up. Conclusions: Soft tissue preservation with a hydroxyapatite-coated abutment leads to a reduction in the combined occurrence of complications over the first year which is not statistically significant in the ITT population but is in the PP population. This effect decreased for the long-term study follow up of 3 years and did also not reach statistical significance.

15.
Med Devices (Auckl) ; 12: 193-202, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31239790

RESUMO

Objective: Active transcutaneous bone conduction devices consist of an external audio processor and an internal implant under intact skin. During the surgical procedure, it is important to verify the functionality of the implant before the surgical wound is closed. In a clinical study with the new bone conduction implant (BCI), the functionality of the implant was tested with an electric transmission test, where the output was the nasal sound pressure (NSP) recorded in the ipsilateral nostril. The same measurement was performed in all follow-up visits to monitor the implant's functionality and transmission to bone over time. The objective of this study was to investigate the validity of the NSP method as a tool to objectively verify the implant's performance intraoperatively, as well as to follow-up the implant's performance over time. Design: Thirteen patients with the BCI were included, and the NSP measurement was part of the clinical study protocol. The implant was electrically stimulated with an amplitude-modulated signal generator using a swept sine 0.1-10 kHz. The NSP was measured with a probe tube microphone in the ipsilateral nostril. Results: The NSP during surgery was above the noise floor for most patients within the frequency interval 0.4-5 kHz, showing NSP values for expected normal transmission of a functioning implant. Inter-subject comparison showed large variability, but follow-up results showed only minor variability within each subject. Further investigation showed that the NSP was stable over time. Conclusion: The NSP method is considered applicable to verify the implant's functionality during and after surgery. Such a method is important for implantable devices, but should be simplified and clinically adapted. Large variations between subjects were found, as well as smaller variability in intra-subject comparisons. As the NSP was found to not change significantly over time, stable transmission to bone, and implant functionality, were indicated.

16.
Med Devices (Auckl) ; 12: 89-100, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30881150

RESUMO

OBJECTIVES: The objective of this study was to develop methods for evaluating the mechanical robustness and estimating the lifetime of the novel bone conduction implant (BCI) that is used in a clinical study. The methods are intended to be applicable to any similar device. MATERIALS AND METHODS: The robustness was evaluated using tests originally developed for cochlear implants comprising a random vibration test, a shock test, a pendulum test, and an impact test. Furthermore, magnetically induced torque and demagnetization during magnetic resonance imaging at 1.5 T were investigated using a dipole electromagnet. To estimate the lifetime of the implant, a long-term age-accelerated test was performed. RESULTS: Out of all the tests, the pendulum and the impact tests had the largest effect on the electro-acoustic performance of the BCI implant, even if the change in performance was within acceptable limits (<20%). In comparison with baseline data, the lower and higher resonance peaks shifted down in frequency by 13% and 18%, respectively, and with a loss in magnitude of 1.1 and 2.0 dB, respectively, in these tests. CONCLUSION: A complete series of tests were developed, and the BCI passed all the tests; its lifetime was estimated to be at least 26 years for patients who are using the implant for 12 hours on a daily basis.

17.
Hear Res ; 381: 107763, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-31387072

RESUMO

Direct drive bone conduction devices (BCDs) are used to rehabilitate patients with conductive or mixed hearing loss by stimulating the skull bone directly, either with an implanted transducer (active transcutaneous BCDs), or through a skin penetrating abutment rigidly coupled to an external vibrating transducer (percutaneous BCDs). Active transcutaneous BCDs have been under development to overcome limitations of the percutaneous bone anchored hearing aid (BAHA), mainly related to the skin penetration. The attachment of a direct drive BCD to the skull bone can differ significantly between devices, and possibly influence the vibrations' transmission to the cochleae. In this study, four different attachments are considered: (A) small-sized flat surface, (B) extended flat surface, (C) bar with a screw at both ends, and (D) standard bone anchored hearing aid screw. A, B, and C represent three active transcutaneous options, while D is for percutaneous applications. The primary aim of this study was to investigate how the different transcutaneous attachments (A, B, and C) affect the transmission of vibrations to the cochleae to the ipsilateral and the contralateral side. A secondary aim was to evaluate and compare transcranial attenuation (TA, ipsilateral minus contralateral signal level) between transcutaneous (A, B, and C) and percutaneous attachments (D). Measurements were performed on four human heads, measuring cochlear promontory velocity with a LDV (laser Doppler vibrometer) and sound pressure in the ear canal (ECSP) with an inserted microphone. The stimulation signal was a swept sine between 0.1 and 10 kHz. The comparison of ipsilateral transmission between transcutaneous adaptors A, B, and C was in agreement with previous findings, confirming that: (1) Adaptor C seems to give the most effective transmission for frequencies around 6 kHz but somewhat lower in the mid frequency range, and (2) keeping a smaller contact area seems to provide advantages compared to a more extended one. The same trends were seen ipsilaterally and contralaterally. The observed TA was similar for adaptors A, B, and C at the mastoid position, ranging -10-0 dB below 500 Hz, and 10-20 dB above. A lower TA was seen above 500 Hz when using adaptor D at the parietal position.


Assuntos
Condução Óssea , Prótese Ancorada no Osso , Cóclea/fisiopatologia , Auxiliares de Audição , Perda Auditiva/reabilitação , Processo Mastoide/cirurgia , Osso Parietal/cirurgia , Pessoas com Deficiência Auditiva/reabilitação , Implantação de Prótese/instrumentação , Cadáver , Feminino , Perda Auditiva/fisiopatologia , Humanos , Masculino , Mecanotransdução Celular , Desenho de Prótese , Vibração
18.
Int J Audiol ; 47(12): 761-9, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19085400

RESUMO

One limitation with the Bone Anchored Hearing Aid (Baha) is too poor amplification for patients with moderate to severe sensorineural hearing losses. Therefore, we investigated if bone conducted (BC) sound transmission improves when the stimulation approaches the cochlea. Also the influence from the squamosal suture on BC sound transmission was investigated. Both sides of the heads on seven human cadavers were used and vibrational stimulation was applied at eight positions on each side with a frequency range of 0.1-10 kHz. A laser Doppler vibrometer was used to measure the resulting velocity of the cochlear promontory. It was found that the velocity of the promontory increases as the stimulation position approaches the cochlea; this was especially apparent at distances within 2.5 cm from the ear canal opening and when the stimulation position was in the opened mastoid. At frequencies above 500 Hz there was on average 10 to 20 dB greater vibrational response at the cochlea when the stimulation was close to the cochlea compared with the normal Baha position. Moreover, even if there were general indications of attenuation of BC sound when passing the squamosal suture, an effect from the suture could not be conclusively determined.


Assuntos
Condução Óssea , Cóclea/fisiologia , Crânio/fisiologia , Testes de Impedância Acústica , Idoso , Idoso de 80 Anos ou mais , Cadáver , Suturas Cranianas/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Vibração
19.
Med Devices (Auckl) ; 11: 301-312, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30233258

RESUMO

OBJECTIVE: A new prototype bone conduction (BC) transducer B250, with an emphasized low-frequency response, is evaluated in vestibular evoked myogenic potential (VEMP) investigations. The aim was to compare cervical (cVEMP) and ocular (oVEMP) responses using tone bursts at 250 and 500 Hz with BC stimulation using the B250 and the conventional B81 transducer and by using air conduction (AC) stimulation. METHODS: Three normal subjects were investigated in a pilot study. BC stimulation was applied to the mastoids in cVEMP, and both mastoid and forehead in oVEMP investigations. RESULTS: BC stimulation was found to reach VEMP thresholds at considerably lower hearing levels than in AC stimulation (30-40 dB lower oVEMP threshold at 250 Hz). Three or more cVEMP and oVEMP responses at consecutive 5 dB increasing mastoid stimulation levels were only obtained in all subjects using the B250 transducer at 250 Hz. Similar BC thresholds were obtained for both ipsilateral and contralateral mastoid stimulation. Forehead stimulation, if needed, may require a more powerful vibration output. CONCLUSION: Viable VEMP responses can be obtained at a considerably lower hearing level with BC stimulation than by AC stimulation. The cVEMP and oVEMP responses were similar when measured on one side and with the B250 attached to both ipsilateral and contralateral mastoids.

20.
Hear Res ; 361: 103-112, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29429820

RESUMO

Active transcutaneous bone conduction devices, where the transducer is implanted, are used for rehabilitation of hearing impaired patients by directly stimulating the skull bone. The transducer and the way it is attached to the bone play a central role in the design of such devices. The actual effect of varying the contact to bone has not been addressed yet. The aim of this study is therefore to compare how different attachment methods of the transducer to the bone for direct stimulation affect the ear canal sound pressure and vibration transmission to the ipsilateral cochlea. Three different attachments to the bone were tested: (A) via a flat small-sized surface, (B) via a flat wide surface and (C) via two separated screws. Measurements were done on four human heads on both sides. The attachments were compared in terms of induced cochlear promontory velocity, measured by a laser Doppler vibrometer, and ear canal sound pressure, measured by a low noise microphone. A swept sine stimulus was used in the frequency range 0.1-10 kHz. On an average level, the attachment method seems to affect the transmission mainly at frequencies above 5 kHz. Furthermore, the results suggest that a smaller contact surface might perform better in terms of transmission of vibrations at mid and high frequencies. However, when considering the whole frequency range, average results from the different attachment techniques are comparable.


Assuntos
Percepção Auditiva , Condução Óssea , Auxiliares de Audição , Transtornos da Audição/terapia , Pessoas com Deficiência Auditiva/reabilitação , Transdutores , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Cadáver , Cóclea/fisiopatologia , Meato Acústico Externo/fisiopatologia , Desenho de Equipamento , Feminino , Transtornos da Audição/diagnóstico , Transtornos da Audição/fisiopatologia , Transtornos da Audição/psicologia , Humanos , Masculino , Teste de Materiais , Mecanotransdução Celular , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Pressão , Vibração