Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Hematol ; 103(6): 2123-2131, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38436671

RESUMO

Monoclonal antibodies, as tixagevimab/cilgavimab, have been introduced as prophylaxis against COVID-19 infections in high-risk populations. However, data on efficacy are limited. This study investigates efficacy and tolerability of tixagevimab/cilgavimab in hematological patients under real-life conditions. Tixagevimab/cilgavimab was administered to 155 hematological patients (March-August 2022) at two Austrian centres. S/RBD-antibody assessments were performed before (T0), four weeks (T1), and six months (T2) after application. Side effects, the occurrence of COVID-19 infections, and the course of S/RBD-antibody titres were analysed retrospectively in relation to clinical variables. 155 hematological patients, who refused tixagevimab/cilgavimab, were included as a control group to compare the frequency of COVID-19 infections. Of all immunised patients (52.3% males; 91% triple vaccinated), 25.8% had a COVID-19 breakthrough infection (76% mild) compared to 43.9% in the control group. Patients with chronic lymphocytic leukaemia (CLL)/lymphoma were at highest risk of a COVID-19 infection (OR = 2.21; 95% CI 1.05-4.65; p = 0.037). After immunisation, a steep increase in median antibody levels (1193.4BAU/ml, IQR 0-2318.94) was observed in 67.8%, followed by a rapid decrease between T1 and T2 (465.95BAU/ml, IQR 0-1900.65.3) with the greatest declines in CLL/lymphoma (848.7BAU/ml, IQR 0-1949.6, p = 0.026). Side-effects occurred in 21.2% (CTCAE I/II). These real-world data indicate that S/RBD antibodies respond rapidly after passive immunisation in all hematological patients without safety concerns. Given the rapid decline in S/RBD antibodies, early booster immunisations should be considered for future scenarios in this vulnerable group.


Assuntos
Anticorpos Monoclonais Humanizados , COVID-19 , Neoplasias Hematológicas , SARS-CoV-2 , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Hematológicas/terapia , Neoplasias Hematológicas/imunologia , Neoplasias Hematológicas/complicações , Idoso , COVID-19/prevenção & controle , COVID-19/imunologia , COVID-19/epidemiologia , COVID-19/complicações , Estudos Retrospectivos , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais Humanizados/efeitos adversos , SARS-CoV-2/imunologia , Adulto , Idoso de 80 Anos ou mais , Imunização Passiva , Anticorpos Antivirais/sangue , Infecções Irruptivas
2.
J Immunol ; 208(5): 1248-1258, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35173033

RESUMO

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare hemolytic disease driven by impaired complement regulation. Mutations in genes encoding the enzymes that build the GPI anchors are causative, with somatic mutations in the PIG-A gene occurring most frequently. As a result, the important membrane-bound complement regulators CD55 and CD59 are missing on the affected hematopoietic stem cells and their progeny, rendering those cells vulnerable to complement attack. Immune escape mechanisms sparing affected PNH stem cells from removal are suspected in the PNH pathogenesis, but molecular mechanisms have not been elucidated. We hypothesized that exuberant complement activity in PNH results in enhanced immune checkpoint interactions, providing a molecular basis for the potential immune escape in PNH. In a series of PNH patients, we found increased expression levels of the checkpoint ligand programmed death-ligand 1 (PD-L1) on granulocytes and monocytes, as well as in the plasma of PNH patients. Mechanistically, we demonstrate that complement activation leading to the decoration of particles/cells with C3- and/or C4-opsonins increased PD-L1 expression on neutrophils and monocytes as shown for different in vitro models of classical or alternative pathway activation. We further establish in vitro that complement inhibition at the level of C3, but not C5, inhibits the alternative pathway-mediated upregulation of PD-L1 and show by means of soluble PD-L1 that this observation translates into the clinical situation when PNH patients are treated with either C3 or C5 inhibitors. Together, the presented data show that the checkpoint ligand PD-L1 is increased in PNH patients, which correlates with proximal complement activation.


Assuntos
Antígeno B7-H1/metabolismo , Ativação do Complemento/imunologia , Complemento C3/antagonistas & inibidores , Complemento C5/antagonistas & inibidores , Hemoglobinúria Paroxística/patologia , Antígeno B7-H1/sangue , Antígenos CD55/genética , Antígenos CD59/genética , Complemento C3/imunologia , Complemento C5/imunologia , Granulócitos/metabolismo , Células-Tronco Hematopoéticas/citologia , Hemoglobinúria Paroxística/imunologia , Humanos , Evasão da Resposta Imune/imunologia , Proteínas de Membrana/genética , Monócitos/metabolismo
3.
J Infect Dis ; 228(2): 160-168, 2023 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-36869832

RESUMO

BACKGROUND: The emerged severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Omicron variants BA.1, BA.2, and BA.4/5 demonstrate higher transmission and infection rates than previous variants of concern. To evaluate effectiveness of heterologous and homologous booster vaccination, we directly compared cellular and humoral immune responses as well as neutralizing capacity against replication-competent SARS-CoV-2 wild type, Delta, and Omicron variants BA.1, BA.2, and BA.4/5. METHODS: Peripheral blood mononuclear cells and serum samples from 137 participants were investigated, in 3 major groups. Individuals in the first group were vaccinated twice with ChAdOx1 and boosted with a messenger RNA (mRNA) vaccine (BNT162b2 or mRNA-1273); the second group included triple mRNA--vaccinated participants, and the third group, twice-vaccinated and convalescent individuals. RESULTS: Vaccination and convalescence resulted in the highest SARS-CoV-2-specific antibody levels, stronger T-cell responses, and best neutralization against wild type, Delta Omicron BA.2, and BA.4/5, while a combination of ChAdOx1 and BNT162b2 vaccination elevated neutralizing capacity against Omicron BA.1. In addition, heterologous booster regimens, compared with homologous regimens, showed higher efficacy against Omicron BA.2 as well as BA.4/5. CONCLUSIONS: We showed that twice-vaccinated and convalescent individuals demonstrated the strongest immunity against Omicron BA.2 and BA.4/5 variant, followed by those receiving heterologous and homologous booster vaccine regimens.


Assuntos
Vacina BNT162 , COVID-19 , Humanos , Leucócitos Mononucleares , SARS-CoV-2/genética , Anticorpos Antivirais , RNA Mensageiro , Anticorpos Neutralizantes
4.
Eur J Neurol ; 30(4): 991-1000, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36694294

RESUMO

BACKGROUND AND PURPOSE: Sexual dysfunction (SD) in people with multiple sclerosis (pwMS) is common and an often underestimated issue in the care of pwMS. The objective of the study was to evaluate risk factors for SD in pwMS, correlate its prevalence with patient-reported measures (quality of life and physical activity) and analyse its association with hormonal status. METHODS: Sexual dysfunction was determined in 152 pwMS using the Multiple Sclerosis Intimacy and Sexuality Questionnaire 19. A logistical regression model was used to identify independent risk factors for SD. RESULTS: The prevalence of SD in pwMS was 47%. Independent risk factors for the development of SD were ever-smoking (odds ratio [OR] 3.4, p = 0.023), disability as measured by the Expanded Disability Status Scale (OR 2.0, p < 0.001), depression (OR 4.3, p = 0.047) and bladder and bowel dysfunction (OR 8.8, p < 0.001); the use of disease-modifying treatment was associated with a lower risk for SD (OR 0.32, p = 0.043). SD was associated with worse quality of life (Multiple Sclerosis Impact Scale 29: physical score 6.3 vs. 40.0; psychological score 8.3 vs. 33.3; both p < 0.001) and lower physical activity (Baecke questionnaire, p < 0.001). Laboratory analysis revealed significantly higher luteinizing hormone and follicle-stimulating hormone levels and lower 17-beta oestradiol, androstenedione, dehydroepiandrosterone sulfate, oestrone and anti-Mullerian hormone levels in female pwMS with SD. In male pwMS and SD, there was a significant decrease in inhibin B levels. CONCLUSIONS: Our findings highlight the requirement of a holistic approach to SD in MS including physical, neurourological and psychosocial factors. Active screening for SD, especially in patients with disability, depression or bladder and bowel dysfunction, is recommended.


Assuntos
Esclerose Múltipla , Disfunções Sexuais Fisiológicas , Humanos , Masculino , Feminino , Esclerose Múltipla/complicações , Qualidade de Vida , Depressão/epidemiologia , Disfunções Sexuais Fisiológicas/epidemiologia , Comportamento Sexual
5.
Clin Chem Lab Med ; 61(12): 2248-2255, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37401452

RESUMO

OBJECTIVES: Immune checkpoints play an important role in maintaining the balance of the immune system and in the development of autoimmune diseases. A central checkpoint molecule is the programmed cell death protein 1 (PD-1, CD279) which is typically located on the surface of T cells. Its primary ligand PD-L1 is expressed on antigen presenting cells and on cancer cells. Several variants of PD-L1 exist, among these soluble molecules (sPD-L1) present in serum at low concentrations. sPD-L1 was found elevated in cancer and several other diseases. sPD-L1 in infectious diseases has received relatively little attention so far and is therefore subject of this study. METHODS: sPD-L1 serum levels were determined in 170 patients with viral infections (influenza, varicella, measles, Dengue fever, SARS-CoV2) or bacterial sepsis by ELISA and compared to the levels obtained in 11 healthy controls. RESULTS: Patients with viral infections and bacterial sepsis generally show significantly higher sPD-L1 serum levels compared to healthy donors, except for varicella samples where results do not reach significance. sPD-L1 is increased in patients with impaired renal function compared to those with normal renal function, and sPD-L1 correlates significantly with serum creatinine. Among sepsis patients with normal renal function, sPD-L1 serum levels are significantly higher in Gram-negative sepsis compared to Gram-positive sepsis. In addition, in sepsis patients with impaired renal function, sPD-L1 correlates positively with ferritin and negatively with transferrin. CONCLUSIONS: sPD-L1 serum levels are significantly elevated in patients with sepsis, influenza, mesasles, Dengue fever or SARS-CoV2. Highest levels are detectable in patients with measles and Dengue fever. Also impaired renal function causes an increase in levels of sPD-L1. As a consequence, renal function has to be taken into account in the interpretation of sPD-L1 levels in patients.


Assuntos
Varicela , Dengue , Influenza Humana , Sarampo , Sepse , Humanos , Antígeno B7-H1/metabolismo , Doadores de Sangue , RNA Viral , Rim/fisiologia , Prognóstico
6.
Clin Chem Lab Med ; 61(7): 1349-1358, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36756735

RESUMO

OBJECTIVES: The WHO's standardized measuring unit, "binding antibody units per milliliter (BAU/mL)," should allow the harmonization of quantitative results by different commercial Anti-SARS-CoV-2 immunoassays. However, multiple studies demonstrate inter-assay discrepancies. The antigenic changes of the Omicron variant affect the performance of Spike-specific immunoassays. This study evaluated the variation of quantitative Anti-SARS-CoV-2-Spike antibody measurements among 46, 50, and 44 laboratories in three rounds of a national external quality assessment (EQA) prior to and after the emergence of the Omicron variant in a diagnostic near-to-real-life setting. METHODS: We analyzed results reported by the EQA participant laboratories from single and sequential samples from SARS-CoV-2 convalescent, acutely infected, and vaccinated individuals, including samples obtained after primary and breakthrough infections with the Omicron variant. RESULTS: The three immunoassays most commonly used by the participants displayed a low intra-assay and inter-laboratory variation with excellent reproducibility using identical samples sent to the participants in duplicates. In contrast, the inter-assay variation was very high with all samples. Notably, the ratios of BAU/mL levels quantified by different immunoassays were not equal among all samples but differed between vaccination, past, and acute infection, including primary infection with the Omicron variant. The antibody kinetics measured in vaccinated individuals strongly depended on the applied immunoassay. CONCLUSIONS: Measured BAU/mL levels are only inter-changeable among different laboratories when the same assay was used for their assessment. Highly variable ratios of BAU/mL quantifications among different immunoassays and infection stages argue against the usage of universal inter-assay conversion factors.


Assuntos
COVID-19 , Humanos , Reprodutibilidade dos Testes , COVID-19/diagnóstico , SARS-CoV-2 , Anticorpos Antivirais , Anticorpos Neutralizantes
7.
Clin Chem Lab Med ; 60(8): 1308-1312, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35599330

RESUMO

OBJECTIVES: Results of earlier external quality assessment (EQA) rounds suggested remarkable differences in the sensitivity of SARS-CoV PCR assays. Although the test systems are intended to detect SARS-CoV-2 in individual samples, screening is often applied to sample pools to increase efficiency and decrease costs. However, it is unknown to what extent these tests actually meet the manufacturer's specifications for sensitivity and how they perform when testing sample pools. METHODS: The sensitivity of assays in routine use was evaluated with a panel of positive samples in a round of a SARS-CoV-2 virus genome detection EQA scheme. The panel consisted of samples at or near the lower limit of detection ("weakly positive"). Laboratories that routinely test sample pools were asked to also analyze the pooled EQA samples according to their usual pool size and dilution method. RESULTS: All participants could detect a highly positive patient-derived sample (>106 copies/mL). Most (96%) of the test systems could detect at least 1,000 copies/mL, meeting the minimum acceptable benchmark, and many (94%) detected the vRNA in a sample with lower concentration (500 copies/mL). The false negative ratio increased to 16 and 26% for samples with 100 and 50 copies/mL, respectively. CONCLUSIONS: The performance of most assays met or exceeded their specification on sensitivity. If assays are to be used to analyze sample pools, the sensitivity of the assay and the number of pooled samples must be balanced.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , SARS-CoV-2/genética , Sensibilidade e Especificidade
8.
Clin Chem Lab Med ; 60(2): 291-298, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34751522

RESUMO

OBJECTIVES: Mutation-specific PCR assays have quickly found their way into laboratory diagnostics due to their capacity to be a fast, easy to implement and high-throughput method for the detection of known SARS-CoV-2 variants of concern (VoCs). However, little is known about the performance of such assays in routine laboratory analysis. METHODS: The results reported in a recent round of an external quality assessment (EQA) scheme for SARS-CoV-2 mutation-specific PCR were retrospectively analyzed. For the determination of individual variant-specific sequences as well as for the interpretation results for certain virus variants, correct, incorrect, and unreported results were evaluated, and their possible causes were investigated. RESULTS: A total of 34 laboratories participated in this study. For five samples containing the VoC Alpha + E484K, Beta, Gamma, Delta, or B.1.1.318 (as a variant of interest), 848 results for SARS-2-CoV mutation detection were reported, 824 (97.2%, range per sample 88-100%) of which were correct. Melting curve assays gave 99% correct results, real-time RT-qPCR 94%, microarray-based assays 100%, and MALDI-TOF MS 96%. A total of 122/167 (73%) reported results for SARS-CoV-2 variant determination were correct. Of the 45 inconclusive or incorrect results, 33 (73%) were due to inadequate selection of targets that did not allow identification of contemporary VoC, 11 (24%) were due to incorrect results, and one (3%) was due to correct results of mutation-specific PCR. CONCLUSIONS: Careful and up-to-date selection of the targets used in mutation-specific PCR is essential for successful detection of current SARS-CoV-2 variants.


Assuntos
COVID-19 , SARS-CoV-2/genética , COVID-19/virologia , Humanos , Mutação , Reação em Cadeia da Polimerase em Tempo Real , Estudos Retrospectivos
9.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
10.
BMC Cardiovasc Disord ; 22(1): 11, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35042472

RESUMO

BACKGROUND: In recent years, there has been increasing evidence that asthma is associated with atherosclerosis and cardiovascular disease. However, data in children and adolescents are scarce and conflicting. We aimed to assess the impact of asthma with and without an allergic component on the carotid intima-media thickness in a large pediatric population. METHODS: The community-based early vascular ageing-Tyrol cohort study was performed between May 2015 and July 2018 in North, East (Austria) and South Tyrol (Italy) and recruited youngster aged 14 years and above. Medical examinations included anthropometric measurements, fasting blood analysis, measurement of the carotid intima-media thickness by high-resolution ultrasound, and a physician guided interview. RESULTS: The mean age of the 1506 participants was 17.8 years (standard deviation 0.90). 851 (56.5%) participants were female. 22 subjects had a physician diagnosis of non-allergic asthma, 268 had inhalative allergies confirmed by a positive radio-allergo-sorbent-test and/or prick test, and 58 had allergic asthma. Compared to healthy controls, participants with non-allergic asthma (411.7 vs. 411.7 µm; p = 0.932) or inhalative allergy (420.0 vs. 411.7 µm; p = 0.118) did not have significantly higher carotid intima-media thickness (cIMT). However, participants with allergic asthma had significantly higher cIMT (430.8 vs. 411.7; p = 0.004) compared to those without and this association remained significant after multivariable adjustment for established cardiovascular risk factors. CONCLUSION: Allergic asthma in the youth is associated with an increased carotid intima-media thickness. Physicians should therefore be aware of allergic asthma as a potential cardiovascular risk factor in children and adolescents. Trial Registration Number The EVA-Tyrol Study has been retrospectively registered at clinicaltrials.gov under NCT03929692 since April 29, 2019.


Assuntos
Envelhecimento/fisiologia , Asma/complicações , Doenças Cardiovasculares/etiologia , Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Adolescente , Asma/diagnóstico , Asma/epidemiologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Criança , Feminino , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida/tendências
11.
BMC Cardiovasc Disord ; 22(1): 347, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35915405

RESUMO

BACKGROUND: Patients with ischaemic stroke or transient ischaemic attack (TIA) are at high risk of incident cardiovascular events and recurrent stroke. Despite compelling evidence about the efficacy of secondary prevention, a substantial gap exists between risk factor management in real life and that recommended by international guidelines. We conducted the STROKE-CARD trial (NCT02156778), a multifaceted pragmatic disease management program between 2014 and 2018 with follow-up until 2019. This program successfully reduced cardiovascular risk and improved health-related quality of life and functional outcome in patients with acute ischaemic stroke or TIA within 12 months after the index event. To investigate potential long-term effects of STROKE-CARD care compared to standard care, an extension of follow-up is warranted. METHODS: We aim to include all patients from the STROKE-CARD trial (n = 2149) for long-term follow-up between 2019 and 2021 with the study visit scheduled 3-6 years after the stroke/TIA event. The co-primary endpoint is the composite of major recurrent cardiovascular events (nonfatal stroke, nonfatal myocardial infarction, and vascular death) from hospital discharge until the long-term follow-up visit and health-related quality of life measured with the European Quality of Life-5 Dimensions (EQ-5D-3L) at the final visit. Secondary endpoints include overall mortality, long-term functional outcome, and target-level achievement in risk factor management. DISCUSSION: This long-term follow-up will provide evidence on whether the pragmatic post-stroke/TIA intervention program STROKE-CARD is capable of preventing recurrent cardiovascular events and improving quality-of-life in the long run. Trial registration clinicaltrials.gov: NCT04205006 on 19 December 2019.


Assuntos
Isquemia Encefálica , Doenças Cardiovasculares , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/complicações , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Fatores de Risco de Doenças Cardíacas , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/prevenção & controle , Qualidade de Vida , Fatores de Risco , Prevenção Secundária/métodos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle
12.
Antimicrob Agents Chemother ; 65(7): e0256520, 2021 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-33972242

RESUMO

The pharmacokinetics and antifungal activity of the echinocandins anidulafungin (AFG), micafungin (MFG), and caspofungin (CAS) were assessed in ascites fluid and plasma of critically ill adults treated for suspected or proven invasive candidiasis. Ascites fluid was obtained from ascites drains or during paracentesis. The antifungal activity of the echinocandins in ascites fluid was assessed by incubation of Candida albicans and Candida glabrata at concentrations of 0.03 to 16.00 µg/ml. In addition, ascites fluid samples obtained from our study patients were inoculated with the same isolates and evaluated for fungal growth. These patient samples had to be spiked with echinocandins to restore the original concentrations because echinocandins had been lost during sterile filtration. In ascites fluid specimens of 29 patients, echinocandin concentrations were below the simultaneous plasma levels. Serial sampling in 20 patients revealed a slower rise and decline of echinocandin concentrations in ascites fluid than in plasma. Proliferation of C. albicans in ascites fluid was slower than in culture medium and growth of C. glabrata was lacking, even in the absence of antifungals. In CAS-spiked ascites fluid samples, fungal CFU counts moderately declined, whereas spiking with AFG or MFG had no relevant effect. In ascites fluid of our study patients, echinocandin concentrations achieved by therapeutic doses did not result in a consistent eradication of C. albicans or C. glabrata. Thus, therapeutic doses of AFG, MFG, or CAS may result in ascites fluid concentrations preventing relevant proliferation of C. albicans and C. glabrata, but do not warrant reliable eradication.


Assuntos
Antifúngicos , Equinocandinas , Adulto , Antifúngicos/farmacologia , Antifúngicos/uso terapêutico , Ascite/tratamento farmacológico , Estado Terminal , Humanos , Lipopeptídeos , Testes de Sensibilidade Microbiana
13.
Infection ; 49(4): 747-755, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33877638

RESUMO

PURPOSE: Wound infections caused by Candida are life-threatening and difficult to treat. Echinocandins are highly effective against Candida species and recommended for treatment of invasive candidiasis. As penetration of echinocandins into wounds is largely unknown, we measured the concentrations of the echinocandins anidulafungin (AFG), micafungin (MFG), and caspofungin (CAS) in wound secretion (WS) and in plasma of critically ill patients. METHODS: We included critically ill adults with an indwelling wound drainage or undergoing vacuum-assisted closure therapy, who were treated with an echinocandin for suspected or proven invasive fungal infection. Concentrations were measured by liquid chromatography with UV (AFG and MFG) or tandem mass spectrometry detection (CAS). RESULTS: Twenty-one patients were enrolled. From eight patients, serial WS samples and simultaneous plasma samples were obtained within a dosage interval. AFG concentrations in WS amounted to < 0.025-2.25 mg/L, MFG concentrations were 0.025-2.53 mg/L, and CAS achieved concentrations of 0.18-4.04 mg/L. Concentrations in WS were significantly lower than the simultaneous plasma concentrations and below the MIC values of some relevant pathogens. CONCLUSION: Echinocandin penetration into WS displays a high inter-individual variability. In WS of some of the patients, concentrations may be sub-therapeutic. However, the relevance of sub-therapeutic concentrations is unknown as no correlation has been established between concentration data and clinical outcome. Nevertheless, in the absence of clinical outcome studies, our data do not support the use of echinocandins at standard doses for the treatment of fungal wound infections, but underline the pivotal role of surgical debridement.


Assuntos
Candidíase Invasiva , Equinocandinas , Adulto , Antifúngicos/uso terapêutico , Candidíase Invasiva/tratamento farmacológico , Estado Terminal , Humanos , Lipopeptídeos , Testes de Sensibilidade Microbiana
14.
Clin Chem Lab Med ; 59(10): 1735-1744, 2021 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-34187131

RESUMO

OBJECTIVES: External quality assessment (EQA) schemes provide information on individual and general analytical performance of participating laboratories and test systems. The aim of this study was to investigate the use and performance of SARS-CoV-2 virus genome detection systems in Austrian laboratories and their preparedness to face challenges associated with the pandemic. METHODS: Seven samples were selected to evaluate performance and estimate variability of reported results. Notably, a dilution series was included in the panel as a measure of reproducibility and sensitivity. Several performance criteria were evaluated for individual participants as well as in the cohort of all participants. RESULTS: A total of 109 laboratories participated and used 134 platforms, including 67 different combinations of extraction and PCR platforms and corresponding reagents. There were no false positives and 10 (1.2%) false negative results, including nine in the weakly positive sample (Ct ∼35.9, ∼640 copies/mL). Twenty (22%) laboratories reported results of mutation detection. Twenty-five (19%) test systems included amplification of human RNA as evidence of proper sampling. The overall linearity of Ct values from individual test systems for the dilution series was good, but inter-assay variability was high. Both operator-related and systematic failures appear to have caused incorrect results. CONCLUSIONS: Beyond providing certification for participating laboratories, EQA provides the opportunity for participants to evaluate their performance against others so that they may improve operating procedures and test systems. Well-selected EQA samples offer additional inferences to be made about assay sensitivity and reproducibility, which have practical applications.


Assuntos
COVID-19/diagnóstico , Genoma Viral , Garantia da Qualidade dos Cuidados de Saúde , SARS-CoV-2/isolamento & purificação , Áustria/epidemiologia , COVID-19/virologia , Humanos , Laboratórios , Técnicas de Diagnóstico Molecular/métodos , Pandemias , SARS-CoV-2/genética , Sensibilidade e Especificidade
15.
Clin Chem Lab Med ; 59(6): 1143-1154, 2021 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-33554557

RESUMO

OBJECTIVES: Serological tests detect antibodies against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in the ongoing coronavirus disease-19 (COVID-19) pandemic. Independent external clinical validation of performance characteristics is of paramount importance. METHODS: Four fully automated assays, Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, Siemens SARS-CoV-2 total (COV2T) and SARS-CoV-2 IgG (COV2G) were evaluated using 350 pre-pandemic samples and 700 samples from 245 COVID-19 patients (158 hospitalized, 87 outpatients). RESULTS: All tests showed very high diagnostic specificity. Sensitivities in samples collected at least 14 days after disease onset were slightly lower than manufacturers' claims for Roche (93.0%), Abbott (90.8%), and Siemens COV2T (90.3%), and distinctly lower for Siemens COV2G (78.8%). Concordantly negative results were enriched for immunocompromised patients. ROC curve analyses suggest a lowering of the cut-off index for the Siemens COV2G assay. Finally, the combination of two anti-SARS-CoV-2 antibody assays is feasible when considering borderline reactive results. CONCLUSIONS: Thorough on-site evaluation of commercially available serologic tests for detection of antibodies against SARS-CoV-2 remains imperative for laboratories. The potentially impaired sensitivity of the Siemens COV2G necessitates a switch to the company's newly filed SARS-CoV-2 IgG assay for follow-up studies. A combination of tests could be considered in clinical practice.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Imunoglobulina G/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/epidemiologia , Feminino , Humanos , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Pandemias , Curva ROC , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Adulto Jovem
16.
Clin Chem Lab Med ; 59(8): 1453-1462, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-33837679

RESUMO

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections cause coronavirus disease 2019 (COVID-19) and induce a specific antibody response. Serological assays detecting IgG against the receptor binding domain (RBD) of the spike (S) protein are useful to monitor the immune response after infection or vaccination. The objective of our study was to evaluate the clinical performance of the Siemens SARS-CoV-2 IgG (sCOVG) assay. METHODS: Sensitivity and specificity of the Siemens sCOVG test were evaluated on 178 patients with SARS-CoV-2-infection and 160 pre-pandemic samples in comparison with its predecessor test COV2G. Furthermore, correlation with virus neutralization titers was investigated on 134 samples of convalescent COVID-19 patients. RESULTS: Specificity of the sCOVG test was 99.4% and sensitivity was 90.5% (COV2G assay 78.7%; p<0.0001). S1-RBD antibody levels showed a good correlation with virus neutralization titers (r=0.843; p<0.0001) and an overall qualitative agreement of 98.5%. Finally, median S1-RBD IgG levels increase with age and were significantly higher in hospitalized COVID-19 patients (median levels general ward: 25.7 U/mL; intensive care: 59.5 U/mL) than in outpatients (3.8 U/mL; p<0.0001). CONCLUSIONS: Performance characteristics of the sCOVG assay have been improved compared to the predecessor test COV2G. Quantitative SARS-CoV-2 S1-RBD IgG levels could be used as a surrogate for virus neutralization capacity. Further harmonization of antibody quantification might assist to monitor the humoral immune response after COVID-19 disease or vaccination.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , Imunoglobulina G/imunologia , Testes de Neutralização , SARS-CoV-2/metabolismo , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/patologia , COVID-19/virologia , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Subunidades Proteicas/imunologia , Kit de Reagentes para Diagnóstico , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Adulto Jovem
17.
Clin Chem Lab Med ; 58(4): 618-624, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-31804953

RESUMO

Background Capillary B-type natriuretic peptide (BNP) testing is attractive in outpatient and emergency settings. The aim of this study was to perform an evaluation of the clinical performances of capillary BNP testing as compared with venous whole blood and plasma point-of-care (POC) BNP as well as plasma N-terminal (NT) proBNP central laboratory testing. Methods BNP was measured with a novel single epitope POC assay (Minicare® BV, Eindhoven, The Netherlands) and NT-proBNP with a central laboratory assay (Roche Diagnostics®, Vienna, Austria). Results BNP and NT-proBNP were measured in 269 patients of a Department of Cardiology (mean age 67.9 ± 13 years, 26.4% females). Capillary BNP very closely correlated with whole blood venous BNP (r = 0.99, p < 0.001). There was also a close correlation of plasma BNP and NT-proBNP concentrations (r = 0.79, p < 0.001). The diagnostic performances of capillary BNP, whole blood venous BNP, plasma BNP and plasma NT-proBNP for acute heart failure (areas under receiver operating characteristic curves [AUC ROC]: 0.73-0.77) or systolic left ventricular dysfunction in the whole study population (AUC ROC: 0.72-0.76) did not differ significantly. All were significant independent predictors of cardiovascular death during follow-up of the whole study population. Conclusions Our study for the first time demonstrated a very close correlation of capillary and venous whole blood or plasma BNP concentrations using the same BNP assay in a large patient cohort. The diagnostic performances of different BNP specimens did not differ significantly, and no significant differences between BNP and NT-proBNP were found either.


Assuntos
Microvasos/metabolismo , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Biomarcadores/sangue , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Curva ROC , Kit de Reagentes para Diagnóstico , Disfunção Ventricular Esquerda/diagnóstico
18.
BMC Cardiovasc Disord ; 20(1): 59, 2020 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-32024473

RESUMO

BACKGROUND: According to the World Health Organization, cardiovascular diseases (CVDs) are the leading non-communicable cause of death. Awareness of the individual risk profile is crucial to implement a healthy lifestyle and prevent CVDs. Multiple studies demonstrated that atherosclerosis, the main cause of CVDs, begins early in life. Therefore, it may be necessary to start prevention programs already in childhood. METHODS: The EVA-Tyrol study is a population-based non-randomized controlled trial that will prospectively enroll 2000 participants from high schools and training companies in North- and East-Tyrol (Austria) and South-Tyrol (Italy). Participants will be assigned to either an intervention (n = 1500) or a control (n = 500) group. Intervention group participants will be enrolled at the 10th school grade (mean age 15-16 years), undergo two examinations within a two-year interval, with follow-up at the 12th grade (mean ages 17-18 years). Control group participants will be enrolled at the 12th grade (mean age 17-18 years). Medical examination will include anthropometric measurements, comprehensive lifestyle and dietary questionnaires, a fasting blood sample, high-resolution ultrasound of the carotid arteries, and measurement of carotid-femoral pulse wave velocity. Active intervention will consist of (1) enhancing knowledge about CVDs, (2) individual medical counseling based on the results of the baseline examination, (3) an online health promotion tool and (4) involvement of participants in planning and implementation of health promotion projects. Effectiveness of the intervention will be assessed by comparing the proportion subjects with ideal health metrics as defined by the American Heart Association between study groups. DISCUSSION: This study aims to improve cardiovascular health in Tyrolean adolescents by demonstrating the efficacy of a multi-layer health promotion program and may yield novel insights into the prevalence of vascular risk conditions and mechanisms of early vascular pathologies in adolescents. TRIAL REGISTRATION: EVA-Tyrol has been retrospectively registered at clinicaltrials.gov under NCT03929692 since April 29, 2019.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Promoção da Saúde , Estilo de Vida Saudável , Comportamento de Redução do Risco , Serviços de Saúde Escolar , Adolescente , Comportamento do Adolescente , Fatores Etários , Áustria/epidemiologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Aconselhamento , Feminino , Comportamentos Relacionados com a Saúde , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Masculino , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados não Aleatórios como Assunto , Estudos Prospectivos , Fatores de Proteção , Fatores de Risco
20.
BMC Neurol ; 18(1): 187, 2018 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-30400876

RESUMO

BACKGROUND: Patients with ischaemic stroke or transient ischaemic attack (TIA) are at high risk of future cardiovascular events. Despite compelling evidence about the efficacy of secondary prevention, a substantial gap exists between risk factor management in real life and that recommended by international guidelines. Moreover, stroke is a leading cause of disability and morbidity which partly emerges from post-stroke complications. METHODS/DESIGN: We designed a block-randomised (2:1 ratio) open pragmatic trial [NCT02156778] with blinded outcome assessment comparing STROKE-CARD to usual post-stroke-patient care. STROKE-CARD is a multifaceted post-stroke disease management program with the objective of reducing recurrent cardiovascular events and improving quality of life in ischaemic stroke and TIA-patients. It combines intensified multi-domain secondary prevention, systematic detection and treatment of post-stroke complications, and patient self-empowerment. Enrolment of 2160 patients with acute ischaemic stroke or TIA (ABCD2-Score ≥ 3) is planned at two study centres in Austria. The co-primary efficacy endpoints are (i) the composite of major recurrent cardiovascular events (nonfatal stroke, nonfatal myocardial infarction, and vascular death) occurring within 12 months after the index event and (ii) one-year health-related quality-of-life measured with the European Quality of Life-5 Dimensions (EQ-5D-3 L) questionaire. Secondary endpoints include all-cause mortality, functional outcome, and target-level achievement in risk factor management. DISCUSSION: This trial will provide evidence on whether the pragmatic post-stroke intervention program STROKE-CARD can help prevent cardiovascular events and improve quality-of-life within the setting of a high-quality acute stroke care system. In case of success, STROKE-CARD may be implemented in daily clinical routine and serve as a model for other disease management initiatives. TRIAL REGISTRATION: ClinicalTrials.gov: NCT02156778 . (June 5, 2014, retrospectively registered).


Assuntos
Doenças Cardiovasculares/prevenção & controle , Ataque Isquêmico Transitório/terapia , Infarto do Miocárdio/prevenção & controle , Acidente Vascular Cerebral/terapia , Áustria , Doenças Cardiovasculares/mortalidade , Feminino , Humanos , Masculino , Infarto do Miocárdio/mortalidade , Avaliação de Resultados em Cuidados de Saúde , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária/métodos , Acidente Vascular Cerebral/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA