Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(7)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37050505

RESUMO

Piezoelectric composites, which consist of a piezoelectric material and a polymer, have been extensively studied for the applications of underwater sonar sensors and medical diagnostic ultrasonic transducers. Acoustic sensors utilizing piezoelectric composites can have a high sensitivity and wide bandwidth because of their high piezoelectric coefficient and low acoustic impedance compared to single-phase piezoelectric materials. In this study, a thickness-mode driving hydrophone utilizing a 2-2 piezoelectric single crystal composite was examined. From the theoretical and numerical analysis, material properties that determine the bandwidth and sensitivity of the thickness-mode piezoelectric plate were derived, and the voltage sensitivity of piezoelectric plates with various configurations was compared. It was shown that the 2-2 composite with [011] poled single crystals and epoxy polymers can provide high sensitivity and wide bandwidth when used for hydrophones with a thickness resonance mode. The hydrophone element was designed and fabricated to have a thickness mode at a frequency around 220 kHz by attaching a composite plate of quarter-wavelength thickness to a hard baffle. The fabricated hydrophone demonstrated an open circuit voltage sensitivity of more than -180 dB re 1 V/µPa at the resonance frequency and a -3 dB bandwidth of more than 55 kHz. The theoretical and experimental studies show that the 2-2 single crystal composite can have a high sensitivity and wide bandwidth compared to other configurations of piezoelectric elements when they are used for thickness-mode hydrophones.

2.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617118

RESUMO

Underwater detection is accomplished using an underwater ultrasonic sensor, sound navigation and ranging (SONAR). Stealth to avoid detection by SONAR plays a major role in modern underwater warfare. In this study, we propose a smart skin that avoids detection by SONAR via controlling the signal reflected from an unmanned underwater vehicle (UUV). The smart skin is a multilayer transducer composed of an acoustic window, a double-layer receiver, and a single-layer transmitter. It separates the incident signal from the reflected signal from outside through the time-delay separation method and cancels the reflected wave from the phase-shifted transmission sound. The characteristics of the receiving and transmitting sensors were analyzed using a finite element analysis. Three types of devices were compared in the design of the sensors. Polyvinylidene fluoride (PVDF), which had little effect on the transmitted sound, was selected as the receiving sensor. A stacked piezoelectric transducer with high sensitivity compared to a cymbal transducer was used as the transmitter. The active reflection control system was modeled and verified using 2D 360° reflection experiments. The stealth effect that could be achieved by applying a smart skin to a UUV was presented through an active reflection-control omnidirectional reflection model.

3.
J Acoust Soc Am ; 137(4): 1732-43, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25920826

RESUMO

Parametric array (PA) loudspeakers generate directional audible sound via the PA effect, which can make private listening possible. The practical applications of PA loudspeakers include information technology devices that require large power efficiency transducers with a wide frequency bandwidth. Piezoelectric micromachined ultrasonic transducers (PMUTs) are compact and efficient units for PA sources [Je, Lee, and Moon, Ultrasonics 53, 1124-1134 (2013)]. This study investigated the use of an array of PMUTs to make a PA loudspeaker with high power efficiency and wide bandwidth. The achievable maximum radiation bandwidth of the driver was calculated, and an array of PMUTs with two distinct resonance frequencies (f1 = 100 kHz, f2 = 110 kHz) was designed. Out-of-phase driving was used with the dual-resonance transducer array to increase the bandwidth. The fabricated PMUT array exhibited an efficiency of up to 71%, together with a ±3-dB bandwidth of 17 kHz for directly radiated primary waves, and 19.5 kHz (500 Hz to 20 kHz) for the difference frequency waves (with equalization).


Assuntos
Acústica/instrumentação , Amplificadores Eletrônicos , Eletrônica , Desenho de Equipamento , Som , Transdutores
4.
Micromachines (Basel) ; 15(7)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39064428

RESUMO

Piezoelectric composites, which consist of piezoelectric materials and polymers, are widely employed in various applications such as underwater sonar transducers and medical diagnostic ultrasonic transducers. Acoustic transducers based on piezoelectric composites can have high sensitivity with broad bandwidth. In recent studies, it is demonstrated that 2-2 composites based on single crystals provide further increased sensitivity and wide bandwidth. In order to utilize a 2-2 composite in acoustic sensors, it is required to demonstrate the full material coefficients of the 2-2 composite. In this study, we investigated an analytic solution for determining equivalent material coefficients of a 2-2 composite. Impedance spectrums of the single-phase resonators with equivalent material coefficients and 2-2 composite resonators were compared by the finite element method in order to verify the analytic solutions. Furthermore, the equivalent material coefficients derived from the analytic solution were also verified by comparing the measured and the simulated impedance spectrums. The difference in resonance and anti-resonance frequencies between the measured and simulated impedance spectrums was around 0.5% and 1.2%. By utilizing the analytic solutions in this study, it is possible to accurately derive full equivalent material coefficients of a 2-2 composite, which are essential for the development of acoustic sensors.

5.
J Acoust Soc Am ; 127(6): 3494-502, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20550249

RESUMO

An ultrasonic radiator is developed to generate a difference frequency sound from two frequencies of ultrasound in air with a parametric array. A design method is proposed for an ultrasonic radiator capable of generating highly directive, high-amplitude ultrasonic sound beams at two different frequencies in air based on a modification of the stepped-plate ultrasonic radiator. The stepped-plate ultrasonic radiator was introduced by Gallego-Juarez et al. [Ultrasonics 16, 267-271 (1978)] in their previous study and can effectively generate highly directive, large-amplitude ultrasonic sounds in air, but only at a single frequency. Because parametric array sources must be able to generate sounds at more than one frequency, a design modification is crucial to the application of a stepped-plate ultrasonic radiator as a parametric array source in air. The aforementioned method was employed to design a parametric radiator for use in air. A prototype of this design was constructed and tested to determine whether it could successfully generate a difference frequency sound with a parametric array. The results confirmed that the proposed single small-area transducer was suitable as a parametric radiator in air.

6.
Ultrasonics ; 53(6): 1124-34, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23541961

RESUMO

The use of micromachined thin-film ultrasonic radiators to improve the efficiency of conventional in-air acoustic transducers is investigated. We conduct a theoretical investigation of the parameters that determine the efficiency of thin-film transducers, using a lumped parameter model, and show that the efficiency can be improved by choosing a radiating plate thickness that can be realized by micromachining. We also identified the problems that should be overcome to design and fabricate a micromachined ultrasonic transducer with the theoretically predicted efficiency. Based on the lumped parameter model, we showed that the problems can be resolved via an appropriate design scheme. A piezoelectric micromachined ultrasonic transducer is designed and fabricated to demonstrate the impact of the proposed design method. Test results for the fabricated radiator indicated that it provided an electroacoustic efficiency of 58.4%, up to 300% greater than either the unit previously fabricated by the authors or conventional unimorph ultrasonic transducers. An array of the proposed transducers was also designed, fabricated, and tested as a source transducer for a parametric array, since transducer efficiency is important for practical applications of a parametric array. The test results for the proposed transducer demonstrate its potential for improving the practicality of parametric array sources, such as parametric loudspeakers and directional ultrasonic ranging sensors.

7.
Ultrasonics ; 50(3): 340-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19919873

RESUMO

This paper introduces a novel method for designing the transducer of a highly directional ultrasonic range sensor for detecting obstacles in mobile robot applications. The transducer consists of wave generation, amplification, and radiation sections, and a countermass. The operating principle of this design is based on the parametric array method where the frequency difference between two ultrasonic waves is used to generate a highly directional low-frequency wave with a small aperture. The aim of this study was to design an optimal transducer to generate the two simultaneous longitudinal modes efficiently. We first derived an appropriate mathematical model by combining the continuum model of a bar and countermass with the compatibility condition between a piezoelectric actuator and a linear horn. Then we determined the optimal length of the aluminum horn and the piezoelectric actuator using a finite element method. The proposed sensor exhibited a half-power bandwidth of less than+/-1.3 degrees at 44.8 kHz, a much higher directivity than existing conventional ultrasonic range sensors.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Sistemas Microeletromecânicos/instrumentação , Radar/instrumentação , Transdutores , Ultrassonografia/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA