Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Lett ; 47(23): 6193-6196, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37219205

RESUMO

We fabricate a novel, to the best of our knowledge, acousto-optic Q switch in the 3-micron wavelength range using a longitudinal acoustic mode in a lithium niobate (LiNbO3) crystal. The device is designed based on properties of the crystallographic structure and material to obtain a high diffraction efficiency close to the theoretical prediction. The effectiveness of the device is verified by application in an Er,Cr:YSGG laser at 2.79 µm. The maximum diffraction efficiency reached 57% at the radio frequency of 40.68 MHz. At the repetition rate of 50 Hz, the maximum pulse energy was 17.6 mJ and the corresponding pulse width was 55.2 ns. The effectiveness of bulk LiNbO3 as an acousto-optic Q switch is verified for the first time.

2.
Lasers Med Sci ; 37(8): 3285-3290, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35951123

RESUMO

OBJECTIVE: The study aimed to evaluate the bond strength of universal adhesives to dentin after Er,Cr:YSGG laser irradiation with nanosecond-domain and microsecond-domain pulses. METHODS: Eighty extracted caries-free, sound human molars were divided into eight groups. The enamel was removed until the dentin occlusal flat dentin surface was exposed. Etch-and-rinse followed by adhesive was applied to group 1, and a self-etch adhesive was applied to group 2. Er,Cr:YSGG laser (3 mJ, 100 Hz, 100 ns), (3 mJ, 100 Hz, 150 µs), and (20 mJ, 100 Hz, 150 µs) were applied to groups 3-4, 5-6, and 7-8, respectively. The laser preparation was followed by self-etch adhesives or adhesives treatment. When the composite resin had been built up on the samples, the shear bond strength was tested, and the data were statistically analyzed using analysis of variance (ANOVA). RESULTS: Groups prepared with nanosecond-pulse laser showed significantly higher bond strength values than the microsecond-pulse laser groups and self-etch mode group, and the SEM photographs also showed more dentinal tubules and no damage in the ablation area. The shear bond strength of long pulse laser ablated was comparable to that of self-etching system when it was combined with a self-etch adhesive at low energy, but higher energy laser degraded shear bond strength. CONCLUSIONS: The pulse width of Er,Cr:YSGG laser affects the bond strength, nanosecond pulses of laser irradiation without water cooling can enhance bond strength, but microsecond pulses of laser cannot enhance bond strength.


Assuntos
Colagem Dentária , Terapia a Laser , Lasers de Estado Sólido , Adesivos , Resinas Compostas/química , Dentina/efeitos da radiação , Humanos , Lasers de Estado Sólido/uso terapêutico , Resistência ao Cisalhamento , Água
3.
Opt Lett ; 46(19): 5016-5018, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598256

RESUMO

We report on a high-peak-power electro-optically Q-switched laser emitting a near-diffraction-limited beam profile at 1064 nm by using a gradient-doped Nd:YAG crystal. The gradient-doped crystal features a unique combination of a reduced thermal lens effect through effectively spreading the heat load distribution within its volume. Its performance is compared with those of Nd:YAG crystals with uniform volume doping distribution operating in the Q-switched regime with the same laser configuration, demonstrating the higher average and peak power achievable with the gradient-doped crystal. The maximum average output power amounts to 6.9 W at a pulse repetition rate of 2 kHz, which corresponds to a maximum peak power of ∼585kW. Compared to homogeneous dopant crystals, the slope efficiency and average output power increased by 30.8% and 21.1%, respectively.

4.
Opt Lett ; 44(9): 2201-2203, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31042183

RESUMO

A mid-infrared BaGa4Se7 optical parametric oscillator with high conversion efficiency and beam quality is demonstrated, which is pumped by a 2.79-µm electro-optically Q-switched Cr, Er:YSGG laser. A pulse energy of 3.5 mJ with a pulse width of 21 ns at 10 Hz is obtained in the range of 3.94-9.55 µm, and the beam quality factors are measured to be Mx2=5.0 and My2=4.6. The optical-to-optical conversion efficiency is 18.9%, and the slope efficiency is 31.6%, which is a 59% improvement on the best of the previously reported slope efficiencies for BaGa4Se7-based OPOs.

5.
Sensors (Basel) ; 18(2)2018 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-29461469

RESUMO

Gas utilization ratio (GUR) is an important indicator that is used to evaluate the energy consumption of blast furnaces (BFs). Currently, the existing methods cannot predict the GUR accurately. In this paper, we present a novel data-driven model for predicting the GUR. The proposed approach utilized both the TS fuzzy neural network (TS-FNN) and the particle swarm algorithm (PSO) to predict the GUR. The particle swarm algorithm (PSO) is applied to optimize the parameters of the TS-FNN in order to decrease the error caused by the inaccurate initial parameter. This paper also applied the box graph (Box-plot) method to eliminate the abnormal value of the raw data during the data preprocessing. This method can deal with the data which does not obey the normal distribution which is caused by the complex industrial environments. The prediction results demonstrate that the optimization model based on PSO and the TS-FNN approach achieves higher prediction accuracy compared with the TS-FNN model and SVM model and the proposed approach can accurately predict the GUR of the blast furnace, providing an effective way for the on-line blast furnace distribution control.

6.
Opt Express ; 25(25): 31810-31815, 2017 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-29245851

RESUMO

Integrating narrow-bandwidth and wavelength tunability together is crucially important in upgrading the applications of optical parametric oscillators (OPO). Here, we have demonstrated a widely tunable, narrow-bandwidth and efficient mid-IR OPO pumped by a single-longitudinal-mode pulsed Yb-fiber laser. By restricting the bandwidth of the oscillated signal via self-seeding dual etalon-coupled cavities, the bandwidth of the idler can be suppressed to about 0.35 nm, with a wide tunable range of 2.85-3.05 µm, which can be achieved by synergistically adjusting the temperatures of PPMgLN crystal and one of the etalons. The maximum idler power at 3.031 µm is 2.67 W with an optical-to-optical conversion efficiency of 17.4%.

7.
Opt Express ; 25(4): 3373-3380, 2017 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-28241551

RESUMO

We experimentally demonstrate a ZnGeP2 based optical parametric oscillator (ZGP-OPO) with a record of the optical-to-optical conversion efficiency. To improve the conversion efficiency, we design and construct a double-pass pumped high-gain OPO and a matched large-sized high-peak-power pump beam to suppress the spatial walk-off and conversion. Pulse energy of 19 mJ with pulse width of 27.8 ns at 5 Hz in the mid-infrared 3-5 µm waveband is obtained in the doubly resonated ZGP-OPO, the beam quality M2 is about 9.6, and the corresponding optical-to-optical conversion efficiency reaches up to 75.7%.

8.
Anal Bioanal Chem ; 409(23): 5603-5612, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28730303

RESUMO

Cervical cancer is a common cancer among women and has a high morbidity and mortality. The traditional clinical methods for cervical cancer screening are invasive and limited in terms of cost and time. There is an unmet clinical need for new methods to aid clinicians in the rapid screening and auxiliary diagnosis of cervical precancer. Recently, breath analysis has become an attractive approach for investigation of cancer biomarkers and shows great potential in cancer screening owing to its high sensitivity, quickness, and non-invasive nature. In this pilot study, breath analysis by proton transfer reaction mass spectrometry (PTR-MS) was utilized for online analysis of the exhaled breath of 13 cervical cancer patients and 34 female healthy volunteers. The Mann-Whitney U test and stepwise forward linear discriminant analysis were performed for data statistics. On the basis of the statistical analysis, four characteristic ions at m/z 76, 87, 93, and 121 were found for discriminating cervical cancer. The sensitivity and specificity were calculated to be 92.3% and 88.2%, respectively, using the stepwise discriminant analysis. The possible identities of characteristic ions were also discussed in detail. Although there are some uncertainties in the identification of these characteristic ions and more participants (including cervical cancer patients and healthy volunteers) are needed to further confirm the results, the results in this study demonstrate that the online breath test using PTR-MS is a promising approach for cervical cancer screening.


Assuntos
Testes Respiratórios , Espectrometria de Massas/métodos , Neoplasias do Colo do Útero/metabolismo , Estudos de Casos e Controles , Feminino , Humanos , Prótons
9.
Rapid Commun Mass Spectrom ; 30 Suppl 1: 116-21, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27539425

RESUMO

RATIONALE: Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) was applied to analyze fresh meat species without sample pretreatment. The study demonstrates that the LAESI-MS technique is a promising, rapid and accurate method for meat identification using a protocol combining principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA). METHODS: A focused IR-laser was used for meat sample ablation at a wavelength of 2940 nm. The ablated particulates were carried through a transfer PTFE tube using air as carrier gas, delivered to the electrospray plume and ionized. A TOF-MS was used to detect the ion signal. The raw mass spectra were analyzed using the PCA and PLS-DA protocol. RESULTS: Five fresh meat samples, chicken, duck, pork, beef and mutton, were identified by the developed LAESI-MS technique using the protocol combining PCA and PLS-DA. The discrimination accuracy of all meat species is 100%, and the score plot also shows good identifying ability. CONCLUSIONS: Five fresh meat samples were analyzed using the LAESI-MS technique. Each set of raw mass data was collected within 30 s and analyzed by the PCA and PLS-DA protocol. Eighteen, 19, 18, 17, and 15 markers for chicken, duck, pork, beef, and mutton, respectively, have been selected successfully for meat identification. The results demonstrate that LAESI-MS is a new reliable and rapid method for meat identification. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Análise de Alimentos/métodos , Carne/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Bovinos , Galinhas , Patos , Lasers , Análise dos Mínimos Quadrados , Análise de Componente Principal , Suínos
10.
J Gastroenterol Hepatol ; 31(11): 1837-1843, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26996099

RESUMO

BACKGROUND: Esophageal cancer is a prevalent malignancy. There is a considerable demand for developing a fast and noninvasive method to screen out the suspect esophageal cancer patients who may undergo further clinical diagnosis. METHODS: The exhaled breathes from 29 esophageal cancer patients and 57 healthy people were directly measured using our home-made proton transfer reaction mass spectrometer (PTR-MS). Mann-Whitney U test and stepwise discriminant analysis were applied to identify the ions in the breath mass spectral data which can distinguish cancer cohort from healthy group. Receiver operating characteristics (ROC) analysis was also performed. RESULTS: Seven kinds of ions in the breath mass spectrum, viz., m/z 136, m/z 34, m/z 63, m/z 27, m/z 95, m/z 107 and m/z 45, have been found to distinguish between the esophageal cancer patients and healthy people with a sensitivity of 86.2% and a specificity of 89.5%, respectively. Compared with that from the healthy people, the breath mass spectra from esophageal cancer patients show that the mediant intensities of five kinds of ions were decrease and the rest two kinds of ions were increase. ROC analysis gave the area under the curve (AUC) of 0.943. CONCLUSIONS: This pilot study shows that the ionic characteristics of exhaled VOCs detected by PTR-MS may be used to differentiate between the esophageal cancer patients and the healthy people. Although the breath tests for more patients are needed to confirm such results, the present work indicates that the PTR-MS may be a promising method in the esophageal cancer screening.


Assuntos
Biomarcadores Tumorais/análise , Testes Respiratórios/métodos , Neoplasias Esofágicas/diagnóstico , Compostos Orgânicos Voláteis/análise , Adulto , Idoso , Estudos de Casos e Controles , Neoplasias Esofágicas/patologia , Expiração , Feminino , Humanos , Masculino , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Sistemas On-Line , Projetos Piloto , Curva ROC , Sensibilidade e Especificidade
11.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 37(3): 352-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26149152

RESUMO

OBJECTIVE: To investigate the potential association between monocyte chemotactic protein 1(MCP-1)in plasma and acute aortic dissection(AAD). METHODS: A total of 110 patients with Stanford type A AAD who had received emergent surgical treatment in Xiangya hospital from September 2011 to September 2014 were enrolled in as the study group;meanwhile,110 patients with simple hypertension who had received treatment in department of cardiology were chosen as the control group. The plasma level of MCP-1 was measured and then compared between these two groups. RESULTS: The plasma level of MCP-1 in the study group was(257.79±86.52)pg/ml,which was significantly higher than that in control group [(136.57±48.84)pg/ml](P<0.001). CONCLUSION: There may be a correlation between plasma MCP-1 level and AAD.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Quimiocina CCL2 , Humanos
12.
Anal Chem ; 86(7): 3338-45, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24605843

RESUMO

An electronic nose can detect highly volatile chemicals in foods, drugs, and environments, but it is still very much a challenge to detect the odors from crystalline compounds (e.g., solid explosives) with a low vapor pressure using the present chemosensing techniques in such way as a dog's olfactory system can do. Here, we inkjet printed silver nanoparticles (AgNPs) on cellulose paper and established a Raman spectroscopic approach to detect the odors of explosive trinitrotoluene (TNT) crystals and residues in the open environment. The layer-by-layer printed AgNP paper was modified with p-aminobenzenethiol (PABT) for efficiently collecting airborne TNT via a charge-transfer reaction and for greatly enhancing the Raman scattering of PABT by multiple spectral resonances. Thus, a Raman switch concept by the Raman readout of PABT for the detection of TNT was proposed. The AgNPs paper at different sites exhibited a highly uniform sensitivity to TNT due to the layer-by-layer printing, and the sensitive limit could reach 1.6 × 10(-17) g/cm(2) TNT. Experimentally, upon applying a beam of near-infrared low-energy laser to slightly heat (but not destruct) TNT crystals, the resulting airborne TNT in the open environment was probed at the height of 5 cm, in which the concentration of airborne species was lower than 10 ppt by a theoretical analysis. Similarly, the odors from 1.4 ppm TNT in soil and 7.2, 2.9, and 5.7 ng/cm(2) TNT on clothing, leather, and envelope, respectively, were also quickly sensed for 2 s without destoying these inspected objects.

13.
Opt Express ; 22(13): 15686-96, 2014 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-24977828

RESUMO

An electro-optically Q-switched high-energy Er:YAG laser with two polarizers is proposed. By using two Al(2)O(3) polarizing plates and a LiNbO(3) crystal with Brewster angle, the polarization efficiency is significantly improved. As a result, 226 mJ pulse energy with 62 ns pulse width is achieved at the repetition rate of 3 Hz, the corresponding peak power is 3.6 MW. To our knowledge, such a high peak power has not been reported in literature. With our designed laser, in-vitro teeth were irradiated under Q-switched and free-running modes. Results of a laser ablation experiment on hard dental tissue with the high-peak-power laser demonstrates that the Q-switched Er:YAG laser has higher ablation precision and less thermal damage than the free-running Er:YAG laser.


Assuntos
Gengiva/cirurgia , Terapia a Laser/instrumentação , Lasers de Estado Sólido , Dureza , Humanos
14.
Opt Lett ; 38(12): 2150-2, 2013 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23939006

RESUMO

A flash lamp pumped Cr,Er:YSGG laser utilizing a langasite (LGS) crystal as an electro-optic Q-switch is proposed and demonstrated. It is proved that a LGS crystal with relatively high damage threshold can be used as the electro-optic Q-switch at 2.79 µm, and 216 mJ pulse energy with 14.36 ns pulse width is achieved. Its corresponding peak power of pulse can reach 15 MW, to our knowledge the best result at a 2.79 µm wavelength.


Assuntos
Eletricidade , Lasers de Estado Sólido , Fenômenos Ópticos , Silicatos/química
15.
J Tradit Chin Med ; 33(4): 433-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24187861

RESUMO

OBJECTIVE: To compare the effects of integrated Chinese-Western therapy versus Western therapy alone on the survival rate of patients with non-small-cell lung cancer (NSCLC) at middle-late stage and to evaluate prognostic factors. METHODS: We selected 98 inpatients with middle-late stage NSCLC diagnosed from March 2009 to March 2011 and randomly divided them into two groups, with 49 cases in each group, and the clinical data were analyzed retrospectively. The control group was treated by the combined methods of Western Medicine, including chemotherapy, supportive treatment and symptomatic treatment. The observation group was treated by injection and prescriptions of Chinese medicine based on Traditional Chinese Medicine syndrome differentiation and by the same combined methods of western treatment used in the control group. After treatment, the survival rates of the patients were compared by the stage of cancer and evaluation of 24 prognostic factors analyzed by a Cox regression model, and the clinical data were statistically analyzed. RESULTS: The survival rates of all patients were over 90.0% at 1 and 3 months after treatment with no significant differences between the two groups (P > 0.05); In the observation group the survival rates at 6 months and 1 year were 93.4% and 42.8%, respectively, being superior to 85.6% and 18.3% in the control group (P < 0.05). The median survival time in the observation group was superior to the control group (P < 0.05); The effects of 24 prognostic factors were significantly better in the observation group than in the control group (P < 0.05). CONCLUSION: Integrated Chinese-western therapy can significantly improve the survival rate in patients with middle-late stage NSCLC and improve prognostic factors compared with western therapy alone.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Medicamentos de Ervas Chinesas/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/mortalidade , Adulto , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida
16.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 38(8): 804-8, 2013 Aug.
Artigo em Zh | MEDLINE | ID: mdl-23981998

RESUMO

OBJECTIVE: To determine the role of stress in myocardial protection of ischemic preconditioning (IPC). METHODS: Thirty rabbits were randomly divided into an IPC group, an etomidate (Etom) group, an ischemic/reperfusion (IR) group, a methylprednisolone (MP) group and a sham group. The ratio of infarction size versus risk area (infarct/risk) was calculated. The elevations of the serum creatine kinase (CK) activity and cardiac troponin I (cTnI) concentrations as well as the serum cortisol concentrations were measured. RESULTS: The percentages of infarct/risk in the IPC group, the MP group, the IR group, and the Etom group were (5.86±2.81)%, (11.28±3.62)%, (26.79±4.53)%, and (18.19±3.72)%, respectively. The elevations of the serum CK activity in the IPC group, the MP group, the IR group, and the Etom group were (255±89), (314±160), (855±371), and (768±404) U/L, respectively. The elevations of serum cTnI concentrations in the IPC group, the MP group, the IR group, and the Etom group were (3.6±0.6),(6.1±2.2), (8.1±3.6), and (6.4±1.6) µg/L, respectively. Those indicators among the groups were significantly different (P<0.05). Cortisol reaction was markedly diminished in the Etom group. CONCLUSION: A blunted cortisol reaction can markedly reduce the benefit of IPC while methylprednisolone shows cardioprotective effects, suggesting that stress might be involved in the myocardial protection of IPC.


Assuntos
Precondicionamento Isquêmico Miocárdico , Infarto do Miocárdio/fisiopatologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Estresse Fisiológico , Animais , Etomidato/farmacologia , Feminino , Hidrocortisona/sangue , Masculino , Coelhos
17.
Zhongguo Dang Dai Er Ke Za Zhi ; 15(5): 387-91, 2013 May.
Artigo em Zh | MEDLINE | ID: mdl-23676945

RESUMO

OBJECTIVE: To explore the role of spinal MAPK-ERK signal pathway in myocardial ischemia-reperfusion (I/R) injury. METHODS: Sixty male Sprague-Dawley(SD) rats (80-100 g) were randomly divided into 3 groups: sham (n=10), PD98059 (n=25) and I/R groups (n=25). Three days after successful intrathecal implantation, 5 µg DMSO was injected intrathecally into the sham group, and then the left coronary arteries were separated without being tied. Rats in the I/R and PD98059 groups were injected with 5 µL DMSO and PD98059 (5 µg) 30 minutes before thoractomy respectively. Then the left coronary artery was tied for 30 minutes followed by 120 minutes of reperfusion. After the experiments, the ERK phosphorylation condition of T1-T4 spinal cord segments was detected with immunofluorescence; the myocardiac apoptosic index and infarct size were measured. RESULTS: Expression of p-ERK in the I/R group was significantly higher than in the sham and PD98059 groups (P<0.05). Myocardial apoptotic index and infarct size in the PD98059 group were significantly lower than in the I/R group (P<0.05), but higher in the PD98059 group than in the sham group (P<0.05). CONCLUSIONS: The MAPK-ERK pathway in the superior thorathic spinal cord can be activated by myocardial ischemia-reperfusion and inhibition of the pathway can play a protective role in myocardial ischemia-reperfusion injury.


Assuntos
Sistema de Sinalização das MAP Quinases/fisiologia , Traumatismo por Reperfusão Miocárdica/etiologia , Medula Espinal/fisiologia , Animais , Apoptose/efeitos dos fármacos , Flavonoides/farmacologia , Flavonoides/uso terapêutico , Masculino , Infarto do Miocárdio/tratamento farmacológico , Ratos , Ratos Sprague-Dawley , Traumatismo por Reperfusão
18.
Opt Lett ; 37(11): 1986-8, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22660096

RESUMO

A flash lamp pumped 2.09 µm Cr, Tm, Ho:YAG laser utilizing a self-grown La(3)Ga(5)SiO(14) crystal as the electro-optic Q-switch generator is proposed and demonstrated for the first time. Operating at 3 Hz repetition rate, 520 mJ pulse energy with 35 ns pulse width is achieved by optimizing the Q-switch delay time and compensating for the thermal depolarization with a quarter-wave plate. The corresponding peak power is 14.86 MW, and the Q-switched-to-normal-mode energy extraction efficiency is 66.3%. To our knowledge, this Q-switched giant pulse is the best result reported to date in 2.09 µm laser resonator.


Assuntos
Eletricidade , Lasers de Estado Sólido , Fenômenos Ópticos , Silicatos , Fatores de Tempo
20.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(1): 29-32, 2012 Jan.
Artigo em Zh | MEDLINE | ID: mdl-22497120

RESUMO

The construction and performance study is reported for a newly developed ultraviolet photoionization ion mobility spectrometry (UV-IMS). In the present paper, an UV-IMS technique was firstly developed to detect eleven isomeric volatile organic compounds including the differences in the structure of carbon chain, the style of function group and the position of function group. Their reduced mobility values were determined and increased in this order: linears < branches < cycles, primary < secondary < tertiary, para- < meta- < ortho- and alcohols < acetones < aromas. The concentrations of analytes were obtained by means of exponential dilution method, and the experiments show that the limit of detection of the homemade UV-IMS was around ppb-ppm.


Assuntos
Espectrofotometria Ultravioleta/métodos , Compostos Orgânicos Voláteis/análise , Acetona , Álcoois
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA