Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Water Sci Technol ; 43(8): 51-7, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11394279

RESUMO

In the first part of the paper, data from pilot plant studies are used to evaluate Cryptosporidium removal by dissolved air flotation (DAF) clarification and dual media filters under challenge conditions. Oocyst removals were investigated for design detention times and hydraulic loadings for winter and spring seasons. Coagulation was optimized for turbidity and removal of natural organic matter. DAF performance was better for spring water temperatures achieving 2.5 +/- 0.3 log removal of oocysts compared to 1.7 +/- 0.3 log removal in the winter. Cumulative log removal across DAF and filtration exceeded 5.4, and was not affected by water temperature. Low turbidities and particle counts are indicators of good treatment and good removals of Cryptosporidium. The second part of the paper uses a mathematical model to predict the fate of Cryptosporidium through a DAF plant and the impact of filter backwash recycle on oocyst build-up in the plant influent. Model predictions show that the fate of Cryptosporidium and the build-up of oocysts in the plant influent depend on: DAF performance, the percent of filtered water production used for backwashing, and the percent of filter backwash recycle flow. A DAF plant with 2.5% filtered water production for backwashing and that achieves 1.6 log removal or greater of oocysts by DAF clarification will not have a build-up of oocysts in the plant influent regardless of the recycle rate. This is because the oocysts are concentrated in the DAF floated sludge and not within granular filters.


Assuntos
Cryptosporidium/isolamento & purificação , Purificação da Água/métodos , Abastecimento de Água , Ar , Animais , Filtração/métodos , Projetos Piloto , Solubilidade
2.
Cathet Cardiovasc Diagn ; 44(3): 358-62, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9676814

RESUMO

The perfusion sleeve (PS) is an "over-the-balloon" catheter designed to add perfusion capability to standard PTCA catheters. To evaluate the clinical effectiveness of this device, eight patients underwent standard PTCA with the PS retracted in the guide (Inflation 1-Control) and after deployment of the PS (Inflation 3-Control). Between standard inflations the PS was advanced and aligned with the already positioned PTCA balloon which was inflated for up to 15 minutes (Inflation 2-Perfusion). TIMI III flow was present in 5/7 and TIMI II flow in 2/7 patients during Inflation 2-Perfusion. Absolute ST segment shift (mm) on the ECG was significantly less at 3 minutes and prior to balloon deflation with the PS in place (1.0 +/- 1.4 and 1.1 +/- 1.1 mm) compared to Inflation 1-Control and Inflation 3-Control (2.6 +/- 1.3 and 2.3 +/- 0.3 mm) respectively (P < or = 0.05). Use of the PS in conjunction with standard PTCA is feasible, provides perfusion during prolonged balloon inflations and reduces the magnitude of ischemia.


Assuntos
Angioplastia com Balão/instrumentação , Vasos Coronários , Perfusão/instrumentação , Idoso , Angina Pectoris/fisiopatologia , Angina Pectoris/terapia , Cineangiografia , Angiografia Coronária , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Eletrocardiografia , Desenho de Equipamento , Estudos de Avaliação como Assunto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA