1.
J Gen Intern Med ; 31 Suppl 1: 46-52, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26951273

RESUMO

BACKGROUND: The Meaningful Use (MU) program has increased the national emphasis on electronic measurement of hospital quality. OBJECTIVE: To evaluate stroke MU and one VHA stroke electronic clinical quality measure (eCQM) in national VHA data and determine sources of error in using centralized electronic health record (EHR) data. DESIGN: Our study is a retrospective cross-sectional study of stroke quality measure eCQMs vs. chart review in a national EHR. We developed local SQL algorithms to generate the eCQMs, then modified them to run on VHA Central Data Warehouse (CDW) data. eCQM results were generated from CDW data in 2130 ischemic stroke admissions in 11 VHA hospitals. Local and CDW results were compared to chart review. MAIN MEASURES: We calculated the raw proportion of matching cases, sensitivity/specificity, and positive/negative predictive values (PPV/NPV) for the numerators and denominators of each eCQM. To assess overall agreement for each eCQM, we calculated a weighted kappa and prevalence-adjusted bias-adjusted kappa statistic for a three-level outcome: ineligible, eligible-passed, or eligible-failed. KEY RESULTS: In five eCQMs, the proportion of matched cases between CDW and chart ranged from 95.4 %-99.7 % (denominators) and 87.7 %-97.9 % (numerators). PPVs tended to be higher (range 96.8 %-100 % in CDW) with NPVs less stable and lower. Prevalence-adjusted bias-adjusted kappas for overall agreement ranged from 0.73-0.95. Common errors included difficulty in identifying: (1) mechanical VTE prophylaxis devices, (2) hospice and other specific discharge disposition, and (3) contraindications to receiving care processes. CONCLUSIONS: Stroke MU indicators can be relatively accurately generated from existing EHR systems (nearly 90 % match to chart review), but accuracy decreases slightly in central compared to local data sources. To improve stroke MU measure accuracy, EHRs should include standardized data elements for devices, discharge disposition (including hospice and comfort care status), and recording contraindications.


Assuntos
Registros Eletrônicos de Saúde/normas , Uso Significativo/normas , Acidente Vascular Cerebral/terapia , United States Department of Veterans Affairs/normas , Saúde dos Veteranos/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA