Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 29(Pt 3): 670-676, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35511000

RESUMO

This work has successfully demonstrated a system for monitoring pink-beam X-rays exiting from a beamline front-end, which has a specific spatial distribution based on each energy component. In this study, the X-rays scattered from a single-crystal chemical-vapor-deposited diamond film were converted into a cross-sectional image using pinhole optics, followed by digitization with a direct detection complementary metal-oxide-semiconductor 2D detector. By using single crystals instead of poly-crystals, good quality images were obtained with no diffraction bright spots. As a result of applying photon energy discrimination using the droplet analysis to the image information, the spatial distribution of each energy component of the undulator radiation was successfully visualized. The result was found to be in good agreement with the theoretically calculated result obtained using the synchrotron radiation calculation code SPECTRA. The new synchrotron radiation beam monitor proposed in this paper can serve as a powerful beam diagnostic tool for diffraction-limited rings that require strict light source stability.

2.
J Synchrotron Radiat ; 26(Pt 2): 585-594, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30855271

RESUMO

An experimental platform using X-ray free-electron laser (XFEL) pulses with high-intensity optical laser pulses is open for early users' experiments at the SACLA XFEL facility after completion of the commissioning. The combination of the hard XFEL and the high-intensity laser provides capabilities to open new frontiers of laser-based high-energy-density science. During the commissioning phase, characterization of the XFEL and the laser at the platform has been carried out for the combinative utilization as well as the development of instruments and basic diagnostics for user experiments. An overview of the commissioning and the current capabilities of the experimental platform is presented.

3.
Rev Sci Instrum ; 91(3): 033103, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32259919

RESUMO

With low-emittance synchrotron radiation rings, introducing accurate x-ray beams to a sample is difficult, and ensuring that the direction of the undulator beam is stable is essential. However, measuring the centroid of the undulator photon beam at the beamline front-end (FE) is difficult because the soft x-ray radiation is contaminated by the bending magnets upstream and downstream of the undulator. The x-ray beam position monitors (XBPMs), based on the interaction with the halo of undulator radiation, cannot estimate the centroid of the beam, and they cannot eliminate the effects of the bending magnets. To solve this problem, we have developed an energy-resolved beam-monitoring system for undulator radiation with the scattering from a diamond thin film deposited by chemical vapor deposition (CVD) in this study. An undulator x-ray beam is irradiated onto this film, and its elastic and Compton scattering are observed through a 50 µm-diameter pinhole. A beam spot is detected through a pinhole camera system using a direct-detection-type charge-coupled device camera with energy resolution. The peak of the first-order harmonic of the undulator radiation is selectively visualized to measure the centroid of the undulator radiation, as well as the spectrum. The proposed system using a CVD diamond film can provide accurate position information for a photon beam exiting the FE.

4.
Sci Rep ; 6: 37937, 2016 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-27897218

RESUMO

We report an unexpectedly large flux loss observed in permanent magnets in one of the undulators operated in SACLA, the x-ray free electron laser facility in Japan. Characterizations of individual magnets extracted from the relevant undulator have revealed that the flux loss was caused by a homogeneous magnetization reversal extending over a wide area, but not by demagnetization of individual magnets damaged by radiation. We show that the estimated flux-loss rate is much higher than what is reported in previous papers, and its distribution is much more localized to the upstream side. Results of numerical and experimental studies carried out to validate the magnetization reversal and quantify the flux loss are presented, together with possible countermeasures against rapid degradation of the undulator performance.

5.
Radiat Prot Dosimetry ; 146(1-3): 96-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21493607

RESUMO

Superheated drop detectors are currently used for personal and environmental dosimetry and their characteristics such as response to neutrons and temperature dependency are well known. A new bubble counter based on the superheated drop technology has been developed by Framework Scientific. However, the response of this detector with the lead shell is not clear especially above several tens of MeV. In this study, the response has been measured with quasi-monoenergetic and monoenergetic neutron sources with and without a lead shell. The experimental results were compared with the results of the Monte Carlo calculations using the 'Event Generator Mode' in the PHITS code with the JENDL-HE/2007 data library to clarify the response of this detector with a lead shell in the entire energy range.


Assuntos
Chumbo/química , Nêutrons , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Temperatura Alta , Humanos , Microbolhas , Método de Monte Carlo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA