1.
Metrologia ; 552018.
Artigo em Inglês | MEDLINE | ID: mdl-30983635

RESUMO

Cold atoms are excellent metrological tools; they currently realize SI time and, soon, SI pressure in the ultra-high (UHV) and extreme high vacuum (XHV) regimes. The development of primary, vacuum metrology based on cold atoms currently falls under the purview of national metrology institutes. Under the emerging paradigm of the "quantum-SI", these technologies become deployable (relatively easy-to-use sensors that integrate with other vacuum chambers), providing a primary realization of the pascal in the UHV and XHV for the end-user. Here, we discuss the challenges that this goal presents. We investigate, for two different modes of operation, the expected corrections to the ideal cold-atom vacuum gauge and estimate the associated uncertainties. Finally, we discuss the appropriate choice of sensor atom, the light Li atom rather than the heavier Rb.

2.
J Vac Sci Technol A ; 36(2)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29881141

RESUMO

Ultra-high vacuum systems must often be constructed of materials with ultra-low outgassing rates to achieve pressure of 10-6 Pa and below. Any component placed into the ultra-high vacuum system must also be constructed of materials with ultra-low outgassing rates. Baking stainless steel vacuum components to a temperature range of 400 °C to 450 °C while under vacuum is an effective method to reduce the outgassing rate of vacuum components for use in ultra-high vacuum systems. The design, construction, and operation of a vacuum furnace capable of baking vacuum components to a temperature of 450° C while maintaining a pressure of 10-3 Pa or lower is described. The furnace has been used for extended bakes at 450 °C while maintaining pressures below 10-5 Pa. As an example, we obtained an outgassing rate of 1.2 × 10-9 Pa L s-1 for a gate valve baked for 20 days at a temperature of 420 °C.

3.
Artigo em Inglês | MEDLINE | ID: mdl-31092970

RESUMO

This article represents a recommended practice for the calibration of ionization gauges using the comparison method. In this method, ionization gauges are compared to a working standard that has an SI traceable calibration. The ionization gauge is either of the hot-cathode ionization type or the cold-cathode ionization type. Details of the calibration apparatus, the principle of operation of the gauges, data analysis, uncertainty budget, and reporting the uncertainty are given.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38496305

RESUMO

The measurement science in realizing and disseminating the unit for pressure in the International System of Units (SI), the pascal (Pa), has been the subject of much interest at NIST. Modern optical-based techniques for pascal metrology have been investigated, including multi-photon ionization and cavity ringdown spectroscopy. Work is ongoing to recast the pascal in terms of quantum properties and fundamental constants and in so doing, make vacuum metrology consistent with the global trend toward quantum-based metrology. NIST has ongoing projects that interrogate the index of refraction of a gas using an optical cavity for low vacuum, and count background particles in high vacuum to extreme high vacuum using trapped laser-cooled atoms.

5.
Metrologia ; 54(6): S125-S132, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29269961

RESUMO

The National Institute of Standards and Technology has recently begun a program to develop a primary pressure standard that is based on ultra-cold atoms, covering a pressure range of 1 × 10-6 Pa to 1 × 10-10 Pa and possibly lower. These pressures correspond to the entire ultra-high vacuum (UHV) range and extend into the extreme-high vacuum (XHV). This cold-atom vacuum standard (CAVS) is both a primary standard and absolute sensor of vacuum. The CAVS is based on the loss of cold, sensor atoms (such as the alkali-metal lithium) from a magnetic trap due to collisions with the background gas (primarily H2) in the vacuum. The pressure is determined from a thermally-averaged collision cross section, which is a fundamental atomic property, and the measured loss rate. The CAVS is primary because it will use collision cross sections determined from ab initio calculations for the Li + H2 system. Primary traceability is transferred to other systems of interest using sensitivity coefficients.

6.
Metrologia ; 54(Technical Suppl)2017.
Artigo em Inglês | MEDLINE | ID: mdl-28736459

RESUMO

The comparison CCM.P-K15 is a key comparison in pressure involving six laboratories in three regional metrological organizations (RMO). The measurand of the comparison is the accommodation coefficient of two spinning rotating gauge characterized in nitrogen from 0.1 mPa up to 1.0 Pa. The two transfer standards were circulated from November 2009 until March 2011. The circulation consisted of three loops, one for each RMO, and a new calibration by the pilot between each loop. The stability of one of the transfer standards was poor and was worse than expected based on the previous history of the transfer standard while the other transfer standard demonstrated good stability while circulated in Europe and America and a fair stability while circulated in Asia. All the participants demonstrated equivalence to the definition of pressure in their respective primary standards.

7.
J Vac Sci Technol A ; 35(4)2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-29200610

RESUMO

The authors investigated the outgassing rates and fluxes of vacuum chambers constructed from common 304L stainless steel vacuum components and subjected to heat treatments. Our goal was to obtain H2 outgassing flux on the order of 10-11 Pa l s-1cm-2 or better from standard stainless steel vacuum components readily available from a variety of manufacturers. The authors found that a medium-temperature bake in the range of 400 to 450°C, performed with the interior of the chamber under vacuum, was sufficient to produce the desired outgassing flux. The authors also found that identical vacuum components baked in air at the same temperature for the same amount of time did not produce the same low outgassing flux. In that case, the H2 outgassing flux was lower than that of a stainless-steel chamber with no heat treatment, but was still approximately 1 order of magnitude higher than that of the medium-temperature vacuum-bake. Additionally, the authors took the chamber that was subjected to the medium-temperature vacuum heat treatment and performed a 24-h air bake at 430°C. This additional heat treatment lowered the outgassing rate by nearly a factor of two, which strongly suggests that the air-bake created an oxide layer which reduced the hydrogen recombination rate on the surface. [http://dx.doi.org/10.1116/1.4983211].

8.
J Vac Sci Technol A ; 34(6)2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-28736481

RESUMO

We describe a vacuum apparatus for determining the outgassing rate into vacuum, the diffusion coefficient, and the amount of gas absorbed for various materials. The diffusion coefficient is determined from a model applied to time-dependent desorption data taken using a throughput method. We used this method to determine the diffusion coefficient, D, for H2O in 3-D printed acrylonitrile butadiene styrene (ABS). We found DH2O = 8.3 × 10-8 cm2/s ± 1.3 × 10-8 cm2/s (k = 1; 67% confidence interval) at 23.2 °C. This result was compared to the diffusion coefficient determined another by a gravimetric method, in which the sample weight was monitored as it absorbed gas from the atmosphere. The two methods agreed to within 3%, which is well within the uncertainty of the measurement. We also found that at least 80% of the atmospheric gas (air) absorbed by the ABS is water. The total amount of all atmospheric gas absorbed by ABS was about 0.35% by weight when exposed to ambient air in the laboratory, which was at a pressure of 101 kPa with a relative humidity of 57% at 22.2 °C.

9.
Rev Sci Instrum ; 93(12): 121101, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586922

RESUMO

We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.

10.
Artigo em Inglês | MEDLINE | ID: mdl-33283081

RESUMO

We have computed the thermally averaged total, elastic rate coefficient for the collision of a room-temperature helium atom with an ultracold lithium atom. This rate coefficient has been computed as part of the characterization of a cold-atom vacuum sensor based on laser-cooled 6Li or 7Li atoms that will operate in the ultrahigh-vacuum (p < 10-6 Pa) and extreme-high-vacuum (p < 10-10 Pa) regimes. The analysis involves computing the X 2 Σ+ HeLi Born-Oppenheimer potential followed by the numerical solution of the relevant radial Schrodinger equation. The potential is computed using a single-reference-coupled-cluster electronic-structure method with basis sets of different completeness in order to characterize our uncertainty budget. We predict that the rate coefficient for a 300 K helium gas and a 1 µK Li gas is 1.467(13) × 10-9 cm3/s for 4He + 6Li and 1.471(13) × 10-9 cm3/s for 4He + 7Li, where the numbers in parentheses are the one-standard-deviation uncertainties in the last two significant digits. We quantify the temperature dependence as well. Finally, we evaluate the s-wave scattering length and binding of the single van der Waals bound state of HeLi. We predict that this weakly bound level has a binding energy of -0.0064(43) × hc cm-1 and -0.0122(67) × hc cm-1 for 4He6Li and 4He7Li, respectively. The calculated binding energy of 4He7Li is consistent with the sole experimental determination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA