Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38588025

RESUMO

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Estimativa de Kaplan-Meier , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Fatores de Risco , Alemanha
2.
J Biol Chem ; 300(5): 107255, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38579991

RESUMO

Myocardial failure is associated with adverse remodeling, including loss of cardiomyocytes, hypertrophy, and alterations in cell-cell contacts. Striatin-interacting phosphatase and kinase (STRIPAK) complexes and their mammalian STE20-like kinase 4 (Mst4) have been linked to development of different diseases. The role and targets of Mst4 in cardiomyocytes have not been investigated yet. Multitissue immunoblot experiments show highly enriched Mst4 expression in rodent hearts. Analyses of human biopsy samples from patients suffering from dilated cardiomyopathy revealed that Mst4 is upregulated (5- to 8-fold p < 0.001) compared with nonfailing controls. Increased abundance of Mst4 could also be detected in mouse models of cardiomyopathy. We confirmed that Mst4 interacts with STRIPAK components in neonatal rat ventricular cardiomyocytes, indicating that STRIPAK is present in the heart. Immunofluorescence stainings and molecular interaction studies revealed that Mst4 is localized to the intercalated disc and interacts with several intercalated disc proteins. Overexpression of Mst4 in cardiomyocytes results in hypertrophy compared with controls. In adult rat cardiomyocytes, Mst4 overexpression increases cellular and sarcomeric fractional shortening (p < 0.05), indicating enhanced contractility. Overexpression of Mst4 also inhibits apoptosis shown by reduction of cleaved caspase3 (-69%, p < 0.0001), caspase7 (-80%, p < 0.0001), and cleaved Parp1 (-27%, p < 0.001). To elucidate potential Mst4 targets, we performed phosphoproteomics analyses in neonatal rat cardiomyocytes after Mst4 overexpression and inhibition. The results revealed target candidates of Mst4 at the intercalated disc. We identified Mst4 as a novel cardiac kinase that is upregulated in cardiomyopathy-regulating cardiomyocyte growth and survival.


Assuntos
Cardiomiopatias , Miócitos Cardíacos , Proteínas Serina-Treonina Quinases , Regulação para Cima , Animais , Humanos , Masculino , Camundongos , Ratos , Apoptose , Cardiomiopatias/enzimologia , Cardiomiopatias/genética , Cardiomiopatias/patologia , Cardiomiopatia Dilatada/metabolismo , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/genética , Proliferação de Células/genética , Sobrevivência Celular/genética , Miócitos Cardíacos/enzimologia , Miócitos Cardíacos/patologia , Proteínas Serina-Treonina Quinases/metabolismo , Proteínas Serina-Treonina Quinases/genética
3.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Assuntos
Estenose da Valva Aórtica , Benchmarking , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Idoso , Procedimentos Clínicos , Europa (Continente)/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Segurança do Paciente
4.
Cardiology ; 148(6): 556-570, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37442111

RESUMO

BACKGROUND: Elderly patients with aortic stenosis (AS) not only have a reduced life expectancy but also a reduced quality of life (QoL). The benefits of an AS intervention may be considered a balance between a good QoL and a reasonably extended life. However, the different questionnaires being used to determine the QoL were generally not developed for the specific situation of patients with AS and come with strengths and considerable weaknesses. The objective of this article was to provide an overview of the available QoL instruments in AS research, describe their strengths and weaknesses, and provide our assessment of the utility of the available scoring instruments for QoL measurements in AS. SUMMARY: We identified and reviewed the following instruments that are used in AS research: Short Form Health Survey (SF-36/SF-12), EuroQol-5D (EQ-5D), the Illness Intrusiveness Rating Scale (IIRS), the HeartQoL, the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Minnesota Living with Heart Failure Questionnaire (MLHF), the MacNew Questionnaire, and the Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ). KEY MESSAGES: There is no standardized assessment of QoL in patients with AS. Many different questionnaires are being used, but they are rarely specific for AS. There is a need for AS-specific research into the QoL of patients as life prolongation may compete for an improved QoL in this elderly patient group.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Humanos , Idoso , Qualidade de Vida , Inquéritos e Questionários
5.
BMC Cardiovasc Disord ; 23(1): 295, 2023 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-37301870

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) can either be conducted as an elective (scheduled in advance) or a non-elective procedure performed during an unplanned hospital admission. The objective of this study was to compare the outcomes of elective and non-elective TAVI patients. METHODS: This single-centre study included 512 patients undergoing transfemoral TAVI between October 2018 and December 2020; 378 (73.8%) were admitted for elective TAVI, 134 (26.2%) underwent a non-elective procedure. Our TAVI programme entails an optimized fast-track concept aimed at minimizing the total length of stay to ≤ 5 days for elective patients which in the German healthcare system is currently defined as the minimal time period to safely perform TAVI. Clinical characteristics and survival rates at 30 days and 1 year were analysed. RESULTS: Patients who underwent non-elective TAVI had a significantly higher comorbidity burden. Median duration from admission to discharge was 6 days (elective group 6 days versus non-elective group 15 days; p < 0.001), including a median postprocedural stay of 5 days (elective 4 days versus non-elective 7 days; p < 0.001). All-cause mortality at 30 days was 1.1% for the elective group and 3.7% for non-elective patients (p = 0.030). At 1 year, all-cause mortality among elective TAVI patients was disproportionately lower than in non-elective patients (5.0% versus 18.7%, p < 0.001). In the elective group, 54.5% of patients could not be discharged early due to comorbidities or procedural complications. Factors associated with a failure of achieving a total length of stay of ≤ 5 days comprised frailty syndrome, renal impairment as well as new permanent pacemaker implantation, new bundle branch block or atrial fibrillation, life-threatening bleeding, and the use of self-expanding valves. After multivariate adjustment, new permanent pacemaker implantation (odds ratio 6.44; 95% CI 2.59-16.00), life-threatening bleeding (odds ratio 4.19; 95% confidence interval 1.82-9.66) and frailty syndrome (odds ratio 5.15; 95% confidence interval 2.40-11.09; all p < 0.001, respectively) were confirmed as significant factors. CONCLUSIONS: While non-elective patients had acceptable periprocedural outcomes, mortality rates at 1 year were significantly higher compared to elective patients. Approximately only half of elective patients could be discharged early. Improvements in periprocedural care, follow-up strategies and optimized treatment of both elective and non-elective TAVI patients are needed.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Fragilidade , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Idoso Fragilizado , Universidades , Bloqueio de Ramo/etiologia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco , Próteses Valvulares Cardíacas/efeitos adversos
6.
Thorac Cardiovasc Surg ; 71(2): 118-120, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34176108

RESUMO

Transcatheter aortic valve replacement (TAVR) is routinely performed via the transfemoral or transapical route. Subclavian, transcarotid, and transaortic access are described as alternative routes for TAVR. The small intercostal approach can be used for a safe TAVR without touching the ribs and sternum.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
7.
Int J Mol Sci ; 24(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38139185

RESUMO

Transcatheter pulmonary valve replacement is a minimally-invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly evolving over the past years. Heart valve prostheses currently available still have major limitations. Therefore, one of the significant challenges for the future is the roll out of transcatheter tissue engineered pulmonary valve replacement to more patients. In the present study, biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds in the form of a 3D leaflet matrix were successfully seeded with human endothelial colony-forming cells (ECFCs), human induced pluripotent stem cell-derived MSCs (hMSCs), and porcine MSCs (pMSCs) for three weeks for the generation of 3D tissue-engineered tri-leaflet valved stent grafts. The cell adhesion, proliferation, and distribution of these 3D heart leaflets was analyzed using fluorescence microscopy and scanning electron microscopy (SEM). All cell lineages were able to increase the overgrown leaflet area within the three-week timeframe. While hMSCs showed a consistent growth rate over the course of three weeks, ECFSs showed almost no increase between days 7 and 14 until a growth spurt appeared between days 14 and 21. More than 90% of heart valve leaflets were covered with cells after the full three-week culturing cycle in nearly all leaflet areas, regardless of which cell type was used. This study shows that seeded biodegradable PCL nanofiber scaffolds incorporated in nitinol or biodegradable stents will offer a new therapeutic option in the future.


Assuntos
Células-Tronco Pluripotentes Induzidas , Poliésteres , Humanos , Animais , Suínos , Poliésteres/farmacologia , Engenharia Tecidual , Alicerces Teciduais , Stents
8.
Thorac Cardiovasc Surg ; 70(2): 126-132, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33540424

RESUMO

BACKGROUND: Mitral valved stents tend to migrate or to develop paravalvular leakage due to high-left ventricular pressure in this cavity. Thus, this study describes a newly developed mitral valved stent anchoring technology. METHODS: Based on an existing mitral valved stent, four anchoring units with curved surgical needles were designed and fabricated using three-dimensional (3D) software and print technology. Mitral nitinol stents assembled with four anchoring units were successively fixed on 10 porcine annuli. Mechanical tests were performed with a tensile force test system and recorded the tension forces of the 10 nitinol stents on the annulus. RESULTS: The average maximum force was 28.3 ± 5.21 N, the lowest was 21.7 N, and the highest was 38.6 N until the stent lost contact with the annulus; for the break force (zero movement of stent from annulus), the average value was 18.5 ± 6.7 N with a maximum value of 26.9 N and a minimum value of 6.07 N. It was additionally observed that the puncture needles of the anchoring units passed into the mitral annulus in all 10 hearts and further penetrated the myocardium in only one additional heart. The anchoring units enhanced the tightness of the mitral valved stent and did not destroy the circumflex coronary artery, coronary sinus, right atrium, aortic root, or the left ventricular outflow tract. CONCLUSION: The new anchoring units for mitral nitinol stents were produced with 3D software and printing technology; with this new type of anchoring technology, the mitral valved stent can be tightly fixed toward the mitral annulus.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Animais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Stents , Suínos , Tecnologia , Resultado do Tratamento
9.
Eur Heart J ; 42(28): 2780-2792, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-34104945

RESUMO

AIMS: Increased shedding of extracellular vesicles (EVs)-small, lipid bilayer-delimited particles with a role in paracrine signalling-has been associated with human pathologies, e.g. atherosclerosis, but whether this is true for cardiac diseases is unknown. METHODS AND RESULTS: Here, we used the surface antigen CD172a as a specific marker of cardiomyocyte (CM)-derived EVs; the CM origin of CD172a+ EVs was supported by their content of cardiac-specific proteins and heart-enriched microRNAs. We found that patients with aortic stenosis, ischaemic heart disease, or cardiomyopathy had higher circulating CD172a+ cardiac EV counts than did healthy subjects. Cellular stress was a major determinant of EV release from CMs, with hypoxia increasing shedding in in vitro and in vivo experiments. At the functional level, EVs isolated from the supernatant of CMs derived from human-induced pluripotent stem cells and cultured in a hypoxic atmosphere elicited a positive inotropic response in unstressed CMs, an effect we found to be dependent on an increase in the number of EVs expressing ceramide on their surface. Of potential clinical relevance, aortic stenosis patients with the highest counts of circulating cardiac CD172a+ EVs had a more favourable prognosis for transcatheter aortic valve replacement than those with lower counts. CONCLUSION: We identified circulating CD172a+ EVs as cardiac derived, showing their release and function and providing evidence for their prognostic potential in aortic stenosis patients.


Assuntos
Vesículas Extracelulares , MicroRNAs , Infarto do Miocárdio , Humanos , Hipóxia , Miocárdio , Miócitos Cardíacos
10.
Int J Mol Sci ; 23(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35054905

RESUMO

Patients with the complex congenital heart disease (CHD) are usually associated with right ventricular outflow tract dysfunction and typically require multiple surgical interventions during their lives to relieve the right ventricular outflow tract abnormality. Transcatheter pulmonary valve replacement was used as a non-surgical, less invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly developing over the past years. Despite the current favorable results of transcatheter pulmonary valve replacement, many patients eligible for pulmonary valve replacement are still not candidates for transcatheter pulmonary valve replacement. Therefore, one of the significant future challenges is to expand transcatheter pulmonary valve replacement to a broader patient population. This review describes the limitations and problems of existing techniques and focuses on decellularized tissue engineering for pulmonary valve stenting.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Stents , Engenharia Tecidual , Animais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/normas , Ventrículos do Coração/fisiopatologia , Humanos , Prognóstico , Engenharia Tecidual/métodos , Resultado do Tratamento , Função Ventricular
11.
Int J Mol Sci ; 23(1)2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-35008953

RESUMO

Clinically used heart valve prostheses, despite their progress, are still associated with limitations. Biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds, as a matrix, were seeded with human endothelial colony-forming cells (ECFCs) and human induced-pluripotent stem cells-derived MSCs (iMSCs) for the generation of tissue-engineered heart valves. Cell adhesion, proliferation, and distribution, as well as the effects of coating PCL nanofibers, were analyzed by fluorescence microscopy and SEM. Mechanical properties of seeded PCL scaffolds were investigated under uniaxial loading. iPSCs were used to differentiate into iMSCs via mesoderm. The obtained iMSCs exhibited a comparable phenotype and surface marker expression to adult human MSCs and were capable of multilineage differentiation. EFCFs and MSCs showed good adhesion and distribution on PCL fibers, forming a closed cell cover. Coating of the fibers resulted in an increased cell number only at an early time point; from day 7 of colonization, there was no difference between cell numbers on coated and uncoated PCL fibers. The mechanical properties of PCL scaffolds under uniaxial loading were compared with native porcine pulmonary valve leaflets. The Young's modulus and mean elongation at Fmax of unseeded PCL scaffolds were comparable to those of native leaflets (p = ns.). Colonization of PCL scaffolds with human ECFCs or iMSCs did not alter these properties (p = ns.). However, the native heart valves exhibited a maximum tensile stress at a force of 1.2 ± 0.5 N, whereas it was lower in the unseeded PCL scaffolds (0.6 ± 0.0 N, p < 0.05). A closed cell layer on PCL tissues did not change the values of Fmax (ECFCs: 0.6 ± 0.1 N; iMSCs: 0.7 ± 0.1 N). Here, a successful two-phase protocol, based on the timed use of differentiation factors for efficient differentiation of human iPSCs into iMSCs, was developed. Furthermore, we demonstrated the successful colonization of a biodegradable PCL nanofiber matrix with human ECFCs and iMSCs suitable for the generation of tissue-engineered heart valves. A closed cell cover was already evident after 14 days for ECFCs and 21 days for MSCs. The PCL tissue did not show major mechanical differences compared to native heart valves, which was not altered by short-term surface colonization with human cells in the absence of an extracellular matrix.


Assuntos
Biopolímeros/química , Caproatos/química , Células Progenitoras Endoteliais/citologia , Valvas Cardíacas , Células-Tronco Pluripotentes Induzidas/citologia , Lactonas/química , Células-Tronco Mesenquimais/citologia , Engenharia Tecidual , Alicerces Teciduais , Animais , Técnicas de Cultura de Células , Diferenciação Celular , Células Cultivadas , Células Progenitoras Endoteliais/metabolismo , Matriz Extracelular , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Células-Tronco Mesenquimais/metabolismo , Nanofibras , Suínos , Alicerces Teciduais/química
12.
Circulation ; 142(22): 2095-2106, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33032450

RESUMO

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used to treat cardiogenic shock. However, VA-ECMO might hamper myocardial recovery. The Impella unloads the left ventricle. This study aimed to evaluate whether left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO was associated with lower mortality. METHODS: Data from 686 consecutive patients with cardiogenic shock treated with VA-ECMO with or without left ventricular unloading using an Impella at 16 tertiary care centers in 4 countries were collected. The association between left ventricular unloading and 30-day mortality was assessed by Cox regression models in a 1:1 propensity score-matched cohort. RESULTS: Left ventricular unloading was used in 337 of the 686 patients (49%). After matching, 255 patients with left ventricular unloading were compared with 255 patients without left ventricular unloading. In the matched cohort, left ventricular unloading was associated with lower 30-day mortality (hazard ratio, 0.79 [95% CI, 0.63-0.98]; P=0.03) without differences in various subgroups. Complications occurred more frequently in patients with left ventricular unloading: severe bleeding in 98 (38.4%) versus 45 (17.9%), access site-related ischemia in 55 (21.6%) versus 31 (12.3%), abdominal compartment in 23 (9.4%) versus 9 (3.7%), and renal replacement therapy in 148 (58.5%) versus 99 (39.1%). CONCLUSIONS: In this international, multicenter cohort study, left ventricular unloading was associated with lower mortality in patients with cardiogenic shock treated with VA-ECMO, despite higher complication rates. These findings support use of left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO and call for further validation, ideally in a randomized, controlled trial.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Internacionalidade , Choque Cardiogênico/mortalidade , Choque Cardiogênico/terapia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Choque Cardiogênico/diagnóstico , Resultado do Tratamento
13.
Basic Res Cardiol ; 116(1): 13, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33630168

RESUMO

Atrial fibrillation (AF) is associated with electrical remodeling, leading to cellular electrophysiological dysfunction and arrhythmia perpetuation. Emerging evidence suggests a key role for epigenetic mechanisms in the regulation of ion channel expression. Histone deacetylases (HDACs) control gene expression through deacetylation of histone proteins. We hypothesized that class I HDACs in complex with neuron-restrictive silencer factor (NRSF) determine atrial K+ channel expression. AF was characterized by reduced atrial HDAC2 mRNA levels and upregulation of NRSF in humans and in a pig model, with regional differences between right and left atrium. In vitro studies revealed inverse regulation of Hdac2 and Nrsf in HL-1 atrial myocytes. A direct association of HDAC2 with active regulatory elements of cardiac K+ channels was revealed by chromatin immunoprecipitation. Specific knock-down of Hdac2 and Nrsf induced alterations of K+ channel expression. Hdac2 knock-down resulted in prolongation of action potential duration (APD) in neonatal rat cardiomyocytes, whereas inactivation of Nrsf induced APD shortening. Potential AF-related triggers were recapitulated by experimental tachypacing and mechanical stretch, respectively, and exerted differential effects on the expression of class I HDACs and K+ channels in cardiomyocytes. In conclusion, HDAC2 and NRSF contribute to AF-associated remodeling of APD and K+ channel expression in cardiomyocytes via direct interaction with regulatory chromatin regions. Specific modulation of these factors may provide a starting point for the development of more individualized treatment options for atrial fibrillation.


Assuntos
Potenciais de Ação , Fibrilação Atrial/enzimologia , Epigênese Genética , Átrios do Coração/enzimologia , Frequência Cardíaca , Histona Desacetilase 2/metabolismo , Miócitos Cardíacos/enzimologia , Canais de Potássio/metabolismo , Proteínas Repressoras/metabolismo , Adulto , Idoso , Animais , Fibrilação Atrial/genética , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Estudos de Casos e Controles , Linhagem Celular , Modelos Animais de Doenças , Feminino , Átrios do Coração/fisiopatologia , Histona Desacetilase 2/genética , Humanos , Masculino , Pessoa de Meia-Idade , Canais de Potássio/genética , Proteínas Repressoras/genética , Sus scrofa , Fatores de Tempo
14.
J Biomed Sci ; 28(1): 33, 2021 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-33906663

RESUMO

The Ras homolog gene family member A (RhoA) is the founding member of Rho GTPase superfamily originally studied in cancer cells where it was found to stimulate cell cycle progression and migration. RhoA acts as a master switch control of actin dynamics essential for maintaining cytoarchitecture of a cell. In the last two decades, however, RhoA has been coined and increasingly investigated as an essential molecule involved in signal transduction and regulation of gene transcription thereby affecting physiological functions such as cell division, survival, proliferation and migration. RhoA has been shown to play an important role in cardiac remodeling and cardiomyopathies; underlying mechanisms are however still poorly understood since the results derived from in vitro and in vivo experiments are still inconclusive. Interestingly its role in the development of cardiomyopathies or heart failure remains largely unclear due to anomalies in the current data available that indicate both cardioprotective and deleterious effects. In this review, we aimed to outline the molecular mechanisms of RhoA activation, to give an overview of its regulators, and the probable mechanisms of signal transduction leading to RhoA activation and induction of downstream effector pathways and corresponding cellular responses in cardiac (patho)physiology. Furthermore, we discuss the existing studies assessing the presented results and shedding light on the often-ambiguous data. Overall, we provide an update of the molecular, physiological and pathological functions of RhoA in the heart and its potential in cardiac therapeutics.


Assuntos
Cardiopatias/fisiopatologia , Transdução de Sinais/fisiologia , Proteína rhoA de Ligação ao GTP/genética , Animais , Cardiopatias/genética , Humanos , Ratos , Proteína rhoA de Ligação ao GTP/metabolismo
15.
Catheter Cardiovasc Interv ; 97(5): 876-884, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32886851

RESUMO

OBJECTIVES: To investigate 4-year, post-transcatheter aortic valve implantation (TAVI) survival and predictors of survival by sex, in a real-world cohort that underwent transfemoral TAVI with SAPIEN 3 transcatheter heart valve. BACKGROUND: Previous TAVI investigations of first-generation devices demonstrated an early- to mid-term survival advantage in women compared with men. METHODS: SOURCE 3 (SAPIEN 3 Aortic Bioprosthesis European Outcome) is a post-approval, multicentre, observational registry. Patients (N = 1,694, 49.2% women, age 81.7 ± 6.7 years) with severe aortic stenosis and high surgical risk (logistic EuroSCORE 17.8%) underwent TAVI between 2014 and 2015. Kaplan-Meier event estimates were used to determine mortality by sex. Predictors of overall mortality were identified using a cox multivariate proportional hazard model. RESULTS: At 4 years, women had lower all-cause mortality than men (36.0 vs 39.7%; p = .0911; HR: 0.87 [95% CI: 0.75-1.02]). No difference was observed for cardiac mortality between women 24.2% and men 24.7% (p = .76; HR: 0.97 [95% CI: 0.79-1.19]). When adjusted for baseline characteristics (age, height, weight, NYHA functional class, renal insufficiency, EuroScore, and tricuspid regurgitation), sex had no impact on mortality. CONCLUSIONS: In this large, real-world cohort, all-cause mortality trended lower in women than men at 4 years post TAVI; however, several baseline factors, but not sex, were predictors of mortality. No difference between sexes was observed for cardiovascular mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
BMC Nephrol ; 22(1): 77, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33653283

RESUMO

BACKGROUND: Chronic kidney disease as well as acute kidney injury are associated with adverse outcomes after transcatheter aortic valve replacement (TAVR). However, little is known about the prognostic implications of an improvement in renal function after TAVR. METHODS: Renal improvement (RI) was defined as a decrease in postprocedural creatinine in µmol/l of ≥1% compared to its preprocedural baseline value. A propensity score representing the likelihood of RI was calculated to define patient groups which were comparable regarding potential confounders (age, sex, BMI, NYHA classification, STS score, log. EuroSCORE, history of atrial fibrillation/atrial flutter, pulmonary disease, previous stroke, CRP, creatinine, hsTNT and NT-proBNP). The cohort was stratified into 5 quintiles according to this propensity score and the survival time after TAVR was compared within each subgroup. RESULTS: Patients in quintile 5 (n = 93) had the highest likelihood for RI. They were characterized by higher creatinine, lower eGFR, higher NYHA class, higher NT-proBNP, being mostly female and having shorter overall survival time. Within quintile 5, patients without RI had significantly shorter survival compared to patients with RI (p = 0.002, HR = 0.32, 95% CI = [0.15-0.69]). There was no survival time difference between patients with and without RI in the whole cohort (p = 0.12) and in quintiles 1 to 4 (all p > 0.16). Analyses of specific subgroups showed that among patients with NYHA class IV, those with RI also had a significant survival time benefit (p < 0.001, HR = 0.15; 95%-CI = [0.05-0.44]) compared to patients without RI. CONCLUSIONS: We here describe a propensity score-derived specific subgroup of patients in which RI after TAVR correlated with a significant survival benefit.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Síndrome Cardiorrenal/fisiopatologia , Rim/fisiopatologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Síndrome Cardiorrenal/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Pontuação de Propensão , Taxa de Sobrevida , Resultado do Tratamento
17.
Int J Mol Sci ; 22(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34681711

RESUMO

Congenital heart disease (CHD) is one of the most common birth defects in humans, present in around 40% of newborns with Down's syndrome (DS). The SH3 domain-binding glutamic acid-rich (SH3BGR) gene, which maps to the DS region, belongs to a gene family encoding a cluster of small thioredoxin-like proteins sharing SH3 domains. Although its expression is confined to the cardiac and skeletal muscle, the physiological role of SH3BGR in the heart is poorly understood. Interestingly, we observed a significant upregulation of SH3BGR in failing hearts of mice and human patients with hypertrophic cardiomyopathy. Along these lines, the overexpression of SH3BGR exhibited a significant increase in the expression of hypertrophic markers (Nppa and Nppb) and increased cell surface area in neonatal rat ventricular cardiomyocytes (NRVCMs), whereas its knockdown attenuated cellular hypertrophy. Mechanistically, using serum response factor (SRF) response element-driven luciferase assays in the presence or the absence of RhoA or its inhibitor, we found that the pro-hypertrophic effects of SH3BGR are mediated via the RhoA-SRF axis. Furthermore, SH3BGR knockdown resulted in the induction of apoptosis and reduced cell viability in NRVCMs via apoptotic Hippo-YAP signaling. Taking these results together, we here show that SH3BGR is vital for maintaining cytoskeletal integrity and cellular viability in NRVCMs through its modulation of the SRF/YAP signaling pathways.


Assuntos
Apoptose , Proteínas Musculares/genética , Actinina/metabolismo , Animais , Animais Recém-Nascidos , Células Cultivadas , Ventrículos do Coração/citologia , Via de Sinalização Hippo , Proteínas Musculares/deficiência , Proteínas Musculares/metabolismo , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Ratos , Fator de Resposta Sérica/genética , Fator de Resposta Sérica/metabolismo , Proteínas de Sinalização YAP/metabolismo , Proteína rhoA de Ligação ao GTP/antagonistas & inibidores , Proteína rhoA de Ligação ao GTP/metabolismo
18.
Thorac Cardiovasc Surg ; 68(2): 124-130, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-29975967

RESUMO

BACKGROUND: The impact of patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) on long-term survival and quality of life (QoL) remains controversial. The objective of this study was to evaluate the impact of PPM on long-term survival and QoL in a large cohort of patients treated with isolated stented biological AVR in a single-center experience. METHODS: We analyzed data of 632 consecutive patients following isolated stented biological AVR between 2007 and 2012 at our institution. We evaluated the QoL (393 evaluable patients) using the Short Form 12-item Health Survey (SF-12) questionnaire via telephone call and the impact of PPM on long-term survival (533 evaluable patients) by Kaplan-Meier's estimate. RESULTS: Severe PPM (<0.65 cm2/m2) had a negative impact on physical component summary (PCS) score (SF-12) compared with patients with moderate or no PPM (p = 0.014), while the mental component summary (MCS) score (SF-12) was not affected by the degree of PPM (p = 0.133). Long-term survival was not different among the three different PPM groups investigated (p = 0.75). CONCLUSION: Severity of PPM demonstrated no influence on long-term survival and MCS score (SF-12), but it was associated with a lower PCS score (SF-12) in patients with severe PPM.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
19.
Int Heart J ; 61(4): 713-719, 2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32684591

RESUMO

Differences in the benefits of conscious sedation (CS) and general anesthesia (GA) during transfemoral aortic valve implantation (TAVI) are unclear.We aimed to assess differences in procedural and clinical outcomes based on the type of anesthesia received during TAVI.We analyzed SOURCE 3 Registry data for patients who received the SAPIEN 3 valve by type of anesthesia used during TAVI.Of the 1694 TAVI patients, 1027 received CS and 667 received GA. Patients were similar at baseline (81.5 years; Society of Thoracic Surgeons risk score 7.0). Compared with the GA group, the CS group had fewer intra-procedural transesophageal echocardiography (TEE) and post implantation dilatations performed, and less contrast medium was used. The CS group had significantly less kidney injury at 7 days post-procedure than the GA group (0.4% versus 1.5%, P = 0.014). Moderate paravalvular leaks (PVL) occurred more frequently in the CS group versus the GA group (2.2% versus 0.8%; P = 0.041). No severe PVL were reported. Median total hospital length of stay (LOS) after TAVI was 10 days in the CS group and 11 days in the GS group. At 30 days, all-cause death was 2.1% in CS and 1.7% in GS (P = 0.47), and myocardial infarction was 0.2% in CS and 0.1% in GS (P = 0.83).Our analyses found no significant major outcome differences between CS and GA during TAVI.


Assuntos
Anestesia Geral/estatística & dados numéricos , Sedação Consciente/estatística & dados numéricos , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
20.
J Mol Cell Cardiol ; 129: 130-143, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30797814

RESUMO

Cardiac remodeling is induced by mechanical or humoral stress causing pathological changes to the heart. Here, we aimed at identifying the role of differentially regulated genes upon dynamic mechanical stretch. Microarray of dynamic stretch induced neonatal rat ventricular cardiomyocytes (NRVCMs) discovered Rho family GTPase 1 (Rnd1) as one of the significantly upregulated genes, a cardiac role of which is not known yet. Rnd1 was consistently upregulated in NRVCMs after dynamic stretch or phenylephrine (PE) stimulation, and in a mouse model of pressure overload. Overexpression of Rnd1 in NRVCMs activated the fetal gene program (including nppa and nppb) effected into a significant increase in cell surface area in untreated, stretched or PE-treated cells. Furthermore, Rnd1 overexpression showed a positive effect on cell proliferation as detected by significant increase in Ki67, Phosphohistone H3, and EdU positive NRVCMs. Through a Yeast two-hybrid screen and immunoprecipitation analysis, we identified Myozap, an intercalated disc protein, as novel interaction partner of Rnd1. Importantly, functional analysis of this interaction revealed the importance of RND1 in the RhoA and Myozap protein network that activates serum-response factor (SRF) signaling. In summary, we identified Rnd1 as a novel stretch-sensitive gene which influences cell proliferation and cellular hypertrophy via activation of RhoA-mediated SRF dependent and independent signaling pathways.


Assuntos
Cardiomegalia/metabolismo , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Estresse Fisiológico , Proteínas rho de Ligação ao GTP/metabolismo , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Ciclo Celular , Proliferação de Células , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Modelos Biológicos , Ligação Proteica , Ratos Wistar , Fator de Resposta Sérica/metabolismo , Transdução de Sinais , Proteína rhoA de Ligação ao GTP/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA