Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Br J Surg ; 104(8): 1020-1027, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28401533

RESUMO

BACKGROUND: Fenestrated endovascular aneurysm repair (FEVAR) is increasingly being used for juxtarenal aortic aneurysms. The aim of this study was to review long-term results and assess the importance of changing stent-graft design on outcomes. METHODS: This was a retrospective review of all patients who underwent FEVAR within a single unit over 12 years (February 2003 to December 2015). Kaplan-Meier analysis of survival, and freedom from target vessel loss, aneurysm expansion, graft-related endoleak and secondary intervention was performed. Comparison between outcomes of less complex grafts (fewer than 3 fenestrations) and more complex grafts (3 or 4 fenestrations) was undertaken. RESULTS: Some 173 patients underwent FEVAR; median age was 76 (i.q.r. 70-79) years and 90·2 per cent were men. Median aneurysm diameter was 63 (59-71) mm and median follow-up was 34 (16-50) months. The adjusted primary technical operative success rate was 95·4 per cent. The in-hospital mortality rate was 5·2 per cent; there was no known aneurysm-related death during follow-up. Median survival was 7·1 (95 per cent c.i. 5·2 to 8·1) years and overall survival was 60·1 per cent (104 of 173). There was a trend towards an increasing number of fenestrations in the graft design over time. In-hospital mortality appeared higher when more complex stent-grafts were used (8 versus 2 per cent for stent-grafts with 3-4 versus fewer than 3 fenestrations; P = 0·059). Graft-related endoleaks were more common following deployment of stent-grafts with three or four fenestrations (12 of 90 versus 6 of 83; P < 0·001). CONCLUSION: Fenestrated endovascular aneurysm repair for juxtarenal aneurysm is associated with few aneurysm-related deaths in the long term. Significant numbers of secondary interventions are required, but the majority of these can be performed using an endovascular approach.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Stents/tendências , Assistência ao Convalescente , Idoso , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular/tendências , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/mortalidade , Tempo de Internação , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese/mortalidade , Desenho de Prótese/tendências , Estudos Retrospectivos , Deiscência da Ferida Operatória/etiologia , Deiscência da Ferida Operatória/metabolismo , Análise de Sobrevida
2.
Phys Rev Lett ; 110(6): 065004, 2013 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-23432263

RESUMO

We report the first observation of prompt neutral beam-ion losses due to nonresonant scattering induced by toroidal and reversed shear Alfvén eigenmodes in the DIII-D tokamak. The coherent losses are of full energy beam ions expelled from the plasma on their first poloidal orbit. The first-orbit loss mechanism causes enhanced, concentrated losses on the first wall exceeding nominal levels of prompt losses. The loss amplitude scales linearly with the mode amplitude. The data provide a novel and direct measure of the radial excursion or scatter of particles induced by individual modes and may shed light on the mechanism for the scattering of energetic particles in interstellar medium.

3.
Phys Rev Lett ; 109(3): 035003, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861863

RESUMO

From numerical simulation and analytical modeling it is shown that fast ions can resonate with plasma waves at fractional values of the particle drift-orbit transit frequency when the plasma wave amplitude is sufficiently large. The fractional resonances, which are caused by a nonlinear interaction between the particle orbit and the wave, give rise to an increased density of resonances in phase space which reduces the threshold for stochastic transport. The effects of the fractional resonances on spatial and energy transport are illustrated for an energetic particle geodesic acoustic mode but they apply equally well to other types of MHD activity.

4.
Eur J Vasc Endovasc Surg ; 44(3): 327-31, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22819740

RESUMO

PURPOSE: Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. METHODS: A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. RESULTS: All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. CONCLUSIONS: Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon.


Assuntos
Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Artérias/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Falha de Prótese , Stents , Artérias/anatomia & histologia , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Modelos Anatômicos , Pressão , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo
5.
Eur J Vasc Endovasc Surg ; 41(3): 346-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21145265

RESUMO

INTRODUCTION: There are potential benefits of percutaneous over open femoral access for endovascular aneurysm repair (EVAR). Subsequent arterial closure using percutaneous devices is costly, whilst open repair risks potential wound complications and delayed discharge. The technique of fascial closure has perceived advantages but its efficacy is unclear. The aim of this study was to assess the safety and durability of fascial closure after EVAR. METHODS: Patients undergoing EVAR using devices up to 24 French were considered. Exclusion criteria included morbid obesity, high bifurcation, previous surgery, inadvertent high puncture, arteries < 5 mm and surgeon preference. The primary outcome measure was immediate technical success. All patients were followed-up clinically and with duplex at one and twelve months to determine secondary complications. RESULTS: Over a one-year period fascial closure of 69 common femoral arteries was attempted in 38 patients undergoing EVAR. Nine primary failures were due to haemorrhage in eight arteries and thrombosis in one artery; all had immediate, uncomplicated open revision. Of the 60 (87%) successful procedures, all had duplex surveillance at one month. Four pseudoaneurysms were identified, all treated conservatively. At one year, 61 fascial closures (88%) were imaged, four patients had died and two were lost to follow-up. Three of the pseudoaneurysms had resolved, the fourth patient had died (unrelated). No other complication attributable to fascial closure was found at either one or twelve months. CONCLUSION: Fascial closure is a safe, durable and cost-effective method of arterial closure following EVAR. Success and complication rates are comparable to other techniques.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Fasciotomia , Artéria Femoral/cirurgia , Hemorragia/prevenção & controle , Técnicas Hemostáticas , Técnicas de Fechamento de Ferimentos , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Inglaterra , Feminino , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Técnicas de Fechamento de Ferimentos/efeitos adversos
6.
Eur J Vasc Endovasc Surg ; 42(2): 187-92, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21546278

RESUMO

INTRODUCTION: Computed tomography angiography (CTA) is considered the gold standard imaging technique for surveillance following endovascular aneurysm repair (EVAR). Limitations of CTA include cost, risk of contrast nephropathy and radiation exposure. A modified surveillance protocol involving annual duplex ultrasound (DUS) and abdominal radiography (AXR) was introduced, with CTA performed only if abnormalities were identified or DUS was undiagnostic. METHODS: Prospective records were maintained on patients undergoing infra-renal EVAR at a UK, tertiary referral centre. All patients enrolled with at least one-year follow-up were reviewed. Primary outcomes identified were aneurysm rupture and aneurysm-related complications. Secondary outcomes included number of CTAs avoided and cost. RESULTS: Median follow-up was 36 months (range 12-57) for 194 patients. The total number of sets of surveillance imaging was 412 of which 70 (17%) required CTA. Abnormalities were found in 30 patients, 18 confirmed by CTA. Eleven patients required secondary intervention, three initially identified by AXR, three by DUS, three by both DUS and AXR, and two by CTA following undiagnostic DUS. No patient presented with rupture or aneurysm-related complications not identified by modified surveillance. Mean annual savings were €223. CONCLUSION: EVAR surveillance based on DUS and AXR is feasible and safe. The complimentary nature of AXR and DUS is demonstrated.


Assuntos
Aneurisma Aórtico/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias/diagnóstico , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler Dupla , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/economia , Aortografia/efeitos adversos , Aortografia/economia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/economia , Redução de Custos , Análise Custo-Benefício , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Inglaterra , Feminino , Custos Hospitalares , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/economia , Complicações Pós-Operatórias/terapia , Valor Preditivo dos Testes , Doses de Radiação , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/economia , Resultado do Tratamento , Ultrassonografia Doppler Dupla/economia , Procedimentos Desnecessários/economia
7.
Br J Surg ; 95(6): 703-8, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18446776

RESUMO

BACKGROUND: The aim was to evaluate a wholly endovascular approach to the repair of thoracoabdominal aortic aneurysm (TAAA). METHODS: Six patients (median age 71 years) underwent wholly endovascular repair of TAAA (maximum diameter 56-85 mm) employing individually customized endografts. Procedures were performed under general anaesthesia, with spinal drainage in five patients. Patients were followed by serial computed tomography, plain radiography and duplex imaging for a median of 17 (range 8-44) months. RESULTS: All grafts were deployed as intended, with preservation of all target vessels. There were no postoperative deaths, strokes or paraplegia. One patient suffered a silent myocardial infarction. In two patients a persistent paraostial endoleak was treated by further balloon dilatation of the stent within the endograft fenestration. Imaging before discharge confirmed aneurysm exclusion in all patients. Two patients required late secondary intervention to abolish endoleaks due to side-branch disconnection. One patient suffered late occlusion of the coeliac axis without clinical sequelae, and late occlusion of a solitary renal artery in another resulted in dependence on dialysis. There have been no late deaths and all aneurysms remain excluded. CONCLUSION: Wholly endovascular TAAA repair is relatively safe, but long-term follow-up is required to establish its durability.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Adulto , Idoso , Anestesia Geral , Prótese Vascular , Endarterectomia/métodos , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos
8.
Radiography (Lond) ; 23(4): 287-291, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28965890

RESUMO

INTRODUCTION: Planning of endovascular sealing of abdominal aortic aneurysms requires measurement of the aortic lumen volume. The aim of this study was to investigate mathematically the effect of intra- and inter-observer variability error, as well as cardiac cycle-related variability, on these measurements. METHODS: Mean (±2SD) intra- and inter-observer error in lumen measurements and mean (+2SD) cardiac cycle-related variability were obtained from published literature and added to the measurement of the flow lumen volume of a 57 mm abdominal aortic aneurysm to calculate average and extreme error possibilities. RESULTS: The aneurysm volume was measured at 165 ml. The calculated possible mean measurement error due to cardiac cycle variation, intra- and inter-observer variability was +11.0%, resulting in a potential measurement of 183.1 ml. The calculated extreme errors were +24.3% (if 2SD of all errors were added to the mean) and +3.5% (if 2SD of all errors, except cardiac cycle, were subtracted from the mean), resulting in potential measurements of 170.8 ml and 205.1 ml, respectively. When considering the errors combined, the proportion of patients who may have volume measurement errors of up to ±2.5 ml, ±2.6 to ±5.0 ml and ±5.1 to ±7.5 ml were 18%, 17% and 15%, respectively. CONCLUSION: Measurement of CT-based aortic lumen volumes in abdominal aortic aneurysms is imprecise. This has practical implications for the planning and the performance of complex endovascular therapies.


Assuntos
Aorta Abdominal/anatomia & histologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Erros de Diagnóstico , Procedimentos Endovasculares , Planejamento de Assistência ao Paciente , Tomografia Computadorizada por Raios X/métodos , Humanos , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador
9.
Sci Rep ; 7(1): 17712, 2017 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-29255200

RESUMO

Endovascular sealing is a new technique for the repair of abdominal aortic aneurysms. Commercially available in Europe since 2013, it takes a revolutionary approach to aneurysm repair through minimally invasive techniques. Although aneurysm sealing may be thought as more stable than conventional endovascular stent graft repairs, post-implantation movement of the endoprosthesis has been described, potentially leading to late complications. The paper presents for the first time a model, which explains the nature of forces, in static and dynamic regimes, acting on sealed abdominal aortic aneurysms, with references to real case studies. It is shown that elastic deformation of the aorta and of the endoprosthesis induced by static forces and vibrations during daily activities can potentially promote undesired movements of the endovascular sealing structure.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Prótese Vascular , Implante de Prótese Vascular/métodos , Simulação por Computador , Modelos Teóricos , Desenho de Prótese , Stents , Resultado do Tratamento
10.
Med Eng Phys ; 28(1): 27-35, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15921948

RESUMO

One of the main causes of long-term failure of ePTFE grafts is the development of anastomotic intimal hyperplasia which leads to graft thrombosis. Experimental studies with bypass grafts have shown an inverse relationship between mean wall shear stress and intimal hyperplasia. The geometry of the anastomosis has a strong influence on the flow pattern and wall shear stress distribution. The aim of this in vitro study was to investigate the influence of non-planarity in a model of a distal anastomosis with interposition vein cuff, an anastomosis configuration that is increasingly being used because of improved clinical results. Laser Doppler anemometer measurements were carried out in silicone rubber models of interposition vein cuff anastomoses with planar and non-planar inflow. The pulsatile flow waveforms were typical of those found in femoro-infrapopliteal bypass. Axial and radial velocities were measured in the proximal and distal outflow segments. As expected a symmetrical helical flow pattern (Dean flow) was evident in the planar model. The model with non-planar inflow, however, gave rise to swirling flow in both the distal and proximal artery outflow segments for during the systolic phase. In patients, the anastomosis is usually non-planar. Since the configuration depends in part upon the tunnelling of the graft, this may be altered to some extent. Non-planar anastomotic configurations induce a swirling flow pattern, which may normalise wall shear stress, thereby potentially reducing intimal hyperplasia.


Assuntos
Anastomose Cirúrgica , Simulação por Computador , Hemodinâmica/fisiologia , Ponte de Artéria Coronária , Oclusão de Enxerto Vascular/patologia , Humanos , Hiperplasia/patologia , Modelos Cardiovasculares , Estresse Mecânico , Sístole/fisiologia , Veias/patologia
11.
Am J Kidney Dis ; 32(4): E4, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10074590

RESUMO

Patient size has been suggested as a risk factor in kidney transplantation. We have followed a recipient of a cadaver kidney who became massively obese (232 kg, 511 lbs) 5 years posttransplantation. He has maintained stable renal function with no rejection episodes and at 5 years has a measured serum creatinine of 2.2 mg/dL, creatinine clearance 42 mL/min, and urinary protein excretion of 320 mg/24h. Both oral and intravenous cyclosporine (Sandimmune) pharmacokinetic studies were done on a steady-state dose of 150 mg, which represents 0.65 mg/kg per dose. The patient exhibited very high bioavailability, F = 95%, and an oral elimination T1/2 of over 21 hours. These data confirm that stable cyclosporine delivery in very obese recipients can be sustained by dosing normalized to the ideal body weight and trough level monitoring.


Assuntos
Ciclosporina/farmacocinética , Imunossupressores/farmacocinética , Transplante de Rim/fisiologia , Obesidade Mórbida/fisiopatologia , Disponibilidade Biológica , Cadáver , Ciclosporina/administração & dosagem , Diabetes Mellitus Tipo 1/complicações , Nefropatias Diabéticas/cirurgia , Humanos , Imunossupressores/administração & dosagem , Injeções Intravenosas , Falência Renal Crônica/cirurgia , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/etiologia
12.
J Biomech ; 37(3): 417-20, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14757463

RESUMO

Outflow distribution at the distal anastomosis of infrainguinal bypass grafts remains unquantified in vivo, but is likely to influence flow patterns and haemodynamics, thereby impacting upon graft patency. This study measured the ratio of distal to proximal outflow in 30 patients undergoing infrainguinal bypass for lower limb ischaemia, using a flow probe and a transit-time ultrasonic flow meter. The mean outflow distribution was approximately 75% distal to 25% proximal, with above knee anastomoses having a greater proportion of distal flow (84%) compared to below knee grafts (73%). These in vivo flow characteristics differ significantly from those used in theoretical models studying flow phenomena (50:50 and/or 100:0), and should be incorporated into future research.


Assuntos
Anastomose Cirúrgica/métodos , Anastomose Arteriovenosa/fisiopatologia , Isquemia/fisiopatologia , Isquemia/cirurgia , Perna (Membro)/irrigação sanguínea , Perna (Membro)/cirurgia , Transplantes , Idoso , Angiografia , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Feminino , Humanos , Isquemia/diagnóstico por imagem , Perna (Membro)/diagnóstico por imagem , Masculino , Fluxo Sanguíneo Regional , Ultrassonografia
13.
Biorheology ; 39(3-4): 461-5, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12122267

RESUMO

Clinical evidence suggests that the development of myointimal hyperplasia in prosthetic femorodistal bypass grafts may be reduced by the interposition of a cuff of autologous vein between the graft and the recipient artery. Previous experimental work has shown that some of the benefits may be attributed to the geometry of the cuffed anastomosis. Since the distal anastomosis in vivo is often non-planar we have carried out a preliminary study in a model where the graft is at an angle of 45 degrees to the anterior-posterior plane of the anastomosis. This out-of-plane angulation produces highly asymmetric flow patterns in the anastomosis with significant flow separation on the ipsilateral side of the cuff. In the proximal and distal outflow, however, the velocity vectors show significant helical motion with temporal instability in the distal outflow.


Assuntos
Anastomose Cirúrgica/efeitos adversos , Túnica Íntima/patologia , Artérias , Humanos , Hiperplasia , Canal Inguinal , Fluxo Sanguíneo Regional , Túnica Íntima/diagnóstico por imagem , Ultrassonografia
14.
Am J Vet Res ; 48(5): 852-4, 1987 May.
Artigo em Inglês | MEDLINE | ID: mdl-3592389

RESUMO

Anthelmintic efficacy, safety, and residue studies were conducted in sows and gilts with a levamisole gel containing 11.5% levamisole HCl. In 12 sows and 12 gilts, 8 mg of levamisole HCl equivalent/kg of body weight orally was 100% (resinate) and 91.1% (gel) effective against 55-day-old Ascaris suum and 100% (gel) and 96.1% (resinate) effective against Oesophagostomum dentatum. In 20 sows given levamisole gel (8 mg of levamisole HCl/kg) orally just before breeding, 4 to 6 weeks after breeding, 4 to 6 weeks before farrowing, and just before farrowing, there were no adverse effects. Transient salivation was noticed in five sows after treatment. In 4 groups of 4 sows each given levamisole gel orally to provide 8, 24, 40, or 80 mg of levamisole HCl/kg, adverse clinical signs were not observed in sows treated with 8 mg/kg. Transient salivation was noticed in one sow given 24 mg/kg, two sows given 40 mg/kg, and four sows given 80 mg/kg. Multiple emesis and chomping occurred in one sow given 80 mg/kg. Levamisole residues in edible tissues from sows given 8 mg of levamisole gel/kg orally were less than 0.1 mg/kg of muscle and fat in sows killed on posttreatment day (PTD) 3 and less than 0.1 mg/kg of kidney in sows killed on PTD 5. Liver residues averaged 0.78 mg/kg in sows killed on PTD 3 and were reduced to 0.31 mg/kg in sows killed on PTD 5. The 99% upper tolerance limit with 95% confidence on the withdrawal time to assure levamisole residues of less than 0.10 mg/kg in liver tissue was 11 days.


Assuntos
Ascaríase/veterinária , Gastroenteropatias/veterinária , Levamisol/uso terapêutico , Esofagostomíase/veterinária , Doenças dos Suínos/parasitologia , Administração Oral , Animais , Ascaríase/tratamento farmacológico , Feminino , Gastroenteropatias/tratamento farmacológico , Gastroenteropatias/parasitologia , Géis , Levamisol/administração & dosagem , Levamisol/efeitos adversos , Levamisol/metabolismo , Esofagostomíase/tratamento farmacológico , Suínos , Doenças dos Suínos/tratamento farmacológico
15.
Rev Sci Instrum ; 85(11): 11D841, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430254

RESUMO

New phase space mapping and uncertainty analysis of energetic ion loss data in the DIII-D tokamak provides experimental results that serve as valuable constraints in first-principles simulations of energetic ion transport. Beam ion losses are measured by the fast ion loss detector (FILD) diagnostic system consisting of two magnetic spectrometers placed independently along the outer wall. Monte Carlo simulations of mono-energetic and single-pitch ions reaching the FILDs are used to determine the expected uncertainty in the measurements. Modeling shows that the variation in gyrophase of 80 keV beam ions at the FILD aperture can produce an apparent measured energy signature spanning across 50-140 keV. These calculations compare favorably with experiments in which neutral beam prompt loss provides a well known energy and pitch distribution.

16.
Rev Sci Instrum ; 85(11): 11E701, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430364

RESUMO

By arranging the particle first banana orbits to pass near a distant detector, the light ion beam probe (LIBP) utilizes orbital deflection to probe internal fields and field fluctuations. The LIBP technique takes advantage of (1) the in situ, known source of fast ions created by beam-injected neutral particles that naturally ionize near the plasma edge and (2) various commonly available diagnostics as its detector. These born trapped particles can traverse the plasma core on their inner banana leg before returning to the plasma edge. Orbital displacements (the forces on fast ions) caused by internal instabilities or edge perturbing fields appear as modulated signal at an edge detector. Adjustments in the q-profile and plasma shape that determine the first orbit, as well as the relative position of the source and detector, enable studies under a wide variety of plasma conditions. This diagnostic technique can be used to probe the impact on fast ions of various instabilities, e.g., Alfvén eigenmodes (AEs) and neoclassical tearing modes, and of externally imposed 3D fields, e.g., magnetic perturbations. To date, displacements by AEs and by externally applied resonant magnetic perturbation fields have been measured using a fast ion loss detector. Comparisons with simulations are shown. In addition, nonlinear interactions between fast ions and independent AE waves are revealed by this technique.

19.
Rev Sci Instrum ; 83(10): 10D707, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126881

RESUMO

A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities (≤500 kHz). Combined with the first FILD at ∼45° below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius r(L) ∼ [1.5-8] cm and pitch angle α ∼ [35°-85°]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.

20.
Ann R Coll Surg Engl ; 94(6): 411-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22943331

RESUMO

INTRODUCTION: Evidence suggests a clinical benefit with patch angioplasty after carotid endarterectomy (CEA). The UK National Vascular Database has demonstrated variation in practice but does not record technical details. This study was intended to define indications and technique of patching after CEA. METHODS: An electronic questionnaire was emailed to all 402 members of the Vascular Society of Great Britain and Ireland. The email could not be received by 23 and 14 did not perform CEA. Some questions allowed multiple answers. Fisher's exact test was used for statistical analysis. RESULTS: There were 187 responses (51%). Fifteen members (8%) performed eversion CEA, which obviates patching. Of all the respondents, 121 surgeons (65%) always use a patch. Seventy of these (58%) use the full patch width (median: 8 mm, range: 4-10 mm). Fourteen (12%) variably trimmed the patch (median: 7.5 mm, range: 5-10 mm) and 34 (28%) routinely trimmed (median: 6 mm, range: 3-20 mm). Selective patching, dependent on internal carotid artery diameter, was performed by 48 respondents (26%), 23 of whom specified a median artery threshold diameter of 5 mm (range: 3-8 mm). General anaesthesia was always or usually used by 83 surgeons (45%), local anaesthesia by 77 (41%) and the remainder followed patient choice. Obligatory patching is performed by 68 of the 83 respondents (82%) who prefer general anaesthesia whereas only 40 of the 77 surgeons (52%) who use local anaesthesia always patch (p<0.0001). CONCLUSIONS: There is a variable rate of patching after CEA in the UK, which appears dependent on the vessel size and mode of anaesthesia. There are also differences in the patch width adopted.


Assuntos
Angioplastia/métodos , Endarterectomia das Carótidas/métodos , Padrões de Prática Médica/estatística & dados numéricos , Anestesia Geral/estatística & dados numéricos , Anestesia Local/estatística & dados numéricos , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/estatística & dados numéricos , Humanos , Irlanda , Telas Cirúrgicas/estatística & dados numéricos , Inquéritos e Questionários , Técnicas de Sutura/estatística & dados numéricos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA