Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ultramicroscopy ; 225: 113268, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33892378

RESUMO

Here we demonstrate the use of nanofabricated grating holograms to diffract and shape electrons in a scanning electron microscope. The diffraction grating is placed in an aperture in the column. The entire diffraction pattern can be passed through the objective lens and projected onto the specimen, or an intermediate aperture can be used to select particular diffracted beams. We discuss several techniques for characterizing the diffraction pattern. The grating designs can incorporate features that can influence the phase and intensity of the diffracted SEM probe. We demonstrate this by producing electron vortex beams.

2.
Photobiomodul Photomed Laser Surg ; 37(2): 77-84, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31050928

RESUMO

Objective: This study explored the outcome of applying red/near-infrared light therapy using light-emitting diodes (LEDs) pulsed with three different frequencies transcranially to treat traumatic brain injury (TBI) in Veterans. Background: Photobiomodulation therapy (PBMT) using LEDs has been shown to have positive effects on TBI in humans and animal models. Materials and methods: Twelve symptomatic military Veterans diagnosed with chronic TBI >18 months post-trauma received pulsed transcranial PBMT (tPBMT) using two neoprene therapy pads containing 220 infrared and 180 red LEDs, generating a power output of 3.3 W and an average power density of 6.4 mW/cm2 for 20 min, thrice per week over 6 weeks. Outcome measures included standardized neuropsychological test scores and qualitative and quantitative single photon emission computed tomography (SPECT) measures of regional cerebral blood flow (rCBF). Results: Pulsed tPBMT significantly improved neuropsychological scores in 6 of 15 subscales (40.0%; p < 0.05; two tailed). SPECT analysis showed increase in rCBF in 8 of 12 (66.7%) study participants. Quantitative SPECT analysis revealed a significant increase in rCBF in this subgroup of study participants and a significant difference between pre-treatment and post-treatment gamma ray counts per cubic centimeter [t = 3.77, df = 7, p = 0.007, 95% confidence interval (95,543.21-21,931.82)]. This is the first study to report quantitative SPECT analysis of rCBF in regions of interest following pulsed tPBMT with LEDs in TBI. Conclusions: Pulsed tPBMT using LEDs shows promise in improving cognitive function and rCBF several years after TBI. Larger, controlled studies are indicated.


Assuntos
Lesões Encefálicas Traumáticas/radioterapia , Lesão Encefálica Crônica/radioterapia , Circulação Cerebrovascular/efeitos da radiação , Cognição/efeitos da radiação , Terapia com Luz de Baixa Intensidade , Veteranos , Adulto , Lesões Encefálicas Traumáticas/fisiopatologia , Lesões Encefálicas Traumáticas/psicologia , Lesão Encefálica Crônica/fisiopatologia , Lesão Encefálica Crônica/psicologia , Estudos de Coortes , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Adulto Jovem
3.
Photomed Laser Surg ; 2018 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-30418082

RESUMO

OBJECTIVE: This study explored the outcome of applying red/near-infrared light therapy using light-emitting diodes (LEDs) pulsed with three different frequencies transcranially to treat traumatic brain injury (TBI) in Veterans. BACKGROUND: Photobiomodulation therapy (PBMT) using LEDs has been shown to have positive effects on TBI in humans and animal models. MATERIALS AND METHODS: Twelve symptomatic military Veterans diagnosed with chronic TBI >18 months post-trauma received pulsed transcranial PBMT (tPBMT) using two neoprene therapy pads containing 220 infrared and 180 red LEDs, generating a power output of 3.3 W and an average power density of 6.4 mW/cm2 for 20 min, thrice per week over 6 weeks. Outcome measures included standardized neuropsychological test scores and qualitative and quantitative single photon emission computed tomography (SPECT) measures of regional cerebral blood flow (rCBF). RESULTS: Pulsed tPBMT significantly improved neuropsychological scores in 6 of 15 subscales (40.0%; p < 0.05; two tailed). SPECT analysis showed increase in rCBF in 8 of 12 (66.7%) study participants. Quantitative SPECT analysis revealed a significant increase in rCBF in this subgroup of study participants and a significant difference between pre-treatment and post-treatment gamma ray counts per cubic centimeter [t = 3.77, df = 7, p = 0.007, 95% confidence interval (95,543.21-21,931.82)]. This is the first study to report quantitative SPECT analysis of rCBF in regions of interest following pulsed tPBMT with LEDs in TBI. CONCLUSIONS: Pulsed tPBMT using LEDs shows promise in improving cognitive function and rCBF several years after TBI. Larger, controlled studies are indicated.

4.
J Colloid Interface Sci ; 287(1): 114-20, 2005 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15914155

RESUMO

On the basis of the Einstein theory of viscosity of dispersion, a parameter, termed as solvation factor, is presented to evaluate the solvation degree of nanoscale particles dispersed in a liquid in this work. The value of the parameter is obtained through the measurements of relative viscosity of the dispersions as a function of the volume fraction of dry particles. The solvation factor has been used to study the hydration layers near nanoscale silica particles dispersed in water and aqueous electrolyte (NaCl and CaCl2) solutions in this work. The experimental results have shown that a strong hydration indeed applied to the silica surfaces in aqueous solutions, leaving a large volume of hydration layers on the surfaces. Also, it has been found that the hydration of the nanoscale silica particles could be greatly enhanced if they were dispersed in aqueous NaCl or CaCl2 solutions, which might be attributed to that the hydrated cations (Na+ or Ca2+) bind onto the silica/ water interface and thus increase the volume of the hydration layers.

5.
J Appl Behav Anal ; 15(3): 381-402, 1982.
Artigo em Inglês | MEDLINE | ID: mdl-16795658

RESUMO

Two studies were conducted in all-electric townhouses and apartments in the winter (N = 83) and summer (N = 54) to ascertain how energy conservation strategies focusing on thermostat change and set-backs and other low-cost/no-cost approaches would affect overall electricity use and electricity used for heating and cooling, the home thermal environment, the perceived comfort of participants, and clothing that was worn. The studies assessed the effectiveness of videotape modeling programs that demonstrated these conservation strategies when used alone or combined with daily feedback on electricity use. In the winter, the results indicated that videotape modeling and/or feedback were effective relative to baseline and to a control group in reducing overall electricity use by about 15% and electricity used for heating by about 25%. Hygrothermographs, which accurately and continuously recorded temperature and humidity in the homes, indicated that participants were able to live with no reported loss in comfort and no change in attire at a mean temperature of about 62 degrees F when home and about 59 degrees F when asleep. The results were highly discrepant with prior laboratory studies indicating comfort at 75 degrees F with the insulation value of the clothing worn by participants in this study. In the summer, a combination of strategies designed to keep a home cool with minimal or no air conditioning, in conjunction with videotape modeling and/or daily feedback, resulted in overall electricity reductions of about 15% with reductions on electricity for cooling of about 34%, but with feedback, and feedback and modeling more effective than modeling alone. Despite these electricity savings, hygrothermograph recordings indicated minimal temperature change in the homes, with no change in perceived comfort or clothing worn. The results are discussed in terms of discrepancies with laboratory studies, optimal combinations of video-media and personal contact to promote behavior change, and energy policies that may be mislabeled as sacrificial and underestimate the effectiveness of conservation strategies such as those investigated in these studies.

6.
Clin Chem ; 45(6 Pt 1): 777-84, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10351985

RESUMO

BACKGROUND: Amplified DNA probes provide powerful tools for the detection of infectious diseases, cancer, and genetic diseases. Commercially available amplification systems suffer from low throughput and require decontamination schemes, significant hands-on time, and specially trained laboratory staff. Our objective was to develop a DNA probe system to overcome these limitations. METHODS: We developed a DNA probe system, the BDProbeTecTMET, based on simultaneous strand displacement amplification and real-time fluorescence detection. The system uses sealed microwells to minimize the release of amplicons to the environment. To avoid the need for specially trained labor, the system uses a simple workflow with predispensed reagent devices; a programmable, expandable-spacing pipettor; and the 96-microwell format. Amplification and detection time was 1 h, with potential throughput up to 564 patient results per shift. We tested 122 total patient specimens obtained from a family practice clinic with the BD ProbeTecET and the Abbott LCx(R) amplified system for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae. RESULTS: Based on reportable results, the BDProbeTecET results for both organisms were 100% sensitive and 100% specific relative to the LCx. CONCLUSIONS: The BDProbeTecET is an easy-to-use, high-throughput, closed amplification system for the detection of nucleic acid from C. trachomatis and N. gonorrhoeae and other organisms.


Assuntos
Sondas de DNA , Amplificação de Genes , Chlamydia trachomatis/genética , DNA Bacteriano/análise , DNA Bacteriano/urina , Fluorescência , Humanos , Neisseria gonorrhoeae/genética , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA