Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Chem Soc Rev ; 48(6): 1566-1595, 2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-30519703

RESUMO

Highly conductive and intrinsically stretchable electrodes are vital components of soft electronics such as stretchable transistors and circuits, sensors and actuators, light-emitting diode arrays, and energy harvesting devices. Many kinds of conducting nanomaterials with outstanding electrical and mechanical properties have been integrated with elastomers to produce stretchable conductive nanocomposites. Understanding the characteristics of these nanocomposites and assessing the feasibility of their fabrication are therefore critical for the development of high-performance stretchable conductors and electronic devices. We herein summarise the recent advances in stretchable conductors based on the percolation networks of nanoscale conductive fillers in elastomeric media. After discussing the material-, dimension-, and size-dependent properties of conductive fillers and their implications, we highlight various techniques that are used to reduce the contact resistance between the conductive filler materials. Furthermore, we categorize elastomer matrices with different stretchabilities and mechanical properties based on their polymeric chain structures. Then, we discuss the fabrication techniques of stretchable conductive nanocomposites toward their use in soft electronics. Finally, we provide representative examples of stretchable device applications and conclude the review with a brief outlook for future research.

2.
Angew Chem Int Ed Engl ; 57(30): 9408-9412, 2018 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-29862623

RESUMO

Oxidative stress induced by reactive oxygen species (ROS) is one of the critical factors that involves in the pathogenesis and progression of many diseases. However, lack of proper techniques to scavenge ROS depending on their cellular localization limits a thorough understanding of the pathological effects of ROS. Here, we demonstrate the selective scavenging of mitochondrial, intracellular, and extracellular ROS using three different types of ceria nanoparticles (NPs), and its application to treat Parkinson's disease (PD). Our data show that scavenging intracellular or mitochondrial ROS inhibits the microglial activation and lipid peroxidation, while protecting the tyrosine hydroxylase (TH) in the striata of PD model mice. These results indicate the essential roles of intracellular and mitochondrial ROS in the progression of PD. We anticipate that our ceria NP systems will serve as a useful tool for elucidating the functions of various ROS in diseases.


Assuntos
Cério/química , Sequestradores de Radicais Livres/química , Mitocôndrias/química , Nanopartículas/química , Doença de Parkinson/metabolismo , Espécies Reativas de Oxigênio/química , Linhagem Celular Tumoral , Sequestradores de Radicais Livres/metabolismo , Humanos , Hidrodinâmica , Mitocôndrias/metabolismo , Tamanho da Partícula , Espécies Reativas de Oxigênio/metabolismo , Propriedades de Superfície
3.
ACS Nano ; 18(19): 12025-12048, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38706306

RESUMO

Cardiac interfacing devices are essential components for the management of cardiovascular diseases, particularly in terms of electrophysiological monitoring and implementation of therapies. However, conventional cardiac devices are typically composed of rigid and bulky materials and thus pose significant challenges for effective long-term interfacing with the curvilinear surface of a dynamically beating heart. In this regard, the recent development of intrinsically soft bioelectronic devices using nanocomposites, which are fabricated by blending conductive nanofillers in polymeric and elastomeric matrices, has shown great promise. The intrinsically soft bioelectronics not only endure the dynamic beating motion of the heart and maintain stable performance but also enable conformal, reliable, and large-area interfacing with the target cardiac tissue, allowing for high-quality electrophysiological mapping, feedback electrical stimulations, and even mechanical assistance. Here, we explore next-generation cardiac interfacing strategies based on soft bioelectronic devices that utilize elastic conductive nanocomposites. We first discuss the conventional cardiac devices used to manage cardiovascular diseases and explain their undesired limitations. Then, we introduce intrinsically soft polymeric materials and mechanical restraint devices utilizing soft polymeric materials. After the discussion of the fabrication and functionalization of conductive nanomaterials, the introduction of intrinsically soft bioelectronics using nanocomposites and their application to cardiac monitoring and feedback therapy follow. Finally, comments on the future prospects of soft bioelectronics for cardiac interfacing technologies are discussed.


Assuntos
Nanoestruturas , Humanos , Nanoestruturas/química , Doenças Cardiovasculares/terapia , Condutividade Elétrica , Polímeros/química , Animais , Nanocompostos/química , Coração/fisiologia
4.
ACS Nano ; 17(8): 7550-7561, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37039606

RESUMO

Mechanically soft metallic nanocomposites have gained much attention as a key material for intrinsically stretchable biointegrated devices. However, it has been challenging to develop a stretchable conductive nanocomposite with all the desired material characteristics including high conductivity, high stretchability, low cytotoxicity, and low impedance. Here, we present a material strategy for the stretchable conductive nanocomposite, particularly emphasizing low impedance, by combining silver-gold-platinum core-shell-shell nanowires and homogeneously dispersed in situ synthesized platinum nanoparticles (Pt NPs). The highly embossed structure of the outermost Pt shell, together with the intrinsic electrical property of Pt, contributes to minimizing the impedance. The gold-platinum double-layer sheath prevents leaching of cytotoxic Ag ions, thus improving biocompatibility. Homogeneously dispersed Pt NPs, synthesized in situ during fabrication of the nanocomposite, simultaneously enhance conductivity, reduce impedance, and improve stretchability by supporting the percolation network formation. This intrinsically stretchable nanocomposite conductor can be applied to wearable and implantable bioelectronics for recording biosignals and delivering electrical stimulations in vivo.


Assuntos
Nanopartículas Metálicas , Nanofios , Dispositivos Eletrônicos Vestíveis , Nanofios/química , Impedância Elétrica , Nanopartículas Metálicas/química , Platina , Ouro/química
5.
Sci Adv ; 9(13): eadf6856, 2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37000879

RESUMO

The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multichannel electrode array, which does not disturb the normal contraction or electrical propagation of the ventricle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy subthreshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportunities toward the development of innovative methods for painless ICD therapy.


Assuntos
Desfibriladores Implantáveis , Infarto do Miocárdio , Taquicardia Ventricular , Coelhos , Animais , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Desfibriladores Implantáveis/efeitos adversos , Ventrículos do Coração , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Infarto do Miocárdio/terapia , Infarto do Miocárdio/etiologia
6.
ACS Nano ; 16(7): 10431-10442, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35766461

RESUMO

Noble metal nanomaterials have been studied as conductive fillers for stretchable, conductive, and biocompatible nanocomposites. However, their performance as conductive filler materials is far from ideal because of their high percolation threshold and low intrinsic conductivity. Moreover, the difficulty in large-scale production is another critical hurdle in their practical applications. Here we report a method for the facile and scalable synthesis of whiskered gold nanosheets (W-AuNSs) for stretchable, conductive, and biocompatible nanocomposites and their application to stretchable bioelectrodes. W-AuNSs show a lower percolation threshold (1.56 vol %) than those of gold nanoparticles (5.02 vol %) and gold nanosheets (2.74 vol %), which enables the fabrication of W-AuNS-based stretchable nanocomposites with superior conductivity and high stretchability. Addition of platinum-coated W-AuNSs (W-AuNSs@Pt) to the prepared nanocomposite significantly reduces the impedance and improved charge storage capacity. Such enhanced performance of the stretchable nanocomposite enables us to fabricate stretchable bioelectrodes whose performance is demonstrated through animal experiments including electrophysiological recording and electrical stimulation in vivo.


Assuntos
Nanopartículas Metálicas , Nanocompostos , Animais , Ouro , Condutividade Elétrica
7.
ACS Nano ; 16(2): 2535-2545, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35080370

RESUMO

An urgent need in chemodynamic therapy (CDT) is to achieve high Fenton catalytic efficiency at small doses of CDT agents. However, simple general promotion of the Fenton reaction increases the risk of damaging normal cells along with the cancer cells. Therefore, a tailored strategy to selectively enhance the Fenton reactivity in tumors, for example, by taking advantage of the characteristics of the tumor microenvironment (TME), is in high demand. Herein, a heterogeneous CDT system based on copper-iron peroxide nanoparticles (CFp NPs) is designed for TME-mediated synergistic therapy. CFp NPs degrade under the mildly acidic conditions of TME, self-supply H2O2, and the released Cu and Fe ions, with their larger portions at lower oxidation states, cooperatively facilitate hydroxyl radical production through a highly efficient catalytic loop to achieve an excellent tumor therapeutic efficacy. This is distinct from previous heterogeneous CDT systems in that the synergism is closely coupled with the Cu+-assisted conversion of Fe3+ to Fe2+ rather than their independent actions. As a result, almost complete ablation of tumors at a minimal treatment dose is demonstrated without the aid of any other therapeutic modality. Furthermore, CFp NPs generate O2 during the catalysis and exhibit a TME-responsive T1 magnetic resonance imaging contrast enhancement, which are useful for alleviating hypoxia and in vivo monitoring of tumors, respectively.


Assuntos
Nanopartículas , Neoplasias , Linhagem Celular Tumoral , Humanos , Peróxido de Hidrogênio , Neoplasias/tratamento farmacológico , Peróxidos , Microambiente Tumoral
8.
Science ; 373(6558): 1022-1026, 2021 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-34446604

RESUMO

Skin electronics require stretchable conductors that satisfy metallike conductivity, high stretchability, ultrathin thickness, and facile patternability, but achieving these characteristics simultaneously is challenging. We present a float assembly method to fabricate a nanomembrane that meets all these requirements. The method enables a compact assembly of nanomaterials at the water-oil interface and their partial embedment in an ultrathin elastomer membrane, which can distribute the applied strain in the elastomer membrane and thus lead to a high elasticity even with the high loading of the nanomaterials. Furthermore, the structure allows cold welding and bilayer stacking, resulting in high conductivity. These properties are preserved even after high-resolution patterning by using photolithography. A multifunctional epidermal sensor array can be fabricated with the patterned nanomembranes.

9.
Adv Mater ; 33(20): e2007346, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33739558

RESUMO

Soft neuroprosthetics that monitor signals from sensory neurons and deliver motor information can potentially replace damaged nerves. However, achieving long-term stability of devices interfacing peripheral nerves is challenging, since dynamic mechanical deformations in peripheral nerves cause material degradation in devices. Here, a durable and fatigue-resistant soft neuroprosthetic device is reported for bidirectional signaling on peripheral nerves. The neuroprosthetic device is made of a nanocomposite of gold nanoshell (AuNS)-coated silver (Ag) flakes dispersed in a tough, stretchable, and self-healing polymer (SHP). The dynamic self-healing property of the nanocomposite allows the percolation network of AuNS-coated flakes to rebuild after degradation. Therefore, its degraded electrical and mechanical performance by repetitive, irregular, and intense deformations at the device-nerve interface can be spontaneously self-recovered. When the device is implanted on a rat sciatic nerve, stable bidirectional signaling is obtained for over 5 weeks. Neural signals collected from a live walking rat using these neuroprosthetics are analyzed by a deep neural network to predict the joint position precisely. This result demonstrates that durable soft neuroprosthetics can facilitate collection and analysis of large-sized in vivo data for solving challenges in neurological disorders.


Assuntos
Nervo Isquiático , Animais , Eletrodos Implantados , Nanocompostos , Polímeros , Ratos
10.
Adv Mater ; 32(31): e2001566, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32520432

RESUMO

Nanomaterials with antioxidant properties are promising for treating reactive oxygen species (ROS)-related diseases. However, maintaining efficacy at low doses to minimize toxicity is a critical for clinical applications. Tuning the surface strain of metallic nanoparticles can enhance catalytic reactivity, which has rarely been demonstrated in metal oxide nanomaterials. Here, it is shown that inducing surface strains of CeO2 /Mn3 O4 nanocrystals produces highly catalytic antioxidants that can protect tissue-resident stem cells from irradiation-induced ROS damage. Manganese ions deposited on the surface of cerium oxide (CeO2 ) nanocrystals form strained layers of manganese oxide (Mn3 O4 ) islands, increasing the number of oxygen vacancies. CeO2 /Mn3 O4 nanocrystals show better catalytic activity than CeO2 or Mn3 O4 alone and can protect the regenerative capabilities of intestinal stem cells in an organoid model after a lethal dose of irradiation. A small amount of the nanocrystals prevents acute radiation syndrome and increases the survival rate of mice treated with a lethal dose of total body irradiation.


Assuntos
Antioxidantes/química , Cério/química , Compostos de Manganês/química , Nanopartículas Metálicas/química , Óxidos/química , Protetores contra Radiação/química , Animais , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Duodeno/metabolismo , Duodeno/efeitos da radiação , Raios gama , Humanos , Antígeno Ki-67/metabolismo , Camundongos , Modelos Biológicos , Protetores contra Radiação/farmacologia , Espécies Reativas de Oxigênio/química , Espécies Reativas de Oxigênio/metabolismo , Células-Tronco/citologia , Células-Tronco/metabolismo , Irradiação Corporal Total
11.
Nanoscale ; 11(41): 19437-19447, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31475711

RESUMO

Neuropathic pain is a chronic and pathological pain caused by injury or dysfunction in the nervous system. Pro-inflammatory microglial activation with aberrant reactive oxygen species (ROS) generation in the spinal cord plays a critical role in the development of neuropathic pain. However, the efficacy of current therapeutic methods for neuropathic pain is limited because only neurons or neural circuits involved in pain transmission are targeted. Here, an effective strategy to treat pain hypersensitivity using microglia-targeting ceria-zirconia nanoparticles (CZ NPs) is reported. The CZ NPs are coated with microglia-specific antibodies to promote their delivery to microglia, and thus to improve their therapeutic efficacy. The targeted delivery facilitates the elimination of both pro-inflammatory cytokines and ROS in microglia, enabling the rapid and effective inhibition of microglial activation. As a result, greatly ameliorated mechanical allodynia is achieved in a spinal nerve transection (SNT)-induced neuropathic pain mouse model, proving the potent analgesic effect of the microglia-targeting CZ NPs. Given the generality of the approach used in this study, the microglia-targeting CZ NPs are expected to be useful for the treatment of not only neuropathic pain but also other neurological diseases associated with the vicious activation of microglia.


Assuntos
Analgésicos , Cério , Microglia , Nanopartículas , Neuralgia , Zircônio , Analgésicos/química , Analgésicos/farmacologia , Animais , Cério/química , Cério/farmacologia , Modelos Animais de Doenças , Masculino , Camundongos , Microglia/metabolismo , Microglia/patologia , Nanopartículas/química , Nanopartículas/uso terapêutico , Neuralgia/tratamento farmacológico , Neuralgia/metabolismo , Neuralgia/patologia , Zircônio/química , Zircônio/farmacologia
12.
Nat Nanotechnol ; 13(11): 1048-1056, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30104619

RESUMO

Wearable and implantable devices require conductive, stretchable and biocompatible materials. However, obtaining composites that simultaneously fulfil these requirements is challenging due to a trade-off between conductivity and stretchability. Here, we report on Ag-Au nanocomposites composed of ultralong gold-coated silver nanowires in an elastomeric block-copolymer matrix. Owing to the high aspect ratio and percolation network of the Ag-Au nanowires, the nanocomposites exhibit an optimized conductivity of 41,850 S cm-1 (maximum of 72,600 S cm-1). Phase separation in the Ag-Au nanocomposite during the solvent-drying process generates a microstructure that yields an optimized stretchability of 266% (maximum of 840%). The thick gold sheath deposited on the silver nanowire surface prevents oxidation and silver ion leaching, making the composite biocompatible and highly conductive. Using the nanocomposite, we successfully fabricate wearable and implantable soft bioelectronic devices that can be conformally integrated with human skin and swine heart for continuous electrophysiological recording, and electrical and thermal stimulation.

13.
ACS Nano ; 11(8): 8448-8455, 2017 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-28787118

RESUMO

Colloidal assemblies of nanoparticles possess both the intrinsic and collective properties of their constituent nanoparticles, which are useful in applications where ordinary nanoparticles are not well suited. Here, we report an immunoassay technique based on colloidal nanoparticle assemblies made of iron oxide nanoparticles (magnetic substrate) and manganese-doped zinc sulfide (ZnS:Mn) nanoparticles (photoluminescent substrate), both of which are functionalized with antibodies to capture target proteins in a sandwich assay format. After magnetic isolation of the iron oxide nanoparticle assemblies and their bound ZnS:Mn nanoparticle assemblies (MZSNAs), photoluminescence of the remaining MZSNAs is measured for the protein quantification, eliminating the need for washing steps and signal amplification. Using human C-reactive protein as a model biomarker, we achieve a detection limit of as low as 0.7 pg/mL, which is more than 1 order of magnitude lower than that of enzyme-linked immunosorbent assay (9.1 pg/mL) performed using the same pair of antibodies, while using only one-tenth of the antibodies. We also confirm the potential for multiplex detection by using two different types of photoluminescent colloidal nanoparticle assemblies simultaneously.


Assuntos
Coloides/química , Imunoensaio/métodos , Magnetismo , Nanopartículas/química , Ensaio de Imunoadsorção Enzimática
14.
Nat Commun ; 8: 15807, 2017 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-28722024

RESUMO

Tissue adhesives have emerged as an alternative to sutures and staples for wound closure and reconnection of injured tissues after surgery or trauma. Owing to their convenience and effectiveness, these adhesives have received growing attention particularly in minimally invasive procedures. For safe and accurate applications, tissue adhesives should be detectable via clinical imaging modalities and be highly biocompatible for intracorporeal procedures. However, few adhesives meet all these requirements. Herein, we show that biocompatible tantalum oxide/silica core/shell nanoparticles (TSNs) exhibit not only high contrast effects for real-time imaging but also strong adhesive properties. Furthermore, the biocompatible TSNs cause much less cellular toxicity and less inflammation than a clinically used, imageable tissue adhesive (that is, a mixture of cyanoacrylate and Lipiodol). Because of their multifunctional imaging and adhesive property, the TSNs are successfully applied as a hemostatic adhesive for minimally invasive procedures and as an immobilized marker for image-guided procedures.


Assuntos
Nanopartículas/química , Adesivos Teciduais/química , Animais , Bovinos , Células HeLa , Humanos , Fígado/cirurgia , Masculino , Coelhos , Ratos , Ratos Sprague-Dawley , Cirurgia Assistida por Computador , Adesivos Teciduais/síntese química
15.
Chem Commun (Camb) ; 49(42): 4779-81, 2013 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-23595312

RESUMO

Highly active magnetically recyclable hollow nanocomposite catalysts with a permeable carbon surface have been prepared by a simple, economical and scalable process. The designed nanocomposite exhibited excellent catalytic activities in the selective reduction of nitroarenes and Suzuki cross-coupling reactions. The catalysts could be easily separated by a magnet, and recycled consecutively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA