Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Pharm Ther ; 35(1): 63-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20175813

RESUMO

BACKGROUND: Clinical positron emission tomography (PET) requires safe and effective PET radiopharmaceuticals. Tracers used for measuring oxygen consumption and blood volume are [(15)O]O(2) and [(15)O]CO, respectively. In general, these oxygen-15 labelled tracers are produced using a cyclotron that accelerates deuterons onto a target filled with (14)N(2) containing a trace of oxygen. In recent years, cyclotrons have been developed that only are capable of accelerating protons. The purpose of this study was to validate and assess such a cyclotron for production and administration of oxygen-15 labelled gasses in an hospital setting. METHODS: An RDS111 cyclotron (Siemens-CTI, Knoxville, USA) was validated for bolus production of [(15)O]O(2) and [(15)O]CO gasses. In addition, equipment was developed to administer these tracers to patients. RESULTS: Both [(15)O]O(2) and [(15)O]CO gasses could be produced in sufficient amounts, whilst meeting European Pharmacopeia requirements. Although produced oxygen-15 gasses contained a minor level of (11)C contamination, in clinical studies it was possible to correct for this contamination by delayed blood counting. CONCLUSION: An 11 MeV proton cyclotron combined with an in-house developed gas delivery system allows for the production and administration of sufficient amounts of [(15)O]-gasses for routine clinical PET studies in an hospital setting.


Assuntos
Monóxido de Carbono , Ciclotrons , Radioisótopos de Oxigênio , Oxigênio , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Administração por Inalação , Gasometria , Monóxido de Carbono/sangue , Monóxido de Carbono/química , Radioisótopos de Carbono/sangue , Radioisótopos de Carbono/química , Contaminação de Medicamentos , Humanos , Insuflação/instrumentação , Oxigênio/sangue , Oxigênio/química , Radioisótopos de Oxigênio/sangue , Radioisótopos de Oxigênio/química , Tomografia por Emissão de Pósitrons/instrumentação , Controle de Qualidade , Compostos Radiofarmacêuticos/sangue , Compostos Radiofarmacêuticos/química
2.
Melanoma Res ; 8(5): 413-8, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9835454

RESUMO

Sentinel node (SN) biopsy is a staging technique used to select patients for regional lymphadenectomy in melanoma. We compared the two most widely used radioactive tracers, 99mTc-colloidal albumin (99mTc-CA) and 99mTc-sulphur colloid (99mTc-SC), with respect to scintigraphy, success rate in gamma probe guided biopsy and absolute uptake in the SN. Scintigraphy was performed in six volunteers after simultaneous injection of the respective tracers in each leg. Comparison of uptake of both tracers showed a higher uptake on the 99mTc-CA side. The scintigraphic count ratio of SNs labelled with 99mTc-SC compared with 99mTc-CA was 1 to 9 28. Next, 20 patients with biopsy-proven melanoma were randomized for injection of 99mTc-CA or 99mTc-SC followed by SN biopsy. Within 20 min after the injection, focal uptake was seen in all cases of the 99mTc-CA group but in only seven of the 10 patients in the 99mTc-SC group (P < 0.05). Focal accumulations were seen in all patients of both groups after 2 h. Spill to non-SNs was seen in five of the 99mTc-CA patients and three of the 99mTc-SC patients. In all patients the SNs could be retrieved under the guidance of a gamma probe and blue dye. The uptake in the SN was significantly higher (P < 0.001) after the injection of 99mTc-CA (0.92+/-0.40%) compared with 99mTc-SC (0.34+/-0.34%). When dynamic scintigraphy is performed, 99mTc-CA is preferable. SN uptake of 99mTc-SC is less than that of 99mTc-CA but this does not adversely affect the surgical procedure.


Assuntos
Linfonodos/diagnóstico por imagem , Linfonodos/metabolismo , Melanoma/diagnóstico por imagem , Melanoma/metabolismo , Compostos Radiofarmacêuticos/farmacocinética , Agregado de Albumina Marcado com Tecnécio Tc 99m/farmacocinética , Coloide de Enxofre Marcado com Tecnécio Tc 99m/farmacocinética , Adulto , Idoso , Transporte Biológico , Biópsia , Feminino , Humanos , Linfonodos/patologia , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA