RESUMO
PURPOSE: Traditional ERGs recorded using corneal electrodes can be difficult for some patients to tolerate. In the last several years, adhesive skin electrodes have gained in acceptance. In this report we present a qualitative comparison of waveforms as well as a quantitative analysis of correlation of amplitudes and implicit times of simultaneous ERG recordings using contact lens and skin electrodes. METHODS: 89 subjects were included; all were referred for full-field ERG testing for multiple indications. ERGs (obtained according to ISCEV standards) were recorded simultaneously from both eyes with ERG-jet corneal contact lens electrodes and LKC Technologies Sensor Strip adhesive skin electrodes using multi-channel instrumentation (Diagnosys LLC, Espion3). Waveforms, a-wave and b-wave amplitudes and implicit times were compared. RESULTS: Waveform morphologies were similar between electrode types. Regression coefficients (conversion factors) for a-wave and b-wave amplitudes under both photopic and scotopic conditions were tightly clustered. Regression coefficients for implicit times were nearly equal to 1.0. The regression coefficient for the entire amplitude dataset was 0.349, with an overall correlation of 0. 869 between amplitude recorded with skin and contact lens electrodes. The regression coefficient for the entire implicit time dataset was 0.967, with an overall correlation of 0.964 between skin and contact lens electrodes. CONCLUSIONS: Our best estimate for the conversion factor between ERG amplitudes recorded with adhesive skin electrodes and contact lens electrodes is 0.349-amplitudes with skin electrodes are about 1/3 the amplitudes recorded simultaneously from the same eyes with contact lens electrodes, with a high correlation. Implicit times are nearly identical for the two electrode types.
Assuntos
Lentes de Contato , Eletrorretinografia , Adesivos , Córnea , Eletrodos , Humanos , Estimulação Luminosa , RetinaRESUMO
PURPOSE: To develop methods to assess the effects of epiretinal membranes (ERM) and macular holes (MH) coexisting with glaucoma on pre-operative retinal structure and function and evaluate post-operative outcomes. METHODS: Seven eyes of 7 patients with glaucoma, 6 with ERMs and 1 with MH, were enrolled; 4 underwent vitrectomy for ERM and one for MH. Visual fields (VFs) and optical coherence tomography (OCT) scans were obtained pre- and post-operatively. The 10-2VF deviation map was overlayed on ganglion cell and inner plexiform layer (GCL + IPL) and retinal nerve fiber layer (RNFL) deviation maps derived from OCT macula and disc cube scans. Optic nerve circle scans were obtained to assess RNFL thickness, and OCT b-scans associated with VF defects were compared pre- and post-operatively. RESULTS: Examination of pre-operative VFs and OCT scans showed the importance of determining the extent to which glaucomatous damage contributed to VF loss; verifying automated segmentation of the GCL + IPL and RNFL; and assessing foveal anatomy. Evaluation of post-operative structure-function outcomes required correction of magnification changes in OCT scans and repeated follow-up visits to clarify the origin of VF changes. CONCLUSIONS: Pre-operative comparisons of VFs and OCT scans may be beneficial in guiding surgical planning, and evaluating outcomes, in eyes with glaucoma undergoing macular surgery.
Assuntos
Glaucoma , Fibras Nervosas , Glaucoma/complicações , Glaucoma/diagnóstico , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos , Campos VisuaisRESUMO
Cyclic nucleotide-gated channel ß1 (CNGB1) encodes the 240-kDa ß subunit of the rod photoreceptor cyclic nucleotide-gated ion channel. Disease-causing sequence variants in CNGB1 lead to autosomal recessive rod-cone dystrophy/retinitis pigmentosa (RP). We herein present a comprehensive review and analysis of all previously reported CNGB1 sequence variants, and add 22 novel variants, thereby enlarging the spectrum to 84 variants in total, including 24 missense variants (two of which may also affect splicing), 21 nonsense, 19 splicing defects (7 at noncanonical positions), 10 small deletions, 1 small insertion, 1 small insertion-deletion, 7 small duplications, and 1 gross deletion. According to the American College of Medical Genetics and Genomics classification criteria, 59 variants were considered pathogenic or likely pathogenic and 25 were variants of uncertain significance. In addition, we provide further phenotypic data from 34 CNGB1-related RP cases, which, overall, are in line with previous findings suggesting that this form of RP has long-term retention of useful central vision despite the early onset of night blindness, which is valuable for patient counseling, but also has implications for it being considered a priority target for gene therapy trials.
Assuntos
Distrofias de Cones e Bastonetes/genética , Canais de Cátion Regulados por Nucleotídeos Cíclicos/genética , Estudos de Coortes , Distrofias de Cones e Bastonetes/classificação , Distrofias de Cones e Bastonetes/epidemiologia , Distrofias de Cones e Bastonetes/patologia , Análise Mutacional de DNA , Estudos de Associação Genética , Humanos , MutaçãoRESUMO
Purpose: To describe clinical and genetic features in a series of Italian patients with sector retinitis pigmentosa (sector RP). Methods: Fifteen patients with sector RP were selected from the database of Hereditary Retinal Degenerations Referring Center of Careggi Hospital (Florence, Italy). Eleven patients from five independent pedigrees underwent genetic analysis with next-generation sequencing (NGS) confirmed with Sanger sequencing. The diagnosis of sector RP was based on the detection of topographically limited retinal abnormalities consistent with corresponding sectorial visual field defects. Best-corrected visual acuity (BCVA), fundus color pictures as well as fundus autofluorescence (FAF), spectral domain-optical coherence tomography (SD-OCT), full-field electroretinography (ERG), and 30-2 Humphrey visual field (VF) data were retrospectively collected and analyzed. Results: For the 30 eyes, the mean BCVA was 0.05 ± 0.13 logMAR, and the mean refractive error was -0.52 ± 1.89 D. The inferior retina was the most affected sector (86.7%), and the VF defect corresponded to the affected sector. FAF showed a demarcation line of increased autofluorescence between the healthy and affected retina, corresponding on SD-OCT to an interruption of the ellipsoid zone (EZ) band in the diseased retina. Dark-adapted ERG amplitudes were decreased in comparison to normative values. In five unrelated families, the sector RP phenotype was associated with sequence variants in the RHO gene. The same mutation c.568G>A p.(Asp190Asn) was found in nine patients of four families. Conclusions: Typical sector RP is a mild form of RP characterized by preserved visual acuity with limited retinal involvement and, generally, a more favorable prognosis than other forms of RP.
Assuntos
Retinose Pigmentar/diagnóstico , Retinose Pigmentar/genética , Rodopsina/genética , Adulto , Idoso , Adaptação à Escuridão/fisiologia , Eletrorretinografia , Feminino , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Linhagem , Fenótipo , Refração Ocular/fisiologia , Retina/fisiopatologia , Retinose Pigmentar/fisiopatologia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia , Adulto JovemRESUMO
PURPOSE: To assess structure and function across the transition zone (TZ) between relatively healthy and diseased retina in acute zonal occult outer retinopathy. METHODS: Six patients (6 eyes; age 22-71 years) with acute zonal occult outer retinopathy were studied. Spectral-domain optical coherence tomography, fundus autofluorescence, near-infrared reflectance, color fundus photography, and fundus perimetry were performed and images were registered to each other. The retinal layers of the spectral-domain optical coherence tomography scans were segmented and the thicknesses of two outer retinal layers, that is, the total receptor and outer segment plus layers, and the retinal nerve fiber layer were measured. RESULTS: All eyes showed a TZ on multimodal imaging. On spectral-domain optical coherence tomography, the TZ was in the nasal retina at varying distances from the fovea. For all eyes, it was associated with loss of the ellipsoid zone band, significant thinning of the two outer retinal layers, and in three eyes with thickening of the retinal nerve fiber layer. On fundus autofluorescence, all eyes had a clearly demarcated peripapillary area of abnormal fundus autofluorescence delimited by a border of high autofluorescence; the latter was associated with loss of the ellipsoid zone band and with a change from relatively normal to markedly decreased or nonrecordable visual sensitivity on fundus perimetry. CONCLUSION: The results of multimodal imaging clarified the TZ in acute zonal occult outer retinopathy. The TZ was outlined by a distinct high autofluorescence border that correlated with loss of the ellipsoid zone band on spectral-domain optical coherence tomography. However, in fundus areas that seemed healthy on fundus autofluorescence, thinning of the outer retinal layers and thickening of the retinal nerve fiber layer were observed near the TZ. The TZ was also characterized by a decrease in visual sensitivity.
Assuntos
Imagem Multimodal , Segmento Externo das Células Fotorreceptoras da Retina/patologia , Escotoma/diagnóstico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Campos Visuais , Doença Aguda , Adolescente , Adulto , Idoso , Feminino , Angiofluoresceinografia/métodos , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Escotoma/fisiopatologia , Testes de Campo Visual , Síndrome dos Pontos Brancos , Adulto JovemRESUMO
PURPOSE: The purpose of our study was to investigate morpho-functional features of the preferred retinal location (PRL) and the transition zone (TZ) in a series of patients with recessive Stargardt disease (STGD1). METHODS: Fifty-two STGD1 patients with at least one ABCA4 mutation, atrophy of the central macula (MA) and an eccentric PRL were recruited for the study. Microperimetry, fundus autofluorescence (FAF), spectral-domain optical coherence tomography (SD-OCT) were performed. The location and stability of the PRL along with the associated FAF pattern and visual sensitivities were determined and compared to the underlying retinal structure. RESULTS: The mean visual sensitivity of the PRLs for the 52 eyes was 10.76 +/- 3.70 dB. For the majority of eyes, PRLs were associated with intact ellipsoid zone (EZ) bands and qualitatively normal FAF patterns. In 17 eyes (32.7%) the eccentric PRL was located at the edge of the MA. In 35 eyes (67.3%) it was located at varying distances from the border of the MA with a TZ between the PRL and the MA. The TZ was associated with decreased sensitivity values (5.92 +/- 4.69 dB) compared to PRLs (p<0.05), with absence/disruption of the EZ band and abnormal FAF patterns (hyper or hypo-autofluorescence). CONCLUSIONS: In STGD1 eccentric PRLs are located away from the border of MA and associated with intact EZ bands and normal FAF. The TZ is characterized by structural and functional abnormalities. The results of multimodal imaging of the PRL and TZ suggest a possible sequence of retinal and functional changes with disease progression that may help in the planning of future therapies; RPE dysfunction appears to be the primary event leading to photoreceptor degeneration and then to RPE loss.
Assuntos
Macula Lutea/patologia , Degeneração Macular/congênito , Imagem Multimodal/métodos , Epitélio Pigmentado da Retina/patologia , Adulto , Idoso , Feminino , Angiofluoresceinografia/métodos , Fundo de Olho , Humanos , Degeneração Macular/diagnóstico , Degeneração Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Oftalmoscopia/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Doença de Stargardt , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Campos Visuais , Adulto JovemRESUMO
Retinitis pigmentosa (RP), a genetically heterogeneous group of retinopathies that occur in both non-syndromic and syndromic forms, is caused by mutations in â¼100 genes. Although recent advances in next-generation sequencing have aided in the discovery of novel RP genes, a number of the underlying contributing genes and loci remain to be identified. We investigated three siblings, born to asymptomatic parents of Italian-American descent, who each presented with atypical RP with systemic features, including facial dysmorphologies, psychomotor developmental delays recognized since early childhood, learning disabilities and short stature. RP-associated ophthalmological findings included salt-and-pepper retinopathy, attenuation of the arterioles and generalized rod-cone dysfunction as determined by almost extinguished electroretinogram in 2 of 3 siblings. Atypical for RP features included mottled macula at an early age and peripapillary sparing of the retinal pigment epithelium. Whole-exome sequencing data, queried under a recessive model of inheritance, identified compound heterozygous stop mutations, c.C199T:p.R67* and c.C322T:p.R108*, in the retinol dehydrogenase 11 (RDH11) gene, resulting in a non-functional protein, in all affected children. In summary, deleterious mutations in RDH11, an important enzyme for vision-related and systemic retinoic acid metabolism, cause a new syndrome with RP.
Assuntos
Códon sem Sentido , Oxirredutases/genética , Retinose Pigmentar/genética , Adolescente , Criança , Feminino , Humanos , Masculino , Linhagem , Fenótipo , Retinose Pigmentar/diagnóstico , Síndrome , Testes Visuais , Acuidade Visual , Adulto JovemRESUMO
PURPOSE: To describe a series of patients with Stargardt disease (STGD1) exhibiting a phenotype usually associated with hydroxychloroquine (HCQ) retinopathy on spectral domain-optical coherence tomography (SD-OCT). METHODS: Observational case series from Columbia University Medical Center involving eight patients with genetically-confirmed STGD1. Patients selected for the study presented no history of HCQ use. Horizontal macular SD-OCT scans and accompanying 488-nm autofluorescence (AF) images, color fundus photographs, and full-field electroretinograms were analyzed. RESULTS: All study patients exhibited an abrupt thinning of the parafoveal region or disruption of the outer retinal layers on SD-OCT resembling the transient HCQ retinopathy phenotype. Funduscopy and AF imaging revealed variations of bull's eye maculopathy (BEM). Five patients exhibited local fleck-like deposits around the lesion. Genetic screening confirmed two disease-causing ABCA4 mutations in five patients and one mutation in three patients. CONCLUSIONS: A transient SD-OCT phenotype ascribed to patients with HCQ retinopathy is associated with an early subtype of STGD1. This finding may also present with HCQ retinopathy-like BEM lesions on AF imaging and funduscopy. A possible phenotypic overlap is unsurprising, given certain shared mechanistic disease processes between the two conditions. A thorough work-up, including screening of genes that are causal in retinal dystrophies associated with foveal sparing, may prevent misdiagnosis of more ambiguous cases.
Assuntos
Transportadores de Cassetes de Ligação de ATP/genética , Antimaláricos/toxicidade , Hidroxicloroquina/toxicidade , Degeneração Macular/congênito , Doenças Retinianas/diagnóstico , Adulto , Criança , Eletrorretinografia , Feminino , Genes Recessivos , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Degeneração Macular/diagnóstico , Degeneração Macular/genética , Masculino , Pessoa de Meia-Idade , Mutação , Fenótipo , Doenças Retinianas/induzido quimicamente , Estudos Retrospectivos , Doença de Stargardt , Tomografia de Coerência Óptica , Adulto JovemRESUMO
PURPOSE: The aims of this retrospective study were to compare the results of recommended screening tests for hydroxychloroquine-related retinal toxicity and analyze disparities between the structural and functional findings. METHODS: Thirty-four patients (31 women and 3 men) were included in the study. All were evaluated with standard automated perimetry using the 10-2 and/or 24-2 visual field program (Zeiss, Meditec), multifocal electroretinography (mfERG), spectral-domain optical coherence tomography (SD-OCT), and short-wavelength fundus autofluorescent imaging (SW-FAF). The results for the right eye from each patient were analyzed. Visual fields were classified as normal or abnormal based on pattern deviation plots, and mfERGs based on a comparison of R5 ring ratios to values from 20 controls. The SW-FAF images were examined for areas/rings of abnormal hypo- and/or hyperautofluorescence, and the SD-OCT line scans were classified as abnormal based on visual inspection and thickness measurements of the outer segment plus retinal pigment epithelial layer and total receptor layers compared to mean thicknesses from 35 controls. RESULTS: Fifteen patients had abnormal results on at least one test; however, only two patients had abnormal results on all four tests. Excluding SW-FAF, seven of the 15 had abnormal visual fields, mfERG ring ratios, and SD-OCTs. The remaining eight had either abnormal mfERGs and/or visual fields and normal SD-OCTs. We found no evidence of abnormal SD-OCTs in the presence of normal mfERG and visual field results. CONCLUSIONS: The findings suggest that functional deficits precede structural changes seen on SD-OCT in these patients.
Assuntos
Antirreumáticos/efeitos adversos , Hidroxicloroquina/efeitos adversos , Retina/fisiopatologia , Doenças Retinianas/fisiopatologia , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Eletrorretinografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retina/efeitos dos fármacos , Doenças Retinianas/induzido quimicamente , Doenças Retinianas/diagnóstico , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Testes de Campo VisualRESUMO
The aim of this study was to investigate visualization of the tapetal-like reflex using current imaging modalities and evaluate SD-OCT changes in known carriers of X-linked retinitis pigmentosa (XLRP); the objective being the development of an optimal protocol for clinicians to identify carriers. Ten XLRP carriers (19 eyes) were examined using color fundus photography, 488 nm reflectance (488-R), near-infrared reflectance (NIR-R), autofluorescence (AF) and spectral domain optical coherence tomography (SD-OCT) imaging (Spectralis SLO-OCT, Heidelberg). Horizontal line scans through the fovea were acquired in all subjects and in a group of 10 age-similar controls. Peripheral SD-OCT scans (extending to 27.5° eccentricity) were also acquired in both eyes of 7 carriers. MP-1 microperimetery (10-2 pattern; Nidek) was performed in one eye of each carrier. For the XLRP carriers, a tapetal reflex was observed with all imaging modalities in 8 of 19 eyes. It had the same retinal location on color fundus, 488-R and NIR-R imaging but a different location on AF. The tapetal reflex was most easily detected in 488-R images. The horizontal foveal SD-OCT scans were qualitatively normal, but measurements showed significant outer retinal layer thinning in all eyes. Additionally, the 14 eyes with peripheral SD-OCTs demonstrated patchy loss of the inner segment ellipsoid band. Microperimetry exhibited patchy visual sensitivity loss in 9 eyes. Full field ERGs were variable, ranging from normal to severely abnormal rod and cone responses. Our findings suggest that an optimal protocol for identifying carriers of XLRP should include 488-R imaging in a multimodal approach. Peripheral SD-OCT imaging and central retinal layer quantification revealed significant structural abnormalities.
Assuntos
Técnicas de Diagnóstico Oftalmológico , Triagem de Portadores Genéticos , Doenças Genéticas Ligadas ao Cromossomo X/diagnóstico , Retina/patologia , Retinose Pigmentar/diagnóstico , Tomografia de Coerência Óptica , Adulto , Eletrorretinografia , Proteínas do Olho/genética , Feminino , Fundo de Olho , Doenças Genéticas Ligadas ao Cromossomo X/genética , Humanos , Pessoa de Meia-Idade , Oftalmoscopia , Linhagem , Retinose Pigmentar/genética , Testes de Campo VisualRESUMO
PURPOSE: To compare full-field stimulus (FST) threshold values to conventional functional and anatomical measures commonly used in clinical practice. DESIGN: Cross-sectional study. METHODS: Patients with retinitis pigmentosa with nondetectable electroretinogram rod-mediated responses and light-adapted 3.0 cd·s·m2 30-Hz flicker (LA 3.0 flicker) amplitudes of 15 mV or less were included in this study. The threshold values for blue, white, and red stimuli on FST were correlated with best-corrected visual acuity, LA 3.0 flicker amplitude and implicit times, length of the ellipsoid zone (EZ) band and thickness of outer nuclear layer measurements on optical coherence tomography, and the vertical and horizontal diameters of the autofluorescent ring on autofluorescence imaging. RESULTS: Forty-two eyes of 21 patients were included in the study. The mean FST thresholds were -22.5 ± 15.5 dB, -17.6 ± 11.5 dB, and -12.7 ± 6.0 dB for the blue, white, and red stimuli, respectively. The threshold values for the 3 FST stimuli were significantly correlated with selected functional and anatomical outcome measures. Specifically, they were strongly correlated with LA 3.0 flicker amplitude and EZ band length measured on optical coherence tomography. Using linear regression, blue and white stimulus values on FST were found to be predictive of EZ band length (R2 = 0.579 and 0.491, respectively), and the vertical (R2 = 0.694 and 0.532, respectively) and horizontal (R2 = 0.626 and 0.400, respectively) diameters of the hyperautofluorescent ring. CONCLUSIONS: The significant correlations between FST and other clinical outcome measures highlight its potential as an adjunct outcome measure.
Assuntos
Eletrorretinografia , Retinose Pigmentar , Humanos , Campos Visuais , Acuidade Visual , Estudos Transversais , Retinose Pigmentar/diagnóstico , Tomografia de Coerência Óptica/métodos , RetinaRESUMO
Purpose: To compare longitudinal changes in en face spectral domain-optical coherence tomography (SD-OCT) measurements of ellipsoid zone (EZ) and retinal pigment epithelium (RPE) loss to changes in the hypoautofluorescent and hyperautofluorescent (AF) areas detected with short-wavelength (SW)-AF in ABCA4-associated retinopathy. Methods: SD-OCT volume scans were obtained from 20 patients (20 eyes) over 2.6 ± 1.2 years (range 1-5 years). The EZ, and RPE/Bruch's membrane boundaries were segmented, and en face slab images generated. SubRPE and EZ slab images were used to measure areas of atrophic RPE and EZ loss. These were compared to longitudinal measurements of the hypo- and abnormal AF (hypoAF and surrounding hyperAF) areas. Results: At baseline, the en face area of EZ loss was significantly larger than the subRPE atrophic area, and the abnormal AF area was significantly larger than the hypoAF area. The median rate of EZ loss was significantly greater than the rate of increase in the subRPE atrophic area (1.2 mm2/yr compared to 0.5 mm2/yr). The median rate of increase in the abnormal AF area was significantly greater than the increase in the hypoAF area (1.6 mm2/yr compared to 0.6 mm2/yr). Conclusions: En face SD-OCT can be used to quantify changes in RPE atrophy and photoreceptor integrity. It can be a complementary or alternative technique to SW-AF with the advantage of monitoring EZ loss. The SW-AF results emphasize the importance of measuring changes in the hypo- and abnormal AF areas. Translational Relevance: The findings are relevant to the selection of outcome measures for monitoring ABCA4-associated retinopathy.
Assuntos
Doenças Retinianas , Tomografia de Coerência Óptica , Humanos , Doença de Stargardt , Tomografia de Coerência Óptica/métodos , Angiofluoresceinografia/métodos , Fundo de Olho , Transportadores de Cassetes de Ligação de ATPRESUMO
PURPOSE: To analyze the structure and visual function of regions bordering the hyperautofluorescent ring/arcs in retinitis pigmentosa. METHODS: Twenty-one retinitis pigmentosa patients (21 eyes) with rings/arcs and 21 normal individuals (21 eyes) were studied. Visual sensitivity in the central 10° was measured with microperimetry. Retinal structure was evaluated with spectral-domain optical coherence tomography. The distance from the fovea to disruption/loss of the inner outer segment (IS/OS) junction and thicknesses of the total receptor plus retinal pigment epithelial complex and outer segment plus retinal pigment epithelial complex layers were measured. Results were compared with measurements of the distance from the fovea to the inner and outer borders of the ring/arc seen on fundus autofluorescence. RESULTS: Disruption/loss of the inner outer segment junction occurred closer to the inner border of the ring/arc and it was closer to the fovea in eight eyes. For 19 eyes, outer segment plus and receptor plus RPE complex thicknesses were significantly decreased at locations closer to the fovea than the appearance of the inner border of hyperautofluorescence. Mean visual sensitivity was decreased inside, across, and outside the ring/arc by 3.5 ± 3.8, 8.9 ± 4.8, and 17.0 ± 2.4 dB, respectively. CONCLUSION: Structural and functional changes can occur inside the hyperfluorescent ring/arc in retinitis pigmentosa.
Assuntos
Angiofluoresceinografia , Fundo de Olho , Retina/fisiopatologia , Retinose Pigmentar/fisiopatologia , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscópios , Tomografia de Coerência Óptica , Testes de Campo VisualRESUMO
PURPOSE: To report the presence of a hyperautofluorescent ring and corresponding spectral-domain optical coherence tomography (SD-OCT) features seen in patients with autoimmune retinopathy. METHODS: All eyes were evaluated by funduscopic examination, full-field electroretinography, fundus autofluorescence, and SD-OCT. Further confirmation of the diagnosis was obtained with immunoblot and immunohistochemistry testing of the patient's serum. Humphrey visual fields and microperimetry were also performed. RESULTS: Funduscopic examination showed atrophic retinal pigment epithelium (RPE) associated with retinal artery narrowing but without pigment deposits. The scotopic and photopic full-field electroretinograms were nondetectable in three patients and showed a cone-rod pattern of dysfunction in one patient. Fundus autofluorescence revealed a hyperautofluorescent ring in the parafoveal region, and the corresponding SD-OCT demonstrated loss of the photoreceptor inner segment-outer segment junction with thinning of the outer nuclear layer from the region of the hyperautofluorescent ring toward the retinal periphery. The retinal layers were generally intact within the hyperautofluorescent ring, although the inner segment-outer segment junction was disrupted, and the outer nuclear layer and photoreceptor outer segment layer were thinned. CONCLUSION: This case series revealed the structure of the hyperautofluorescent ring in autoimmune retinopathy using SD-OCT. Fundus autofluorescence and SD-OCT may aid in the diagnosis of autoimmune retinopathy and may serve as a tool to monitor its progression.
Assuntos
Doenças Autoimunes/diagnóstico , Síndromes Paraneoplásicas Oculares/diagnóstico , Doenças Retinianas/diagnóstico , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Atrofia , Autoanticorpos/sangue , Autoantígenos/imunologia , Doenças Autoimunes/fisiopatologia , Feminino , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Síndromes Paraneoplásicas Oculares/fisiopatologia , Células Fotorreceptoras de Vertebrados/patologia , Retina/imunologia , Artéria Retiniana/patologia , Doenças Retinianas/fisiopatologia , Epitélio Pigmentado da Retina/patologia , Escotoma/diagnóstico , Testes de Campo Visual , Campos VisuaisRESUMO
PURPOSE: To compare MP-1 microperimeter and Humphrey Field Analyzer (HFA) defects, in patients with retinitis pigmentosa (RP), a disease primarily affecting the photoreceptors, and in patients with glaucoma, a disease primarily affecting postreceptoral ganglion cells, and to analyze the similarities and differences between the results. METHODS: Eleven patients (11 eyes) with RP and 10 patients (10 eyes) with primary open-angle glaucoma (OAG) underwent MP-1 and HFA visual field testing (10-2 pattern). All tested eyes had defects encroaching within 10° of fixation. MP-1 total deviation (TD) probability defects, derived from a previously collected normative database of 50 subjects, were compared to HFA TD defects and to the local defect map of the MP-1. Test duration was compared between instruments. RESULTS: In RP patients, MP-1 scotomata were deeper and wider than HFA defects; however in OAG, the opposite was observed. Examination duration in both patient groups was 12 to 14 min for the MP-1 and 6 min for the HFA. The MP-1 local defect map tended to overestimate defects compared to the MP-1 TD analysis. CONCLUSIONS: The differences in results between the MP-1 and HFA for the two groups of patients with RP and OAG can be attributed to the different adaptation levels and to the dynamic range of test lights available for the two instruments. The clinician should also be aware of the possible consequences of the differences in the method of derivation of normative data for the two instruments, as this may affect the interpretation of visual field results.
Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Retinose Pigmentar/fisiopatologia , Escotoma/fisiopatologia , Testes de Campo Visual/instrumentação , Campos Visuais , Adolescente , Adulto , Criança , Diagnóstico Diferencial , Desenho de Equipamento , Feminino , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Retinose Pigmentar/complicações , Retinose Pigmentar/diagnóstico , Escotoma/diagnóstico , Escotoma/etiologia , Adulto JovemRESUMO
Purpose: In choroideremia (CHM) carriers, scotopic sensitivity was assessed by dark adapted chromatic perimetry (DACP) and outer retinal structure was evaluated by multimodal imaging. Methods: Nine carriers (18 eyes) and 13 healthy controls (13 eyes) underwent DACP testing with cyan and red stimuli. Analysis addressed peripapillary (4 test locations closest to the optic disc), macular (52 locations), and peripheral (60 locations outside the macula) regions. Responses were considered to be rod-mediated when cyan relative to red sensitivity was >5 dB. Fundus imaging included spectral domain optical coherence tomography (SD-OCT), short-wavelength (SW-AF), near-infrared (NIR-AF), ultrawide-field (200 degrees) pseudocolor fundus imaging, and quantitative (qAF) fundus autofluorescence. Results: Detection of the cyan stimulus was rod mediated in essentially all test locations (99.7%). In the macular and peripheral areas, DACP sensitivity values were not significantly different from healthy eyes. In the peripapillary area, sensitivities were significantly decreased (P < 0.05). SD-OCT imaging ranged from hyper-reflective lesions and discontinuities of the outer retinal bands to hypertransmission of signal. SW-AF and NIR-AF images presented with peripapillary atrophy in seven patients (14 eyes). Mosaicism was detectable in SW-AF images in seven patients and in NIR-AF images in five patients. Frank hypo-autofluorescence was visible in eight patients with distinct chorioretinopathy in seven patients. The qAF values were below the 95% confidence interval (CI) of healthy age-matched individuals in 12 eyes. Conclusions: Rod mediated scotopic sensitivity was comparable to that in control eyes in macular and peripheral areas but was decreased in the peripapillary area where changes in retinal structure were also most severe.
Assuntos
Coroideremia , Coroideremia/diagnóstico , Coroideremia/patologia , Angiofluoresceinografia/métodos , Fundo de Olho , Humanos , Retina/diagnóstico por imagem , Retina/patologia , Tomografia de Coerência Óptica/métodos , Testes de Campo VisualRESUMO
PURPOSE: In ABCA4-associated retinopathy, central atrophy was assessed by spectral domain optical coherence tomography (SD-OCT) and by short-wavelength (SW-AF) and near-infrared (NIR-AF) autofluorescence. METHODS: Patients exhibited a central atrophic lesion characterized by hypoautofluorescence (hypoAF) surrounded either by hyperautofluorescent (hyperAF) rings in both AF images (group 1, 4 patients); or a hyperAF ring in SW-AF but not in NIR-AF images (group 2, 11 patients); or hyperAF rings in neither AF images (group 3, 11 patients). Choroidal hypertransmission and widths of ellipsoid zone (EZ) loss were measured in foveal SD-OCT scans, and in AF images hypoAF and total hypo+hyperAF widths were measured along the same axis. Bland-Altman and repeated measures analysis of variance with Tukey post hoc were applied. RESULTS: For all groups, hypertransmission widths were significantly smaller than EZ loss widths. In Groups 1 and 2, hypertransmission width was not significantly different than SW-hypoAF width, but hypertransmission was narrower than the width of SW-hypo+hyperAF (groups 1, 2) and NIR-hypo+hyperAF (group 1). In group 3, the hypertransmission width was also significantly less than the width of SW-hypoAF and NIR-hypoAF. The EZ loss widths were not significantly different than measurements of total lesion size, the latter being the widths of SW-hypo+hyperAF and NIR-hypo+hyperAF (group 1); widths of NIR-hypoAF and SW-hypo+hyperAF (group 2); and widths of NIR-hypoAF and SW-hypoAF (group 3). CONCLUSIONS: Hypertransmission and SW-hypoAF (except when reflecting total lesion width) underestimate lesion size detected by EZ loss, SW-hypoAF+hyperAF, and NIR-hypo+hyperAF. TRANSLATIONAL RELEVANCE: The findings are significant to the selection of outcome measures in clinical studies.
Assuntos
Fóvea Central , Tomografia de Coerência Óptica , Transportadores de Cassetes de Ligação de ATP/genética , Atrofia/patologia , Angiofluoresceinografia/métodos , Fundo de Olho , Humanos , Tomografia de Coerência Óptica/métodosRESUMO
Bietti crystalline dystrophy (BCD) is an ultra-rare orphan disorder that can lead to blindness. Because of the variable rates of progression of the disease, it is necessary to identify suitable outcome measurements for tracking progression in BCD. A retrospective analysis of patients with a clinical and genetic diagnosis of BCD was conducted. Four measurements of spectral domain-optical coherence tomography were compared to patients' best corrected visual acuity. We observed that patients with higher measurements of foveolar thickness, choroidal thickness in the foveolar region, ellipsoid zone band length and the outer nuclear layer + area, had on average better visual acuity. Future studies are needed to validate the structural-functional correlations we observed in BCD and to propose a sensitive and clinically meaningful outcome measurement for tracking this rare, variable disease.
Assuntos
Distrofias Hereditárias da Córnea , Doenças Retinianas , Distrofias Hereditárias da Córnea/diagnóstico por imagem , Distrofias Hereditárias da Córnea/genética , Humanos , Doenças Retinianas/diagnóstico , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodosRESUMO
To evaluate eyes with abnormal visual fields and multifocal electroretinograms (mfERGs) but normal-appearing frequency-domain optical coherence tomography (fdOCT) scans, the thicknesses of the outer retinal layers were measured. A total of 25 eyes from 17 patients, including 15 eyes previously tested (Dale et al. in Doc Ophthalmol 120(2):175-186, 2009) were examined. All patients were evaluated with standard automated perimetry (SAP) using the 24-2 and/or 10-2 program (Zeiss Meditec), mfERG with 103 hexagons (Veris, EDI), and fdOCT imaging (3DOCT-2000, Topcon) with scans of the macula. All patients had reliable visual fields showing macular defects and good quality mfERG and fdOCT results. The mfERG results were classified as abnormal based on decreased amplitudes and/or increased latencies corresponding to the abnormal visual field. Based on visual inspection, three experienced observers classified the fdOCT scans as normal or inconclusive, as opposed to clearly abnormal. Retinal layers of the fdOCT scans were manually segmented with the aid of a computer program and compared to mean thicknesses from 20 controls. The thicknesses of the outer segment plus retinal pigment epithelium, total receptor, and inner nuclear layers were measured. Quantitative analysis of fdOCT scans demonstrated thinning of the outer retina in some scans that was not readily apparent on visual inspection. One or more of the outer retinal layers was significantly thinner in 15 of the 25 eyes. The absence of significant thinning in the other 10 eyes represents instances in which functional loss measured by visual fields and mfERGs can precede clear structural changes on fdOCT.
Assuntos
Eletrorretinografia/métodos , Retina/fisiopatologia , Transtornos da Visão/fisiopatologia , Campos Visuais , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Retina/patologia , Retinoscopia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Transtornos da Visão/diagnóstico , Testes de Campo VisualRESUMO
PURPOSE: To compare visual fields on the Nidek MP-1 to those obtained on the Humphrey field analyzer (HFA) in healthy volunteers and assess the effects of differences in stimulus parameters and testing strategies that may influence the interpretation of results in patients. A secondary aim was to establish MP-1 normative data to calculate the total deviation analyses and global indices analogous to those used by the HFA. METHODS: Fifty healthy volunteers (age 43.5 ± 13.9 years, range, 18 to 68 years) underwent repeat MP-1 and HFA visual field testing, using the 10-2 pattern. MP-1 data were converted to HFA equivalent dB units. Between instrument comparisons of HFA and MP-1 sensitivities, regression of sensitivity with age and examination duration were assessed. Test-retest variability was examined between visits. RESULTS: MP-1 (mean = 32.82 dB, SD = 1.92 dB) and HFA sensitivities (mean = 32.84 dB, SD = 1.83 dB) were not significantly different (p = 0.759). SD values for the HFA (range, 1.11 to 3.30 dB) were similar to the MP-1 (range, 0.14 to 2.75 dB). However, asymmetry comparisons between instruments showed significantly decreased superior rather than inferior retinal values for the MP-1. There was a small but significant difference (p = 0.004) in mean test duration between the MP-1 (mean = 6:11 min, SD = 1:49 min) and the HFA (mean = 5:14 min, SD = 0:42 min). There was also a difference in the decline of mean sensitivity with age, a decline of 0.1 and 0.4 dB per decade was noted in MP-1 and HFA sensitivity, respectively. Test-retest variability was similar between instruments. A small but non-significant increase in mean sensitivity at the second visit for both the MP-1 (p = 0.060) and HFA (p = 0.570) was found. CONCLUSIONS: Both instruments showed similar variability and test-retest variability when results were compared using equivalent units. However, there are important differences in sensitivity values, stimulus parameters, and testing strategies that have to be taken into account when comparisons are made.