Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Anal Chem ; 95(12): 5354-5361, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36913630

RESUMO

Intramolecular or position-specific carbon isotope analysis of propane (13CH3-12CH2-12CH3 and 12CH3-13CH2-12CH3) provides unique insights into its formation mechanism and temperature history. The unambiguous detection of such carbon isotopic distributions with currently established methods is challenging due to the complexity of the technique and the tedious sample preparation. We present a direct and nondestructive analytical technique to quantify the two singly substituted, terminal (13Ct) and central (13Cc), propane isotopomers, based on quantum cascade laser absorption spectroscopy. The required spectral information on the propane isotopomers was first obtained using a high-resolution Fourier-transform infrared (FTIR) spectrometer and then used to select suitable mid-infrared regions with minimal spectral interference to obtain the optimum sensitivity and selectivity. We then measured high-resolution spectra around 1384 cm-1 of both singly substituted isotopomers by mid-IR quantum cascade laser absorption spectroscopy using a Stirling-cooled segmented circular multipass cell (SC-MPC). The spectra of the pure propane isotopomers were acquired at both 300 and 155 K and served as spectral templates to quantify samples with different levels of 13C at the central (c) and terminal (t) positions. A prerequisite for the precision using this reference template fitting method is a good match of amount fraction and pressure between the sample and templates. For samples at natural abundance, we achieved a precision of 0.33 ‰ for δ13Ct and 0.73 ‰ for δ13Cc values within 100 s integration time. This is the first demonstration of site-specific high-precision measurements of isotopically substituted non-methane hydrocarbons using laser absorption spectroscopy. The versatility of this analytical approach may open up new opportunities for the study of isotopic distribution of other organic compounds.

2.
Anal Chem ; 95(5): 2857-2864, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36700547

RESUMO

Volatile organic compounds (VOCs) exhibit typically broad and mutually overlapping ro-vibrational absorption fingerprints. This complexity has so far limited the applicability of laser-based spectroscopy for VOC measurements in complex gas matrices. Here, we exploit a Vernier-type quantum-cascade laser (QCL) as an electrically tunable multiwavelength source for selective and sensitive VOC analysis. This emerging class of lasers provides access to several spectral windows by discrete Vernier tuning ("switching") and continuous coverage within these windows ("scanning"). We present a versatile driving technique that efficiently combines the two tuning mechanisms. Applied to our Vernier QCL, it enables the rapid acquisition (within 360 ms) of high-resolution spectra from six individual spectral windows, distributed over a wide range from 1063 to 1102 cm-1. Gaining access to the broad absorption envelopes of VOCs at multiple frequencies, along with their superimposed fine structure, which are especially pronounced at a reduced sample pressure, offers completely new opportunities in VOC analysis. The potential of this approach is assessed in a direct-laser-absorption setup with acetaldehyde, ethanol, and methanol as benchmark compounds with significant spectral overlaps. A measurement precision of 1-10 ppb is obtained after integration for 10 s at amount fractions below 10 ppm, and excellent linearity is found over at least 3 orders of magnitude. Combined with our dedicated spectral fitting algorithm, we demonstrate highly selective multicompound analyses with less than 3.5% relative expanded uncertainty, even in the presence of a 40× excess of an interfering compound with complete spectral overlap.

3.
Environ Sci Technol ; 57(32): 11903-11912, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37506302

RESUMO

For the past few years, short-lived unsaturated halocarbons have been marketed as environmentally friendly replacements for long-lived halogenated greenhouse gases and ozone-depleting substances. The phase-in of unsaturated halocarbons for various applications, such as refrigeration and foam blowing, can be tracked by their emergence and increase in the atmosphere. We present the first atmospheric measurements of the hydrofluoroolefin (HFO) HFO-1336mzz(Z) ((Z)-1,1,1,4,4,4-hexafluoro-2-butene, cis-CF3CH═CHCF3), a newly used unsaturated hydrofluorocarbon. HFO-1336mzz(Z) has been detected in >90% of all measurements since 2018 during multi-month campaigns at three Swiss and one Dutch location. Since 2019, it is found in ∼30% of all measurements that run continuously at the Swiss high-altitude Jungfraujoch station. During pollution events, mole fractions of up to ∼10 ppt were observed. Based on our measurements, Swiss and Dutch emissions were estimated at 2-7 Mg yr-1 (2019-2021) and 30 Mg yr-1 (2022), respectively. Modeled spatial emission distributions only partly conform to population density in both countries. Monitoring the presence of new unsaturated halocarbons in the atmosphere is crucial since long-term effects of their degradation products are still debated. Furthermore, the production of HFOs involves climate-active substances, which may leak to the atmosphere─in the case of HFO-1336mzz(Z), for example, the ozone-depleting CFC-113a (CF3CCl3).


Assuntos
Gases de Efeito Estufa , Hidrocarbonetos Halogenados , Ozônio , Hidrocarbonetos Halogenados/análise , Monitoramento Ambiental , Atmosfera
4.
Opt Express ; 30(3): 4631-4641, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35209695

RESUMO

We present a quantum cascade laser-based absorption spectrometer deploying a compact (145 mL volume) segmented circular multipass cell (SC-MPC) with 6 m optical path length. This SC-MPC is embedded into an effective cooling system to facilitate operation at cryogenic temperatures. For CO2, the sample is cooled to 153 K, i.e. close to the sublimation point at 10 mbar. This enables efficient suppression of interfering hot-band transitions of the more abundant isotopic species and thereby enhances analytical precision. As a demonstration, the amount fractions of all three CO2 isotopologues involved in the kinetic isotope exchange reaction of 12C16O2 + 12C18O2⇌ 2·12C16O18O are measured. The precision in the ratios [12C18O2]/[12C16O2] and [12C16O18O]/[12C16O2] is 0.05 ‰ with 25 s integration time. In addition, we determine the variation of the equilibrium constant, K, of the above exchange reaction for carbon-dioxide samples equilibrated at 300 K and 1273 K, respectively.

5.
Opt Express ; 30(20): 36087-36095, 2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36258545

RESUMO

Optical frequency combs based on semiconductor lasers are a promising technology for monolithic integration of dual-comb spectrometers. However, the stabilization of offset frequency fceo remains a challenging feat due the lack of octave-spanning spectra. In a dual-comb configuration, the uncorrelated jitter of the offset frequencies leads to a non-periodic signal resulting in broadened beatnotes with a limited signal-to-noise ratio (SNR). Hence, expensive data acquisition schemes and complex signal processing are currently required. Here, we show that the offset frequencies of two frequency combs can be synchronized by optical injection locking, which allows full phase-stabilization when combined with electrical injection locking of both repetition frequencies frep. A single comb line isolated via an optical Vernier filter serves as Master oscillator for injection locking. The resulting dual-comb signal is periodic and stable over thousands of periods. This enables coherent averaging using analog electronics, which increases the SNR and reduces the data size by one and three orders of magnitude, respectively. The presented method will enable fully phase-stabilized dual-comb spectrometers by leveraging on integrated optical filters and provides access for comparing and stabilizing fceo to narrow-linewidth optical references.

6.
Opt Lett ; 47(3): 625-628, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35103695

RESUMO

In dual-comb spectroscopy, there is a one-to-one map between the frequencies of the measured beat notes and the frequencies of the optical comb lines. Its determination usually involves the use of one or more reference lasers with known frequencies. Quantum cascade laser frequency combs, however, are often operated in a free-running mode, and without a reference, the determination of the RF-to-optical frequency map is not trivial. Here, we propose a method by which the comb shift is measured with an unbalanced Mach-Zehnder interferometer, and the spectral point spacing is determined through the intermode beat measured on the laser electrodes. The frequency axis is accurate within ∼ 0.001 cm-1.

7.
Sensors (Basel) ; 22(23)2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36501859

RESUMO

Precise and accurate measurements of ambient HNO3 are crucial for understanding various atmospheric processes, but its ultra-low trace amounts and the high polarity of HNO3 have strongly hindered routine, widespread, direct measurements of HNO3 and restricted field studies to mostly short-term, localized measurement campaigns. Here, we present a custom field-deployable direct absorption laser spectrometer and demonstrate its analytical capabilities for in situ atmospheric HNO3 measurements. Detailed laboratory characterizations with a particular focus on the instrument response under representative conditions for tropospheric measurements, i.e., the humidity, spectral interference, changing HNO3 amount fractions, and air-sampling-related artifacts, revealed the key aspects of our method: (i) a good linear response (R2 > 0.98) between 0 and 25 nmol·mol−1 in both dry and humid conditions with a limit of detection of 95 pmol·mol−1; (ii) a discrepancy of 20% between the spectroscopically derived amount fractions and indirect measurements using liquid trapping and ion chromatography; (iii) a systematic spectral bias due to water vapor. The spectrometer was deployed in a three-week field measurement campaign to continuously monitor the HNO3 amount fraction in ambient air. The measured values varied between 0.1 ppb and 0.8 ppb and correlated well with the daily total nitrates measured using a filter trapping method.


Assuntos
Poluentes Atmosféricos , Poluentes Atmosféricos/análise , Ar/análise , Nitratos , Lasers
8.
Chimia (Aarau) ; 76(7-8): 656-660, 2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-38071632

RESUMO

Nitrous oxide (N2O) is an important trace gas contributing to global warming and depletion of ozone in the stratosphere. Its increasing abundance is caused mainly by anthropogenic sources, such as application of fertilizers in agriculture or emissions from industry. To understand the N2O global budget, its sources and sinks need to be well-described and quantified. In this project, a new method for N2O source appointment was developed that can help with this task. The method is based on analysis of the eight most abundant isotopic molecules of N2O, using quantum cascade laser absorption spectroscopy (QCLAS). The applicability of the method towards the N2O biogeochemical cycle was demonstrated on a prominent N2O source (bacterial denitrification) and the most important N2O sink (UV photolysis) on samples prepared in laboratory experiments. An extension of the QCLAS method to natural samples can be achieved by hyphenation with a preconcentration technique that increases concentration of the analyte and standardizes the sample matrix. This article provides an overview of currently applied preconcentration techniques in the field of greenhouse-gas analysis and a description of the preconcentration device TREX that will be employed in future projects with the developed QCLAS method.

9.
Opt Express ; 28(5): 6197-6208, 2020 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-32225874

RESUMO

We present gapless, high-resolution absorption and dispersion spectra obtained with quantum cascade laser frequency combs covering 55 cm-1. Using phase-sensitive dual comb design, the comb lines are gradually swept over 10 GHz, corresponding to the free spectral range of the laser devices, by applying a current modulation. We show that with interleaving the spectral point spacing is reduced by more than four orders of magnitude over the full spectral span of the frequency comb. The potential of this technique for high-precision gas sensing is illustrated by measuring the low pressure (107 hPa) absorption and dispersion spectra of methane spanning the range of 1170 cm-1 - 1225 cm-1 with a resolution of 0.001 cm-1.

10.
Rapid Commun Mass Spectrom ; 34(15): e8836, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32430945

RESUMO

RATIONALE: Unravelling the biogeochemical cycle of the potent greenhouse gas nitrous oxide (N2 O) is an underdetermined problem in environmental sciences due to the multiple source and sink processes involved, which complicate mitigation of its emissions. Measuring the doubly isotopically substituted molecules (isotopocules) of N2 O can add new opportunities to fingerprint and constrain its cycle. METHODS: We present a laser spectroscopic technique to selectively and simultaneously measure the eight most abundant isotopocules of N2 O, including three doubly substituted species - so called "clumped isotopes". For the absolute quantification of individual isotopocule abundances, we propose a new calibration scheme that combines thermal equilibration of a working standard gas with a direct mole fraction-based approach. RESULTS: The method is validated for a large range of isotopic composition values by comparison with other established methods (laser spectroscopy using conventional isotopic scale and isotope ratio mass spectrometry). Direct intercomparison with recently developed ultrahigh-resolution mass spectrometry shows clearly the advantages of the new laser technique, especially with respect to site specificity of isotopic substitution in the N2 O molecule. CONCLUSIONS: Our study represents a new methodological basis for the measurements of both singly substituted and clumped N2 O isotopes. It has a high potential to stimulate future research in the N2 O community by establishing a new class of reservoir-insensitive tracers and molecular-scale insights.

11.
Chimia (Aarau) ; 74(3): 136-141, 2020 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-32197671

RESUMO

CFCs (chlorofluorocarbons) and other strong ozone-depleting halogenated organic trace gases were used in numerous industrial, household and agriculture applications. First atmospheric measurements of CFCs were performed in the 1970s, well ahead of the detection of the ozone hole in the 1980s. The continuous observation of these ozone-depleting substances (ODSs) is crucial for monitoring their global ban within the Montreal Protocol. In addition, also HFCs (fluorinated hydrocarbons) are measured, which were introduced as substitutes of ODSs and are potent greenhouse gases. Since 2000, Empa continuously measures more than 50 halogenated trace gases at the high-Alpine station of Jungfraujoch (3850 m asl) as part of the global AGAGE network (Advanced Global Atmospheric Gases Experiment). Jungfraujoch is the highest location worldwide where such measurements are performed, and the site where several of these compounds were measured in the atmosphere for the first time. The measurements at Jungfraujoch and at other globally well-positioned sites serve as an early warning system, i. e. before potentially harmful halogenated organic substances can accumulate and detrimentally affect the natural environment.

12.
Opt Express ; 27(4): 5314-5325, 2019 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-30876131

RESUMO

We report on the development and validation of a compact laser instrument using mid-IR direct absorption spectroscopy (DAS) for high-precision measurements of ethanol in breath-like air mixtures. Leveraging the intermittent continuous wave (iCW) driving for conventional narrow-band distributed feedback (DFB) quantum cascade laser (QCL) emitting around 9.3 µm and using a 25 m path length multiple-pass absorption cell at reduced pressure, a precision of 9 ppb (amount fraction, nmol mol-1) at 60 s integration time is achieved even in the presence of 5% of H2O and CO2. Thus, the instrument is well suitable for metrological studies to investigate observed, but yet unquantified, discrepancies between different breath alcohol reference-generation methods. The approach can be generalized and applied for other organic molecules in a wide range of applications.

13.
Chimia (Aarau) ; 73(4): 232-238, 2019 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-30975249

RESUMO

Nitrous oxide, N2O, is the environmentally most relevant constituent of the biogeochemical nitrogen cycle. Human activities, e.g. the agricultural use of mineral fertilizers, accelerate nitrogen transformations, leading to higher emissions of this strong greenhouse gas. Investigating the stable isotopic composition of N2O provides a better understanding of formation mechanisms to disentangle its variable source and sink processes. Mid-infrared (mid-IR) laser spectroscopy is a highly attractive technique to analyze N2O isotopocules based on their specific ro-vibrational absorption characteristics. Specifically, quantum cascade laser absorption spectroscopy (QCLAS) in combination with preconcentration has shown to be powerful for simultaneous and high-precision analysis of the main N2O isotopocules. Recently, in the scope of my PhD project, we have been advancing this analytical technique for the analysis of the very rare doubly substituted N2O isotopic species 15N14N18O, 14N15N18O, and 15N15N16O, also known as clumped isotopes. Currently, we are investigating the potential of these novel isotopic tracers to track the complex N2O production and consumption pathways. Improved understanding of the nitrogen cycle will be a major step towards N2O emission reduction.

14.
Opt Lett ; 43(11): 2434-2437, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29856397

RESUMO

Compact and lightweight laser absorption spectrometers for accurate trace gas measurements are of great scientific and commercial importance. In these instruments, the multipass cell (MPC) represents a critical element in terms of achievable size and sensitivity. Herein, we introduce a versatile MPC concept which unifies compactness, mechanical rigidity, and optical stability. Relying on fundamental cavity design principles and modern diamond turning techniques, we have developed a segmented circular MPC that allows efficient and interference-free beam folding. A prototype cell is presented featuring up to 10 m optical path length at a total mass of less than 200 g. Incorporated in a highly compact setup without additional beam pre-shaping optics, we demonstrate a normalized noise level of low 10-4 (2σ) at 1 Hz.

15.
Anal Chem ; 89(12): 6377-6383, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28514136

RESUMO

A broadly tunable mid-infrared vertical-external-cavity surface-emitting laser (VECSEL) is employed in a direct absorption laser spectroscopic setup to measure breath acetone. The large wavelength coverage of more than 30 cm-1 at 3.38 µm allows, in addition to acetone, the simultaneous measurement of isoprene, ethanol, methanol, methane, and water. Despite the severe spectral interferences from water and alcohols, an unambiguous determination of acetone is demonstrated with a precision of 13 ppbv that is achieved after 5 min averaging at typical breath mean acetone levels in synthetic gas samples mimicking human breath.


Assuntos
Lasers , Compostos Orgânicos Voláteis/análise , Testes Respiratórios , Humanos , Propriedades de Superfície
16.
Opt Lett ; 42(16): 3137-3140, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28809892

RESUMO

We present computational and experimental investigations of the beam folding properties and fringe suppression capabilities in monolithic toroidal multipass cells (MPCs) when combined with absorption masks. Coherent field simulations based on the Fresnel-Huygens theory were performed to understand the effect of multiple field truncations in such an optically semi-unstable mirror arrangement. The explicit numerical calculation of the radiation field at each reflection allows detailed optimization and performance analysis. We experimentally verified the evolving irradiance distributions and identified optimal initial field configurations. Furthermore, we suggest a proxy to estimate the noise level for specific initial conditions. These insights pave the way to a better optical performance and, thus, to even more lightweight and compact designs of this MPC type.

17.
J Opt Soc Am A Opt Image Sci Vis ; 33(5): 913-9, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-27140888

RESUMO

Absorption cells with circular geometry are a class of multipass reflection cells consisting of a single, circular mirror. They can be particularly favorable for trace gas measurements because of their mechanical robustness, simplicity, and their optical versatility. In this article, we present detailed theoretical considerations and ray tracing simulations for the optimization of the optical design of circular multipass reflection cells. A parabolic mirror shape in a confocal arrangement is found to be most suitable for long optical paths in a small volume. We experimentally demonstrate more than 12 m optical path in a 14.5 cm diameter gas cell and NO2 concentration measurements in ambient air with a measurement precision better than 0.1 ppb.

18.
Opt Express ; 23(2): 1512-22, 2015 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-25835908

RESUMO

The concept of a multi-wavelength quantum cascade laser emitting at two or more spectrally well-separated wavelengths is highly appealing for applied spectroscopy, as it allows detecting several species with compact and cost-efficient optical setups. Here we present a practical realization of such a dual-wavelength setup, which is based on a room-temperature quantum cascade laser emitting single-mode at 1600 cm-1 and 1900 cm-1 and is thus well-suited for simultaneous NO and NO2 detection. Operated in a time-division multiplexed mode, our spectrometer reaches detection limits of 0.5 and 1.5 ppb for NO2 and NO, respectively. The performance of the system is validated against the well-established chemiluminescence detection while measuring the NOx emissions on an automotive test-bench, as well as upon monitoring the pollution at a suburban site.

19.
Analyst ; 139(9): 2039-46, 2014 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-24151636

RESUMO

In this paper we present two compact, quantum cascade laser absorption spectroscopy based, sensors developed for trace substance detection in gases and liquids. The gas sensor, in its most integrated version, represents the first system combining a quantum cascade laser and a quantum cascade detector. Furthermore, it uses a toroidal mirror cell with a volume of only 40 cm(3) for a path length of up to 4 m. The analytical performance is assessed by the measurements of isotope ratios of CO2 at ambient abundance. For the (13)CO2/(12)CO2 isotope ratio, a measurement precision of 0.2‰ is demonstrated after an integration time of 600 s. For the liquid sensor, a microfluidic system is used to extract cocaine from saliva into a solvent (PCE) transparent in the mid-infrared. This system is bonded on top of a Si/Ge waveguide and the concentration of cocaine in PCE is measured through the interaction of the evanescent part of the waveguide optical mode and the solvent flowing on top. A detection limit of <100 µg mL(-1) was achieved with this system and down to 10 µg mL(-1) with a simplified, but improved system.

20.
Opt Lett ; 38(3): 257-9, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23381403

RESUMO

A multipass cell (MPC) design for laser absorption spectroscopy is presented. The development of this new type of optical cell was driven by stringent criteria for compactness, robustness, low volume, and ease of use in optical systems. A single piece of reflective toroidal surface forms a near-concentric cavity with a volume of merely 40 cm(3). Contrary to traditional MPCs, this design allows for flexible path-length adjustments by simply changing the aiming angle of the laser beam at the entrance window. Two effective optical path lengths of 2.2 and 4.1 m were chosen to demonstrate the cell's suitability for high-precision isotope ratio measurements of CO(2) at 1% and ambient mixing ratio levels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA