Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Pediatr Med Chir ; 36(5-6): 98, 2014 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-25669889

RESUMO

Anxiety in children undergoing surgery is characterized by feelings of tension, apprehension, nervousness and fear which may manifest differently. Postoperative behavioural changes such as nocturnal enuresis, feeding disorders, apathy, and sleep disturbances may stem from postoperative anxiety. Some Authors pointed out that over 60% of children undergoing surgery are prone to developing behavioural alterations 2 weeks after surgery. Variables such as age, temperament and anxiety both in children and parents are considered predictors of such changes.1 Studies were published describing how psycho-behavioural interventions based on play, learning and entertainment in preparing children for surgery, may reduce preoperative anxiety. Clown-therapy is applied in the most important paediatric facilities and has proved to diminish children's emotional distress and sufferance, as well as consumption of both analgesics and sedatives and to facilitate the achievement of therapeutic goals. The aim of our study was to evaluate the efficacy of clown-therapy during the child's hospital stay, with a view to optimizing treatment and care, preventing behavioural alterations and enhancing the child's overall life quality.


Assuntos
Ansiedade/prevenção & controle , Terapia do Riso/métodos , Cuidados Pré-Operatórios/métodos , Jogos de Vídeo/psicologia , Ansiedade/etiologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Qualidade de Vida
2.
Opt Express ; 20(17): 19382-94, 2012 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-23038581

RESUMO

An accurate control of the optical properties of single crystal diamond during microfabrication processes such as ion implantation plays a crucial role in the engineering of integrated photonic devices. In this work we present a systematic study of the variation of both real and imaginary parts of the refractive index of single crystal diamond, when damaged with 2 and 3 MeV protons at low-medium fluences (range: 10(15) - 10(17) cm(-2)). After implanting in 125 × 125 µm(2) areas with a scanning ion microbeam, the variation of optical pathlength of the implanted regions was measured with laser interferometric microscopy, while their optical transmission was studied using a spectrometric set-up with micrometric spatial resolution. On the basis of a model taking into account the strongly non-uniform damage profile in the bulk sample, the variation of the complex refractive index as a function of damage density was evaluated.


Assuntos
Diamante/química , Diamante/efeitos da radiação , Modelos Químicos , Refratometria/métodos , Simulação por Computador , Luz , Prótons , Espalhamento de Radiação
3.
Anal Bioanal Chem ; 401(3): 785-93, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21499950

RESUMO

Ion microbeam facilities are analytical tools with high spatial resolution exploiting MeV ion beams. The interactions of beam particles with atoms and nuclei of the target induce the emission of characteristic radiation, the energy of which provides signatures of the compositional and/or structural properties of the target; Ion-Beam Analysis (IBA) techniques, based on the detection of such radiation, enable characterisation of samples of interest, e.g. in material and earth sciences, cultural heritage, biology, medicine, and environmental studies. External beams, obtained by extracting the particles into the atmosphere through a thin window, have many attractive features, e.g. non-destructive/non-invasive analysis and ease of working, so many laboratories have dedicated beam-lines to ex-vacuo IBA analyses. External microprobes have made it possible to obtain probes in the micron range by adopting strong focusing lenses, ultra-thin windows for beam extraction, and short/ultra-short external path of beam particles in light gases; they have also made possible the use of new external IBA techniques, e.g. BS, ERDA, STIM, and IBIC. By adopting systems to raster scan the beam over the sample, imaging capabilities have also become available for ex-vacuo analysis. External scanning microprobes + IBA techniques have enabled the characterisation of samples with high spatial resolution, comparable with that achievable in-vacuum for thick samples, avoiding sample damage.

4.
Eur Phys J Plus ; 136(4): 472, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33968561

RESUMO

The LABEC laboratory, the INFN ion beam laboratory of nuclear techniques for environment and cultural heritage, located in the Scientific and Technological Campus of the University of Florence in Sesto Fiorentino, started its operational activities in 2004, after INFN decided in 2001 to provide our applied nuclear physics group with a large laboratory dedicated to applications of accelerator-related analytical techniques, based on a new 3 MV Tandetron accelerator. The new accelerator greatly improved the performance of existing Ion Beam Analysis (IBA) applications (for which we were using since the 1980s an old single-ended Van de Graaff accelerator) and in addition allowed to start a novel activity of Accelerator Mass Spectrometry (AMS), in particular for 14C dating. Switching between IBA and AMS operation became very easy and fast, which allowed us high flexibility in programming the activities, mainly focused on studies of cultural heritage and atmospheric aerosol composition, but including also applications to biology, geology, material science and forensics, ion implantation, tests of radiation damage to components, detector performance tests and low-energy nuclear physics. This paper describes the facilities presently available in the LABEC laboratory, their technical features and some success stories of recent applications.

5.
Phys Rev Lett ; 105(23): 233903, 2010 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-21231462

RESUMO

We demonstrate the feasibility of fabricating light-waveguiding microstructures in bulk single-crystal diamond by means of direct ion implantation with a scanning microbeam, resulting in the modulation of the refractive index of the ion-beam damaged crystal. Direct evidence of waveguiding through such buried microchannels is obtained with a phase-shift micro-interferometric method allowing the study of the multimodal structure of the propagating electromagnetic field. The possibility of defining optical and photonic structures by direct ion writing opens a range of new possibilities in the design of quantum-optical devices in bulk single-crystal diamond.

6.
Sci Rep ; 7(1): 385, 2017 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-28341859

RESUMO

Ion irradiation is a widely employed tool to fabricate diamond micro- and nano-structures for applications in integrated photonics and quantum optics. In this context, it is essential to accurately assess the effect of ion-induced damage on the variation of the refractive index of the material, both to control the side effects in the fabrication process and possibly finely tune such variations. Several partially contradictory accounts have been provided on the effect of the ion irradiation on the refractive index of single crystal diamond. These discrepancies may be attributable to the fact that in all cases the ions are implanted in the bulk of the material, thus inducing a series of concurrent effects (volume expansion, stress, doping, etc.). Here we report the systematic characterization of the refractive index variations occurring in a 38 µm thin artificial diamond sample upon irradiation with high-energy (3 MeV and 5 MeV) protons. In this configuration the ions are fully transmitted through the sample, while inducing an almost uniform damage profile with depth. Therefore, our findings conclusively identify and accurately quantify the change in the material polarizability as a function of ion beam damage as the primary cause for the modification of its refractive index.


Assuntos
Diamante/química , Diamante/efeitos da radiação , Fenômenos Ópticos , Óptica e Fotônica , Prótons , Refratometria
8.
Minerva Anestesiol ; 46(6): 675-80, 1980 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-7465082

RESUMO

An association of Althesin and Phentanyl succinylcholine is proposed as anaesthetic in patients with Parkinson's disease. This method has two advantages: it does not have an adverse effect on the drugs normally given to such patients, so that the postoperative neurological symptomatology is not altered in any way; its anesthetic effectiveness is allied with case of employment and a wide margin of safety.


Assuntos
Mistura de Alfaxalona Alfadolona , Anestesia , Fentanila , Doença de Parkinson , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Succinilcolina , Procedimentos Cirúrgicos Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA