Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Nano Lett ; 22(8): 3447-3456, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35411774

RESUMO

Transient power sources with excellent biocompatibility and bioresorablility have attracted significant attention. Here, we report high-performance, transient glucose enzymatic biofuel cells (TEBFCs) based on the laser-induced graphene (LIG)/gold nanoparticles (Au NPs) composite electrodes. Such LIG electrodes can be easily fabricated from polyimide (PI) with an infrared CO2 laser and exhibit a low impedance (16 Ω). The resulted TEBFC yields a high open circuit potential (OCP) of 0.77 V and a maximum power density of 483.1 µW/cm2. The TEBFC not only exhibits a quick response time that enables reaching the maximum OCP within 1 min but also owns a long lifetime over 28 days in vitro. The excellent biocompatibility and transient performance from in vitro and in vivo tests allow long-term implantation of TEBFCs in rats for energy harvesting. The TEBFCs with advanced processing methods provide a promising power solution for transient electronics.


Assuntos
Fontes de Energia Bioelétrica , Grafite , Nanopartículas Metálicas , Animais , Eletrodos , Ouro , Lasers , Ratos
2.
Sci Adv ; 10(41): eadp8804, 2024 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-39383239

RESUMO

Monitoring soft-tissue biomechanics is of interest in biomedical research and clinical treatment of diseases. An important focus is biointegrated strain gauges that track time-dependent mechanics of targeted tissues with deforming surfaces over multidirections. Existing methods provide limited gauge factors, tailored for sensing within specific directions under quasi-static conditions. We present development and applicability of implantable/wearable strain gauges that integrate multiple ultrathin monocrystalline silicon-based sensors aligned with different directions, in stretchable formats for dynamically monitoring direction angle-sensitive strain. We experimentally and computationally establish operational principles, with theoretical systems that enable determination of intensities and direction of applied strains at an omnidirectional scale. Wearable evaluations range from cardiac pulse to intraocular pressure monitoring of eyeballs. The device can evaluate cardiac disorders of myocardial infarction and hypoxia of living rats and locate the pathological orientation associated with infarction, in designs with possibilities as biodegradable implants for stable operation. These findings create clinical significance of the devices for monitoring complex dynamic biomechanics.


Assuntos
Silício , Dispositivos Eletrônicos Vestíveis , Silício/química , Animais , Ratos , Fenômenos Biomecânicos , Próteses e Implantes , Humanos , Estresse Mecânico , Infarto do Miocárdio
3.
Biosens Bioelectron ; 267: 116786, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39326320

RESUMO

Technologies that established in vivo evaluations of soft-tissue biomechanics and temperature are essential to biological research and clinical diagnostics, particularly for a wide range of eye-related diseases such as glaucoma. Of importance are advanced bioelectronic devices for high-precise monitoring of intraocular pressure (IOP) and various ocular temperatures, as clinically proven uses for glaucoma diagnosis. Existing characterization methods are temporary, single point, and lack microscale resolution, failing to measure continuous IOP fluctuation across the long-term period. Here, this work presents a multi-functional smart contact lens, capable of rapidly capturing IOP fluctuation and ocular surface temperature (OST) for assistance for clinical use. The microscale device design is programmable and determined by finite element analysis simulation, with detailed experiments of ex vivo porcine eyeballs. Such compact bioelectronics can provide high-precise measurement with sensitivity of 0.03% mmHg-1 and 1.2 Ω °C-1 in the range of Δ2∼50 mmHg and 30-50 °C, respectively. In vivo tests of bio-integration with a living rabbit can evaluate real-time IOP fluctuation and OST, as of biocompatibility assessments verified through cellular and animal experiments. The resultant bioelectronic devices for continuous precise characterization of living eyeballs can offer broad utility for hospital diagnosis of a wide range of eye-related disorders.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA