Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiother Oncol ; 74(1): 53-9, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15683670

RESUMO

BACKGROUND AND PURPOSE: To assess the geometric accuracy of the delivery of fractionated stereotactic radiotherapy (FSRT) for brain tumours using the Gill-Thomas-Cosman (GTC) relocatable frame. Accuracy of treatment delivery was measured via portal images acquired with an amorphous silicon based electronic portal imager (EPI). Results were used to assess the existing verification process and to review the current margins used for the expansion of clinical target volume (CTV) to planning target volume (PTV). PATIENTS AND METHODS: Patients were immobilized in a GTC frame. Target volume definition was performed on localization CT and MRI scans and a CTV to PTV margin of 5mm (based on initial experience) was introduced in 3D. A Brown-Roberts-Wells (BRW) fiducial system was used for stereotactic coordinate definition. The existing verification process consisted of an intercomparison of the coordinates of the isocentres and anatomy between the localization and verification CT scans. Treatment was delivered with 6 MV photons using four fixed non-coplanar conformal fields using a multi-leaf collimator. Portal imaging verification consisted of the acquisition of orthogonal images centred through the treatment isocentre. Digitally reconstructed radiographs (DRRs) created from the CT localization scans were used as reference images. Semi-automated matching software was used to quantify set up deviations (displacements and rotations) between reference and portal images. RESULTS: One hundred and twenty six anterior and 123 lateral portal images were available for analysis for set up deviations. For displacements, the total errors in the cranial/caudal direction were shown to have the largest SD's of 1.2 mm, while systematic and random errors reached SD's of 1.0 and 0.7 mm, respectively, in the cranial/caudal direction. The corresponding data for rotational errors (the largest deviation was found in the sagittal plane) was 0.7 degrees SD (total error), 0.5 degrees (systematic) and 0.5 degrees (random). The total 3D displacement was 1.8 mm (mean), 0.8 mm (SD) with a range of 0.3-3.9 mm. CONCLUSIONS: Portal imaging has shown that the existing verification and treatment delivery techniques currently in use result in highly reproducible setups. Random and systematic errors in the treatment planning and delivery chain will always occur, but monitoring and minimising them is an essential component of quality control. Portal imaging provides fast and accurate facility for monitoring patients on treatment and the results of this study have shown that a reduction in CTV to PTV margin from 5 to 4 mm (resulting in a considerable increase in the volume of normal tissue sparing) could be made.


Assuntos
Adenoma/radioterapia , Craniofaringioma/radioterapia , Neoplasias Meníngeas/radioterapia , Meningioma/radioterapia , Neuroma Acústico/radioterapia , Neoplasias Hipofisárias/radioterapia , Radioterapia/métodos , Técnicas Estereotáxicas , Fracionamento da Dose de Radiação , Humanos , Imobilização , Imageamento por Ressonância Magnética , Fótons/uso terapêutico , Sensibilidade e Especificidade , Silício , Tomografia Computadorizada por Raios X
2.
Radiother Oncol ; 77(1): 39-44, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16154217

RESUMO

PURPOSE: To evaluate set-up reproducibility of a cabulite shell and determine CTV-PTV margins for head and neck intensity-modulated-radiotherapy. MATERIALS AND METHODS: Twenty patients were entered into the study. A total of 354 anterior and lateral isocentric electronic portal images (EPIs) were compared to simulator reference images. RESULTS: About 94% of all translational displacements were < or =3 mm, and 99% < or =5 mm. The overall systematic error was 0.9 mm (+/-1.0SD) in the Right-Left, 0.7 mm (+/-0.9SD) in the Superior-Inferior and -0.02 mm (+/-1.1SD) in the Anterior-Posterior directions. The corresponding SDs of the random errors were +/-0.4, +/-0.6 and +/-0.7 mm. The estimated margins required from CTV-PTV were calculated according to the Van Herk formula was 2.9, 2.6 and 3.3 mm, respectively. CONCLUSIONS: This head and neck immobilisation system is of sufficient accuracy for its use with IMRT treatments and a 3 mm CTV-PTV margin has been adopted.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Imobilização/instrumentação , Relação Dose-Resposta à Radiação , Eletrônica , Desenho de Equipamento , Humanos , Lesões por Radiação/prevenção & controle , Radioterapia/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA