Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Gut ; 63(9): 1481-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24717934

RESUMO

OBJECTIVE: Pancreatic cancer is a leading cause of cancer-related death in the Western world. Current chemotherapy regimens have modest survival benefit. Thus, novel, effective therapies are required for treatment of this disease. DESIGN: Activating KRAS mutation almost always drives pancreatic tumour initiation, however, deregulation of other potentially druggable pathways promotes tumour progression. PTEN loss leads to acceleration of Kras(G12D)-driven pancreatic ductal adenocarcinoma (PDAC) in mice and these tumours have high levels of mammalian target of rapamycin (mTOR) signalling. To test whether these KRAS PTEN pancreatic tumours show mTOR dependence, we compared response to mTOR inhibition in this model, to the response in another established model of pancreatic cancer, KRAS P53. We also assessed whether there was a subset of pancreatic cancer patients who may respond to mTOR inhibition. RESULTS: We found that tumours in KRAS PTEN mice exhibit a remarkable dependence on mTOR signalling. In these tumours, mTOR inhibition leads to proliferative arrest and even tumour regression. Further, we could measure response using clinically applicable positron emission tomography imaging. Importantly, pancreatic tumours driven by activated KRAS and mutant p53 did not respond to treatment. In human tumours, approximately 20% of cases demonstrated low PTEN expression and a gene expression signature that overlaps with murine KRAS PTEN tumours. CONCLUSIONS: KRAS PTEN tumours are uniquely responsive to mTOR inhibition. Targeted anti-mTOR therapies may offer clinical benefit in subsets of human PDAC selected based on genotype, that are dependent on mTOR signalling. Thus, the genetic signatures of human tumours could be used to direct pancreatic cancer treatment in the future.


Assuntos
Antineoplásicos/uso terapêutico , Biomarcadores Tumorais/antagonistas & inibidores , Carcinoma Ductal Pancreático/tratamento farmacológico , Neoplasias Pancreáticas/tratamento farmacológico , Inibidores de Proteínas Quinases/uso terapêutico , Sirolimo/uso terapêutico , Serina-Treonina Quinases TOR/antagonistas & inibidores , Animais , Biomarcadores Tumorais/metabolismo , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/genética , Carcinoma Ductal Pancreático/metabolismo , Linhagem Celular Tumoral , Esquema de Medicação , Regulação Neoplásica da Expressão Gênica , Humanos , Injeções Intraperitoneais , Camundongos , Camundongos Mutantes , Mutação , PTEN Fosfo-Hidrolase/deficiência , PTEN Fosfo-Hidrolase/genética , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/metabolismo , Tomografia por Emissão de Pósitrons , Proteínas Proto-Oncogênicas p21(ras)/deficiência , Proteínas Proto-Oncogênicas p21(ras)/genética , Serina-Treonina Quinases TOR/metabolismo , Resultado do Tratamento , Proteína Supressora de Tumor p53/deficiência , Proteína Supressora de Tumor p53/genética
2.
Scand J Gastroenterol ; 47(4): 387-96, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22339584

RESUMO

OBJECTIVE: Acid reflux produces troublesome symptoms (heartburn) and complications including esophagitis, Barrett's esophagus, and adenocarcinoma. Reflux occurs due to excessive and inappropriate relaxation of the lower esophageal sphincter. An important mediator of this is nitric oxide, high concentrations of which are generated within the lumen when swallowed saliva meets gastric acid. Saliva contains nitrite, derived from the enterosalivary recirculation of dietary nitrate, which is reduced to nitric oxide by gastric acid. The aim of this study was to investigate whether salivary nitrite contributes to dysfunction of the lower esophageal sphincter. MATERIALS AND METHODS: In 20 volunteers, studies of gastro-esophageal function were performed on four separate days, following consumption of a standardized meal, with saliva nitrite concentrations modified differently each day by intra-oral nitrite infusion. RESULTS: The infusions produced an appropriate range in saliva nitrite concentrations, from below to well above the physiological range. The standardized meal induced expected physiological changes in gastro-esophageal function confirming the recordings were sensitive and robust. Esophageal acid exposure (primary outcome) was similar on each study day. Secondary outcomes, including number and duration of reflux events, rate of transient lower esophageal sphincter relaxations, lower esophageal sphincter pressure and rate of gastric emptying were also unaffected by variations in saliva nitrite concentration. CONCLUSIONS: Nitrite in swallowed saliva does not modify gastro-esophageal junction function or predispose to gastro-esophageal reflux. The wide range in saliva nitrite concentrations, the sensitivity of the physiological recordings and the number of subjects studied make it very unlikely that an effect has been missed.


Assuntos
Esfíncter Esofágico Inferior/fisiologia , Nitritos/farmacologia , Saliva/química , Adulto , Esfíncter Esofágico Inferior/efeitos dos fármacos , Feminino , Esvaziamento Gástrico/efeitos dos fármacos , Esvaziamento Gástrico/fisiologia , Refluxo Gastroesofágico/induzido quimicamente , Humanos , Masculino , Manometria , Pessoa de Meia-Idade , Nitritos/efeitos adversos
3.
Phys Med Biol ; 64(24): 245013, 2019 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-31766032

RESUMO

The SEL-I-METRY trial (EudraCT No 2015-002269-47) is the first multicentre trial to investigate the role of 123I and 131I SPECT/CT-based tumour dosimetry to predict response to radioiodine therapy. Standardised dosimetry methodology is essential to provide a robust evidence-base for absorbed dose-response thresholds for molecular radiotherapy (MRT). In this paper a practical standardised protocol is used to establish the first network of centres with consistent methods of radioiodine activity quantification. Nine SPECT/CT systems at eight centres were set-up for quantitative radioiodine imaging. The dead-time of the systems was characterised for up to 2.8 GBq 131I. Volume dependent calibration factors were measured on centrally reconstructed images of 123I and 131I in six (0.8-196 ml) cylinders. Validation of image quantification using these calibration factors was performed on three systems, by imaging a 3D-printed phantom mimicking a patient's activity distribution. The percentage differences between the activities measured in the SPECT/CT image and those measured by the radionuclide calibrator were calculated. Additionally uncertainties on the SPECT/CT-based activities were calculated to indicate the limit on the quantitative accuracy of this method. For systems set-up to image high 131I count rates, the count rate versus activity did not peak below 2.8 GBq and fit a non-paralysable model. The dead-times and volume-dependent calibration factors were comparable between systems of the same model and crystal thickness. Therefore a global calibration curve could be fitted to each. The errors on the validation phantom activities' were comparable to the measurement uncertainties derived from uncertainty analysis, at 10% and 16% on average for 123I and 131I respectively in a 5 cm sphere. In conclusion, the dead-time and calibration factors varied between centres, with different models of system. However, global calibration factors may be applied to the same system model with the same crystal thickness, to simplify set-up of future multi-centre MRT studies.


Assuntos
Ensaios Clínicos como Assunto/normas , Estudos Multicêntricos como Assunto/normas , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Algoritmos , Calibragem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Radioisótopos do Iodo , Imagens de Fantasmas/normas , Impressão Tridimensional , Radiometria/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Phys Med Biol ; 61(3): 1259-77, 2016 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26788967

RESUMO

PET scans use overlapping acquisition beds to correct for reduced sensitivity at bed edges. The optimum overlap size for the General Electric (GE) Discovery 690 has not been established. This study assesses how image quality is affected by slice overlap. Efficacy of 23% overlaps (recommended by GE) and 49% overlaps (maximum possible overlap) were specifically assessed. European Association of Nuclear Medicine (EANM) guidelines for calculating minimum injected activities based on overlap size were also reviewed. A uniform flood phantom was used to assess noise (coefficient of variation, (COV)) and voxel accuracy (activity concentrations, Bq ml(-1)). A NEMA (National Electrical Manufacturers Association) body phantom with hot/cold spheres in a background activity was used to assess contrast recovery coefficients (CRCs) and signal to noise ratios (SNR). Different overlap sizes and sphere-to-background ratios were assessed. COVs for 49% and 23% overlaps were 9% and 13% respectively. This increased noise was difficult to visualise on the 23% overlap images. Mean voxel activity concentrations were not affected by overlap size. No clinically significant differences in CRCs were observed. However, visibility and SNR of small, low contrast spheres (⩽13 mm diameter, 2:1 sphere to background ratio) may be affected by overlap size in low count studies if they are located in the overlap area. There was minimal detectable influence on image quality in terms of noise, mean activity concentrations or mean CRCs when comparing 23% overlap with 49% overlap. Detectability of small, low contrast lesions may be affected in low count studies-however, this is a worst-case scenario. The marginal benefits of increasing overlap from 23% to 49% are likely to be offset by increased patient scan times. A 23% overlap is therefore appropriate for clinical use. An amendment to EANM guidelines for calculating injected activities is also proposed which better reflects the effect overlap size has on image noise.


Assuntos
Processamento de Imagem Assistida por Computador/normas , Tomografia por Emissão de Pósitrons/normas , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Guias de Prática Clínica como Assunto , Razão Sinal-Ruído
5.
Eur J Cancer ; 50(5): 944-52, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24445148

RESUMO

BACKGROUND: Single cycle carboplatin, dosed by glomerular filtration rate (GFR), is standard adjuvant therapy for stage 1 seminoma. Accurate measurement of GFR is essential for correct dosing. Isotopic methods remain the gold standard for the determination of GFR. Formulae to estimate GFR have improved the assessment of renal function in non-oncological settings. We assessed the utility of these formulae for carboplatin dosing. METHODS: We studied consecutive subjects receiving adjuvant carboplatin for stage 1 seminoma at our institution between 2007 and 2012. Subjects underwent 51Cr-ethylene diamine tetra-acetic acid (EDTA) measurement of GFR with carboplatin dose calculated using the Calvert formula. Theoretical carboplatin doses were calculated from estimated GFR using Chronic Kidney Disease-Epidemiology (CKD-EPI), Management of Diet in Renal Disease (MDRD) and Cockcroft-Gault (CG) formulae with additional correction for actual body surface area (BSA). Carboplatin doses calculated by formulae were compared with dose calculated by isotopic GFR; a difference <10% was considered acceptable. RESULTS: 115 patients were identified. Mean isotopic GFR was 96.9 ml/min/1.73 m(2). CG and CKD-EPI tended to overestimate GFR whereas MDRD tended to underestimate GFR. The CKD-EPI formula had greatest accuracy. The CKD-EPI formula, corrected for actual BSA, performed best; 45.9% of patients received within 10% of correct carboplatin dose. Patients predicted as underdosed (13.5%) by CKD-EPI were more likely to be obese (p=0.013); there were no predictors of the 40.5% receiving an excess dose. CONCLUSIONS: Our data support further evaluation of the CKD-EPI formula in this patient population but clinically significant variances in carboplatin dosing occur using non-isotopic methods of GFR estimation. Isotopic determination of GFR should remain the recommended standard for carboplatin dosing when accuracy is essential.


Assuntos
Carboplatina/uso terapêutico , Taxa de Filtração Glomerular , Seminoma/tratamento farmacológico , Neoplasias Testiculares/tratamento farmacológico , Adulto , Antineoplásicos/administração & dosagem , Antineoplásicos/farmacocinética , Antineoplásicos/uso terapêutico , Área Sob a Curva , Índice de Massa Corporal , Superfície Corporal , Carboplatina/administração & dosagem , Carboplatina/farmacocinética , Quelantes/administração & dosagem , Quelantes/farmacocinética , Relação Dose-Resposta a Droga , Ácido Edético/administração & dosagem , Ácido Edético/farmacocinética , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Insuficiência Renal Crônica/tratamento farmacológico , Insuficiência Renal Crônica/fisiopatologia , Seminoma/patologia , Neoplasias Testiculares/patologia
6.
Nucl Med Commun ; 33(8): 864-71, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22466066

RESUMO

OBJECTIVES: Attenuation correction algorithms are required for accurate quantification of PET data and for mapping of radioactive tracers. Modern PET systems incorporate computed tomography (CT) systems to perform attenuation correction. However, high-density media, such as contrast agents, may introduce potentially clinically significant artefacts in PET images when CT-based attenuation correction algorithms are used. Although various groups have investigated this issue, no study has quantitatively assessed the clinical significance of these artefacts by comparing artefact and lesion standardized uptake values (SUVs) in controlled phantom experiments. Furthermore, previous studies have focussed on the effects of increasing the concentration of contrast medium, without investigating the effects of increasing its transaxial area. This study quantifies the clinical significance of increasing the concentration and transaxial area of contrast agents and evaluates a commercially available contrast agent correction algorithm. METHODS: Images of a phantom containing background activity, a volume of contrast agent and varying sizes of hot lesions were acquired using clinical acquisition protocols. Quantitative analysis was performed on transaxial image slices of PET data. RESULTS: The densest medium caused a 125% SUV(mean) increase in the area containing, and immediately adjacent to, contrast medium when compared with a reference water phantom. As the transaxial area of the contrast medium increased, artefacts appeared as a ring of activity around the periphery of the contrast medium. The contrast correction algorithm reduced these artefacts to within ± 39% of the reference results. CONCLUSION: Oral and IV contrast agents can cause clinically significant artefacts in CT-based attenuation-corrected PET images and should be used with caution.


Assuntos
Algoritmos , Artefatos , Meios de Contraste/efeitos adversos , Aumento da Imagem/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Multimodal/instrumentação , Imagens de Fantasmas
7.
Nucl Med Commun ; 31(3): 254-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20032801

RESUMO

OBJECTIVE: Three-dimensional (3D) mode positron emission tomography (PET) is being used increasingly for clinical PET imaging. However, as yet, optimal acquisition parameters have not been established. The aim of this study was to investigate the effect of varying acquisition time on 3D image quality using standard clinical activities of F-fluorodeoxyglucose (FDG). METHODS: F-FDG phantom and patient PET images were acquired with varying acquisition times on a GE Discovery-STE PET/CT system. The NEMA Image-Quality phantom was imaged with four hot lesions in a uniform background. Images were acquired for 1, 2, 3, 4, and 5-min frames with three different lesion-to-background contrast ratios. Patient data were investigated using list mode acquisition to obtain comparable 2, 3, and 4-min frames. Qualitative analysis involved grading image quality and lesion detectability. Quantitative analysis of phantom images involved assessing the coefficient of variation (COV) of background areas as a measure of noise, and lesion over background variability as a measure of image quality. Patient data were also assessed using COV analysis of liver uptake. RESULTS: Qualitative and quantitative analysis showed no significant difference in image quality between 4 and 5-min acquisition frames for 3D mode F-FDG PET imaging with standard clinical activities. The observers noted no difference in perceived image quality. This finding was supported by COV analysis. CONCLUSION: This study shows that GE Discovery-STE acquisition frame time can be reduced to 3 min for standard 3D mode imaging at standard clinical activities of F-FDG.


Assuntos
Fluordesoxiglucose F18 , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Funções Verossimilhança , Masculino , Neoplasias/patologia , Imagens de Fantasmas , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA