Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Radiol Open ; 10: 100481, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36852255

RESUMO

Purpose: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition and the applicability of artificial intelligence (AI)-based coronary artery calcium scoring were assessed. Methods: In a clinical registry of 10481 patients undergoing heart and lung CT, GCCT was applied in 44 patients on a dual-source CT. Coronary calcium scans (CCS) with 120 kVp, 100 kVp, and tin-filtered 100 kVp (Sn100) of controls, matched with regard to age, sex, and body-mass index, were retrieved from the registry (ntotal=176, 66.5 (59.4-74.0) years, 52 men). Automatic tube current modulation was used in all scans. In 20 patients undergoing GCCT and Sn100 CCS, Agatston scores were measured both semi-automatically by experts and by AI, and classified into six groups (0, <10, <100, <400, <1000, ≥1000). Results: Effective dose decreased significantly from 120 kVp CCS (0.50 (0.41-0.61) mSv) to 100 kVp CCS (0.34 (0.26-0.37) mSv) to Sn100 CCS (0.14 (0.11-0.17) mSv). GCCT showed higher values (0.28 (0.21-0.32) mSv) than Sn100 CCS but lower than 120 kVp and 100 kVp CCS (all p < 0.05) despite greater scan length. Agatston scores correlated strongly between GCCT and Sn100 CCS in semi-automatic and AI-based measurements (both ρ = 0.98, p < 0.001) resulting in high agreement in Agatston score classification (κ = 0.97, 95% CI 0.92-1.00; κ = 0.89, 95% CI 0.79-0.99). Regarding chest findings, further diagnostic steps were recommended in 28 patients. Conclusions: GCCT allows for reliable coronary artery disease and lung cancer screening with ultra-low radiation exposure. GCCT-derived Agatston score shows excellent agreement with standard CCS, resulting in equivalent risk stratification.

2.
Diagnostics (Basel) ; 13(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38066814

RESUMO

As the number of coronary computed tomography angiography (CTA) examinations is expected to increase, technologies to optimize the imaging workflow are of great interest. The aim of this study was to investigate the potential of artificial intelligence (AI) to improve clinical workflow and diagnostic accuracy in high-volume cardiac imaging centers. A total of 120 patients (79 men; 62.4 (55.0-72.7) years; 26.7 (24.9-30.3) kg/m2) undergoing coronary CTA were randomly assigned to a standard or an AI-based (human AI) coronary analysis group. Severity of coronary artery disease was graded according to CAD-RADS. Initial reports were reviewed and changes were classified. Both groups were similar with regard to age, sex, body mass index, heart rate, Agatston score, and CAD-RADS. The time for coronary CTA assessment (142.5 (106.5-215.0) s vs. 195.0 (146.0-265.5) s; p < 0.002) and the total reporting time (274.0 (208.0-377.0) s vs. 350 (264.0-445.5) s; p < 0.02) were lower in the human AI than in the standard group. The number of cases with no, minor, or CAD-RADS relevant changes did not differ significantly between groups (52, 7, 1 vs. 50, 8, 2; p = 0.80). AI-based analysis significantly improves clinical workflow, even in a specialized high-volume setting, by reducing CTA analysis and overall reporting time without compromising diagnostic accuracy.

3.
BMJ Open ; 12(8): e058304, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35940836

RESUMO

OBJECTIVES: Since the safety of coronary CT angiography (CTA) is of great importance, especially with regard to widening indications and increasing morbidity, the aim of this study was to assess influencing factors. METHODS: Patients undergoing coronary CTA in a third-generation dual-source CT in a radiological centre were included in a clinical registry. Up to 20 mg metoprolol was administered intravenously to attain a heart rate ≤65/min. Glyceryl trinitrate (GTN) was administered in doses of 0.8 mg and 0.4 mg. Blood pressure was measured before the administration and after the CTA. RESULTS: Out of 5500 consecutive patients (3194 men, 62.3 (54.9-70.0) years), adverse events occurred in 68 patients (1.2%) with mild anaphylactoid reactions (0.4%), vasovagal symptoms (0.3%) and extravasation (0.3%) being most frequent. Anti-allergic drugs were given in 17 patients, atropine in 3 patients and volume in 1 patient. Drug administration resulted in a significant mean arterial pressure decline (96.0 (88.3-106.0) vs 108.7 (99.7-117.3) mmHg; p<0.001). Patients who suffered systolic blood pressure drops >20 mmHg or >40 mmHg were older (66.5 (58.6-73.3) vs 60.5 (53.6-68.3) years; 70.2 (63.3-76.5) vs 62.1 (54.7-69.6) years), more often male (65.1% vs 54.4%; 68.9% vs 57.3%) and had higher Agatston score equivalents (83.0 (2.0-432.0) vs 15.0 (0.0-172.0); 163.0 (16.3-830.8) vs 25.0 (0.0-220.0); all p<0.001). GTN dose reduction lowered the fraction of patients suffering from blood pressure drops >20 mmHg or >40 mmHg from 34.5% to 27.4% and from 6.1% to 3.5% (both p<0.001), respectively. The proportion of coronary segments with impaired image quality did not differ significantly. CONCLUSIONS: Coronary CTA with intravenous beta-blocker administration is a safe procedure in an outpatient setting as adverse events are rare and mostly mild. Reduced GTN doses can further improve safety by lowering the rate of significant blood pressure drops, which occurred especially in elderly men with increased plaque burden. TRIAL REGISTRATION NUMBER: NCT03815123.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Idoso , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Masculino , Nitroglicerina/efeitos adversos , Pacientes Ambulatoriais , Sistema de Registros , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
4.
Front Cardiovasc Med ; 8: 691665, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434975

RESUMO

Background: Coronary artery disease (CAD) shows a chronic but heterogeneous clinical course. Coronary CT angiography (CTA) allows for the visualization of the entire coronary tree and the detection of early stages of CAD. The aim of this study was to assess short-time changes in non-calcified and mixed plaques and their clinical impact using coronary CTA in a real-world setting. Methods: Between 11/2014 and 07/2019, 6,701 patients had a coronary CTA with a third-generation dual-source CT, of whom 77 patients (57 males, 63.8 ± 10.8 years) with a chronic CAD received clinically indicated follow-up CTA. Non-calcified and mixed plaques were analyzed in 1,211 coronary segments. Patients were divided into groups: stable, progressive, or regressive plaques. Results: Within the follow-up period of 22.3 ± 10.4 months, 44 patients (58%) showed stable plaques, 27 (36%) showed progression, 5 (7%) showed regression. One patient was excluded due to an undetermined CAD course showing both, progressive and regressive plaques. Age did not differ significantly between groups. Patients with plaque regression were predominantly female (80 vs. 20%), whereas patients showing progression were mainly male (85 vs. 15%; p < 0.01 for both). Regression was only observed in patients with mild CAD or one-vessel disease. The follow-up CTA led to changes in patient management in the majority of subjects (n = 50; 66%). Conclusions: Changes in coronary artery plaques can be observed within a short period resulting in an adjustment of the clinical management in the majority of CAD patients. Follow-up coronary CTA renders the non-invasive assessment of plaque development possible and allows for an individualized diagnostics and therapy optimization.

5.
Int J Cardiovasc Imaging ; 33(6): 879-888, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28138817

RESUMO

To assess the value of cardiac magnetic resonance imaging (CMR) in evaluating cardiac tumours in a tertiary cardiology centre. Between 2004 and 2014, 125 patients (pts.) from a total of 17000 who received a CMR examination in our institution were referred with the suspicion of cardiac tumours. A dedicated protocol was used that included standard cine SSFP acquisitions as well as tissue characterization using T1 and T2 black-blood (T1 BB and T2 BB respectively) with and without fat suppression, perfusion of the structure and late gadolinium enhancement. Patients' files were retrospectively analysed and data related to clinical status, results from other examinations (echocardiography), therapeutic approach and histology results, when performed, were collected. In 65 pts., a diagnosis of cardiac tumour was reached. 45 Pts had a biopsy. The CMR examination was concordant with the histology results in 35 (76%) pts. superior to that showed by echocardiography, 26 (58%) pts., p = 0.03. Forty-two (65%) pts. had a benign tumour and 23 (35%) a malignant process. Myxoma was the most frequent benign tumour, 27 (65%) and cardiac metastases were the most frequent form of malignancies, 21 (91%), with B cell non-Hodgkin lymphoma being the most frequent one, 4 (19%). Benign tumours were mostly located in the left atrium, 27 (64%) versus 6 (26%), p = 0.007, whereas malignant tumours had a predilection for the right atrium und left ventricle [11 (48%) vs. 3 (7%), p = 0.001 and 8 (35%) vs. 3 (7%), p = 0.03]. All benign cardiac tumours were single and did not show signs of infiltration. Conversely, malignant cardiac tumours were larger (43 ± 35 vs. 24 ± 16, p = 0.007) with a significant proportion (65%) showing myocardial infiltration. Pts with malignant cardiac tumours had a higher proportion of LGE (82 vs. 60%, p = 0.05) and exhibited more frequently an isointense signal in T1 BB images (78 vs. 61%, p = 0.04). Both groups showed similar proportion of perfusion and signal intensity in the T2 BB acquisitions (p = NS). CMR is a valuable tool in evaluating cardiac tumours, proving superior to echocardiography in establishing the type of cardiac tumour.


Assuntos
Serviço Hospitalar de Cardiologia , Neoplasias Cardíacas/diagnóstico por imagem , Hospitais com Alto Volume de Atendimentos , Imagem Cinética por Ressonância Magnética , Mixoma/diagnóstico por imagem , Centros de Atenção Terciária , Adulto , Idoso , Protocolos Clínicos , Meios de Contraste/administração & dosagem , Ecocardiografia , Feminino , Gadolínio DTPA/administração & dosagem , Neoplasias Cardíacas/patologia , Neoplasias Cardíacas/secundário , Neoplasias Cardíacas/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Mixoma/patologia , Mixoma/terapia , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Fatores de Tempo , Carga Tumoral
6.
J Cardiovasc Comput Tomogr ; 11(3): 213-220, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28314613

RESUMO

BACKGROUND: The aim of this study was to assess the potential for radiation dose reduction using knowledge-based iterative model reconstruction (K-IMR) algorithms in combination with ultra-low dose body mass index (BMI)-adapted protocols in coronary CT angiography (coronary CTA). METHODS: Forty patients undergoing clinically indicated coronary CTA were randomly assigned to two groups with BMI-adapted (I: <25.0 kg/m2, II: <28.0 kg/m2, III: <30.0 kg/m2, IV: ≥30.0 kg/m2) low dose (LD, I: 100kVp/75 mAs, II: 100kVp/100 mAs, III: 100kVp/150 mAs, IV: 120kVp/150 mAs, n = 20) or ultra-low dose (ULD, I: 100kVp/50 mAs, II: 100kVp/75 mAs, III: 100kVp/100 mAs, IV: 120kVp/100 mAs, n = 20) protocols. Prospectively-triggered coronary CTA was performed using a 256-MDCT with the lowest reasonable scan length. Images were generated with filtered back projection (FBP), a noise-reducing hybrid iterative algorithm (iD, levels 2/5) and K-IMR using cardiac routine (CR) and cardiac sharp settings, levels 1-3. RESULTS: Groups were comparable regarding anthropometric parameters, heart rate, and scan length. The use of ULD protocols resulted in a significant reduction of radiation exposure (0.7 (0.6-0.9) mSv vs. 1.1 (0.9-1.7) mSv; p < 0.02). Image quality was significantly better in the ULD group using K-IMR CR 1 compared to FBP, iD 2 and iD 5 in the LD group, resulting in fewer non-diagnostic coronary segments (2.4% vs. 11.6%, 9.2% and 6.1%; p < 0.05). CONCLUSIONS: The combination of K-IMR with BMI-adapted ULD protocols results in significant radiation dose savings while simultaneously improving image quality compared to LD protocols with FBP or hybrid iterative algorithms. Therefore, K-IMR allows for coronary CTA examinations with high diagnostic value and very low radiation exposure in clinical routine.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Bases de Conhecimento , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Índice de Massa Corporal , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
7.
Int J Cardiovasc Imaging ; 32(11): 1645-1655, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27535040

RESUMO

To compare the value of inversion recovery with on-resonant water suppression (IRON) to conventional T1-weighted (T1w) MRA and computed tomography angiography (CTA) for visualization of peripheral nitinol stents. We visualized 14 different peripheral nitinol stents in vitro both using Gadolinium (Gd) and ultrasmall superparamagnetic iron nanoparticles (USPIOs) for conventional T1w and IRON-MRA using clinical grade 1.5T MR scanner and iodinated contrast material for CTA using a 256-slice CT scanner. Parameter assessment included signal- and contrast-to-noise ratio (S/CNR), relative in-stent signal and artificial lumen narrowing. X-ray angiography served as gold standard for diameter assessment. Gd-enhanced IRON-MRA exhibited highest in-stent SNR and CNR values compared to conventional T1w MRA (IRON (Gd/USPIO): SNR = 30 ± 3/21 ± 2, CNR = 23 ± 2/14 ± 1; T1w: SNR = 16 ± 1/14 ± 2, CNR = 12 ± 1/10 ± 1, all p < 0.05). Furthermore, IRON-MRA achieved highest relative in-stent signal both using Gd and USPIO (IRON (Gd/USPIO): 121 ± 8 %/103 ± 6 %; T1w: 73 ± 2 %/66 ± 4 %; CTA: 84 ± 6 %, all p < 0.05). However, artificial lumen narrowing appeared similar in all imaging protocols (IRON (Gd/USPIO): 21 ± 3 %/21 ± 2 %; T1w: 16 ± 4 %/17 ± 3 %; CTA: 19 ± 2 %, all p = NS). Finally, IRON-MRA provided improvement of the in-stent lumen visualization with an 'open-close-open' design, which revealed a complete in-stent signal loss in T1w MRA. IRON-MRA improves in-stent visualization in vitro compared to conventional T1w MRA and CTA. In light of the in vitro results with Gd-enhanced IRON-MRA, the clinical implementation of such an approach appears promising.


Assuntos
Ligas , Vasos Sanguíneos/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada Multidetectores , Stents , Artefatos , Meios de Contraste , Dextranos , Gadolínio DTPA , Iohexol/análogos & derivados , Nanopartículas de Magnetita , Modelos Anatômicos , Modelos Cardiovasculares , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA