Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Wound Repair Regen ; 24(1): 175-80, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26610062

RESUMO

Hypoxia at the surgical site impairs wound healing and oxidative killing of microbes. Surgical site infections are more common in obese patients. We hypothesized that subcutaneous oxygen tension (Psq O2) would decrease substantially in both obese and non-obese patients following induction of anesthesia and after surgical incision. We performed a prospective observational study that enrolled obese and non-obese surgical patients and measured serial Psq O2 before and during surgery. Seven morbidly obese and seven non-obese patients were enrolled. At baseline breathing room air, Psq O2 values were not significantly different (p = 0.66) between obese (6.8 kPa) and non-obese (6.5 kPa) patients. The targeted arterial oxygen tension (40 kPa) was successfully achieved in both groups with an expected significant increase in Psq O2 (obese 16.1 kPa and non-obese 13.4 kPa; p = 0.001). After induction of anesthesia and endotracheal intubation, Psq O2 did not change significantly in either cohort in comparison to levels right before induction (obese 15.5, non-obese 13.5 kPa; p = 0.95), but decreased significantly during surgery (obese 10.1, non-obese 9.3 kPa; p = 0.01). In both morbidly obese and non-obese patients, Psq O2 does not decrease appreciably following induction of anesthesia, but decreases markedly (∼33%) after commencement of surgery. Given the theoretical risks associated with low Psq O2 , future research should investigate how Psq O2 can be maintained after surgical incision.


Assuntos
Hipóxia/metabolismo , Obesidade Mórbida/metabolismo , Oxigênio/metabolismo , Pressão Parcial , Tela Subcutânea/metabolismo , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Tela Subcutânea/irrigação sanguínea , Ferida Cirúrgica , Cicatrização
2.
Anesthesiology ; 114(3): 557-64, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21307765

RESUMO

BACKGROUND: Vasopressors, such as norepinephrine, are frequently used to treat perioperative hypotension. Increasing perfusion pressure with norepinephrine may increase blood flow in regions at risk. However, the resulting vasoconstriction could deteriorate microcirculatory blood flow in the intestinal tract and kidneys. This animal study was designed to investigate the effects of treating perioperative hypotension with norepinephrine during laparotomy with low fluid volume replacement. METHODS: Twenty anesthetized and ventilated pigs were randomly assigned to a control or treatment (norepinephrine) group. Both groups received 3 ml · kg⁻¹ · h⁻¹ Ringer's lactate solution. In addition, the norepinephrine group received norepinephrine to stepwise increase blood pressure to 65 and 75 mmHg. Regional blood flow was measured in the splanchnic arteries. In the small bowel and colon, microcirculatory blood flow was measured using laser Doppler flowmetry. Intestinal tissue oxygen tension was measured with intramural Clark-type electrodes. RESULTS: Hepatosplanchnic and kidney blood flow remained unchanged after reversal of arterial hypotension to a mean arterial pressure of 75 mmHg with norepinephrine. For the norepinephrine group versus the control group, the mean ± SD microcirculatory blood flow in the jejunum (96 ± 41% vs. 93 ± 18%) and colon (98 ± 19% vs. 97 ± 28%) and intestinal tissue oxygen tension (jejunum, 45 ± 13 vs. 43 ± 5 mmHg; colon, 50 ± 10 vs. 45 ± 8 mmHg) were comparable. CONCLUSIONS: In this model of abdominal surgery in which clinical conditions were imitated as close as possible, treatment of perioperative hypotension with norepinephrine had no adverse effects on microcirculatory blood flow or tissue oxygen tension in the intestinal tract.


Assuntos
Abdome/cirurgia , Hipotensão/tratamento farmacológico , Hipotensão/etiologia , Intestinos/irrigação sanguínea , Complicações Intraoperatórias/tratamento farmacológico , Complicações Intraoperatórias/etiologia , Norepinefrina/uso terapêutico , Vasoconstritores/uso terapêutico , Animais , Débito Cardíaco/efeitos dos fármacos , Relação Dose-Resposta a Droga , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Hemoglobinas/metabolismo , Intestinos/efeitos dos fármacos , Laparotomia , Fluxometria por Laser-Doppler , Microcirculação/efeitos dos fármacos , Norepinefrina/administração & dosagem , Consumo de Oxigênio/fisiologia , Fluxo Sanguíneo Regional/efeitos dos fármacos , Mecânica Respiratória/efeitos dos fármacos , Mecânica Respiratória/fisiologia , Circulação Esplâncnica/efeitos dos fármacos , Suínos , Vasoconstritores/administração & dosagem
3.
J Surg Res ; 160(2): 288-93, 2010 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19482294

RESUMO

BACKGROUND: Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. MATERIALS AND METHODS: Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. RESULTS: After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. CONCLUSIONS: In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP.


Assuntos
Hemodinâmica/fisiologia , Hemorragia/fisiopatologia , Hipovolemia/fisiopatologia , Microcirculação/fisiologia , Oxigênio/metabolismo , Doença Aguda , Animais , Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Débito Cardíaco/fisiologia , Colo/irrigação sanguínea , Colo/metabolismo , Modelos Animais de Doenças , Parada Cardíaca/metabolismo , Parada Cardíaca/fisiopatologia , Hemorragia/metabolismo , Hipovolemia/metabolismo , Jejuno/irrigação sanguínea , Jejuno/metabolismo , Fluxometria por Laser-Doppler , Fígado/irrigação sanguínea , Fígado/metabolismo , Sus scrofa
4.
Anesthesiology ; 110(3): 496-504, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19225390

RESUMO

BACKGROUND: The aim of this study was to compare the effects of goal-directed colloid fluid therapy with goal-directed crystalloid and restricted crystalloid fluid therapy on healthy and perianastomotic colon tissue in a pig model of colon anastomosis surgery. METHODS: Pigs (n = 27, 9 per group) were anesthetized and mechanically ventilated. A hand-sewn colon anastomosis was performed. The animals were subsequently randomized to one of the following treatments: R-RL group, 3 ml x kg(-1) x h(-1) Ringer lactate (RL); GD-RL group, 3 ml x kg(-1) x h(-1) RL + bolus 250 ml of RL; GD-C group, 3 ml x kg(-1) x h(-1) RL + bolus 250 ml of hydroxyethyl starch (HES 6%, 130/0.4). A fluid bolus was administered when mixed venous oxygen saturation dropped below 60%. Intestinal tissue oxygen tension and microcirculatory blood flow were measured continuously. RESULTS: After 4 h of treatment, tissue oxygen tension in healthy colon increased to 150 +/- 31% in group GD-C versus 123 +/- 40% in group GD-RL versus 94 +/- 23% in group R-RL (percent of postoperative baseline values, mean +/- SD; P < 0.01). Similarly perianastomotic tissue oxygen tension increased to 245 +/- 93% in the GD-C group versus 147 +/- 58% in the GD-RL group and 116 +/- 22% in the R-RL group (P < 0.01). Microcirculatory flow was higher in group GD-C in healthy colon. CONCLUSIONS: Goal-directed colloid fluid therapy significantly increased microcirculatory blood flow and tissue oxygen tension in healthy and injured colon compared to goal-directed or restricted crystalloid fluid therapy.


Assuntos
Coloides/administração & dosagem , Colo/irrigação sanguínea , Colo/cirurgia , Objetivos , Microcirculação/efeitos dos fármacos , Anastomose Cirúrgica/métodos , Animais , Colo/efeitos dos fármacos , Hidratação/métodos , Microcirculação/fisiologia , Suínos
5.
Crit Care ; 13(2): R40, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19302713

RESUMO

INTRODUCTION: Perioperative hypovolemia arises frequently and contributes to intestinal hypoperfusion and subsequent postoperative complications. Goal-directed fluid therapy might reduce these complications. The aim of this study was to compare the effects of goal-directed administration of crystalloids and colloids on the distribution of systemic, hepatosplanchnic, and microcirculatory (small intestine) blood flow after major abdominal surgery in a clinically relevant pig model. METHODS: Twenty-seven pigs were anesthetized and mechanically ventilated and underwent open laparotomy. They were randomly assigned to one of three treatment groups: the restricted Ringer lactate (R-RL) group (n = 9) received 3 mL/kg per hour of RL, the goal-directed RL (GD-RL) group (n = 9) received 3 mL/kg per hour of RL and intermittent boluses of 250 mL of RL, and the goal-directed colloid (GD-C) group (n = 9) received 3 mL/kg per hour of RL and boluses of 250 mL of 6% hydroxyethyl starch (130/0.4). The latter two groups received a bolus infusion when mixed venous oxygen saturation was below 60% ('lockout' time of 30 minutes). Regional blood flow was measured in the superior mesenteric artery and the celiac trunk. In the small bowel, microcirculatory blood flow was measured using laser Doppler flowmetry. Intestinal tissue oxygen tension was measured with intramural Clark-type electrodes. RESULTS: After 4 hours of treatment, arterial blood pressure, cardiac output, mesenteric artery flow, and mixed oxygen saturation were significantly higher in the GD-C and GD-RL groups than in the R-RL group. Microcirculatory flow in the intestinal mucosa increased by 50% in the GD-C group but remained unchanged in the other two groups. Likewise, tissue oxygen tension in the intestine increased by 30% in the GD-C group but remained unchanged in the GD-RL group and decreased by 18% in the R-RL group. Mesenteric venous glucose concentrations were higher and lactate levels were lower in the GD-C group compared with the two crystalloid groups. CONCLUSIONS: Goal-directed colloid administration markedly increased microcirculatory blood flow in the small intestine and intestinal tissue oxygen tension after abdominal surgery. In contrast, goal-directed crystalloid and restricted crystalloid administrations had no such effects. Additionally, mesenteric venous glucose and lactate concentrations suggest that intestinal cellular substrate levels were higher in the colloid-treated than in the crystalloid-treated animals. These results support the notion that perioperative goal-directed therapy with colloids might be beneficial during major abdominal surgery.


Assuntos
Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Coloides/uso terapêutico , Hidratação/métodos , Hipovolemia/prevenção & controle , Cuidados Intraoperatórios , Complicações Intraoperatórias/prevenção & controle , Soluções Isotônicas/uso terapêutico , Abdome/cirurgia , Animais , Coloides/administração & dosagem , Soluções Cristaloides , Hidratação/normas , Hemodinâmica , Soluções Isotônicas/administração & dosagem , Fluxometria por Laser-Doppler , Modelos Animais , Monitorização Fisiológica , Suínos
6.
Crit Care ; 13(6): R186, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19930656

RESUMO

INTRODUCTION: Several recent studies have shown that a positive fluid balance in critical illness is associated with worse outcome. We tested the effects of moderate vs. high-volume resuscitation strategies on mortality, systemic and regional blood flows, mitochondrial respiration, and organ function in two experimental sepsis models. METHODS: 48 pigs were randomized to continuous endotoxin infusion, fecal peritonitis, and a control group (n = 16 each), and each group further to two different basal rates of volume supply for 24 hours [moderate-volume (10 ml/kg/h, Ringer's lactate, n = 8); high-volume (15 + 5 ml/kg/h, Ringer's lactate and hydroxyethyl starch (HES), n = 8)], both supplemented by additional volume boli, as guided by urinary output, filling pressures, and responses in stroke volume. Systemic and regional hemodynamics were measured and tissue specimens taken for mitochondrial function assessment and histological analysis. RESULTS: Mortality in high-volume groups was 87% (peritonitis), 75% (endotoxemia), and 13% (controls). In moderate-volume groups mortality was 50% (peritonitis), 13% (endotoxemia) and 0% (controls). Both septic groups became hyperdynamic. While neither sepsis nor volume resuscitation strategy was associated with altered hepatic or muscle mitochondrial complex I- and II-dependent respiration, non-survivors had lower hepatic complex II-dependent respiratory control ratios (2.6 +/- 0.7, vs. 3.3 +/- 0.9 in survivors; P = 0.01). Histology revealed moderate damage in all organs, colloid plaques in lung tissue of high-volume groups, and severe kidney damage in endotoxin high-volume animals. CONCLUSIONS: High-volume resuscitation including HES in experimental peritonitis and endotoxemia increased mortality despite better initial hemodynamic stability. This suggests that the strategy of early fluid management influences outcome in sepsis. The high mortality was not associated with reduced mitochondrial complex I- or II-dependent muscle and hepatic respiration.


Assuntos
Hidratação/métodos , Ressuscitação/métodos , Sepse/terapia , Animais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Débito Cardíaco , Modelos Animais de Doenças , Diurese , Frequência Cardíaca , Lactatos/sangue , Oxigênio/sangue , Peritonite/complicações , Peritonite/mortalidade , Peritonite/fisiopatologia , Artéria Pulmonar/fisiopatologia , Artéria Renal/fisiopatologia , Sepse/mortalidade , Volume Sistólico , Suínos
7.
Anesth Analg ; 108(6): 1823-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19448207

RESUMO

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. RESULTS: For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). CONCLUSIONS: Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.


Assuntos
Algoritmos , Automação , Pressão Sanguínea/fisiologia , Monitorização Intraoperatória/métodos , Abdome/cirurgia , Adulto , Idoso , Resistência das Vias Respiratórias/fisiologia , Volume Sanguíneo/fisiologia , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pulso Arterial , Padrões de Referência , Reprodutibilidade dos Testes , Mecânica Respiratória/fisiologia
8.
Obes Surg ; 18(1): 77-83, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18064525

RESUMO

BACKGROUND: Oxidative killing is the primary defense against surgical pathogens; risk of infection is inversely related to tissue oxygenation. Subcutaneous tissue oxygenation in obese patients is significantly less than in lean patients during general anesthesia. However, it remains unknown whether reduced intraoperative tissue oxygenation in obese patients results from obesity per se or from a combination of anesthesia and surgery. In a pilot study, we tested the hypothesis that tissue oxygenation is reduced in spontaneously breathing, unanesthetized obese volunteers. METHODS: Seven lean volunteers with a body mass index (BMI) of 22 +/- 2 kg/m(2) were compared to seven volunteers with a BMI of 46 +/- 4 kg/m(2). Volunteers were subjected to the following oxygen challenges: (1) room air; (2) 2 l/min oxygen via nasal prongs, (3) 6 l/min oxygen through a rebreathing face mask; (4) oxygen as needed to achieve an arterial oxygen pressure (arterial pO(2)) of 200 mmHg; and (5) oxygen as needed to achieve an arterial pO(2) of 300 mmHg. The oxygen challenges were randomized. Arterial pO(2) was measured with a continuous intraarterial blood gas analyzer (Paratrend 7); deltoid subcutaneous tissue oxygenation was measured with a polarographic microoxygen sensor (Licox). RESULTS: Subcutaneous tissue oxygenation was similar in lean and obese volunteers: (1) room air, 52 +/- 10 vs 58 +/- 8 mmHg; (2) 2 l/min, 77 +/- 25 vs 79 +/- 24 mmHg; (3) 6 l/min, 125 +/- 43 vs 121 +/- 25 mmHg; (4) arterial pO(2) = 200 mmHg, 115 +/- 42 vs 144 +/- 23 mmHg; (5) arterial pO(2) = 300 mmHg, 145 +/- 41 vs 154 +/- 32 mmHg. CONCLUSION: In this pilot study, we could not identify significant differences in deltoid subcutaneous tissue oxygen pressure between lean and morbidly obese volunteers.


Assuntos
Obesidade/fisiopatologia , Oxigênio/análise , Tela Subcutânea/química , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Pressão , Magreza , Voluntários
9.
Intensive Care Med ; 34(10): 1883-90, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18516589

RESUMO

OBJECTIVE: Orthogonal polarization spectral (OPS) imaging is used to assess mucosal microcirculation. We tested sensitivity and variability of OPS in the assessment of mesenteric blood flow (Qsma) reduction. SETTING: University Animal Laboratory. INTERVENTIONS: In eight pigs, Qsma was reduced in steps of 15% from baseline; five animals served as controls. Jejunal mucosal microcirculatory blood flow was recorded with OPS and laser Doppler flowmetry at each step. OPS data from each period were collected and randomly ordered. Samples from each period were individually chosen by two blinded investigators and quantified [capillary density (number of vessels crossing predefined lines), number of perfused villi] after agreement on the methodology. MEASUREMENT AND RESULTS: Interobserver coefficient of variation (CV) for capillary density from samples representing the same flow condition was 0.34 (0.04-1.41) and intraobserver CV was 0.10 (0.02-0.61). Only one investigator observed a decrease in capillary density [to 62% (48-82%) of baseline values at 45% Qsma reduction; P = 0.011], but comparisons with controls never revealed significant differences. In contrast, reduction in perfused villi was detected by both investigators at 75% of mesenteric blood flow reduction. Laser Doppler flow revealed heterogeneous microcirculatory perfusion. CONCLUSIONS: Assessment of capillary density did not reveal differences between animals with and without Qsma reduction, and evaluation of perfused villi revealed blood flow reduction only when Qsma was very low. Potential explanations are blood flow redistribution and heterogeneity, and suboptimal contrast of OPS images. Despite agreement on the method of analysis, interobserver differences in the quantification of vessel density on gut mucosa using OPS are high.


Assuntos
Jejuno/irrigação sanguínea , Microvasos/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Análise Espectral/métodos , Animais , Processamento de Imagem Assistida por Computador , Fluxometria por Laser-Doppler , Microvilosidades/fisiologia , Variações Dependentes do Observador , Sensibilidade e Especificidade , Sus scrofa
10.
Anesth Analg ; 106(2): 595-600, table of contents, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18227321

RESUMO

BACKGROUND: The postoperative assessment of volume status is not straightforward because of concomitant changes in intravascular volume and vascular tone. Hypovolemia and blood flow redistribution may compromise the perfusion of the intraabdominal organs. We investigated the effects of a volume challenge in different intra- and extraabdominal vascular beds. METHODS: Twelve pigs were studied 6 h after major intraabdominal surgery under general anesthesia when clinically normovolemic. Volume challenges consisted of 200 mL rapidly infused 6% hydroxyethyl starch. Systemic (continuous thermodilution) and regional (ultrasound Doppler) flows in carotid, renal, celiac trunk, hepatic, and superior mesenteric arteries and the portal vein were continuously measured. The acute and sustained effects of the challenge were compared with baseline. RESULTS: Volume challenge produced a sustained increase of 22% +/- 15% in cardiac output (P < 0.001). Blood flow increased by 10% +/- 9% in the renal artery, by 22% +/- 15% in the carotid artery, by 26% +/- 15% in the superior mesenteric artery, and by 31% +/- 20% in the portal vein (all P < 0.001). Blood flow increases in the celiac trunk (8% +/- 13%) and the hepatic artery (7% +/- 19%) were not significant. Increases in regional blood flow occurred early and were sustained. Mean arterial and central venous blood pressures increased early and decreased later (all P < 0.05). CONCLUSIONS: A volume challenge in clinically euvolemic postoperative animals was associated with a sustained increase in blood flow to all vascular beds, although the increase in the celiac trunk and the hepatic artery was very modest and did not reach statistical significance. Whether improved postoperative organ perfusion is accompanied by a lower complication rate should be evaluated in further studies.


Assuntos
Volume Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Hipovolemia/fisiopatologia , Hipovolemia/prevenção & controle , Masculino , Assistência Perioperatória/métodos , Suínos , Resistência Vascular/fisiologia
11.
Crit Care ; 11(6): R129, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18078508

RESUMO

INTRODUCTION: Vasopressin has been shown to increase blood pressure in catecholamine-resistant septic shock. The aim of this study was to measure the effects of low-dose vasopressin on regional (hepato-splanchnic and renal) and microcirculatory (liver, pancreas, and kidney) blood flow in septic shock. METHODS: Thirty-two pigs were anesthetized, mechanically ventilated, and randomly assigned to one of four groups (n = 8 in each). Group S (sepsis) and group SV (sepsis/vasopressin) were exposed to fecal peritonitis. Group C and group V were non-septic controls. After 240 minutes, both septic groups were resuscitated with intravenous fluids. After 300 minutes, groups V and SV received intravenous vasopressin 0.06 IU/kg per hour. Regional blood flow was measured in the hepatic and renal arteries, the portal vein, and the celiac trunk by means of ultrasonic transit time flowmetry. Microcirculatory blood flow was measured in the liver, kidney, and pancreas by means of laser Doppler flowmetry. RESULTS: In septic shock, vasopressin markedly decreased blood flow in the portal vein, by 58% after 1 hour and by 45% after 3 hours (p < 0.01), whereas flow remained virtually unchanged in the hepatic artery and increased in the celiac trunk. Microcirculatory blood flow decreased in the pancreas by 45% (p < 0.01) and in the kidney by 16% (p < 0.01) but remained unchanged in the liver. CONCLUSION: Vasopressin caused marked redistribution of splanchnic regional and microcirculatory blood flow, including a significant decrease in portal, pancreatic, and renal blood flows, whereas hepatic artery flow remained virtually unchanged. This study also showed that increased urine output does not necessarily reflect increased renal blood flow.


Assuntos
Circulação Hepática/efeitos dos fármacos , Circulação Renal/efeitos dos fármacos , Choque Séptico/fisiopatologia , Circulação Esplâncnica/efeitos dos fármacos , Vasopressinas/farmacologia , Animais , Rim/irrigação sanguínea , Rim/efeitos dos fármacos , Fígado/irrigação sanguínea , Fígado/efeitos dos fármacos , Circulação Hepática/fisiologia , Pâncreas/irrigação sanguínea , Pâncreas/efeitos dos fármacos , Fluxo Sanguíneo Regional/efeitos dos fármacos , Fluxo Sanguíneo Regional/fisiologia , Circulação Renal/fisiologia , Choque Séptico/metabolismo , Circulação Esplâncnica/fisiologia , Suínos
12.
Anesth Analg ; 105(3): 773-9, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17717239

RESUMO

BACKGROUND: Low tissue oxygen tension is an important factor leading to the development of wound dehiscence and anastomotic leakage after colon surgery. We tested whether supplemental fluid and supplemental oxygen can increase tissue oxygen tension in healthy and injured, perianastomotic, and anastomotic colon in an acutely instrumented pig model of anastomosis surgery. METHODS: Sixteen Swiss Landrace pigs were anesthetized (isoflurane 0.8%-1%) and their lungs ventilated. The animals were randomly assigned to low fluid treatment ("low" group, 3 mL x kg(-1) x h(-1) lactated Ringer's solution) or high fluid treatment ("high" group, 10 mL/kg bolus, 18 mL x kg(-1) x h(-1) lactated Ringer's solution) during colon anastomosis surgery and a subsequent measurement period (4 h). Two-and-half hours after surgery, tissue oxygen tension was recorded for 30 min during ventilation with 30% oxygen. Three hours after surgery, the animals' lungs were ventilated with 100% oxygen for 60 min. Tissue oxygen tension was recorded in the last 30 min. Tissue oxygen tension was measured with polarographic Clark-type electrodes, positioned in healthy colonic wall, close (2 cm) to the anastomosis, and in the anastomosis. RESULTS: In every group, tissue oxygen tension during ventilation with 100% oxygen was approximately twice as high as during ventilation with 30% oxygen, a statistically significant result. High or low volume crystalloid fluid treatment had no effect on colon tissue oxygen tension. CONCLUSIONS: Supplemental oxygen, but not supplemental crystalloid fluid, increased tissue oxygen tension in healthy, perianastomotic, and anastomotic colon tissue.


Assuntos
Colo/efeitos dos fármacos , Hidratação/métodos , Soluções Isotônicas/farmacologia , Oxigenoterapia , Oxigênio/farmacologia , Deiscência da Ferida Operatória/prevenção & controle , Anastomose Cirúrgica/efeitos adversos , Animais , Pressão Sanguínea , Dióxido de Carbono/sangue , Débito Cardíaco , Colo/metabolismo , Colo/cirurgia , Soluções Cristaloides , Frequência Cardíaca , Hemoglobinas/metabolismo , Soluções Isotônicas/uso terapêutico , Modelos Animais , Oxigênio/sangue , Oxigênio/uso terapêutico , Pressão Parcial , Pressão Propulsora Pulmonar , Lactato de Ringer , Deiscência da Ferida Operatória/etiologia , Deiscência da Ferida Operatória/metabolismo , Sus scrofa , Fatores de Tempo
13.
Shock ; 26(4): 391-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16980887

RESUMO

We assessed changes in intravascular volume monitored by difference in pulse pressure (dPP%) after stepwise hemorrhage in an experimental pig model. Six pigs (23-25 kg) were anesthetized (isoflurane 1.5 vol%) and mechanically ventilated to keep end-tidal CO2 (etCO2) at 35 mmHg. A PA-catheter and an arterial catheter were placed via femoral access. During and after surgery, animals received lactated Ringer's solution as long as they were considered volume responders (dPP>13%). Then animals were allowed to stabilize from the induction of anesthesia and insertion of catheters for 30 min. After stabilization, baseline measurements were taken. Five percent of blood volume was withdrawn, followed by another 5%, and then in 10%-increments until death from exsanguination occurred. After withdrawal of 5% of blood volume, all pigs were considered volume responders (dPP>13%); dPP rose significantly from 6.1+/-3.3% to 19.4+/-4.2%. The regression analysis of stepwise hemorrhage revealed a linear relation between blood loss (hemorrhage in %) and dPP (y=0.99*x+14; R2=0.7764; P<.0001). In addition, dPP was the only parameter that changed significantly between baseline and a blood loss of 5% (P<0.01), whereas cardiac output, stroke volume, heart rate, MAP, central venous pressure, pulmonary artery occlusion pressure, and systemic vascular resistance, respectively, remained unchanged. We conclude that in an experimental hypovolemic pig model, dPP correlates well with blood loss.


Assuntos
Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Hemorragia/fisiopatologia , Animais , Determinação do Volume Sanguíneo , Suínos
14.
Inflammation ; 32(5): 315-21, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19603262

RESUMO

Catecholamines are frequently used in sepsis, but their interaction with mitochondrial function is controversial. We incubated isolated native and endotoxin-exposed swine liver mitochondria with either dopamine, dobutamine, noradrenaline or placebo for 1 h. Mitochondrial State 3 and 4 respiration and their ratio (RCR) were determined for respiratory chain complexes I, II and IV. All catecholamines impaired glutamate-dependent RCR (p = 0.046), predominantly in native mitochondria. Endotoxin incubation alone induced a decrease in glutamate-dependent RCR compared to control samples (p = 0.002). We conclude that catecholamines and endotoxin impair the efficiency of mitochondrial complex I respiration in vitro.


Assuntos
Catecolaminas/farmacologia , Endotoxinas/farmacologia , Mitocôndrias Hepáticas/metabolismo , Consumo de Oxigênio/efeitos dos fármacos , Difosfato de Adenosina/análise , Difosfato de Adenosina/metabolismo , Trifosfato de Adenosina/biossíntese , Animais , Respiração Celular/fisiologia , Mitocôndrias Hepáticas/efeitos dos fármacos , Suínos , Fatores de Tempo
15.
Anesthesiology ; 106(6): 1156-67, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17525591

RESUMO

BACKGROUND: Vasopressin increases arterial pressure in septic shock even when alpha-adrenergic agonists fail. The authors studied the effects of vasopressin on microcirculatory blood flow in the entire gastrointestinal tract in anesthetized pigs during early septic shock. METHODS: Thirty-two pigs were intravenously anesthetized, mechanically ventilated, and randomly assigned to one of four groups (n=8 in each; full factorial design). Group S (sepsis) and group SV (sepsis-vasopressin) were made septic by fecal peritonitis. Group C and group V were nonseptic control groups. After 300 min, group V and group SV received intravenous infusion of 0.06 U.kg.h vasopressin. In all groups, cardiac index and superior mesenteric artery flow were measured. Microcirculatory blood flow was recorded with laser Doppler flowmetry in both mucosa and muscularis of the stomach, jejunum, and colon. RESULTS: While vasopressin significantly increased arterial pressure in group SV (P<0.05), superior mesenteric artery flow decreased by 51+/-16% (P<0.05). Systemic and mesenteric oxygen delivery and consumption decreased and oxygen extraction increased in the SV group. Effects on the microcirculation were very heterogeneous; flow decreased in the stomach mucosa (by 23+/-10%; P<0.05), in the stomach muscularis (by 48+/-16%; P<0.05), and in the jejunal mucosa (by 27+/-9%; P<0.05), whereas no significant changes were seen in the colon. CONCLUSION: Vasopressin decreased regional flow in the superior mesenteric artery and microcirculatory blood flow in the upper gastrointestinal tract. This reduction in flow and a concomitant increase in the jejunal mucosa-to-arterial carbon dioxide gap suggest compromised mucosal blood flow in the upper gastrointestinal tract in septic pigs receiving low-dose vasopressin.


Assuntos
Trato Gastrointestinal/irrigação sanguínea , Choque Séptico , Circulação Esplâncnica/efeitos dos fármacos , Vasoconstritores/farmacologia , Vasopressinas/farmacologia , Animais , Pressão Sanguínea/efeitos dos fármacos , Trato Gastrointestinal/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Microcirculação/efeitos dos fármacos , Suínos
16.
Crit Care Med ; 34(5): 1456-63, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16557162

RESUMO

OBJECTIVE: The use of vasopressors for treatment of hypotension in sepsis may have adverse effects on microcirculatory blood flow in the gastrointestinal tract. The aim of this study was to measure the effects of three vasopressors, commonly used in clinical practice, on microcirculatory blood flow in multiple abdominal organs in sepsis. DESIGN: Random order, cross-over design. SETTING: University laboratory. SUBJECTS: Eight sedated and mechanically ventilated pigs. INTERVENTIONS: Pigs were exposed to fecal peritonitis-induced septic shock. Mesenteric artery flow was measured using ultrasound transit time flowmetry. Microcirculatory flow was measured in gastric, jejunal, and colon mucosa; jejunal muscularis; and pancreas, liver, and kidney using multiple-channel laser Doppler flowmetry. Each animal received a continuous intravenous infusion of epinephrine, norepinephrine, and phenylephrine in a dose increasing mean arterial pressure by 20%. The animals were allowed to recover for 60 mins after each drug before the next was started. MEASUREMENTS AND MAIN RESULTS: During infusion of epinephrine (0.8 +/- 0.2 mug/kg/hr), mean arterial pressure increased from 66 +/- 5 to 83 +/- 5 mm Hg and cardiac index increased by 43 +/- 9%. Norepinephrine (0.7 +/- 0.3 mug/kg/hr) increased mean arterial pressure from 70 +/- 4 to 87 +/- 5 mm Hg and cardiac index by 41 +/- 8%. Both agents caused a significant reduction in superior mesenteric artery flow (11 +/- 4%, p < .05, and 26 +/- 6%, p < .01, respectively) and in microcirculatory blood flow in the jejunal mucosa (21 +/- 5%, p < .01, and 23 +/- 3%, p < .01, respectively) and in the pancreas (16 +/- 3%, p < .05, and 8 +/- 3%, not significant, respectively). Infusion of phenylephrine (3.1 +/- 1.0 mug/kg/min) increased mean arterial pressure from 69 +/- 5 to 85 +/- 6 mm Hg but had no effects on systemic, regional, or microcirculatory flow except for a 30% increase in jejunal muscularis flow (p < .01). CONCLUSIONS: Administration of the vasopressors phenylephrine, epinephrine, and norepinephrine failed to increase microcirculatory blood flow in most abdominal organs despite increased perfusion pressure and-in the case of epinephrine and norepinephrine-increased systemic blood flow. In fact, norepinephrine and epinephrine appeared to divert blood flow away from the mesenteric circulation and decrease microcirculatory blood flow in the jejunal mucosa and pancreas. Phenylephrine, on the other hand, appeared to increase blood pressure without affecting quantitative blood flow or distribution of blood flow.


Assuntos
Epinefrina/farmacologia , Norepinefrina/farmacologia , Fenilefrina/farmacologia , Choque Séptico/tratamento farmacológico , Circulação Esplâncnica/efeitos dos fármacos , Vasoconstritores/farmacologia , Análise de Variância , Animais , Pressão Sanguínea/efeitos dos fármacos , Estudos Cross-Over , Hemodinâmica/efeitos dos fármacos , Intestinos/irrigação sanguínea , Fígado/irrigação sanguínea , Microcirculação/efeitos dos fármacos , Pâncreas/irrigação sanguínea , Distribuição Aleatória , Suínos
17.
Crit Care Med ; 34(9): 2406-14, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16878039

RESUMO

OBJECTIVE: The aim of this study was to assess the microcirculatory and metabolic consequences of reduced mesenteric blood flow. DESIGN: Prospective, controlled animal study. SETTING: The surgical research unit of a university hospital. SUBJECTS: A total of 13 anesthetized and mechanically ventilated pigs. INTERVENTIONS: Pigs were subjected to stepwise mesenteric blood flow reduction (15% in each step, n = 8) or served as controls (n = 5). Superior mesenteric arterial blood flow was measured with ultrasonic transit time flowmetry, and mucosal and muscularis microcirculatory perfusion in the small bowel were each measured with three laser Doppler flow probes. Small-bowel intramucosal Pco2 was measured by tonometry, and glucose, lactate (L), and pyruvate (P) were measured by microdialysis. MEASUREMENTS AND MAIN RESULTS: In control animals, superior mesenteric arterial blood flow, mucosal microcirculatory blood flow, intramucosal Pco2, and the lactate/pyruvate ratio remained unchanged. In both groups, mucosal blood flow was better preserved than muscularis blood flow. During stepwise mesenteric blood flow reduction, heterogeneous microcirculatory blood flow remained a prominent feature (coefficient of variation, approximately 45%). A 30% flow reduction from baseline was associated with a decrease in microdialysis glucose concentration from 2.37 (2.10-2.70) mmol/L to 0.57 (0.22-1.60) mmol/L (p < .05). After 75% flow reduction, the microdialysis lactate/pyruvate ratio increased from 8.6 (8.0-14.1) to 27.6 (15.5-37.4, p < .05), and arterial-intramucosal Pco2 gradients increased from 1.3 (0.4-3.5) kPa to 10.8 (8.0-16.0) kPa (p < .05). CONCLUSIONS: Blood flow redistribution and heterogeneous microcirculatory perfusion can explain apparently maintained regional oxidative metabolism during mesenteric hypoperfusion, despite local signs of anaerobic metabolism. Early decreasing glucose concentrations suggest that substrate supply may become crucial before oxygen consumption decreases.


Assuntos
Glucose/metabolismo , Mucosa Intestinal/metabolismo , Jejuno/irrigação sanguínea , Jejuno/metabolismo , Artéria Mesentérica Superior/fisiologia , Animais , Oclusão com Balão , Biomarcadores/metabolismo , Dióxido de Carbono/metabolismo , Duodeno/irrigação sanguínea , Duodeno/metabolismo , Mucosa Intestinal/irrigação sanguínea , Ácido Láctico/metabolismo , Fluxometria por Laser-Doppler , Mesentério/fisiologia , Microcirculação , Músculo Liso Vascular/irrigação sanguínea , Consumo de Oxigênio/fisiologia , Veia Porta , Estudos Prospectivos , Ácido Pirúvico/metabolismo , Fluxo Sanguíneo Regional , Suínos
18.
Anesthesiology ; 100(5): 1188-97, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15114217

RESUMO

BACKGROUND: Insufficient blood flow to the splanchnic organs is believed to be an important contributory factor for the development of organ failure after septic shock. It has been suggested that increasing systemic flow also may improve splanchnic blood flow in septic patients. The aim of this study was to compare the effects of three commonly used inotropic agents, dopamine, dobutamine, and dopexamine, on systemic (cardiac index), regional (superior mesenteric artery), and local (micro-circulatory) blood flow during septic shock in pigs. METHODS: Eight pigs were intravenously anesthetized, mechanically ventilated, and exposed to sepsis induced by fecal peritonitis. Cardiac index was measured with thermodilution, superior mesenteric artery flow was measured with ultrasound transit time flowmetry, and microcirculatory blood flow was continuously measured with a six-channel laser Doppler flowmetry in the gastric, jejunal, and colon mucosa as well as in the kidney, pancreas, and jejunal muscularis. Each animal received, in a random-order, crossover design, the three test drugs, one at a time: 5 and 10 microg x kg(-1) x min(-1) dopamine, 5 and 10 microg x kg(-1) x min(-1) dobutamine, and 1 and 2 microg x kg(-1) x min(-1) dopexamine. Administration of each drug at each dose continued for 30 min and was followed by a 40- to 60-min recovery period. A new baseline was taken before the next drug was administered. RESULTS: All three drugs significantly increased cardiac index; dopamine by 18%, dobutamine by 48%, and dopexamine by 35%, compared with baseline (P < 0.001 for each). At the same time, superior mesenteric artery flow increased by 33% (P < 0.01) with dopamine and 13% (P < 0.01) with dopexamine, whereas it did not change with dobutamine. Microcirculatory blood flow did not change significantly in any of the organs studied with any of the drugs tested. CONCLUSION: All the inotropic agents markedly increased cardiac output in this sepsis model. However, increased systemic flow did not reach the microcirculation in the gastrointestinal tract. This may in part explain why some of the clinical trials, in which systemic oxygen delivery was deliberately increased by administration of inotropic drugs, have failed to improve survival in critically ill patients.


Assuntos
Dobutamina/farmacologia , Dopamina/análogos & derivados , Dopamina/farmacologia , Trato Gastrointestinal/irrigação sanguínea , Trato Gastrointestinal/efeitos dos fármacos , Animais , Trato Gastrointestinal/fisiologia , Microcirculação/efeitos dos fármacos , Microcirculação/fisiologia , Choque Séptico/fisiopatologia , Suínos
19.
Crit Care Med ; 31(1): 203-10, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12545016

RESUMO

OBJECTIVE: Splanchnic ischemia is believed to play an important role in the development of multiple organ dysfunction in septic shock. The vasoconstrictor peptide endothelin can produce an intense and sustained splanchnic vasoconstriction and is increased in sepsis. The aim of this investigation was to study the effects of an endothelin antagonist on microcirculatory blood flow in multiple abdominal organs during septic shock. DESIGN: Prospective, controlled animal study. SETTING: University-affiliated research laboratory. SUBJECTS: Fifteen anesthetized and mechanically ventilated pigs. INTERVENTIONS: Septic shock was induced by fecal peritonitis. After 120 mins of sepsis, eight animals received 10 mg/kg bosentan intravenously followed by an intravenous infusion at 5 mg x kg-1 x hr-1 whereas seven (controls) received isotonic saline. At 240 mins after induction of sepsis both groups received hydroxyethyl starch, 20 mL/kg intravenously, to convert hypodynamic septic shock to hyperdynamic sepsis. MEASUREMENTS AND MAIN RESULTS: Microcirculatory blood flow was measured simultaneously and continuously in the jejunal muscularis, pancreas, liver, kidney, skeletal muscle, and gastric, jejunal, and colon mucosa by using a multiple-channel laser Doppler flow meter. After 120 mins, all animals had developed signs of hypodynamic sepsis with decreased cardiac index, mean arterial blood pressure, and gastric mucosal pH. Microcirculatory blood flow in the pancreas and liver had decreased by 20% and in the jejunal muscularis by >40% (p <.01) whereas it remained virtually unchanged in the gastric, jejunal, and colonic mucosa. After 240 mins, cardiac index, mean arterial blood pressure, gastric mucosal pH, and microcirculatory blood flow in the gastric mucosa, colon mucosa, jejunal muscularis, and pancreas had all deteriorated in the controls, whereas in the bosentan-treated group, cardiac index and microcirculatory blood flow in the pancreas, gastric, and colon mucosa improved. During hyperdynamic sepsis, cardiac index increased above baseline in both groups but significantly more in the bosentan group. In the control group, microcirculatory flow returned to baseline in most tissues except in skeletal muscle and jejunal muscularis. In the bosentan group, microcirculatory flow returned to or increased above baseline in all tissues except in the muscularis of the jejunum. CONCLUSIONS: The endothelin receptor antagonist bosentan significantly improved microcirculatory blood flow in many splanchnic organs and in peripheral tissues during septic shock. The results of this study are consistent with the hypothesis that endothelin plays an important role in the regulation of microcirculatory blood flow in splanchnic as well as in peripheral tissues during septic shock.


Assuntos
Anti-Hipertensivos/farmacologia , Endotelinas/fisiologia , Choque Séptico/fisiopatologia , Circulação Esplâncnica/efeitos dos fármacos , Sulfonamidas/farmacologia , Equilíbrio Ácido-Base , Análise de Variância , Animais , Bosentana , Mucosa Gástrica/irrigação sanguínea , Mucosa Gástrica/química , Mucosa Gástrica/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Microcirculação/efeitos dos fármacos , Microcirculação/fisiologia , Circulação Esplâncnica/fisiologia , Estatísticas não Paramétricas , Suínos
20.
Anesthesiology ; 98(3): 658-69, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12606910

RESUMO

BACKGROUND: Hypoperfusion of the intestinal mucosa remains an important clinical problem during sepsis. Impairment of the autoregulation of microcirculatory blood flow in the intestinal tract has been suggested to play an important role in the development of multiple organ failure during sepsis and surgery. The authors studied microcirculatory blood flow in the gastrointestinal tract in anesthetized subjects during early septic shock. METHODS: Eighteen pigs were intravenously anesthetized and mechanically ventilated. Regional blood flow in the superior mesenteric artery was measured with ultrasound transit time flowmetry. Microcirculatory blood flow was continuously measured with a six-channel laser Doppler flowmetry system in the mucosa and the muscularis of the stomach, jejunum, and colon. Eleven pigs were assigned to the sepsis group, while seven animal served as sham controls. Sepsis was induced with fecal peritonitis, and intravenous fluids were administered after 240 min of sepsis to alter hypodynamic sepsis to hyperdynamic sepsis. RESULTS: In the control group, all monitored flow data remained stable throughout the study. During the hypodynamic phase of sepsis, cardiac output, superior mesenteric artery flow, and microcirculatory blood flow in the gastric mucosa decreased by 45%, 51%, and 40%, respectively, compared to baseline (P < 0.01 in all). Microcirculatory blood flow in the muscularis of the stomach, jejunum, and colon decreased by 55%, 64%, and 70%, respectively (P < 0.001 in all). In contrast, flow in the jejunal and colonic mucosa remained virtually unchanged. During the hyperdynamic phase of sepsis, there was a threefold increase in cardiac output and superior mesenteric artery flow. Blood flow in the gastric, jejunal, and colonic mucosa also increased (22%, 24%, and 31% above baseline, respectively). Flow in the muscularis of the stomach returned to baseline, while in the jejunum and colon, flow in the muscularis remained significantly below baseline (55% and 45%, respectively, P< 0.01). CONCLUSIONS: It appears that in early septic shock, autoregulation of microcirculatory blood flow is largely intact in the intestinal mucosa in anesthetized pigs, explaining why microcirculatory blood flow remained virtually unchanged. This may be facilitated through redistribution of flow within the intestinal wall, from the muscularis toward the mucosa.


Assuntos
Mucosa Intestinal/irrigação sanguínea , Choque Séptico/fisiopatologia , Anestesia Geral , Animais , Concentração de Íons de Hidrogênio , Ácido Láctico/sangue , Microcirculação/fisiologia , Oxigênio/metabolismo , Fluxo Sanguíneo Regional , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA