Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 27(15): 21608-21621, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31510234

RESUMO

Coupled temperature and γ-ray influence on Brillouin (PPP-BOTDA) and Rayleigh (TW-COTDR) scatterings are quantified. Aging tests of these distributed strain measuring systems are performed on-line, up to 1 MGy, at room temperature, 80  ∘C, 100  ∘C and 120  ∘C. Brillouin and Rayleigh frequency shifts remain identical regardless of the temperature: 3 MHz (2 MHz) and 7 GHz (3 GHz) for Ge-doped (respectively F-doped) fiber at 1 MGy. Meanwhile, radiation-induced attenuation is diminished because of the higher temperature; hence, the maximal distance range is less deteriorated. These tests help to explain the origin of the Brillouin frequency shift under γ-rays, with an acoustic velocity variation of about 1 m/s in 1 MGy irradiated samples.

2.
Opt Lett ; 44(21): 5286-5289, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31674989

RESUMO

For some infrastructures such as oil and gas extraction boreholes or radioactive waste repositories, where distributed optical fiber sensors are employed to grant the safety of the facilities, the presence of gas species such as hydrogen or deuterium is one of the most relevant parameters to monitor. The possibility of employing the same kind of sensors for this purpose is of special interest, reducing the cost by employing a single interrogator, able to measure multiple parameters by simply employing adequate sensing fibers. To meet this goal, we present here a chemical sensor based on chirped-pulse phase-sensitive optical time-domain reflectometry (CP-φOTDR), which is able to detect these species while they diffuse into the silica fiber. The ability of chirped-pulse φOTDR to measure a change in refractive index with sensitivity around 10-8 has allowed determining hydrogen concentration with accuracy on the order of 10-3 mol/m3 and spatial resolution ∼6 m. Another experiment provides an indirect measurement of the solubility of deuterium in a standard telecom-grade optical fiber, which is found to be around 1.47×1024 m3/bar.

3.
Appl Opt ; 58(22): 6165-6172, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31503942

RESUMO

We studied the impact of ionizing radiation at high dose levels (megagray, MGy) on the photometric budget of a radiation-resistant complementary metal oxide semi-conductor (CMOS)-based camera. This is achieved by measuring the radiation-induced degradation of each subpart, namely its illumination system, its optical system, and its CMOS image sensor. The acquired experimental results allow performing a rather realistic simulation of the radiation effects at the system level. Thanks to appropriate mitigation techniques, limited image darkening and color change are obtained at MGy dose levels. The presented results confirm the feasibility of a CMOS-based camera able to resist to MGy dose level of ionizing radiations with an acceptable degradation of the image quality, opening the way to its implementation in the most challenging harsh environments.

4.
Regul Toxicol Pharmacol ; 94: 245-251, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29410076

RESUMO

Salicylic acid (SA) has a long history of safe use as ingredient in topical cosmetic products. In 2016, the Committee for Risk Assessment of the European Chemicals Agency proposed to classify SA as a Category 2 reproductive toxicant based on adverse developmental effects in animal toxicity studies. This hazard-based classification (based on mg/kg doses) requires a reassessment of the safety of the current SA concentrations in cosmetic consumer products. Herein, a safety reassessment was performed in which margins of safety were calculated based on literature data on the NOAEL plasma exposure levels from animal reproductive toxicity studies with ASA (rapidly converts to SA in plasma), human SA plasma levels from oral exposure to ASA and human dermal exposure to SA-containing cosmetic products. In addition, a literature review was performed, which shows that there are no adverse developmental effects despite extensive human clinical oral use of ASA up to the maximum recommended therapeutic doses. The plasma exposure-based safety assessment for SA combined with an absence of any clinical health risk with oral ASA use in the literature supports that there is an acceptable margin of safety for the consumer exposure to SA as authorized in the current EU cosmetic regulation.


Assuntos
Cosméticos/farmacocinética , Cosméticos/toxicidade , Exposição Materna , Ácido Salicílico/farmacocinética , Ácido Salicílico/toxicidade , Administração Oral , Administração Tópica , Animais , Disponibilidade Biológica , Qualidade de Produtos para o Consumidor , Feminino , Humanos , Macaca mulatta , Troca Materno-Fetal , Nível de Efeito Adverso não Observado , Gravidez , Ratos Wistar , Medição de Risco , Ácido Salicílico/sangue
5.
Nanotechnology ; 28(19): 195202, 2017 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-28345535

RESUMO

In this work we present an extensive investigation of nanoscale physical phenomena related to oxygen-deficient centers (ODCs) in silica and Ge-doped silica by means of first-principles calculations, including nudged-elastic band, electron paramagnetic resonance parameters calculations, and many-body perturbation theory (GW and Bethe-Salpeter equation) techniques. We show that by neutralizing positively charged oxygen monovacancies we can obtain model structures of twofold Si and Ge defects of which the calculated absorption spectra and singlet-to-triplet transitions are in excellent agreement with the experimental optical absorption and photo-luminescence data. In particular we provide an exhaustive analysis of the main exciton peaks related to the presence of twofold defects including long-range correlation effects. By calculating the reaction pathways and energy barriers necessary for the interconversion, we advance a double precursory origin of the [Formula: see text] and Ge(2) centers as due to the ionization of neutral oxygen monovacancies (Si-Si and Ge-Si dimers) and as due to the ionization of twofold Si and Ge defects. Furthermore two distinct structural conversion mechanisms are found to occur between the neutral oxygen monovacancy and the twofold Si (and Ge) atom configurations. Such conversion mechanisms allow to explain the radiation induced generation of the ODC(II) centers, their photobleaching, and also their generation during the drawing of optical fibers.

6.
Curr Oncol ; 23(6): e605-e614, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28050151

RESUMO

The annual Eastern Canadian Gastrointestinal Cancer Consensus Conference 2016 was held in Montreal, Quebec, 5-7 February. Experts in radiation oncology, medical oncology, surgical oncology, and infectious diseases involved in the management of patients with gastrointestinal malignancies participated in presentations and discussion sessions for the purpose of developing the recommendations presented here. This consensus statement addresses multiple topics: ■ Follow-up and survivorship of patients with resected colorectal cancer■ Indications for liver metastasectomy■ Treatment of oligometastases by stereotactic body radiation therapy■ Treatment of borderline resectable and unresectable pancreatic cancer■ Transarterial chemoembolization in hepatocellular carcinoma■ Infectious complications of antineoplastic agents.

7.
Opt Express ; 23(15): 18997-9009, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367563

RESUMO

Vulnerability of Optical Frequency Domain Reflectometry (OFDR) based sensors to high γ-ray doses (up to 10 MGy) is evaluated with a specific issue of a radiation-hardened temperature and strain monitoring system for nuclear industry. For this, we characterize the main radiation effects that are expected to degrade the sensor performances in such applicative domain: the radiation-induced attenuation (RIA), the possible evolution with the dose of the Rayleigh scattering phenomenon as well as its dependence on temperature and strain. This preliminary investigation is done after the irradiation and for five different optical fiber types covering the range from radiation-hardened fibers to highly radiation sensitive ones. Our results show that at these high dose levels the scattering mechanism at the basis of the used technique for the monitoring is unaffected (changes below 5%), authorizing acceptable precision on the temperature or strain measurements. RIA has to be considered as it limits the sensing range. From our vulnerability study, the OFDR sensors appear as promising candidates for nuclear industry even at doses as high as 10 MGy.

8.
Opt Lett ; 40(17): 4098-101, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26368721

RESUMO

Efficient operation of an Nd-doped fiber laser operating in a wavelength-tunable configuration using a volume Bragg grating (VBG) is reported in this Letter. A high-power operation on the 4F3/2-4I9/2 transition of Nd3+ at short wavelengths below 900 nm is demonstrated for the first time in silica fibers. A high-efficiency (47% laser conversion) output power up to 22 W and a narrow linewidth of 0.035 nm are achieved. This configuration is compared with a more conventional fiber laser setup using a bandpass filter and a highly reflective dichroic mirror.

9.
Opt Lett ; 40(20): 4571-4, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26469566

RESUMO

We investigate the radiation effects on germanosilicate optical fiber acting as the sensing element of optical frequency domain reflectometry devices. Thanks to a new setup permitting to control temperature during irradiation, we evaluate the changes induced by 10 keV x rays on their Rayleigh response up to 1 MGy in a temperature range from -40°C up to 75°C. Irradiation at fixed temperature points out that its measure is reliable during both irradiation and the recovery process. Mixed temperature and radiation measurements show that changing irradiation temperature leads to an error in distributed measurements that depends on the calibration procedure. These results demonstrate that Rayleigh-based optical fiber sensors are very promising for integration in harsh environments.

10.
Occup Med (Lond) ; 65(3): 238-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25759070

RESUMO

BACKGROUND: While there is a wide body of literature addressing noise-induced hearing loss (NIHL) and hand-arm vibration syndrome (HAVS) independently, relatively few studies have considered the combined effects of noise and vibration. These studies have suggested an increased risk of NIHL in workers with vibration white finger (VWF), though the relationship remains poorly understood. AIMS: To determine whether hearing impairment is worse in noise-exposed workers with VWF than in workers with similar noise exposures but without VWF. METHODS: The Quebec National Institute of Public Health audiometric database was used in conjunction with work-related accident and occupational diseases data from the Quebec workers' compensation board to analyse differences in audiometry results between vibration-exposed workers in the mining and forestry industries and the overall source population, and between mining and forestry workers with documented VWF and those without VWF. The International Organization for Standardization (ISO) 7029 standards were used to calculate hearing loss not attributable to age. RESULTS: 15751 vibration-exposed workers were identified in an overall source population of 59339. Workers with VWF (n = 96) had significantly worse hearing at every frequency studied (500, 1000, 2000 4000 Hz) compared with other mining and forestry workers without VWF. CONCLUSIONS: This study confirms previous findings of greater hearing loss at higher frequencies in workers with VWF, but also found a significant difference in hearing loss at low frequencies. It therefore supports the association between combined noise and hand-arm vibration (HAV) exposure and NIHL.


Assuntos
Perda Auditiva/etiologia , Ruído Ocupacional/efeitos adversos , Vibração/efeitos adversos , Audiometria , Perda Auditiva/epidemiologia , Humanos , Ruído Ocupacional/estatística & dados numéricos , Doenças Profissionais/epidemiologia , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/estatística & dados numéricos , Quebeque/epidemiologia , Indenização aos Trabalhadores
11.
Opt Lett ; 39(9): 2541-4, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24784040

RESUMO

We present a new structure for erbium-doped optical fibers [hole-assisted carbon-coated, (HACC)] that, combined with an appropriate choice of codopants in the core, strongly enhances their radiation tolerance. We built an erbium-doped fiber amplifier based on this HACC fiber and characterize its degradation under γ-ray doses up to 315 krad (SiO2) in the ON mode. The 31 dB amplifier is practically radiation insensitive, with a gain change of merely -2.2×10(-3) dB/krad. These performances authorize the use of HACC doped fibers and amplifiers for various applications in environments associated with today's missions (of doses up to 50 krad) and even for future space missions associated with higher dose constraints.

12.
Opt Lett ; 39(18): 5313-6, 2014 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26466259

RESUMO

We report a method for fabricating fiber Bragg gratings (FBG) resistant to very severe environments mixing high radiation doses (up to 3 MGy) and high temperatures (up to 230°C). Such FBGs have been written in two types of radiation resistant optical fibers (pure-silica and fluorine-doped cores) by exposures to a 800 nm femtosecond IR laser at power exceeding 500 mW and then subjected to a thermal annealing treatment of 15 min at 750°C. Under radiation, our study reveals that the radiation induced Bragg wavelength shift (BWS) at a 3 MGy dose is strongly reduced compared to responses of FBGs written with nonoptimized conditions. The BWS remains lower than 10 pm for temperatures of irradiation ranging from 25°C to 230°C without noticeable decrease of the FBG peak amplitude. For an applicative point of view, this radiation induced BWS corresponds to an additional error on the temperature measurements lower than 1.5°C, opening the way to the development of radiation-tolerant multi-point temperature sensors for nuclear industry.

13.
Mol Psychiatry ; 18(6): 721-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22889924

RESUMO

Tourette's syndrome (TS) is a developmental disorder that has one of the highest familial recurrence rates among neuropsychiatric diseases with complex inheritance. However, the identification of definitive TS susceptibility genes remains elusive. Here, we report the first genome-wide association study (GWAS) of TS in 1285 cases and 4964 ancestry-matched controls of European ancestry, including two European-derived population isolates, Ashkenazi Jews from North America and Israel and French Canadians from Quebec, Canada. In a primary meta-analysis of GWAS data from these European ancestry samples, no markers achieved a genome-wide threshold of significance (P<5 × 10(-8)); the top signal was found in rs7868992 on chromosome 9q32 within COL27A1 (P=1.85 × 10(-6)). A secondary analysis including an additional 211 cases and 285 controls from two closely related Latin American population isolates from the Central Valley of Costa Rica and Antioquia, Colombia also identified rs7868992 as the top signal (P=3.6 × 10(-7) for the combined sample of 1496 cases and 5249 controls following imputation with 1000 Genomes data). This study lays the groundwork for the eventual identification of common TS susceptibility variants in larger cohorts and helps to provide a more complete understanding of the full genetic architecture of this disorder.


Assuntos
Colágenos Fibrilares/genética , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla , Polimorfismo de Nucleotídeo Único/genética , Síndrome de Tourette/genética , Adolescente , Adulto , Transtorno do Deficit de Atenção com Hiperatividade/etiologia , Transtorno do Deficit de Atenção com Hiperatividade/genética , Estudos de Casos e Controles , Cromossomos Humanos Par 9/genética , Feminino , Genótipo , Humanos , Cooperação Internacional , Masculino , Metanálise como Assunto , Transtorno Obsessivo-Compulsivo/etiologia , Transtorno Obsessivo-Compulsivo/genética , Síndrome de Tourette/complicações , População Branca/genética , Adulto Jovem
14.
Pediatr Hematol Oncol ; 31(8): 743-53, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24308761

RESUMO

We report a retrospective analysis of Cytomegalovirus (CMV) infection: incidence, recurrence, resistance, and subsequent disease of 81 children who underwent allogenic hematopoietic stem cell transplantation (HSCT). The recipient and/or donor's CMV serology was positive prior to transplant [recipient (R+) and/or donor (D+)]. CMV was monitored by RT-PCR starting from the first week post transplant. Forty patients showed CMV infection (49, 5%). Of them 10 manifested CMV disease leading to four deaths. In univariate analysis, factors associated with CMV infection were CMV R+ P < .01, CMV R+/D+ pair P < .01, nonbone marrow (BM) stem cell source P < .05, nonirradiation conditioning regimen P < .05, Antithymocyte globulin (ATG) P < .01. Factors associated with CMV resistance were: >1 HLA allele mismatch P < .05, CMV R +/D-pair P < .01, CMV D-P < .01, non-BM P < .05, nongenoidentical transplant P < .01. CMV disease was influenced by >1 HLA allele mismatch (P < .001), non-BM (P < .01). On multivariate analysis, CMV R+/D- (P < .05), corticosteroids ≥2 mg/kg P < .01, ATG P < .01 and non-BM (P < .05) were independent factors for CMV infection. CMV R+ transplant is associated with more CMV infection and resistance to preemptive treatment. Prolonged immune suppression (IS) worsens outcome of CMV infection and should be shortened whenever possible.


Assuntos
Infecções por Citomegalovirus/epidemiologia , Infecções por Citomegalovirus/mortalidade , Transplante de Células-Tronco Hematopoéticas , Adolescente , Soro Antilinfocitário/administração & dosagem , Antivirais/uso terapêutico , Criança , Pré-Escolar , Infecções por Citomegalovirus/prevenção & controle , Feminino , Doença Enxerto-Hospedeiro/prevenção & controle , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Reação em Cadeia da Polimerase , Estudos Retrospectivos , Fatores de Risco , Condicionamento Pré-Transplante , Transplante Homólogo , Irradiação Corporal Total
15.
Opt Lett ; 38(16): 3065-7, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-24104649

RESUMO

We demonstrate a double-clad fiber laser operating at 910 nm with a record power of 20 W. Laser emission on the three-level scheme is enabled by the combination of a small inner cladding-to-core diameter ratio and a high brightness pump source at 808 nm. A laser conversion efficiency as high as 44% was achieved in CW operating regime by using resonant fiber Bragg reflectors at 910 nm that prevent the lasing at the 1060 nm competing wavelength. Furthermore, in a master oscillator power-amplifier scheme, an amplified power of 14.8 W was achieved at 914 nm in the same fiber.

16.
Exp Brain Res ; 224(2): 275-85, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23183636

RESUMO

Although the topic of sensory integration has raised increasing interest, the differing behavioral outcome of combining unisensory versus multisensory inputs has surprisingly only been scarcely investigated. In the present experiment, observers were required to respond as fast as possible to (1) lateralized visual or tactile targets presented alone, (2) double stimulation within the same modality or (3) double stimulation across modalities. Each combination was either delivered within the same hemispace (spatially aligned) or in different hemispaces (spatially misaligned). Results show that the redundancy gains (RG) obtained from the cross-modal conditions were far greater than those obtained from combinations of two visual or two tactile targets. Consistently, we observed that the reaction time distributions of cross-modal targets, but not those of within-modal targets, surpass the predicted reaction time distribution based on the summed probability distributions of each constituent stimulus presented alone. Moreover, we found that the spatial alignment of the targets did not influence the RG obtained in cross-modal conditions, whereas within-modal stimuli produced a greater RG when the targets where delivered in separate hemispaces. These results suggest that within-modal and cross-modal integration are not only distinguishable by the amount of facilitation they produce, but also by the spatial configuration under which this facilitation occurs. Our study strongly supports the notion that estimates of the same event that are more independent produce enhanced integrative gains.


Assuntos
Percepção Espacial/fisiologia , Tato/fisiologia , Percepção Visual/fisiologia , Adulto , Feminino , Humanos , Masculino , Modelos Biológicos , Estimulação Luminosa , Estimulação Física , Desempenho Psicomotor/fisiologia , Psicofísica , Tempo de Reação/fisiologia , Adulto Jovem
17.
Nano Lett ; 12(11): 5979-84, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-23072307

RESUMO

The morphology of crystalline precipitates in a solid-state matrix is governed by complex but tractable energetic considerations driven largely by volume strain energy minimization and anisotropy of interfacial energies. Spherical precipitate morphologies are favored by isotropic systems, while anisotropic interfacial energies give energetic preference to certain crystallographically oriented interfaces, resulting in a faceted precipitate morphology. In conventional solid-solution precipitation, a precipitate's morphological evolution is mediated by surface anchoring of capping molecules, which dramatically alter the surface energy in an anisotropic manner, thereby providing exquisite morphology control during crystal growth. Herein, we present experimental evidence and theoretical validation for the role of a ternary element (Na) in controlling the morphology of nanoscale PbS crystals nucleating in a PbTe matrix, an important bulk thermoelectric system. The PbS nanostructures formed by phase separation from a PbI(2)-doped or undoped PbTe matrix have irregular morphologies. However, replacing the iodine dopant with Na (1-2 mol %) alters dramatically the morphology of the PbS precipitates. Segregation of Na at PbTe/PbS interfaces result in cuboidal and truncated cuboidal morphologies for PbS. Using analytical scanning/transmission electron microscopy and atom-probe tomography, we demonstrate unambiguously that Na partitions to the precipitates and segregates at the matrix/precipitate interfaces, inducing morphological anisotropy of PbS precipitates. First-principles and semiclassical calculations reveal that Na as a solute in PbTe has a higher energy than in PbS and that Na segregation at a (100) PbTe/PbS interface decreases the total energy of matrix/precipitate system, resulting in faceting of PbS precipitates. These results provide an impetus for a new strategy for controlling morphological evolution in matrix/precipitate systems, mediated by solute partitioning of ternary additions.

18.
Nat Genet ; 28(1): 42-5, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11326273

RESUMO

Cytomegalovirus is the leading cause of congenital viral disease and the most important opportunistic infection in immunocompromised patients. We have used a mouse experimental infection model (MCMV) to study the genetic parameters of host/virus interaction. Susceptibility to infection with MCMV is controlled by Cmv1, a chromosome 6 locus that regulates natural killer (NK) cell activity against virally infected targets. Here, we use a positional cloning strategy to isolate the gene mutated at the Cmv1 locus. Cmv1 maps within a 0.35-cM interval defined by markers D6Ott8 and D6Ott115, which corresponds to a physical distance of 1.6 Mb (refs. 6-8). A transcript map of the region identified 19 genes, including members of the killer cell lectin-like receptor family a (Klra, formerly Ly49; refs. 9-12), which encode inhibitory or activating NK cell receptors that interact with MHC class I molecules. Klra genes have different copy numbers and genomic organization, and are highly polymorphic among inbred strains, making it difficult to distinguish between normal allelic variants and distinct Klra genes, or possible mutations associated with Cmv1. The recombinant inbred strain BXD-8/Ty (BXD-8; ref. 18), derived from Cmv1r C57BL/6 (B6, resistant) and Cmv1s DBA/2 (susceptible), is of particular interest because it is highly susceptible to MCMV infection despite having a B6 haplotype at Cmv1. We determined that MCMV susceptibility in BXD-8 is associated with the deletion of Klra8 (formerly Ly49h).


Assuntos
Antígenos Ly/genética , Infecções por Citomegalovirus/imunologia , Células Matadoras Naturais/imunologia , Glicoproteínas de Membrana/genética , Muromegalovirus/patogenicidade , Receptores Imunológicos/genética , Animais , Teste de Complementação Genética , Predisposição Genética para Doença , Lectinas/genética , Lectinas Tipo C , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos DBA , Dados de Sequência Molecular , Subfamília A de Receptores Semelhantes a Lectina de Células NK , Mapeamento Físico do Cromossomo , Receptores Semelhantes a Lectina de Células NK
19.
Opt Express ; 20(18): 20028-42, 2012 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-23037056

RESUMO

CMOS image sensors (CIS) are promising candidates as part of optical imagers for the plasma diagnostics devoted to the study of fusion by inertial confinement. However, the harsh radiative environment of Megajoule Class Lasers threatens the performances of these optical sensors. In this paper, the vulnerability of CIS to the transient and mixed pulsed radiation environment associated with such facilities is investigated during an experiment at the OMEGA facility at the Laboratory for Laser Energetics (LLE), Rochester, NY, USA. The transient and permanent effects of the 14 MeV neutron pulse on CIS are presented. The behavior of the tested CIS shows that active pixel sensors (APS) exhibit a better hardness to this harsh environment than a CCD. A first order extrapolation of the reported results to the higher level of radiation expected for Megajoule Class Laser facilities (Laser Megajoule in France or National Ignition Facility in the USA) shows that temporarily saturated pixels due to transient neutron-induced single event effects will be the major issue for the development of radiation-tolerant plasma diagnostic instruments whereas the permanent degradation of the CIS related to displacement damage or total ionizing dose effects could be reduced by applying well known mitigation techniques.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Lasers , Semicondutores , Transdutores , Desenho de Equipamento , Falha de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Sci Rep ; 12(1): 9223, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35654982

RESUMO

We report pump-probe transient absorption measurements addressing the photocycle of the Germanium lone pair center (GLPC) point defect with an unprecedented time resolution. The GLPC is a model point defect with a simple and well-understood electronic structure, highly relevant for several applications. Therefore, a full explanation of its photocycle is fundamental to understand the relaxation mechanisms of such molecular-like systems in solid state. The experiment, carried out exciting the sample resonantly with the ultraviolet (UV) GLPC absorption band peaked at 5.1 eV, gave us the possibility to follow the defect excitation-relaxation dynamics from the femto-picosecond to the nanosecond timescale in the UV-visible range. Moreover, the transient absorption signal was studied as a function of the excitation photon energy and comparative experiments were conducted on highly- and weakly-germanium doped silica glasses. The results offer a comprehensive picture of the relaxation dynamics of GLPC and allow observing the interplay between electronic transitions localized on the defect and those related to bandgap transitions, providing a clear evidence that the role of dopant high concentration is not negligible in the earliest dynamics.


Assuntos
Germânio , Fótons , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA