1.
J Arthroplasty ; 39(5): 1178-1183, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38336303

RESUMO

BACKGROUND: The anticipated growth of total hip arthroplasty will result in an increased need for revision total hip arthroplasty. Preoperative planning, including identifying current implants, is critical for successful revision surgery. Artificial intelligence (AI) is promising for aiding clinical decision-making, including hip implant identification. However, previous studies have limitations such as small datasets, dissimilar stem designs, limited scalability, and the need for AI expertise. To address these limitations, we developed a novel technique to generate large datasets, tested radiographically similar stems, and demonstrated scalability utilizing a no-code machine learning solution. METHODS: We trained, validated, and tested an automated machine learning-implemented convolutional neural network to classify 9 radiographically similar femoral implants with a metaphyseal-fitting wedge taper design. Our novel technique uses computed tomography-derived projections of a 3-dimensional scanned implant model superimposed within a computed tomography pelvis volume. We employed computer-aided design modeling and MATLAB to process and manipulate the images. This generated 27,020 images for training (22,957) and validation (4,063) sets. We obtained 786 test images from various sources. The performance of the model was evaluated by calculating sensitivity, specificity, and accuracy. RESULTS: Our machine learning model discriminated the 9 implant models with a mean accuracy of 97.4%, sensitivity of 88.4%, and specificity of 98.5%. CONCLUSIONS: Our novel hip implant detection technique accurately identified 9 radiographically similar implants. The method generates large datasets, is scalable, and can include historic or obscure implants. The no-code machine learning model demonstrates the feasibility of obtaining meaningful results without AI expertise, encouraging further research in this area.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Inteligência Artificial , Artroplastia de Quadril/métodos , Aprendizado de Máquina , Redes Neurais de Computação
2.
J Arthroplasty ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604279

RESUMO

BACKGROUND: Tibial bone defects are commonly encountered in revision total knee arthroplasty (rTKA) and can be managed with metaphyseal cones or sleeves. Few studies have directly compared tibial cones and sleeves in rTKA, and none have limited this comparison to the most severe tibial defects. The purpose of this study was to evaluate and compare the outcomes of metaphyseal cones and sleeves for tibial reconstruction in rTKA regarding implant fixation and clinical outcomes. METHODS: A retrospective review was conducted on patients undergoing rTKA in which metaphyseal cones or sleeves were utilized for addressing metaphyseal bone loss (34 cones and 18 sleeves). Tibial bone loss was classified according to the Anderson Orthopaedic Research Institute bone defect classification, with types 2B and 3 being included. Patient-reported outcomes and postoperative complications were collected, and a radiographic evaluation of osseointegration or loosening was performed. RESULTS: There were 52 knees included (34 cones, 18 sleeves), with a median follow-up of 41.0 months. All-cause implant survival was 100% at 2 years and 96% (95% confidence interval: 76 to 99%) at 4 years, with 98% of tibial components demonstrating osseointegration at the final follow-up. During follow-up, there were a total 11 revisions, of which 1 sleeve was revised secondary to implant loosening. Tibial sleeves had a higher risk of revision compared to tibial cones (P < .01), and sleeves fixed with a hybrid technique were more likely to need revision than cones fixed by the same method (P = .01). CONCLUSIONS: Porous metaphyseal tibial cones and tibial metaphyseal sleeves both performed well at a 41-month median follow-up with no difference in aseptic survivorship between the 2 constructs. Both demonstrate high rates of osseointegration, low rates of aseptic failure, and significant improvement in Knee Society Scores in patients with severe tibial defects in rTKA.

3.
J Arthroplasty ; 38(7S): S265-S273, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37105329

RESUMO

BACKGROUND: Larger head-to-neck ratio of dual mobility (DM) hip arthroplasties provide greater range of motion/less risk of dislocation, but raise concerns for high wear and friction. We measured in vitro, the wear rates of contemporary DM hips with highly cross-linked ultra high molecular weight polyethylene (UHWMPE), where it came from, and their frictional torques. METHODS: Hip simulators were used to compare the wear of DM to fixed-bearing (FB) designs of 2 different implants. Each of 8 different configurations underwent millions of simulated walking cycle tests, some as full DM, some as FB controls, some DM with the outer-articulation deliberately immobilized, and some the inner. Wear and 3-dimensional-frictional torques were measured and friction independent of size was deduced. RESULTS: The DM hips produced lower wear and friction-torque than the FB hips. The DM wear during walking gait comes mostly from the smaller inner articular surface. If the outer surface was immobilized, the wear and torque of the inner alone would be small, but the full DM (inner and outer free-to-move) wear and torque were smallest of all. Friction measurements expectedly showed larger hips having higher frictional torques, but the DM showed the lowest, again because its motion was mostly the smaller inner articulation; smaller than even a modern fixed-bearing hip. CONCLUSION: The DM hips appear to combine the benefits of greater range of motion and less impingement of larger hips, with the lower wear and friction of smaller FB hips, with some benefits compromised if the outer or inner articulations are immobilized.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Desenho de Prótese , Fricção , Falha de Prótese
4.
J Arthroplasty ; 38(6S): S326-S330, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36813212

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) is a devastating complication of knee and hip arthroplasty. Past literature has shown that gram-positive bacteria are commonly responsible for these infections, although limited research exists studying the changes in the microbial profile of PJIs over time. This study sought to analyze the incidence and trends of pathogens responsible for PJI over three decades. METHODS: This is a multi-institutional retrospective review of patients who had a knee or hip PJI from 1990 to 2020. Patients with a known causative organism were included and those with insufficient culture sensitivity data were excluded. There were 731 eligible joint infections from 715 patients identified. Organisms were divided into multiple categories based on genus/species and 5-year increments were used to analyze the study period. The Cochran-Armitage trend tests were used to evaluate linear trends in microbial profile over time and a P-value <.05 was considered statistically significant. RESULTS: There was a statistically significant positive linear trend in the incidence of methicillin-resistant Staphylococcus aureus over time (P = .0088) as well as a statistically significant negative linear trend in the incidence of coagulase-negative staphylococci over time (P = .0018). There was no statistical significance between organism and affected joint (knee/hip). CONCLUSION: The incidence of methicillin-resistant Staphylococcus aureus PJI is increasing over time, whereas, coagulase-negative staphylococci PJI is decreasing, paralleling the global trend of antibiotic resistance. Identifying these trends may help with the prevention and treatment of PJI through methods such as remodeling perioperative protocols, modifying prophylactic/empiric antimicrobial approaches, or transitioning to alternative therapeutic strategies.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Staphylococcus aureus Resistente à Meticilina , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Humanos , Artroplastia de Quadril/efeitos adversos , Incidência , Coagulase/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Estudos Retrospectivos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/tratamento farmacológico , Antibacterianos/uso terapêutico , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/tratamento farmacológico
5.
J Arthroplasty ; 37(7S): S674-S677, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35283230

RESUMO

BACKGROUND: Two-stage reimplantation is an effective treatment for periprosthetic joint infection (PJI). Many factors are involved in the variable success of this procedure. The purpose of this study is to examine the relationship between patient risk factors, comorbidities, and the pathogen on reinfection rates following two-stage reimplantation. METHODS: We evaluated 158 patients treated for PJI from 2008-2019. Only patients who had completed a two-stage exchange were included. Patient demographics, comorbidities, laboratory values, time-to-reimplantation, pathogen, antibiotic sensitivities, host status, and reinfection rates were assessed. Multivariate analysis was performed to identify correlation between risk factors and reinfection. A P-value < .05 was considered statistically significant. RESULTS: 31 patients experienced a reinfection (19.6%). There was a statistically significant association between infection with Methicillin Sensitive Staphylococcus Aureus (MSSA) and reinfection (P = .046). Patients with a reinfection also had a significantly greater median serum C-reactive protein (CRP) level (12.65 g/dL) at the time of diagnosis compared to patients without a reinfection (5.0 g/dL) (P = .010). Median Erythrocyte Sedimentation Rate (ESR) (56 in no re-infection and 69 in re-infection) and time-to-reimplantation (101 days in no reinfection and 141 days in reinfection) demonstrated a trend toward an association with re-infection but were not statistically significant (P = .055 and P = .054 respectively). CONCLUSION: As the number of arthroplasties continue to rise, PJIs are increasing proportionately and represent a significant revision burden. Elevated C-reactive protein (CRP) levels and Methicillin Sensitive Staphylococcus aureus (MSSA) infection were strongly associated with failure of a two-stage reimplantation. While not statistically significant with our numbers, there were strong trends toward an association between elevated Erythrocyte Sedimentation Rate (ESR), longer time-to-reimplantation, and reinfection.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Reinfecção , Reimplante , Infecções Estafilocócicas , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Artrite Infecciosa/etiologia , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Proteína C-Reativa/análise , Humanos , Meticilina/farmacologia , Meticilina/uso terapêutico , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Reoperação , Estudos Retrospectivos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/etiologia
6.
J Arthroplasty ; 35(5): 1214-1221.e5, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31948811

RESUMO

BACKGROUND: Hip and knee arthroplasties are among the most commonly performed surgical procedures in the elderly. In this age group, uncertainty exists regarding the importance of mild to moderate chronic kidney disease (CKD), which is prevalent but often unrecognized in the perioperative setting. This study evaluates the association between mild to moderate CKD and adverse postoperative outcomes in patients 65 years or older METHODS: This retrospective study selected patients 65 years or older undergoing hip or knee arthroplasty between 2006 and 2016 from the National Surgical Quality Improvement Program database. We created logistic regression models to analyze the relationship between CKD stage and each of our coprimary outcomes. The primary outcomes were major complication and mortality occurring within 30 days of surgery. RESULTS: Of the 193,747 included patients, 68,424 (35.3%) underwent hip and 125,323 (64.7%) knee arthroplasty. Within 30 days of surgery, 12,767 patients (6.6%) experienced a major complication and 352 (0.2%) died. Compared to patients with no kidney disease, patients with CKD stages 3b and 4 were at higher risk for both major complication (adjusted odds ratio [aOR] 1.28 [1.08-1.52], aOR 1.5 [1.13-1.98], respectively) and mortality (aOR 3.17 [1.23-8.14], aOR 3.93 [1.26-12.21], respectively) after hip arthroplasty, and for major complication (aOR 1.42 [1.23-1.63], aOR 1.52 [1.19-1.93], respectively) after knee arthroplasty. CONCLUSION: Among elderly patients, stage 3b and stage 4 CKD were associated with 30-day postoperative major complication after hip or knee arthroplasty, and with 30-day postoperative mortality after hip, but not knee, arthroplasty. Further research will be required to inform perioperative management decisions.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Insuficiência Renal Crônica , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Insuficiência Renal Crônica/epidemiologia , Estudos Retrospectivos
7.
Nanomedicine ; 14(7): 2271-2282, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30076934

RESUMO

Delayed fracture union is a significant clinical challenge in orthopedic practice. There are few non-surgical therapeutic options for this pathology. To address this challenge, we have developed a bone-targeting liposome (BTL) formulation of salvianic acid A (SAA), a potent bone anabolic agent, for improved treatment of delayed fracture union. Using pyrophosphorylated cholesterol as the targeting ligand, the liposome formulation (SAA-BTL) has demonstrated strong affinity to hydroxyapatite in vitro, and to bones in vivo. Locally administered SAA-BTL was found to significantly improve fracture callus formation and micro-architecture with accelerated mineralization rate in callus when compared to the dose equivalent SAA, non-targeting SAA liposome (SAA-NTL) or no treatment on a prednisone-induced delayed fracture union mouse model. Biomechanical analyses further validated the potent therapeutic efficacy of SAA-BTL. These results support SAA-BTL formulation, as a promising therapeutic candidate, to be further developed into an effective and safe clinical treatment for delayed bone fracture union.


Assuntos
Ácidos Cafeicos/farmacologia , Consolidação da Fratura/efeitos dos fármacos , Fraturas Ósseas/tratamento farmacológico , Lactatos/farmacologia , Lipossomos/administração & dosagem , Osteogênese , Inibidores da Bomba de Prótons/farmacologia , Animais , Anti-Inflamatórios/toxicidade , Ácidos Cafeicos/química , Colesterol/metabolismo , Modelos Animais de Doenças , Composição de Medicamentos , Feminino , Fraturas Ósseas/induzido quimicamente , Lactatos/química , Lipossomos/química , Camundongos , Prednisona/toxicidade , Inibidores da Bomba de Prótons/química
8.
J Immunol ; 194(8): 3861-3872, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25762781

RESUMO

Staphylococcus aureus is a leading cause of human prosthetic joint infections (PJIs) typified by biofilm formation. We recently identified a critical role for myeloid-derived suppressor cells (MDSCs) in S. aureus biofilm persistence. Proinflammatory signals induce MDSC recruitment and activation in tumor models; however, the mechanisms responsible for MDSC homing to sites of biofilm infection are unknown. In this study, we report that several cytokines (IL-12p40, IL-1ß, TNF-α, and G-CSF) and chemokines (CXCL2, CCL5) were significantly elevated in a mouse model of S. aureus PJI. This coincided with significantly increased MDSC infiltrates concomitant with reduced monocyte, macrophage, and T cell influx compared with uninfected animals. Of the cytokines detected, IL-12 was of particular interest based on its ability to possess either pro- or anti-inflammatory effects mediated through p35-p40 heterodimers or p40 homodimers, respectively. MDSC recruitment was significantly reduced in both p40 and p35 knockout mice, which resulted in enhanced monocyte and neutrophil influx and bacterial clearance. Adoptive transfer of wild-type MDSCs into infected p40 knockout animals worsened disease outcome, as evidenced by the return of S. aureus burdens to levels typical of wild-type mice. Tissues obtained from patients undergoing revision surgery for PJI revealed similar patterns of immune cell influx, with increased MDSC-like cells and significantly fewer T cells compared with aseptic revisions. These findings reveal a critical role for IL-12 in shaping the anti-inflammatory biofilm milieu by promoting MDSC recruitment.


Assuntos
Subunidade p35 da Interleucina-12/imunologia , Subunidade p40 da Interleucina-12/imunologia , Monócitos/imunologia , Procedimentos Ortopédicos/efeitos adversos , Próteses e Implantes , Infecções Relacionadas à Prótese/imunologia , Infecções Estafilocócicas/imunologia , Staphylococcus aureus/fisiologia , Animais , Biofilmes , Modelos Animais de Doenças , Humanos , Subunidade p35 da Interleucina-12/genética , Subunidade p40 da Interleucina-12/genética , Masculino , Camundongos , Camundongos Knockout , Monócitos/patologia , Infiltração de Neutrófilos/genética , Infiltração de Neutrófilos/imunologia , Neutrófilos/imunologia , Neutrófilos/patologia , Infecções Relacionadas à Prótese/genética , Infecções Relacionadas à Prótese/patologia , Infecções Estafilocócicas/genética , Infecções Estafilocócicas/patologia
9.
Clin Orthop Relat Res ; 475(1): 56-61, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27387759

RESUMO

BACKGROUND: Many patients develop recurrent periprosthetic joint infection after two-stage exchange arthroplasty of the hip or knee. One potential but insufficiently tested strategy to decrease the risk of persistent or recurrent infection is to administer additional antibiotics after the second-stage reimplantation. QUESTIONS/PURPOSES: (1) Does a 3-month course of oral antibiotics decrease the risk of failure secondary to infection after a two-stage exchange? (2) Are there any complications related to the administration of oral antibiotics after a two-stage exchange? (3) In those patients who develop a reinfection, is the infecting organism different from the initial infection? METHODS: Patients at seven centers randomized to receive 3 months of oral antibiotics or no further antibiotic treatment after operative cultures after the second-stage reimplantation were negative. Adult patients undergoing two-stage hip or knee revision arthroplasty for a periprosthetic infection who met Musculoskeletal Infection Society (MSIS) criteria for infection at the first stage were included. Oral antibiotic therapy was tailored to the original infecting organism(s) in consultation with an infectious disease specialist. MSIS criteria as used by the treating surgeon defined failure. Surveillance of patients for complications, including reinfection, occurred at 3 weeks, 6 weeks, 3 months, 12 months, and 24 months. If an organism demonstrated the same antibiotic sensitivities as the original organism, it was considered the same organism; no DNA subtyping was performed. Analysis was performed as intent to treat with all randomized patients included in the groups to which they were randomized. A log-rank survival curve was used to analyze the primary outcome of reinfection. At planned interim analysis (enrollment is ongoing), 59 patients were successfully randomized to the antibiotic group and 48 patients to the control group. Fifty-seven patients had an infection after TKA and 50 after a THA. There was no minimum followup for inclusion in this analysis. The mean followup was 14 months in the antibiotic group and 10 months in the control group. RESULTS: Patients treated with oral antibiotics failed secondary to infection less frequently than those not treated with antibiotics (5% [three of 59] versus 19% [nine of 48]; hazard ratio, 4.37; 95% confidence interval, 1.297-19.748; p = 0.016). Three patients had an adverse reaction to the oral antibiotics severe enough to cause them to stop taking the antibiotics early, and four patients who were randomized to that group did not take the antibiotics as directed. With the numbers available, there were no differences between the study groups in terms of the likelihood that an infection after treatment would be with a new organism (eight of nine in the control group versus one of three in the treatment group, p = 0.087). CONCLUSIONS: This multicenter randomized trial suggests that at short-term followup, the addition of 3 months of oral antibiotics appeared to improve infection-free survival. As a planned interim analysis, however, these results may change as the study reaches closure and the safety profile may yet prove risky. Further followup of this cohort of patients will be necessary to determine whether these preliminary results are durable over time. LEVEL OF EVIDENCE: Level I, therapeutic study.


Assuntos
Antibacterianos/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Administração Oral , Idoso , Antibacterianos/administração & dosagem , Distinções e Prêmios , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/etiologia , Recidiva , Reoperação , Prevenção Secundária , Resultado do Tratamento
12.
Clin Orthop Relat Res ; 473(12): 3829-35, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26122983

RESUMO

BACKGROUND: Patients 50 years or younger are at high risk for wear-related complications of their total hip arthroplasty (THA) because of their generally higher levels of activity. Highly crosslinked polyethylene (HXLPE) is believed to be more durable for this population than conventional polyethylene because of its improved wear; however, limited information is available on the wear of HXLPE in this population, particularly the wear of HXLPE when it articulates with alternative bearings like Oxinium (Smith & Nephew, Memphis, TN, USA). QUESTIONS/PURPOSES: The purpose of this study was to evaluate two questions relative to this population of patients undergoing THA. First, what was the linear and volumetric wear rate of HXLPE in patients 50 years or younger at a minimum followup of 9 years and was osteolysis observed in any of these hips? Given the potential for damage to the Oxinium femoral head surface, was the wear of HXLPE in the patients with this material similar to the other bearings or was there accelerated or runaway wear that was visible in any of the patients? METHODS: From November 1999 to April 2005, 105 THAs were performed in 95 patients 50 years of age or younger (mean, 42 years; range, 20-50 years). The mean body mass index was 30 kg/m(2) (range, 17-51 kg/m(2)).The mean followup was 12 years (range, 9-14 years). Two patients died, five patients (one bilateral) were lost to followup, and one hip was revised elsewhere for pain. The patients' information was not included in the study, which left 87 patients with 96 hips for analysis. Highly crosslinked polyethylene was the acetabular bearing for all of the hips. We analyzed the linear and volumetric wear of all of the hips using the Martell method. Eighty hips had the same diameter head (28 mm) allowing us to more accurately compare the different bearing materials. The type of femoral head used was related to our sequential use of materials beginning with cobalt chrome (14), ceramic (23) followed by Oxinium (43) in the hips with 28-mm heads. Although cobalt-chrome was used early in this study, our previous experience with ceramic on polyethylene encouraged us to use it as an alternative bearing. The Oxinium was used consecutively for the remaining hips. RESULTS: The mean wear of the HXLPE after 1 year of bedding-in (true linear wear)was 0.022 mm/year (95% confidence interval [CI], 0.015-0.030 mm/year). The mean volumetric wear of HXLPE after 1 year of bedding-in (true volumetric wear) was 9 mm(3)/year (95% CI, 4-14 mm(3)/year). None of the hip radiographs had evidence of loosening or osteolysis. Wear was not associated with femoral head material (p = 0.58 for linear wear/year versus head material and p = 0.52 for volumetric wear/year versus head material). CONCLUSIONS: In our study of patients 50 years of age or younger undergoing THA, the linear and volumetric wear rates of HXLPE were very low regardless of the bearing surface material. The laboratory concerns of Oxinium surface damage are serious but at this time we have not seen high wear of the HXLPE or osteolysis in this population. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Reagentes de Ligações Cruzadas/química , Articulação do Quadril/cirurgia , Prótese de Quadril , Polietileno/química , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Cerâmica/química , Ligas de Cromo/química , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Peso Molecular , Osteólise/etiologia , Desenho de Prótese , Falha de Prótese , Radiografia , Fatores de Risco , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Clin Orthop Relat Res ; 472(1): 212-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23813180

RESUMO

BACKGROUND: Rotational malalignment of total knee arthroplasty (TKA) has been correlated with patellofemoral maltracking, knee instability, and stiffness. CT is the most accurate method to assess rotational alignment of prosthetic components after TKA, but inter- and intraobserver reliability of CT scans for this use has not been well documented. QUESTIONS/PURPOSES: The objective of this study was to determine the inter- and intraobserver reliability and the repeatability of the measurement of TKA component rotation using two-dimensional CT scans. METHODS: Fifty-two CT scans of TKAs being evaluated for revision surgery were measured by three different physicians. An orthopaedic resident and attending measured the same scans twice (more than 2 weeks apart) and a musculoskeletal radiologist measured them once. To assess interobserver reliability, intraclass correlation coefficients (ICCs) with two-way mixed-effects analysis of variance models as well as 95% confidence intervals for each were done. The repeatability coefficient was calculated as well, which is defined as the difference in measurements that include 95% of the values. This indicates the magnitude of variability among measurements in the same scale, which in this study is degrees. RESULTS: The interobserver ICC measurement for the femoral component was 0.386 (poor), and it was 0.670 (good) for the tibial component. The interobserver ICC for the combined rotation measurements was 0.617 (good). The intraobserver ICC for the femoral component was 0.606 (good), and it was 0.809 (very good) for the tibial component. The intraobserver ICC for combined rotation was 0.751 (good). The intraobserver repeatability coefficient for the femoral component was 0.49°, 10.64° for the tibial component, and 12.29° for combined rotation. CONCLUSIONS: In this study, the inter- and intraobserver reliability, and the repeatability, of TKA component rotation were variable. This raises concern about whether CT scan is diagnostic in the assessment of component malrotation after TKA.


Assuntos
Artroplastia do Joelho , Instabilidade Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiografia , Reoperação , Reprodutibilidade dos Testes , Rotação , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
14.
J Clin Invest ; 134(8)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38421730

RESUMO

Staphylococcus aureus is a leading cause of biofilm-associated prosthetic joint infection (PJI). A primary contributor to infection chronicity is an expansion of granulocytic myeloid-derived suppressor cells (G-MDSCs), which are critical for orchestrating the antiinflammatory biofilm milieu. Single-cell sequencing and bioinformatic metabolic algorithms were used to explore the link between G-MDSC metabolism and S. aureus PJI outcome. Glycolysis and the hypoxia response through HIF1a were significantly enriched in G-MDSCs. Interfering with both pathways in vivo, using a 2-deoxyglucose nanopreparation and granulocyte-targeted Hif1a conditional KO mice, respectively, attenuated G-MDSC-mediated immunosuppression and reduced bacterial burden in a mouse model of S. aureus PJI. In addition, single-cell RNA-Seq (scRNA-Seq) analysis of granulocytes from PJI patients also showed an enrichment in glycolysis and hypoxia-response genes. These findings support the importance of a glycolysis/HIF1a axis in promoting G-MDSC antiinflammatory activity and biofilm persistence during PJI.


Assuntos
Células Supressoras Mieloides , Humanos , Camundongos , Animais , Células Supressoras Mieloides/fisiologia , Staphylococcus aureus , Biofilmes , Granulócitos , Hipóxia
15.
Clin Orthop Relat Res ; 471(1): 155-61, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22972652

RESUMO

BACKGROUND: Computer-aided surgery aims to improve implant alignment in TKA but has only been adopted by a minority for routine use. A novel approach, navigated freehand bone cutting (NFC), is intended to achieve wider acceptance by eliminating the need for cumbersome, implant-specific mechanical jigs and avoiding the expense of navigation. QUESTIONS/PURPOSES: We determined cutting time, surface quality, implant fit, and implant alignment after NFC of synthetic femoral specimens and the feasibility and alignment of a complete TKA performed with NFC technology in cadaveric specimens. METHODS: Seven surgeons prepared six synthetic femoral specimens each, using our custom NFC system. Cutting times, quality of bone cuts, and implant fit and alignment were assessed quantitatively by CT surface scanning and computational measurements. Additionally, a single surgeon performed a complete TKA on two cadaveric specimens using the NFC system, with cutting time and implant alignment analyzed through plain radiographs and CT. RESULTS: For the synthetic specimens, femoral coronal alignment was within ± 2° of neutral in 94% of the specimens. Sagittal alignment was within 0° to 5° of flexion in all specimens. Rotation was within ± 1° of the epicondylar axis in 97% of the specimens. The mean time to make cuts improved from 13 minutes for the first specimen to 9 minutes for the fourth specimen. TKA was performed in two cadaveric specimens without complications and implants were well aligned. CONCLUSIONS: TKA is feasible with NFC, which eliminates the need for implant-specific instruments. We observed a fast learning curve. CLINICAL RELEVANCE: NFC has the potential to improve TKA alignment, reduce operative time, and reduce the number of instruments in surgery. Fewer instruments and less sterilization could reduce costs associated with TKA.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador/instrumentação , Artroplastia do Joelho/métodos , Humanos , Duração da Cirurgia , Projetos Piloto , Amplitude de Movimento Articular , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
16.
Arthroplast Today ; 19: 101005, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36483330

RESUMO

Left ventricular assist devices (LVADs) may be used as bridge therapy or destination therapy in heart failure patients. Total joint arthroplasty may improve the functional status of patients limited by arthritis. This retrospective case series evaluated patients with an implanted LVAD who underwent a total joint arthroplasty at 1 institution from 2012 to present. Five patients underwent 12 surgeries with 7 primary arthroplasties and 5 revisions. Their mortality, length of stay, coagulopathic events, incidence of infection or revision arthroplasty, and heart transplantation were evaluated, and is the largest study to date of this population. Two patients expired from thrombotic events while 3 progressed to heart transplantation. Joint arthroplasty is feasible in patients with an implanted LVAD with expected risk and perioperative multidisciplinary collaboration.

17.
J Bone Joint Surg Am ; 2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37053296

RESUMO

➤: An increase in resistant bacterial pathogens has occurred over the last 4 decades. ➤: Careful patient selection and improving or correcting risk factors for periprosthetic joint infection (PJI) before elective surgical treatment are strongly recommended. ➤: Appropriate microbiological methods, including those used to detect and grow Cutibacterium acnes, are recommended. ➤: Antimicrobial agents used in the prevention or management of infection should be selected appropriately and the duration of therapy should be carefully considered in order to mitigate the risk of developing bacterial resistance. ➤: Molecular methods including rapid polymerase chain reaction (PCR) diagnostics, 16S sequencing, and/or shotgun and/or targeted whole-genome sequencing are recommended in culture-negative cases of PJI. ➤: Expert consultation with an infectious diseases specialist (if available) is recommended to assist with the appropriate antimicrobial management and monitoring of patients with PJI.

18.
Instr Course Lect ; 61: 313-25, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22301243

RESUMO

Management of the femur during revision total hip arthroplasty can be challenging. Strategies for femoral reconstruction are based on understanding the degree of femoral bone loss. Numerous options exist for femoral reconstruction depending on the quantity and quality of the remaining femoral bone stock, including cemented fixation, cementless fixation using proximally porous-coated implants, cylindrical extensively porous-coated implants, modular and nonmodular tapered fluted stems, impaction bone grafting, allograft-prosthetic composites, and proximal femoral replacements (megaprostheses). An understanding of the results of various methods of femoral reconstruction is helpful in guiding the revision surgeon faced with a challenging femoral revision.


Assuntos
Artroplastia de Quadril , Fêmur/cirurgia , Artroplastia de Quadril/métodos , Transplante Ósseo , Cimentação , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Humanos , Cuidados Pré-Operatórios , Desenho de Prótese , Radiografia , Procedimentos de Cirurgia Plástica , Reoperação
19.
Artigo em Inglês | MEDLINE | ID: mdl-35696313

RESUMO

Patients who participate in recreational injection drug use (RIVDU) have an increased risk of orthopaedic infections requiring prolonged treatment with intravenous antibiotics. This study reviews clinical outcomes and complications in RIVDU and have orthopaedic infections requiring long term antibiotic therapy (>4 weeks) and compares these outcomes to non-RIVDU patients. In this retrospective review, patients were divided into cohorts based on RIVDU history; the RIVDU cohort was further divided into subcohorts based on treatment location. Cohorts and subcohorts were compared to evaluate clinical outcomes. Between the two main cohorts, there was a statistically significant difference in treatment compliance (P = 0.0012) and no statistically significant differences for infection resolution at 6- or 12-month follow-up, hospital readmission, or mortality. At the 6-month follow-up, RIVDU patients who remained inpatient had 100% resolution of infection, which was significantly better than the resolution of all other cohorts (P = 0.0019). No differences were observed between the remaining subcohorts for resolution of infection by 12 months, catheter complications, or loss to follow-up. Our findings demonstrate an increased rate of failure in outpatient parenteral antibiotic therapy in RIVDU patients, and this population has better clinical outcomes when they remain inpatient for the duration of treatment.


Assuntos
Antibacterianos , Usuários de Drogas , Procedimentos Ortopédicos , Infecção da Ferida Cirúrgica , Administração Intravenosa , Antibacterianos/administração & dosagem , Humanos , Procedimentos Ortopédicos/efeitos adversos , Abuso de Substâncias por Via Intravenosa/complicações , Infecção da Ferida Cirúrgica/tratamento farmacológico , Resultado do Tratamento
20.
Bone Joint J ; 103-B(6 Supple A): 165-170, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34053295

RESUMO

AIMS: Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. METHODS: This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher's exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. RESULTS: No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). CONCLUSION: There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165-170.


Assuntos
Artroplastia do Joelho/métodos , Cimentação/efeitos adversos , Prótese do Joelho , Dor Pós-Operatória/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Reoperação , Estudos Retrospectivos , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA