Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39031021

RESUMO

AIMS: Ventricular tachycardia (VT) non-inducibility in response to programmed ventricular stimulation (PVS) is a widely used procedural endpoint for VT ablation despite inconclusive evidence with respect to clinical outcomes in high-risk patients. The aim is to determine the utility of acute post-ablation VT inducibility as a predictor of VT recurrence, mortality, or mortality equivalent in high-risk patients. METHODS AND RESULTS: We conducted a retrospective analysis of high-risk patients (defined as PAINESD > 17) who underwent scar-related VT ablation at our institution between July 2010 and July 2022. Patients' response to PVS (post-procedure) was categorized into three groups: Group A, no clinical VT or VT with cycle length > 240 ms inducible; Group B, only non-clinical VT with cycle length > 240 ms induced; and Group C, all other outcomes (including cases where no PVS was performed). The combined primary endpoint included death, durable left ventricular assist device placement, and cardiac transplant (Cox analysis). Ventricular tachycardia recurrence was considered a secondary endpoint (competing risk analysis). Of the 1677 VT ablation cases, 123 cases met the inclusion criteria for analysis. During a 19-month median follow-up time (interquartile range 4-43 months), 82 (66.7%) patients experienced the composite primary endpoint. There was no difference between Groups A and C with respect to the primary [hazard ratio (HR) = 1.21 (0.94-1.57), P = 0.145] or secondary [HR = 1.18 (0.91-1.54), P = 0.210] outcomes. These findings persisted after multivariate adjustments. The size of Group B (n = 13) did not permit meaningful statistical analysis. CONCLUSION: The results of post-ablation PVS do not significantly correlate with long-term outcomes in high-risk (PAINESD > 17) VT ablation patients.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Cicatriz/fisiopatologia , Cicatriz/etiologia , Idoso , Medição de Risco , Resultado do Tratamento , Fatores de Risco
2.
Molecules ; 28(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37513199

RESUMO

The aim of the present study was to develop an injectable hydrogel (HG) formulation of fuzapladib sodium (FZP), an animal drug for acute pancreatitis (AP), with the use of polyethyleneoxide (PEO) and polylysine (pLys), a cationic polymer. A mixture of pLys and FZP was added to PEO to prepare an HG formulation, and the formulation was optimized by release test and viscosity measurements. Circular dichroism (CD) and infrared absorption (IR) spectral analyses were applied to clarify the intermolecular interactions between FZP and pLys. The pharmacokinetic behavior of FZP was evaluated after a subcutaneous administration of FZP samples (2.0 mg-FZP/kg) to rats. Although the immediate release of FZP was observed for the HG formulation, the addition of pLys at a 20-fold amount of FZP or higher led to the sustained release of FZP. Considering release behavior, the concentration of pLys was optimized as 100-fold that of FZP in the HG formulation. CD and IR spectroscopic analyses of FZP and/or pLys demonstrated an intermolecular interaction between FZP and pLys, as evidenced by the slight spectral transition. After a subcutaneous administration of HG formulation containing pLys to rats, compared with FZP alone, significant differences were observed in the pharmacokinetic behavior with a decrease of Cmax from 2.3 to 0.9 mg/mL and slower elimination kinetics. HG formulation using pLys might be a viable dosage option for FZP for the treatment of AP in animals.


Assuntos
Pancreatite , Polilisina , Ratos , Animais , Polilisina/química , Hidrogéis , Preparações de Ação Retardada/química , Antígeno-1 Associado à Função Linfocitária , Doença Aguda , Leucócitos
3.
J Cardiovasc Electrophysiol ; 33(6): 1177-1182, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35348267

RESUMO

INTRODUCTION: The surface electrocardiography of typical atrioventricular nodal reentrant tachycardia (AVNRT) shows simultaneous ventricular-atrial (RP) activation with pseudo R' in V1 and typical heart rates ranging from 150 to 220/min. Slower rates are suspicious for junctional tachycardia (JT). However, occasionally we encounter typical AVNRT with slow ventricular rates. We describe a series of typical AVNRT cases with heart rates under 110/min. METHODS: A total of 1972 patients with AVNRT who underwent slow pathway ablation were analyzed. Typical AVNRT was diagnosed when; (1) evidence of dual atrioventricular nodal conduction, (2) tachycardia initiation by atrial drive train with atrial-His-atrial response, (3) short septal ventriculoatrial time, and (4) ventricular-atrial-ventricular (V-A-V) response to ventricular overdrive (VOD) pacing with corrected post pacing interval-tachycardia cycle length (cPPI-TCL) > 110 ms. JT was excluded by either termination or advancement of tachycardia by atrial extrastimuli (AES) or atrial overdrive (AOD) pacing. RESULTS: We found 11 patients (age 20-78 years old, six female) who met the above-mentioned criteria. The TCL ranged from 560 to 782 ms. Except for one patient showing tachycardia termination, all patients demonstrated a V-A-V response and cPPI-TCL over 110 ms with VOD. AES or AOD pacing successfully excluded JT by either advancing the tachycardia in 10 patients or by tachycardia termination in one patient. Slow pathway was successfully ablated, and tachycardia was not inducible in all patients. CONCLUSIONS: This case series describes patients with typical AVNRT with slow ventricular rate (less than 110/min) who may mimic JT. We emphasize the importance of using pacing maneuvers to exclude JT.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular , Adulto , Idoso , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto Jovem
4.
J Cardiovasc Electrophysiol ; 33(1): 73-80, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34822200

RESUMO

INTRODUCTION: Direction-aware mapping algorithms improve the accuracy of voltage mapping by measuring the maximal voltage amplitude recorded in the direction of wavefront propagation. While beneficial for stationary catheters, its utility for roving catheters collecting electrograms (EGMs) at multiple angles is unknown. OBJECTIVE: To compare the directional dependence of bipolar voltage amplitude between stationary and roving catheters. METHODS: In 10 swine, a transcaval ablation line with a gap was created. The gap was mapped using an array catheter (Optrell™; Biosense Webster). In Step 1, the array was kept stationary over the gap, and four voltage maps were created during activation of the gap from superior, inferior, septal, and lateral directions. In Step 2, four additional maps were created; however, the catheter was allowed to move with points acquired at multiple angles. In Step 3, the gap was remapped; however, bipoles were computed using a direction-aware mapping algorithm. RESULTS: In a stationary catheter position, bipolar voltage distribution was influenced by the direction of activation with maximal differences obtained between orthogonal directions 32% (13%-53%). However, roving the catheter produced similar bipolar voltage maps irrespective of the direction of activation 11% (5%-18%). A direction-aware mapping algorithm was beneficial for reducing the directional dependence of voltage maps created by stationary catheters but not by roving catheters. CONCLUSION: The directional dependency of bipolar voltage amplitude is greatest when the catheter is stationary. However, when the catheter is allowed to rove and collect EGMs at multiple angles as occurs clinically, the directional dependence of bipolar voltage is minimal.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Algoritmos , Animais , Fibrilação Atrial/cirurgia , Catéteres , Técnicas Eletrofisiológicas Cardíacas , Suínos
5.
Biopharm Drug Dispos ; 43(3): 89-97, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35322875

RESUMO

This study aimed to develop an oral nanocrystal solid dispersion (nCSD) of fuzapladib (FZP) with enhanced absorbability for the treatment of acute pancreatitis (AP). The hydration properties of crystalline FZP free acid (crystalline FZP) and FZP sodium salt (FZP/Na) were assessed to select a stable crystal form. The nCSD of FZP free acid (nCSD/FZP) was prepared using a multi-inlet vortex mixer and evaluated in terms of physicochemical and pharmacokinetic properties. The results of X-ray powder diffraction analysis indicated that crystalline FZP was stable as an anhydrate, while FZP/Na was converted to its monohydrate at water activity of above 0.2. The nanocrystals in nCSD/FZP were dispersed in hydroxy propyl cellulose-SSL, and their mean particle size were 160 nm with uniform spherical shape. In dissolution testing, nCSD/FZP exhibited rapid dissolution compared with crystalline FZP and reached a saturated concentration of FZP within initial 30 min. After oral administration (2 mg-FZP/kg) to rats, the maximum plasma concentration and bioavailability were 7.3- and 5.2-fold higher for nCSD/FZP than crystalline FZP, respectively, due to improved dissolution by nanosization. In conclusion, nCSD/FZP may be a novel oral dosage form with enhanced absorbability facilitating potent therapeutic effects of FZP for the treatment of AP in animals.


Assuntos
Nanopartículas , Pancreatite , Doença Aguda , Administração Oral , Animais , Disponibilidade Biológica , Química Farmacêutica/métodos , Nanopartículas/química , Tamanho da Partícula , Ratos , Solubilidade
6.
Pharm Dev Technol ; 27(5): 565-571, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35694736

RESUMO

The aim of the present study was to develop and evaluate stabilized injection solutions of fuzapladib sodium hydrate using antioxidants as the stabilizers. To estimate the possible degradation factors and pathways of fuzapladib, forced degradation studies were conducted under thermal, acid, base, oxidative, and light conditions. To select an optimal excipient to stabilize fuzapladib under a solution state, a screening study of antioxidants was carried out to evaluate their effects to inhibit the degradation. The influence of the selected stabilizers on its pharmacokinetic behavior was evaluated in rats after intravenous administration. On the basis of data from the forced degradation study, thermal and oxidative stresses were significant factors accelerating the degradation of fuzapladib. Among eight tested antioxidants, vitamin C (VC) was the most effective stabilizer to suppress the accelerated degradation by heating, as evidenced by 45% inhibition of the degradation. The stabilization effect was enhanced depending on the concentration of VC. After the intravenous administration of fuzapladib (0.5 mg/kg) with or without VC (2.1 mg/kg), there were no significant differences between the pharmacokinetic behaviors of each group. From these findings, VC might be a promising excipient to stabilize the injection solution of fuzapladib without significant influence on its pharmacokinetic behavior.


Assuntos
Ácido Ascórbico , Excipientes , Animais , Antioxidantes/farmacocinética , Oxirredução , Estresse Oxidativo , Ratos
7.
J Cardiovasc Electrophysiol ; 32(7): 1909-1917, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955116

RESUMO

BACKGROUND: Activation maps of scar-related atrial tachycardias (AT) can be challenging to interpret due to difficulty in inaccurate annotation of electrograms, and an arbitrarily predefined mapping window. A novel mapping software integrating vector data and applying an algorithmic solution taking into consideration global activation pattern has been recently described (Coherent™, Biosense Webster "Investigational"). OBJECTIVE: We aimed to assess the investigational algorithm to determine the mechanism of AT compared with the standard algorithm. METHODS: This study included patients who underwent ablation of scar-related AT using the Carto 3 and the standard activation algorithm. The mapping data were analyzed retrospectively using the investigational algorithm, and the mechanisms were evaluated by two independent electrophysiologists. RESULTS: A total of 77 scar-related AT activation maps were analyzed (89.6% left atrium, median tachycardia cycle length of 273 ms). Of those, 67 cases with a confirmed mechanism of arrhythmia were used to compare the activation software. The actual mechanism of the arrhythmia was more likely to be identified with the investigational algorithm (67.2% vs. 44.8%, p = .009). In five patients with dual-loop circuits, 3/5 (60%) were correctly identified by the investigational algorithm compared to 0/5 (0%) with the standard software. The reduced atrial voltage was prone to lead to less capable identification of mechanism (p for trend: .05). The investigational algorithm showed higher inter-reviewer agreement (Cohen's kappa .62 vs. .47). CONCLUSIONS: In patients with scar-related ATs, activation mapping algorithms integrating vector data and "best-fit" propagation solution may help in identifying the mechanism and the successful site of termination.


Assuntos
Ablação por Cateter , Cicatriz , Algoritmos , Cicatriz/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia
8.
Int Heart J ; 62(4): 771-778, 2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34276012

RESUMO

Radiofrequency catheter ablation (RFCA) for pulmonary artery ventricular arrhythmia (PAVA) can be difficult because of the occasional existence of PAVA with preferential conduction.This study described the characteristics of PAVA that demonstrate preferential conduction.We analyzed electrocardiographic and electrophysiological data from 8 patients found to have PAVAs with preferential conduction out of 183 patients (4.4%) with right ventricular outflow tract (RVOT) arrhythmias who underwent RFCA at our hospitals. The PAVA with preferential conduction were classified into two types. In type 1 PAVA, successful ablation sites (success-sites) exhibited discrete prepotentials with an isoelectric line, in which the activation time (AT) was ≥ 50 milliseconds. In type 2 PAVA, excellent pace mapping was achieved at two sites separated by ≥ 20 mm: one in the RVOT free wall and the other at the success-site in the pulmonary artery. Type 1 and 2 PAVA features were considered signs of a short and long preferential conduction pathway, respectively.There were four patients each with type 1 and 2 PAVA. Type 1 PAVA was distinguished by the isoelectric line at success-sites with the mean AT of 78 ± 25.1 milliseconds. In type 2 PAVAs, although the AT at RVOT sites was very short (18.5 ± 10.1 milliseconds), the AT at success-sites was longer than that at the RVOT by 42.3 ± 36.2 milliseconds. Type 2 PAVAs displayed distinct electrocardiogram (ECG) features (R wave in lead I, RR' in inferior leads, and transitional zone in V4) not found in typical PAVA ECGs.PAVA with preferential conduction can manifest in distinct ways on the ECG and intracardiac mapping. Knowledge of these features may facilitate successful RFCA of such PAVA cases.


Assuntos
Arritmias Cardíacas/fisiopatologia , Ablação por Cateter , Eletrocardiografia , Artéria Pulmonar/fisiopatologia , Adolescente , Adulto , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
J Cardiovasc Electrophysiol ; 29(4): 514-522, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29369468

RESUMO

INTRODUCTION: Dominant frequency (DF) derived from fast Fourier transform (FFT) analysis has failed to guide atrial fibrillation (AF) ablation since it cannot guarantee temporal stability. Continuous wavelet transform (CWT) analysis is another frequency analysis that can show the temporal stability of a frequency. METHODS AND RESULTS: Forty-four consecutive patients with persistent AF (PeAF) underwent pulmonary vein (PV) isolation (PVI) as the first-time catheter ablation. The PVs and left atrium were mapped and electrograms (EGMs) were recorded for 30 seconds at each site. Pseudo-frequency (PF) and coefficient of variation (CV) were calculated by CWT analysis. A PF with CV ≤ 10 was defined as a temporally stable PF (sPF). DF was also calculated by traditional FFT analysis from the first 5 seconds of the recorded EGMs. The highest sPF was shown inside the PVs in 20 patients (PV group), and at the non-PV sites in 24 patients (non-PV group). During the follow-up period of 15.3 ± 4.4 months, the ablation success rate in the PV group was significantly higher than that in the non-PV group (90% vs. 62%, P = 0.023). The location of the highest DF did not have a significant effect on ablation success rate between inside the PVs and at the non-PV sites. CONCLUSION: PVI results for PeAF were significantly worse for patients with highest sPF at the non-PV sites compared to patients with highest sPF sites inside the PVs. CWT analysis during AF could be used to verify whether PVI alone is sufficient for the first-time catheter ablation in patients with PeAF.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Frequência Cardíaca , Veias Pulmonares/cirurgia , Análise de Ondaletas , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 39(4): 352-60, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26769094

RESUMO

BACKGROUND: Superior vena cava (SVC) can be a focus of atrial fibrillation (AF). However, distinctive features that identify SVC arrhythmogenicity remain unclear. Sustainability of fibrillation within the SVC might help with identifying SVC arrhythmogenicity. The purpose of this study was to investigate the relationship between the anatomical and electrical profiles of SVC and sustainability of SVC fibrillation induced by proactive electrical stimulation. METHODS: Consecutive 36 patients with paroxysmal or persistent AF who underwent repetitive pulmonary vein isolation (PVI) session were included in the study. After successful PVI, periodic rapid electrical stimuli were delivered to the SVC to induce SVC fibrillation. SVC fibrillation was defined as follows: (1) the local fibrillatory electrical activity persisted longer than 3 seconds, (2) the local fibrillatory activity penetrated through the atrium and maintained AF, and (3) the frequency of local activity was higher than that of any other atrial components such as coronary sinus and right atrial appendage. RESULTS: SVC fibrillation was induced in seven patients. The group with SVC fibrillation had significantly longer SVC sleeve and longer left atrial diameter compared with the group without SVC fibrillation. All patients with SVC fibrillation were free from AF recurrence after SVC isolation. CONCLUSIONS: The SVC sleeve longer than 30 mm had sustainability of SVC fibrillation induced by electrical stimulation. This finding advocates that arrhythmogenic substrate may exist in the SVC with long myocardial sleeve.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Estimulação Elétrica/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veia Cava Superior/fisiopatologia , Adulto , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Cardiovasc Electrophysiol ; 25(7): 774-80, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24762029

RESUMO

BACKGROUND: Voltage mapping is an important tool for characterizing proarrhythmic electrophysiological substrate, yet it is subject to geometric factors that influence bipolar amplitudes and thus compromise performance. The aim of this study was to characterize the impact of catheter orientation on the ability of bipolar amplitudes to accurately discriminate between healthy and diseased tissues. METHODS AND RESULTS: We constructed a 3-dimensional, in silico, bidomain model of cardiac tissue containing transmural lesions of varying diameter. A planar excitation wave was stimulated and electrograms were sampled with a realistic catheter model at multiple positions and orientations. We carried out validation studies in animal experiments of acute ablation lesions mapped with a clinical mapping system. Bipolar electrograms sampled at higher inclination angles of the catheter with respect to the tissue demonstrated improvements in both sensitivity and specificity of lesion detection. Removing low-voltage electrograms with concurrent activation of both electrodes, suggesting false attenuation of the bipolar electrogram due to alignment with the excitation wavefront, had little effect on the accuracy of voltage mapping. CONCLUSIONS: Our results demonstrate possible mechanisms for the impact of catheter orientation on voltage mapping accuracy. Moreover, results from our simulations suggest that mapping accuracy may be improved by selectively controlling the inclination of the catheter to record at higher angles with respect to the tissue.


Assuntos
Arritmias Cardíacas/diagnóstico , Cateterismo Cardíaco , Simulação por Computador , Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Potenciais de Ação , Animais , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Humanos , Cinética , Modelos Animais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Suínos
14.
Turk Kardiyol Dern Ars ; 42(1): 11-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24481089

RESUMO

OBJECTIVES: The extent of left atrial (LA) wall structural remodeling (fibrosis) detected by late gadolinium enhancement-magnetic resonance imaging (LGE-MRI) is correlated with advanced atrial fibrillation (AF). The concomitant occurrence of AF and left ventricular (LV) dysfunction is not uncommon. We studied the effect of LA fibrosis, a confounder of both AF and LV dysfunction, on LV ejection fraction (EF). STUDY DESIGN: For the analysis, we identified and included 384 patients from our retrospective AF database who underwent LGE-MRI and transthoracic echocardiography prior to AF ablation. Based on the degree of LA fibrosis, patients were categorized into four stages as: Utah 1 (<5% LA fibrosis), Utah 2 (5-20% fibrosis), Utah 3 (20-35% fibrosis), and Utah 4 (>35% fibrosis). RESULTS: The average pre-ablation LVEF was 60.5%±8.5% (n=24) in Utah stage 1 patients, 55.7%±10.3% (n=240) in Utah stage 2 patients, 51.7±11.5% (n=90) in Utah stage 3 patients, and 48.9%±11.6% (n=30) in Utah stage 4 patients (p<0.001, one-way ANOVA). The percentage of LA fibrosis was significantly negatively correlated to LVEF pre-ablation in a univariate analysis (p<0.001). In a multivariate model accounting for age, gender, AF type, and comorbidities such as diabetes and hypertension, Utah stage remained a significant predictor of pre-ablation EF (p<0.001). CONCLUSION: Patients with extensive LA fibrosis appear to have depressed LV function pre-ablation, suggesting that structural remodeling in the LA may also be triggering and promoting remodeling within the ventricular myocardium.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial/fisiologia , Volume Sistólico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo/fisiologia , Feminino , Septos Cardíacos/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
JACC Clin Electrophysiol ; 10(5): 981-999, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38385913

RESUMO

In patients with structural heart disease and ventricular tachycardia (VT) undergoing catheter ablation, the response to programmed electrical stimulation (PES) at the end of the procedure has been traditionally used to evaluate the acute success and predict long-term outcomes. Although noninducibility at PES has been extensively investigated and validated in clinical trials and large multicenter registries, its performance in predicting long-term freedom from VT is suboptimal. In addition, PES has inherent limitations related to the influence of background antiarrhythmic drug therapy, periprocedural use of anesthesia, and the heterogeneity in PES protocols. The increased utilization of substrate-based ablation approaches that focus on ablation of abnormal electrograms identified with mapping in sinus or paced rhythm has been paralleled by a need for additional procedural endpoints beyond VT noninducibility at PES. This article critically appraises the relative merits and limitations of different procedural endpoints according to different ablation techniques for catheter ablation of scar-related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Humanos , Ablação por Cateter/métodos , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas/métodos , Estimulação Elétrica/métodos
16.
Front Microbiol ; 15: 1404991, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38887715

RESUMO

Ruminal methane production is the main sink for metabolic hydrogen generated during rumen fermentation, and is a major contributor to greenhouse gas (GHG) emission. Individual ruminants exhibit varying methane production efficiency; therefore, understanding the microbial characteristics of low-methane-emitting animals could offer opportunities for mitigating enteric methane. Here, we investigated the association between rumen fermentation and rumen microbiota, focusing on methane production, and elucidated the physiological characteristics of bacteria found in low methane-producing cows. Thirteen Holstein cows in the late lactation stage were fed a corn silage-based total mixed ration (TMR), and feed digestion, milk production, rumen fermentation products, methane production, and rumen microbial composition were examined. Cows were classified into two ruminal fermentation groups using Principal component analysis: low and high methane-producing cows (36.9 vs. 43.2 L/DMI digested) with different ruminal short chain fatty acid ratio [(C2+C4)/C3] (3.54 vs. 5.03) and dry matter (DM) digestibility (67.7% vs. 65.3%). However, there were no significant differences in dry matter intake (DMI) and milk production between both groups. Additionally, there were differences in the abundance of OTUs assigned to uncultured Prevotella sp., Succinivibrio, and other 12 bacterial phylotypes between both groups. Specifically, a previously uncultured novel Prevotella sp. with lactate-producing phenotype was detected, with higher abundance in low methane-producing cows. These findings provide evidence that Prevotella may be associated with low methane and high propionate production. However, further research is required to improve the understanding of microbial relationships and metabolic processes involved in the mitigation of enteric methane.

17.
Am J Physiol Heart Circ Physiol ; 305(5): H725-31, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23812387

RESUMO

Structural remodeling in chronic atrial fibrillation (AF) occurs over weeks to months. To study the electrophysiological, structural, and functional changes that occur in chronic AF, the selection of the best animal model is critical. AF was induced by rapid atrial pacing (50-Hz stimulation every other second) in pigs (n = 4), dogs (n = 8), and goats (n = 9). Animals underwent MRIs at baseline and 6 mo to evaluate left ventricular (LV) ejection fraction (EF). Dogs were given metoprolol (50-100 mg po bid) and digoxin (0.0625-0.125 mg po bid) to limit the ventricular response rate to <180 beats/min and to mitigate the effects of heart failure. The pacing leads in pigs became entirely encapsulated and lost the ability to excite the heart, often before the onset of sustained AF. LV EF in dogs dropped from 54 ± 11% at baseline to 33 ± 7% at 6 mo (P < 0.05), whereas LV EF in goats did not drop significantly (69 ± 8% at baseline vs. 60 ± 9% at 6 mo, P = not significant). After 6 mo of AF, fibrosis levels in dog atria and ventricles increased, whereas only atrial fibrosis levels increased in goats compared with control animals. In our experience, the pig model is not appropriate for chronic rapid atrial pacing-induced AF studies. Rate-controlled chronic AF in the dog model developed HF and LV fibrosis, whereas the goat model developed only atrial fibrosis without ventricular dysfunction and fibrosis. Both the dog and goat models are representative of segments of the patient population with chronic AF.


Assuntos
Fibrilação Atrial/complicações , Cães/fisiologia , Cabras/fisiologia , Suínos/fisiologia , Disfunção Ventricular Esquerda/etiologia , Animais , Fibrilação Atrial/fisiopatologia , Doença Crônica , Modelos Animais de Doenças , Estimulação Elétrica , Frequência Cardíaca/fisiologia , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular/fisiologia
18.
J Cardiovasc Electrophysiol ; 24(5): 485-91, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23373748

RESUMO

BACKGROUND: Catheter ablation significantly improves the left ventricular (LV) function in patients with atrial fibrillation (AF) and LV systolic dysfunction. In this study, we compared the degree of left atrial structural remodeling (LA-SRM) in patients with normal versus reduced LV ejection fraction (LVEF). We also studied the impact of LA-SRM on LVEF improvement in patients undergoing ablation of AF. METHOD AND RESULTS: We categorized 384 patients into 2 groups based on their cardiac function: reduced LVEF group (LVEF ≤50%; n = 105) and normal LVEF group (LVEF > 50%; n = 279). LVEF was determined prior and mean 8 ± 3 months after catheter ablation for AF. Percentage of LA-SRM was quantified using LGE-MRI and patients were classified into 4 groups based on the amount of structural remodeling in their LA wall: minimal ≤ 5%, mild = 5-20%, moderate = 20-35%, and extensive ≥ 35%. The average preablation LA-SRM (21.5 ± 13.2% vs 15.4 ± 10.0%; P < 0.001) was significantly higher in reduced LVEF group than normal LVEF group. Among the 105 patients with reduced LVEF, while there was a modest 11.7 ± 8.4% average increase in LVEF following ablation, the greatest increase was seen in patients with less extensive LA-SRM (minimal = 19.3 ± 5.1%, n = 3, P = 0.02 and mild = 16.6 ± 9.9%, n = 48, P < 0.001). Patients with moderate and extensive fibrosis had an average EF improvement of 8.7 ± 11.1% and 2.8 ± 6.4%, respectively (n = 39, P < 0.001 and n = 15, P = 0.11, respectively). CONCLUSION: Patients with LV systolic dysfunction displayed a comparatively greater LA-SRM than patients with normal LVEF. Patients with lesser LA-SRM experienced a greater improvement in LVEF after catheter ablation for AF.


Assuntos
Fibrilação Atrial/patologia , Ablação por Cateter , Átrios do Coração/patologia , Disfunção Ventricular Esquerda/patologia , Idoso , Ecocardiografia , Feminino , Fibrose , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Curr Opin Cardiol ; 28(1): 2-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23128496

RESUMO

PURPOSE OF REVIEW: Superior vena cava (SVC) is one of the most important nonpulmonary vein origins of atrial fibrillation, and SVC should be carefully treated in order to decrease the recurrence of atrial fibrillation after ablation. Despite the fact that pulmonary vein isolation (PVI) should be performed prophylactically for all pulmonary veins, prophylactic SVC isolation (SVCI) is still controversial. This review describes recent data on treatments for SVC focus during atrial fibrillation ablation. RECENT FINDINGS: There are two different major approaches to treat SVC focus during atrial fibrillation ablation. One is the conventional approach, in which SVCI is performed only if atrial fibrillation from SVC origin is recognized using pacing maneuvers and/or isoproterenol infusions. Another approach is performing SVCI in all cases prophylactically in addition to PVI. The rate of atrial fibrillation freedom 1 year after initial atrial fibrillation ablation by prophylactic PVI along with SVCI was almost the same as with the conventional method (85-90% atrial fibrillation freedom). In addition, the conventional method also had a good result even 5 years after ablation (73.3%). SUMMARY: Because of the good result after using the conventional approach and possible complications during SVCI, SVCI should be performed only if SVC focus is recognized, not prophylactically.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos dos Nervos Periféricos , Complicações Pós-Operatórias , Veia Cava Superior , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Avaliação de Processos e Resultados em Cuidados de Saúde , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/fisiopatologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Prevenção Secundária , Resultado do Tratamento , Veia Cava Superior/fisiopatologia , Veia Cava Superior/cirurgia
20.
Europace ; 15(12): 1725-32, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23711578

RESUMO

AIMS: Therapeutic effectiveness of ablation of atrial fibrillation (AF) is related to cardiovascular comorbidities. We studied the relationship between left ventricular hypertrophy (LVH) and left atrial tissue structural remodelling (LA-SRM), in patients presenting for AF ablation. METHODS AND RESULTS: We identified 404 AF patients who received a late gadolinium enhancement magnetic resonance imaging (LGE-MRI) prior to catheter ablation. Left ventricular hypertrophy was defined as LV mass index >116 g/m(2) in men and >104 g/m(2) in women. One hundred and twenty-two patients were classified as the LVH group and 282 as the non-LVH group. We stratified patients into four stages based on their degree of LA-SRM (minimal, <5% fibrosis; mild, >5-20%; moderate, >20-35%; and extensive, >35%). All patients underwent catheter ablation with pulmonary vein isolation and posterior wall and septal debulking. The procedural outcome was monitored over a 1-year follow-up period. The mean LA-SRM was significantly higher in patients with LVH (19.4 ± 13.2%) than in non-LVH patients (15.3 ± 9.8%; P< 0.01). Patients with LVH generally had extensive LA-SRM (moderate and extensive stages; 38.5% of LVH group) as compared with non-LVH patients (23.1% of non-LVH group; P < 0.01). A Cox regression analysis showed that patients with LVH also had significantly higher AF recurrence rates than non-LVH patients (43.2 vs. 28%; P = 0.008) during the 1-year follow-up period post-ablation. CONCLUSION: Patients with LVH tend to have a significantly greater degree of LA-SRM, when compared with patients without LVH. Moreover, LA-SRM is a predictor for procedural success in patients undergoing AF ablation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Meios de Contraste , Hipertrofia Ventricular Esquerda/etiologia , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Fibrose , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/fisiopatologia , Estimativa de Kaplan-Meier , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA