Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
BMC Cardiovasc Disord ; 22(1): 127, 2022 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-35337295

RESUMO

PURPOSE: Various parameters of mechanical dyssynchrony have been proposed to improve patient selection criteria for cardiac resynchronization therapy, but sensitivity and specificity are lacking. However, echocardiographic parameters are consistently investigated at rest, whereas heart failure (HF) symptoms predominately manifest during submaximal exertion. Although strain-based predictors of response are promising, feasibility and reproducibility during exercise has yet to be demonstrated. METHODS: Speckle-tracking echocardiography was performed in patients with HF at two separate visits. Echocardiography was performed at rest, during various exercise intensity levels, and during recovery from exercise. Systolic rebound stretch of the septum (SRSsept), systolic shortening, and septal discoordination index (SDI) were calculated. RESULTS: Echocardiography was feasible in about 70-80% of all examinations performed during exercise. Of these acquired views, 84% of the cine-loops were suitable for analysis of strain-based mechanical dyssynchrony. Test-retest variability and intra- and inter-operator reproducibility at 30% and 60% of the ventilatory threshold (VT) were about 2.5%. SDI improved in the majority of patients at 30% and 60% of the VT, with moderate to good agreement between both intensity levels. CONCLUSION: Although various challenges remain, exercise echocardiography with strain analysis appears to be feasible in the majority of patients with dyssynchronous heart failure. Inter- and intra-observer agreement of SRSsept and SDI up to 60% of the VT were comparable to resting values. During exercise, the extent of SDI was variable, suggesting a heterogeneous response to exercise. Further research is warranted to establish its clinical significance.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Ecocardiografia/métodos , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Reprodutibilidade dos Testes , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
2.
Artif Organs ; 44(8): E326-E336, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32242944

RESUMO

Left ventricular assist devices (LVAD) provide cardiac support to patients with advanced heart failure. Methods that can directly measure remaining LV function following device implantation do not currently exist. Previous studies have shown that a combination of loading (LV pressure) and deformation (strain) measurements enables quantitation of myocardial work. We investigated the use of ultrasound (US) strain imaging and pressure-strain loop analysis in LVAD-supported hearts under different hemodynamic and pump unloading conditions, with the aim of determining LV function with and without LVAD support. Ex vivo porcine hearts (n = 4) were implanted with LVADs and attached to a mock circulatory loop. Measurements were performed at hemodynamically defined "heart conditions" as the hearts deteriorated from baseline. Hemodynamic (including LV pressure) and radio-frequency US data were acquired during a pump-ramp protocol at speeds from 0 (with no pump outflow) to 10 000 revolutions per minute (rpm). Regional circumferential (εcirc ) and radial (εrad ) strains were estimated over each heart cycle. Regional ventricular dyssynchrony was quantitated through time-to-peak strain. Mean change in LV pulse pressure and εcirc between 0 and 10 krpm were -21.8 mm Hg and -7.24% in the first condition; in the final condition -46.8 mm Hg and -19.2%, respectively. εrad was not indicative of changes in pump speed or heart condition. Pressure-strain loops showed a degradation in the LV function and an increased influence of LV unloading: loop area reduced by 90% between 0 krpm in the first heart condition and 10 krpm in the last condition. High pump speeds and degraded condition led to increased dyssynchrony between the septal and lateral LV walls. Functional measurement of the LV while undergoing LVAD support is possible by using US strain imaging and pressure-strain loops. This can provide important information about remaining pump function. Use of novel LV pressure estimation or measurement techniques would be required for any future use in LVAD patients.


Assuntos
Coração Auxiliar , Animais , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Hemodinâmica , Suínos , Função Ventricular Esquerda/fisiologia
3.
Cardiovasc Ultrasound ; 18(1): 18, 2020 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-32471436

RESUMO

BACKGROUND: Exercise stress echocardiography is clinically used to assess cardiovascular diseases. For accurate cardiac evaluation, a stable field-of-view is required. However, transducer orientation and position are difficult to preserve. Hands-free acquisitions might provide more consistent and reproducible results. In this study, the field-of-view stability and variability of hands-free acquisitions are objectively quantified in a comparison with manually obtained images, based on image structural and feature similarities. In addition, the feasibility and consistency of hands-free strain imaging is assessed. METHODS: In twelve healthy males, apical and parasternal images were acquired hands-free, using a fixation device, and manually, during semi-supine exercise sessions. In the final ten seconds of every exercise period, the image structural similarity and cardiac feature consistency were computed using a steerable pyramid employing complex, oriented wavelets. An algorithm discarding images displaying lung artifacts was created. Hands-free strain consistency was analyzed. RESULTS: Hands-free acquisitions were possible in 9 of the 12 subjects, whereas manually 10 out of 12 could be imaged. The image structural similarity was significantly improved in the hands-free apical window acquisitions (0.91 versus 0.82), and at least equally good in the parasternal window (0.90 versus 0.82). The change in curvature and orientation of the interventricular septum also appeared to be lower in the hands-free acquisitions. The variability in field-of-view was similar in both acquisitions. Longitudinal, septal strain was shown to be at least as consistent when obtained hands-free compared to manual acquisitions. CONCLUSIONS: The field-of-view was shown to be more or equally stable and consistent in the hands-free data in comparison to manually obtained images. The variability was similar, thus respiration- and exercise-induced motions were comparable for manual and hands-free acquisitions. Additionally, the feasibility of hands-free strain has been demonstrated. Furthermore, the results suggest the hands-free measurements to be more reproducible, though further analysis is required.


Assuntos
Ecocardiografia/instrumentação , Teste de Esforço , Adulto , Algoritmos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
4.
Ultrasound Med Biol ; 48(9): 1785-1796, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35764454

RESUMO

Left ventricular (LV) strains are typically represented with respect to the imaging axes. Contraction within the myocardium occurs along myofibres, which vary in orientation. Therefore, a mismatch exists between the direction in which strain is calculated and that in which contraction occurs. In this study, ultrasound-based fibre orientation and 3-D strain estimation were combined to calculate the fibre-directional strain. Three-dimensional ultrasound volumes were created by simulating simple geometrical phantoms and a phantom based on a finite-element (FE) model of LV mechanics. Fibre-like structures were embedded within tissue-mimicking scatterers. Strains were applied to the numerical phantom, whereas the FE phantom was deformed based on the LV model. Fibre orientation was accurately estimated for both phantoms. There was poor agreement in axial and elevational strains (root mean square error = 29.9% and 12.3%), but good agreement in lateral and fibre-directional strains (root mean square error = 6.4% and 5.9% respectively), which aligned in the midwall. Simplifications to reduce computational complexity caused poor axial and elevational strain estimation. However, calculation of fibre-directional strain from single-modality ultrasound volumes was successful. Further studies, in ex vivo setups because of the fundamental limitations of currently available transducers, are needed to verify real-world performance of the method.


Assuntos
Ventrículos do Coração , Miocárdio , Simulação por Computador , Ventrículos do Coração/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia/métodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-35452387

RESUMO

Lightweight segmentation models are becoming more popular for fast diagnosis on small and low cost medical imaging devices. This study focuses on the segmentation of the left ventricle (LV) in cardiac ultrasound (US) images. A new lightweight model [LV network (LVNet)] is proposed for segmentation, which gives the benefits of requiring fewer parameters but with improved segmentation performance in terms of Dice score (DS). The proposed model is compared with state-of-the-art methods, such as UNet, MiniNetV2, and fully convolutional dense dilated network (FCdDN). The model proposed comes with a post-processing pipeline that further enhances the segmentation results. In general, the training is done directly using the segmentation mask as the output and the US image as the input of the model. A new strategy for segmentation is also introduced in addition to the direct training method used. Compared with the UNet model, an improvement in DS performance as high as 5% for segmentation with papillary (WP) muscles was found, while showcasing an improvement of 18.5% when the papillary muscles are excluded. The model proposed requires only 5% of the memory required by a UNet model. LVNet achieves a better trade-off between the number of parameters and its segmentation performance as compared with other conventional models. The developed codes are available at https://github.com/navchetanawasthi/Left_Ventricle_Segmentation.


Assuntos
Ventrículos do Coração , Processamento de Imagem Assistida por Computador , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Músculos , Ultrassonografia
6.
Med Eng Phys ; 74: 146-152, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31615731

RESUMO

Ultrasound-based 2D speckle-tracking echocardiography (US-2D-STE) is increasingly used to assess the functionality of the heart. In particular, the analysis of cardiac strain plays an important role in the identification of several cardiovascular diseases. However, this imaging technique presents some limitations associated with its operating principle that result in low accuracy and reproducibility of the measurement. In this study, an experimental framework for multimodal strain imaging in an in vitro porcine heart was developed. Specifically, the aim of this work was to analyse displacement and strain in the heart by means of 3D digital image correlation (3D-DIC) and US-2D-STE. Over a single cardiac cycle, displacement values obtained from the two techniques were in strong correlation, although systematically larger displacements were observed with 3D-DIC. Notwithstanding an absolute comparison of the strain measurements was not possible to achieve between the two methods, maximum principal strain directions computed with 3D-DIC were consistent with the longitudinal and circumferential strain distribution measured with US-2D-STE. 3D-DIC confirmed its high repeatability in quantifying displacement and strain over multiple cardiac cycles, unlike US-2D-STE which is affected by accumulated errors over time (i.e. drift). To conclude, this study demonstrates the potential of 3D-DIC to perform dynamic measurement of displacement and strain during heart deformations and supports future applications of this method in ex vivo beating heart platforms, which replicate more fully the complex contraction of the heart.


Assuntos
Ecocardiografia , Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Humanos , Software
7.
Ultrasound Med Biol ; 45(8): 2063-2074, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31060858

RESUMO

Recent studies have shown the efficacy of myocardial strain estimated using speckle tracking echocardiography (STE) in predicting response to cardiac resynchronisation therapy. This study focuses on circumferential strain patterns, comparing STE-acquired strains to tagged-magnetic resonance imaging (MRI-T). Second, the effect of regularisation was examined. Two-dimensional parasternal ultrasound (US) and MRI-T data were acquired in the left ventricular short-axis view of canines before (n = 8) and after (n = 9) left bunch branch block (LBBB) induction. US-based strain analysis was performed on Digital Imaging and Communications in Medicine data at the mid-level using three overall methods ("Commercial software," "Basic block-matching," "regularised block-matching"). Moreover, three regularisation approaches were implemented and compared. MRI-T analysis was performed using SinMod. Normalised regional circumferential strain curves, based on standard six or septal/lateral segments, were analysed and cross-correlated with MRI-T data. Systolic strain (SS) and septal rebound stretch (SRS) were calculated and compared. Overall agreement of normalised circumferential strain was good between all methods on a global and regional level. All STE methods showed a bias (≥4% strain) toward higher SS estimates. Pre-LBBB, septal and lateral segment correlation was excellent between the Basic (mean ρ = 0.96) and regularised (mean ρ = 0.97) methods and MRI-T. The Commercial method showed a significant discrepancy between the two walls (septal ρ = 0.94, lateral ρ = 0.68). Correlation with MRI-T reduced between pre- and post-LBBB (Commercial ρ = 0.79, Basic ρ = 0.82, mean regularised ρ = 0.86). Septal strain patterns and SRS varied with the STE software and type of regularisation, with all STE methods estimating non-zero SRS values pre-LBBB. Absolute values showed moderate agreement, with a bias for higher strain from STE. SRS varied with the type of software and extra regularisation applied. Open efforts are needed to understand the underlying causes of differences between STE methods before standardisation can be achieved. This is particularly important given the apparent clinical value of strain-based parameters such as SRS.


Assuntos
Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Cães , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Masculino , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
8.
Phys Med Biol ; 62(23): 9112-9126, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29053103

RESUMO

In recent years, novel ultrasound functional imaging (UFI) techniques have been introduced to assess cardiac function by measuring, e.g. cardiac output (CO) and/or myocardial strain. Verification and reproducibility assessment in a realistic setting remain major issues. Simulations and phantoms are often unrealistic, whereas in vivo measurements often lack crucial hemodynamic parameters or ground truth data, or suffer from the large physiological and clinical variation between patients when attempting clinical validation. Controlled validation in certain pathologies is cumbersome and often requires the use of lab animals. In this study, an isolated beating pig heart setup was adapted and used for performance assessment of UFI techniques such as volume assessment and ultrasound strain imaging. The potential of performing verification and reproducibility studies was demonstrated. For proof-of-principle, validation of UFI in pathological hearts was examined. Ex vivo porcine hearts (n = 6, slaughterhouse waste) were resuscitated and attached to a mock circulatory system. Radio frequency ultrasound data of the left ventricle were acquired in five short axis views and one long axis view. Based on these slices, the CO was measured, where verification was performed using flow sensor measurements in the aorta. Strain imaging was performed providing radial, circumferential and longitudinal strain to assess reproducibility and inter-subject variability under steady conditions. Finally, strains in healthy hearts were compared to a heart with an implanted left ventricular assist device, simulating a failing, supported heart. Good agreement between ultrasound and flow sensor based CO measurements was found. Strains were highly reproducible (intraclass correlation coefficients >0.8). Differences were found due to biological variation and condition of the hearts. Strain magnitude and patterns in the assisted heart were available for different pump action, revealing large changes compared to the normal condition. The setup provides a valuable benchmarking platform for UFI techniques. Future studies will include work on different pathologies and other means of measurement verification.


Assuntos
Coração/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Débito Cardíaco , Feminino , Coração/fisiologia , Hemodinâmica , Reprodutibilidade dos Testes , Estresse Fisiológico , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA