Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 79: 324-334, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34648854

RESUMO

BACKGROUND: Fully absorbable polymeric scaffolds, as a potential alternative to permanent metallic stents, are entering the clinical field. The aim of this study is to assess the in vivo biocompatibility of a novel Sirolimus-eluting (SIR) absorbable scaffold based on poly(L-lactide) (PLLA) and poly(4-hydroxybutyrate) (P4HB) for interventional application. METHODS: Absorbable PLLA/P4HB scaffolds either loaded with SIR coating or unloaded scaffolds were implanted interventionally into common carotid arteries of 14 female. Bare metal stents (BMS) served as control. Peroral dual anti-platelet therapy was administered throughout the study. Stented common carotid arteries segments were explanted after 4 weeks, and assessed histomorphometrically. RESULTS: The absorbable scaffolds showed a decreased residual lumen area and higher stenosis after 4 weeks (PLLA/P4HB: 6.56 ± 0.41 mm² and 37.56 ± 4.67%; SIR-PLLA/P4HB: 6.90 ± 0.58 mm² and 35.60 ± 3.15%) as compared to BMS (15.29 ± 1.86 mm² and 7.65 ± 2.27%). Incorporation of SIR reduced the significantly higher inflammation of unloaded scaffolds however not to a level compared to bare metal stent (PLLA/P4HB: 1.20 ± 0.19; SIR-PLLA/P4HB: 0.96 ± 0.24; BMS: 0.54 ± 0.12). In contrast, the BMS showed a slightly elevated vascular injury score (0.74 ± 0.15), as compared to the PLLA/P4HB (0.54 ± 0.20) and the SIR-PLLA/P4HB (0.48 ± 0.15) groups. CONCLUSION: In this preclinical model, the new absorbable polymeric (SIR-) scaffolds showed similar technical feasability and safety for vascular application as the permanent metal stents. The higher inflammatory propensity of the polymeric scaffolds was slightly reduced by SIR-coating. A smaller strut thickness of the polymeric scaffolds might have been a positive effect on tissue ingrowth between the struts and needs to be addressed in future work on the stent design.


Assuntos
Implantes Absorvíveis , Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Artéria Carótida Primitiva/patologia , Poliésteres , Sirolimo/administração & dosagem , Angioplastia com Balão/efeitos adversos , Animais , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/etiologia , Estenose das Carótidas/patologia , Inflamação/etiologia , Inflamação/patologia , Teste de Materiais , Modelos Animais , Desenho de Prótese , Sus scrofa , Fatores de Tempo
2.
Molecules ; 27(4)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35209205

RESUMO

Cochlear implants, like other active implants, rely on precise and effective electrical stimulation of the target tissue but become encapsulated by different amounts of fibrous tissue. The current study aimed at the development of a dual drug release from a PLLA coating and from the bulk material to address short-term and long-lasting release of anti-inflammatory drugs. Inner-ear cytocompatibility of drugs was studied in vitro. A PLLA coating (containing diclofenac) of medical-grade silicone (containing 5% dexamethasone) was developed and release profiles were determined. The influence of different coating thicknesses (2.5, 5 and 10 µm) and loadings (10% and 20% diclofenac) on impedances of electrical contacts were measured with and without pulsatile electrical stimulation. Diclofenac can be applied to the inner ear at concentrations of or below 4 × 10-5 mol/L. Release of dexamethasone from the silicone is diminished by surface coating but not blocked. Addition of 20% diclofenac enhances the dexamethasone release again. All PLLA coatings serve as insulator. This can be overcome by using removable masking on the contacts during the coating process. Dual drug release with different kinetics can be realized by adding drug-loaded coatings to drug-loaded silicone arrays without compromising electrical stimulation.


Assuntos
Anti-Inflamatórios , Materiais Revestidos Biocompatíveis/química , Implantes Cocleares , Dexametasona , Diclofenaco , Sistemas de Liberação de Medicamentos , Animais , Anti-Inflamatórios/química , Anti-Inflamatórios/farmacocinética , Dexametasona/química , Dexametasona/farmacocinética , Diclofenaco/química , Diclofenaco/farmacocinética , Liberação Controlada de Fármacos , Ratos , Ratos Sprague-Dawley
3.
Int J Mol Sci ; 22(12)2021 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-34199303

RESUMO

The main purpose of new stent technologies is to overcome unfavorable material-related incompatibilities by producing bio- and hemo-compatible polymers with anti-inflammatory and anti-thrombogenic properties. In this context, wettability is an important surface property, which has a major impact on the biological response of blood cells. However, the influence of local hemodynamic changes also influences blood cell activation. Therefore, we investigated biodegradable polymers with different wettability to identify possible aspects for a better prediction of blood compatibility. We applied shear rates of 100 s-1 and 1500 s-1 and assessed platelet and monocyte activation as well as the formation of CD62P+ monocyte-bound platelets via flow cytometry. Aggregation of circulating platelets induced by collagen was assessed by light transmission aggregometry. Via live cell imaging, leukocytes were tracked on biomaterial surfaces to assess their average velocity. Monocyte adhesion on biomaterials was determined by fluorescence microscopy. In response to low shear rates of 100 s-1, activation of circulating platelets and monocytes as well as the formation of CD62P+ monocyte-bound platelets corresponded to the wettability of the underlying material with the most favorable conditions on more hydrophilic surfaces. Under high shear rates, however, blood compatibility cannot only be predicted by the concept of wettability. We assume that the mechanisms of blood cell-polymer interactions do not allow for a rule-of-thumb prediction of the blood compatibility of a material, which makes extensive in vitro testing mandatory.


Assuntos
Plaquetas/citologia , Comunicação Celular/efeitos dos fármacos , Monócitos/citologia , Monócitos/efeitos dos fármacos , Poliésteres/farmacologia , Plaquetas/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Agregação Plaquetária/efeitos dos fármacos , Água , Molhabilidade
4.
Int J Mol Sci ; 22(17)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34502107

RESUMO

Skin regeneration is a quite complex process. Epidermal differentiation alone takes about 30 days and is highly regulated. Wounds, especially chronic wounds, affect 2% to 3% of the elderly population and comprise a heterogeneous group of diseases. The prevailing reasons to develop skin wounds include venous and/or arterial circulatory disorders, diabetes, or constant pressure to the skin (decubitus). The hallmarks of modern wound treatment include debridement of dead tissue, disinfection, wound dressings that keep the wound moist but still allow air exchange, and compression bandages. Despite all these efforts there is still a huge treatment resistance and wounds will not heal. This calls for new and more efficient treatment options in combination with novel biocompatible skin scaffolds. Cold atmospheric pressure plasma (CAP) is such an innovative addition to the treatment armamentarium. In one CAP application, antimicrobial effects, wound acidification, enhanced microcirculations and cell stimulation can be achieved. It is evident that CAP treatment, in combination with novel bioengineered, biocompatible and biodegradable electrospun scaffolds, has the potential of fostering wound healing by promoting remodeling and epithelialization along such temporarily applied skin replacement scaffolds.


Assuntos
Gases em Plasma/química , Úlcera por Pressão/terapia , Alicerces Teciduais/química , Cicatrização , Animais , Humanos , Nanofibras/química , Úlcera por Pressão/patologia
5.
Electrophoresis ; 39(20): 2590-2597, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30025167

RESUMO

Simultaneous electrokinetic and hydrodynamic injection of rapamycin (sirolimus) with off-line and online sample preconcentration techniques and using MEKC has been studied. Compared to conventional hydrodynamic injection, a 168-fold improvement in the signal was obtained with a combination of simultaneous electrokinetic and hydrodynamic injectionand field enhanced sample injection in conjunction with a sweeping technique called sequential stacking featuring sweeping. However, the coupling of the developed electrophoretic method and solid-phase microextraction allowed the signal intensity to increase more than 231 times. In this approach, the injection of the sample at negative polarity (anode at the detector end) into the capillary and the MEKC separation was achieved within 5 min using an electrolyte (composed of 10 mM sodium tetraborate and 40 mM SDS) when ultraviolet (UV) detection was performed at 280 nm. Thus, by combining the application of the sequential stacking featuring sweeping supported by the solid-phase microextraction clean-up procedure, the detection limit (LOD) for rapamycin in a serum sample was significantly decreased, and was set at 25 ng/mL. The proposed combined simultaneous electrokinetic and hydrodynamic injection with field enhanced sample injection -sweeping technique following MEKC separation of sirolimus in human serum could be an effective tool in biomedical and clinical applications.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Sirolimo/sangue , Humanos , Limite de Detecção , Pressão , Microextração em Fase Sólida
6.
Klin Monbl Augenheilkd ; 235(12): 1360-1365, 2018 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-30566996

RESUMO

PURPOSE: Evaluation of the long-term efficiency of MIGS implants is still challenging, due to the lack of standardized clinical studies of stand-alone procedures. Moreover, the different mechanisms of the various glaucoma drainage devices are not adequately considered. The current study focusses on the development of a method for oculopression to evaluate the efficiency of glaucoma drainage devices. METHODS: Explanted porcine eyes were subjected to pressure or weight load using three oculopressors with different modi operandi. The time-dependent intraocular pressure was measured using an anterior chamber maintainer. The Honan Balloon exerts variable pressure onto the eye via an air bellows, whereas the Taylor oculopressor applies a defined weight loading on the eye. A novel oculopressor with a weight loading of 60 g was developed and manufactured by means of 3-D-printing. RESULTS: The intraocular pressure changes observed during the experiments were similar for all tested oculopression devices, varying only in the absolute pressure values. The Honan Balloon was not suitable for the intended purpose, due to poor standardisation of the applied pressure. Oculopression using a defined weight appeared more suitable. The Taylor oculopressor, however, created intraocular pressure values of up to 203.3 ± 38.4 mmHg, which precludes its use with glaucoma patients. On the basis of these data, the new oculopression device was used in a preliminary trial with healthy human subjects, thereby preparing its use in a clinical trial. CONCLUSIONS: Oculopression represents a potentially suitable tool to analyse the efficiency of glaucoma drainage devices. Commercially available oculopression devices are not directly applicable for this task. Difficult handling, high intraocular pressure, and lack of standardisation complicate the use for glaucoma patients. These difficulties were overcome with the newly designed oculopressor that facilitates a well defined increase in intraocular pressure. The device is currently being used in a clinical study to evaluate the efficiency of MIGS implants.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Animais , Câmara Anterior , Drenagem , Humanos , Pressão Intraocular , Suínos
7.
Biomed Microdevices ; 19(4): 78, 2017 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-28844120

RESUMO

Within this paper we analyzed the technical feasibility of a novel microstent for glaucoma therapy. For lowering of intraocular pressure, the flexible polyurethane (PUR) implant is designed to drain aqueous humour from the anterior chamber of the eye into subconjunctival, or alternatively suprachoroidal, space. The microstent includes a biodegradable, flow resisting polymer membrane serving as temporary flow resistance for the prevention of early postoperative hypotony. A biodegradable local drug delivery (LDD)-device was designed to prevent fibrous encapsulation. Biodegradable components were made of flexible, nonwoven membranes of Poly(4-hydroxybutyrate) (P(4HB)). Polymer samples and microstent prototypes were manufactured by means of dip coating, electrospinning and femtosecond-laser micromachining and characterized in vitro with regard to structural and fluid mechanical properties, degradation behavior and drug release. Bending stiffness of PUR-tubing (62.53 ± 7.57 mN mm2) is comparable to conventional glaucoma drainage devices in a tube-plate design. Microstent prototypes yield a flow resistance of 2.4 ± 0.6 mmHg/µl min-1 which is close to the aspired value corresponding to physiological pressure (15 mmHg) and aqueous humour flow (2 µl min-1) conditions inside the eye. Degradation of electrospun P(4HB) specimens was found to be almost completely finished after six months in vitro. Within this time frame, flow capacity of the microstent increases, which is beneficial to compensate potentially increasing flow resistance of fibrous tissue in vivo. Fast drug release of the LDD-device was found. One microstent prototype was implanted into a porcine eye ex vivo. Future preclinical studies will allow further information about Microstent performance.


Assuntos
Implantes Absorvíveis , Implantes de Medicamento , Glaucoma/terapia , Teste de Materiais , Poliésteres , Stents , Animais , Implantes de Medicamento/química , Implantes de Medicamento/farmacologia , Glaucoma/metabolismo , Glaucoma/fisiopatologia , Humanos , Poliésteres/química , Poliésteres/farmacologia , Suínos
8.
Heliyon ; 10(5): e26268, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38444474

RESUMO

Minimally invasive surgery procedures are of utmost relevance in clinical practice. However, the associated mechanical stress on the material poses a challenge for new implant developments. In particular PLLA, one of the most widely used polymeric biomaterials, is limited in its application due to its high brittleness and low elasticity. In this context, blending is a conventional method of improving the performance of polymer materials. However, in implant applications and development, material selection is usually limited to the use of medical grade polymers. The focus of this work was to investigate the extent to which blending poly-l-lactide (PLLA) with low contents of a selection of five commercially available medical grade polyurethanes leads to enhanced material properties. The materials obtained by melt blending were characterized in terms of their morphology and thermal properties, and the mechanical performance of the blends was evaluated taking into account physiological conditions. From these data, we found that mixing PLLA with Pellethane 80A is a promising approach to improve the material's performance, particularly for stent applications. It was found that PLLA/Pellethane blend with 10% polyurethane exhibits considerable plastic deformation before fracture, while pure PLLA fractures with almost no deformation. Furthermore, the addition of Pellethane only leads to a moderate reduction in elongation at yield and yield stress. In addition, dynamic mechanical analysis for three different PLLA/Pellethane ratios was performed to investigate thermally induced shape retention and shape recovery of the blends.

9.
Front Bioeng Biotechnol ; 12: 1367366, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38737540

RESUMO

Introduction: The biocompatibility of an implanted material strongly determines the subsequent host immune response. After insertion into the body, each medical device causes tissue reactions. How intense and long-lasting these are is defined by the material properties. The so-called foreign body reaction is a reaction leading to the inflammation and wound healing process after implantation. The constantly expanding field of implant technology and the growing areas of application make optimization and adaptation of the materials used inevitable. Methods: In this study, modified liquid silicone rubber (LSR) and two of the most commonly used thermoplastic polyurethanes (TPU) were compared in terms of induced inflammatory response in the body. We evaluated the production of inflammatory cytokines, infiltration of inflammatory cells and encapsulation of foreign bodies in a subcutaneous air-pouch model in mice. In this model, the material is applied in a minimally invasive procedure via a cannula and in one piece, which allows material testing without destroying or crushing the material and thus studying an intact implant surface. The study design includes short-term (6 h) and long-term (10 days) analysis of the host response to the implanted materials. Air-pouch-infiltrating cells were determined by flow cytometry after 6 h and 10 days. Inflammation, fibrosis and angiogenesis markers were analyzed in the capsular tissue by qPCR after 10 days. Results: The foreign body reaction was investigated by macroscopic evaluation and scanning electron microscopy (SEM). Increased leukocyte infiltration was observed in the air-pouch after 6 h, but it markedly diminished after 10 days. After 10 days, capsule formations were observed around the materials without visible inflammatory cells. Discussion: For biocompatibility testing materials are often implanted in muscle tissue. These test methods are not sufficiently conclusive, especially for materials that are intended to come into contact with blood. Our study primarily shows that the presented model is a highly adaptable and minimally invasive test system to test the inflammatory potential of and foreign body reaction to candidate materials and offers more precise analysis options by means of flow cytometry.

10.
Drug Deliv ; 31(1): 2361168, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38899440

RESUMO

Glaucoma is the leading cause of blindness worldwide. However, its surgical treatment, in particular via trabeculectomy, can be complicated by fibrosis. In current clinical practice, application of the drug, Mitomycin C, prevents or delays fibrosis, but can lead to additional side effects, such as bleb leakage and hypotony. Previous in silico drug screening and in vitro testing has identified the known antibiotic, josamycin, as a possible alternative antifibrotic medication with potentially fewer side effects. However, a suitable ocular delivery mechanism for the hydrophobic drug to the surgical site does not yet exist. Therefore, the focus of this paper is the development of an implantable drug delivery system for sustained delivery of josamycin after glaucoma surgery based on crosslinked γ-cyclodextrin. γ-Cyclodextrin is a commonly used solubilizer which was shown to complex with josamycin, drastically increasing the drug's solubility in aqueous solutions. A simple γ-cyclodextrin crosslinking method produced biocompatible hydrogels well-suited for implantation. The crosslinked γ - cyclodextrin retained the ability to form complexes with josamycin, resulting in a 4-fold higher drug loading efficiency when compared to linear dextran hydrogels, and prolonged drug release over 4 days.


Assuntos
Preparações de Ação Retardada , Hidrogéis , Solubilidade , gama-Ciclodextrinas , Hidrogéis/química , gama-Ciclodextrinas/química , Liberação Controlada de Fármacos , Sistemas de Liberação de Medicamentos/métodos , Glaucoma/tratamento farmacológico , Antibacterianos/administração & dosagem , Antibacterianos/química , Antibacterianos/farmacologia , Portadores de Fármacos/química , Animais , Humanos , Reagentes de Ligações Cruzadas/química
11.
J Mater Sci Mater Med ; 24(11): 2589-600, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23846839

RESUMO

Within the context of novel stent designs we developed a dual drug-eluting stent (DDES) with an abluminally focussed release of the potent anti-proliferative drug sirolimus and a luminally focussed release of atorvastatin with stabilizing effect on atherosclerotic deposits and stimulating impact on endothelial function, both from biodegradable poly(L-lactide)-based stent coatings. With this concept we aim at simultaneous inhibition of in-stent restenosis as a result of disproportionally increased smooth muscle cell proliferation and migration as well as thrombosis due to failed or incomplete endothelialisation. The especially adapted spray-coating processes allowed the formation of smooth form-fit polymer coatings at the abluminal and luminal side with 70% respectively 90% of the drug/polymer solution being deposited at the intended stent surface. The impacts of tempering, sterilization, and layer composition on drug release are thoroughly discussed making use of a semi-empirical model. While tempering at 80 °C seems to be necessary for the achievement of adequate and sustained drug release, the coating sequence for DDES should be rather abluminal-luminal than luminal-abluminal, as reduction of the amount of sirolimus eluted luminally could then potentially minimize the provocation of endothelial dysfunction. In vitro proliferation and viability assays with smooth muscle and endothelial cells underline the high potential of the developed DDES.


Assuntos
Stents Farmacológicos , Ácidos Heptanoicos/administração & dosagem , Pirróis/administração & dosagem , Sirolimo/administração & dosagem , Atorvastatina , Varredura Diferencial de Calorimetria , Proliferação de Células , Células Cultivadas , Ácidos Heptanoicos/farmacologia , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Peso Molecular , Pirróis/farmacologia , Sirolimo/farmacologia
12.
J Mech Behav Biomed Mater ; 140: 105720, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36801776

RESUMO

In the biomedical field, nanofiber materials are gaining increasing application. For material characterization of nanofiber fabrics, tensile testing and scanning electron microscopy (SEM) are established standards. However, tensile tests provide information about the entire sample without information about single fibers. Conversely, SEM images examine individual fibers, but cover only a small section near the surface of the sample. To gain information on failure at the fiber level under tensile stress, recording of acoustic emission (AE) is a promising method, but challenging due to weak signal intensity. Using AE recording, beneficial findings can be obtained even on "invisible" material failure without affecting tensile tests. In this work, a technology for recording weak ultrasonic AE of tearing nanofiber nonwovens is presented, which uses a highly sensitive sensor. Functional proof of the method using biodegradable PLLA nonwoven fabrics is provided. The potential benefit is demonstrated by unmasking significant AE intensity in an almost imperceptible bend in the stress-strain curve of a nonwoven fabric. AE recording has not yet been performed on standard tensile tests of unembedded nanofiber material intended for safety-related medical applications. The technology has the potential to enrich the spectrum of testing methods, even those not confined to medical field.


Assuntos
Nanofibras , Ultrassom , Microscopia Eletrônica de Varredura , Acústica , Têxteis
13.
Biomater Sci ; 11(15): 5240-5250, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37340971

RESUMO

Therapy for large-scale bone defects remains a major challenge in regenerative medicine. In this context, biodegradable electrospun nonwovens are a promising material to be applied as a temporary implantable scaffold as their fibre diameters are in the micro- and nanometre range and possess a high surface-to-volume ratio paired with high porosity. In this work, in vitro assessment of biodegradable PLLA-co-PEG nonwovens with fetuin A covalently anchored to the surface has been performed in terms of biomineralisation and the influence on MG-63 osteoblast cell metabolic activity, biosynthesis of type I collagen propeptide and inflammatory potential. Our finding was that covalent fetuin A funtionalisation of the nonwoven material leads to a distinct increase in calcium affinity, thus enhancing biomineralisation while maintaining the distinct fibre morphology of the nonwoven. The cell seeding experiments showed that the fetuin A functionalised and subsequently in vitro biomineralised PLLA-co-PEG nonwovens did not show negative effects on MG-63 growth. Fetuin A funtionalisation and enhanced biomineralisation supported cell attachment, leading to improved cell morphology, spreading and infiltration into the material. Furthermore, no signs of increase in the inflammatory potential of the material have been detected by flow cytometry experiments. Overall, this study provides a contribution towards the development of artificial scaffolds for guided bone regeneration with the potential to enhance osteoinduction and osteogenesis.


Assuntos
Engenharia Tecidual , alfa-2-Glicoproteína-HS , Poliésteres , Osteogênese , Ácido Láctico , Alicerces Teciduais
14.
Pharmaceutics ; 15(4)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37111525

RESUMO

Novel 3D printing techniques enable the development of medical devices with drug delivery systems that are tailored to the patient in terms of scaffold shape and the desired pharmaceutically active substance release. Gentle curing methods such as photopolymerization are also relevant for the incorporation of potent and sensitive drugs including proteins. However, retaining the pharmaceutical functions of proteins remains challenging due to the possible crosslinking between the functional groups of proteins, and the used photopolymers such as acrylates. In this work, the in vitro release of the model protein drug, albumin-fluorescein isothiocyanate conjugate (BSA-FITC) from differently composed, photopolymerized poly(ethylene) glycol diacrylate (PEGDA), an often employed, nontoxic, easily curable resin, was investigated. Different PEGDA concentrations in water (20, 30, and 40 wt %) and their different molecular masses (4000, 10,000, and 20,000 g/mol) were used to prepare a protein carrier with photopolymerization and molding. The viscosity measurements of photomonomer solutions revealed exponentially increasing values with increasing PEGDA concentration and molecular mass. Polymerized samples showed increasing medium uptake with an increasing molecular mass and decreasing uptake with increasing PEGDA content. Therefore, the modification of the inner network resulted in the most swollen samples (20 wt %) also releasing the highest amount of incorporated BSA-FITC for all PEGDA molecular masses.

15.
Pharmaceutics ; 15(6)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37376033

RESUMO

A novel approach for the long-term medical treatment of the inner ear is the diffusion of drugs through the round window membrane from a patient-individualized, drug-eluting implant, which is inserted in the middle ear. In this study, drug-loaded (10 wt% Dexamethasone) guinea pig round window niche implants (GP-RNIs, ~1.30 mm × 0.95 mm × 0.60 mm) were manufactured with high precision via micro injection molding (µIM, Tmold = 160 °C, crosslinking time of 120 s). Each implant has a handle (~3.00 mm × 1.00 mm × 0.30 mm) that can be used to hold the implant. A medical-grade silicone elastomer was used as implant material. Molds for µIM were 3D printed from a commercially available resin (TG = 84 °C) via a high-resolution DLP process (xy resolution of 32 µm, z resolution of 10 µm, 3D printing time of about 6 h). Drug release, biocompatibility, and bioefficacy of the GP-RNIs were investigated in vitro. GP-RNIs could be successfully produced. The wear of the molds due to thermal stress was observed. However, the molds are suitable for single use in the µIM process. About 10% of the drug load (8.2 ± 0.6 µg) was released after 6 weeks (medium: isotonic saline). The implants showed high biocompatibility over 28 days (lowest cell viability ~80%). Moreover, we found anti-inflammatory effects over 28 days in a TNF-α-reduction test. These results are promising for the development of long-term drug-releasing implants for human inner ear therapy.

16.
Biomed Tech (Berl) ; 68(5): 523-535, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37183602

RESUMO

OBJECTIVES: The study investigated mechanical parameters of stent systems indicated for treatment of femoropopliteal (FP) arterial disease to support interpretation of clinical results and the related causalities. METHODS: Eight stent system types of same dimensions were investigated (n=2). Parameters were the profile of stent delivery system (SDS), radiopacity, trackability and pushability, bending stiffness (flexibility) and axial stiffness of expanded stents, length change during expansion, radial force, crush resistance, strut thickness and general surface condition. RESULTS: The trackability ranged from 0.237 to 0.920 N and the pushability was 47.9-67.6 %. The bending stiffness of SDS was between 108.42 and 412.68 N mm2. The length change during stent release to 5 mm was low, with one exception. The bending stiffness of the expanded stents was 2.73-41.67 N mm2. The normalized radial forces at 5 mm diameter ranged from 0.133 N/mm to 0.503 N/mm. During non-radial compression by 50 %, the forces were 3.07-8.42 N, with one exception (58.7 N). The strut thickness was 153-231 µm. CONCLUSIONS: Large differences occurred for flexibility, radial force and length change during expansion. The data should be used when choosing the proper device for restoring vascular function.


Assuntos
Stents , Desenho de Prótese , Estresse Mecânico
17.
Transl Vis Sci Technol ; 12(3): 4, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36857065

RESUMO

Purpose: Microinvasive glaucoma surgery (MIGS) has become an important treatment approach for primary open-angle glaucoma, although the safe and long-term effective lowering of intraocular pressure with currently available implants for MIGS is not yet achieved to a satisfactory extent. The study focusses on the development and in vitro and in vivo testing of a novel microstent for MIGS. Methods: A silicone elastomer-based microstent was developed. Implants were manufactured using dip coating, fs-laser cutting, and spray coating. Within the current study no antifibrotic drug was loaded into the device. Sterilized microstents were analyzed in vitro regarding pressure-flow characteristics and biocompatibility. Six New Zealand white rabbits were implanted with a microstent draining the aqueous humor from the anterior chamber into the subconjunctival space. Drainage efficacy was evaluated using oculopressure tonometry as a transient glaucoma model. Noninvasive imaging was performed. Results: Microstents were manufactured successfully and characterized in vitro. Implantation in vivo was successful for four animals with additional device fixation. Without additional fixation, dislocation of microstents was found in two animals. Safe and effective intraocular pressure reduction was observed for the four eyes with correctly implanted microstent during the 6-month trial period. Conclusions: The described microstent represents an innovative treatment approach for MIGS. The incorporation of a selectively antifibrotic drug into the microstent drug-elutable coating will be addressed in future investigations. Translational Relevance: The current preclinical study successfully provided proof of concept for our microstent for MIGS which is suitable for safe and effective intraocular pressure reduction and offers promising perspectives for the clinical management of glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Oftalmologia , Animais , Coelhos , Câmara Anterior , Humor Aquoso
18.
Bioengineering (Basel) ; 10(6)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37370674

RESUMO

Chronic otitis media is often connected to Eustachian tube dysfunction. As successful treatment cannot be guaranteed with the currently available options, the aim is to develop a stent for the Eustachian tube (ET). Over the course of this development, different prototypes were generated and tested in ex vivo experiments. Four different prototypes of an ET stent and one commercially available coronary stent were implanted in the ET of seven human donor bodies. The position of the stents was verified by cone beam CT. The implanted ETs were harvested, embedded in resin and ground at 200 µm steps. Resulting images of the single steps were used to generate 3D models. The 3D models were then evaluated regarding position of the stent in the ET, its diameters, amount of squeezing, orientation of the axes and other parameters. Virtual reconstruction of the implanted ET was successful in all cases and revealed one incorrect stent placement. The cross-section increased for all metal stents in direction from the isthmus towards the pharyngeal orifice of the ET. Depending on the individual design of the metal stents (open or closed design), the shape varied also between different positions along a single stent. In contrast, the cross-section area and shape remained constant along the polymeric prototype. With the current investigation, insight into the behavior of different prototypes of ET stents was gained, which can help in defining the specifications for the intended ET stent.

19.
PLoS One ; 17(10): e0275528, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36191031

RESUMO

This paper details the development and testing of the GIFT macro, which is a freely available program for ImageJ for the automated measurement of fiber diameters in SEM images of electrospun materials. The GIFT macro applies a validated method which distinguishes fiber diameters based on distance frequencies within an image. In this work, we introduce an applied version of the GIFT method which has been designed to be user-friendly while still allowing complete control over the various parameters involved in the image processing steps. The macro quickly processes large data sets and creates results that are reproducible and accurate. The program outputs both raw data and fiber diameter averages, so that the user can quickly assess the results and has the opportunity for further analysis if desired. The GIFT macro was compared directly to other software designed for fiber diameter measurements and was found to have comparable or lower average error, especially when measuring very small fibers, and reduced processing times per image. The macro, detailed instructions for use, and sample images are freely available online (https://github.com/IBMTRostock/GIFT). We believe that the GIFT macro is a valuable new tool for researchers looking to quickly, easily and reliably assess fiber diameters in electrospun materials.


Assuntos
Processamento de Imagem Assistida por Computador , Software , Fibras na Dieta
20.
Materials (Basel) ; 15(9)2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-35591381

RESUMO

To prevent endocochlear insertion trauma, the development of drug delivery coatings in the field of CI electrodes has become an increasing focus of research. However, so far, the effect of a polymer coating of PLLA on the mechanical properties, such as the insertion pressure and friction of an electrode array, has not been investigated. In this study, the insertion pressure of a PLLA-coated, 31.5-mm long standard electrode array was examined during placement in a linear cochlear model. Additionally, the friction coefficients between a PLLA-coated electrode array and a tissue simulating the endocochlear lining were acquired. All data were obtained at different insertion speeds (0.1, 0.5, 1.0, 1.5, and 2.0 mm/s) and compared with those of an uncoated electrode array. It was shown that both the maximum insertion pressure generated in the linear model and the friction coefficient of the PLLA-coated electrode did not depend on the insertion speed. At higher insertion speeds above 1.0 mm/s, the insertion pressure (1.268 ± 0.032 mmHg) and the friction coefficient (0.40 ± 0.15) of the coated electrode array were similar to those of an uncoated array (1.252 ± 0.034 mmHg and 0.36 ± 0.15). The present study reveals that a PLLA coating on cochlear electrode arrays has a negligible effect on the electrode array insertion pressure and the friction when higher insertion speeds are used compared with an uncoated electrode array. Therefore, PLLA is a suitable material to be used as a coating for CI electrode arrays and can be considered for a potential drug delivery system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA