Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circulation ; 147(17): 1264-1276, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36866664

RESUMO

BACKGROUND: Concerns have been raised about the long-term performance of aortic stent grafts for the treatment of abdominal aortic aneurysms, in particular, unibody stent grafts (eg, Endologix AFX AAA stent grafts). Only limited data sets are available to evaluate the long-term risks related to these devices. The SAFE-AAA Study (Comparison of Unibody and Non-Unibody Endografts for Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries Study) was designed with the Food and Drug Administration to provide a longitudinal assessment of the safety of unibody aortic stent grafts among Medicare beneficiaries. METHODS: The SAFE-AAA Study was a prespecified, retrospective cohort study evaluating whether unibody aortic stent grafts are noninferior to non-unibody aortic stent grafts with respect to the composite primary outcome of aortic reintervention, rupture, and mortality. Procedures were evaluated from August 1, 2011, through December 31, 2017. The primary end point was evaluated through December 31, 2019. Inverse probability weighting was used to account for imbalances in observed characteristics. Sensitivity analyses were used to evaluate the effect of unmeasured confounding, including assessment of the falsification end points heart failure, stroke, and pneumonia. A prespecified subgroup included patients treated from February 22, 2016, through December 31, 2017, corresponding to the market release of the most contemporary unibody aortic stent grafts (Endologix AFX2 AAA stent graft). RESULTS: Of 87 163 patients who underwent aortic stent grafting at 2146 US hospitals, 11 903 (13.7%) received a unibody device. The average age of the total cohort was 77.0±6.7 years, 21.1% were female, 93.5% were White, 90.8% had hypertension, and 35.8% used tobacco. The primary end point occurred in 73.4% of unibody device-treated patients versus 65.0% of non-unibody device-treated patients (hazard ratio, 1.19 [95% CI, 1.15-1.22]; noninferior P value of 1.00; median follow-up, 3.4 years). Falsification end points were negligibly different between groups. In the subgroup treated with contemporary unibody aortic stent grafts, the cumulative incidence of the primary end point occurred in 37.5% of unibody device-treated patients and 32.7% of non-unibody device-treated patients (hazard ratio, 1.06 [95% CI, 0.98-1.14]). CONCLUSIONS: In the SAFE-AAA Study, unibody aortic stent grafts failed to meet noninferiority compared with non-unibody aortic stent grafts with respect to aortic reintervention, rupture, and mortality. These data support the urgency of instituting a prospective longitudinal surveillance program for monitoring safety events related to aortic stent grafts.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Idoso , Estados Unidos , Idoso de 80 Anos ou mais , Masculino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Medicare , Stents , Desenho de Prótese
3.
J Vasc Interv Radiol ; 27(1): 133-141.e3, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26321051

RESUMO

PURPOSE: To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. MATERIALS AND METHODS: Rabbit Vx2 liver tumors were embolized with 100-300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3-5 per group; 18 total). RESULTS: Mean microvascular density was 70 vessels/mm(2) ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31(+) structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. CONCLUSIONS: Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas Experimentais/irrigação sanguínea , Neoplasias Hepáticas Experimentais/terapia , Microvasos , Análise de Variância , Animais , Microscopia de Fluorescência , Coelhos
4.
J Vasc Interv Radiol ; 27(1): 117-126.e3, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26549370

RESUMO

PURPOSE: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo. MATERIALS AND METHODS: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration. In vivo conspicuity was evaluated in a VX2 tumor model. RESULTS: Lipiodol was loaded into lyophilized beads using two glass syringes and a three-way stopcock. Maximum bead attenuation was achieved within 30 minutes. X-ray attenuation of radiopaque beads increased linearly (21-867 HU) with the amount of beads (0.4-12.5 vol%; R(2) = 0.9989). Doxorubicin loading efficiency and total amount eluted were similar to DC Bead (Biocompatibles UK Ltd); however, the elution rate was slower for radiopaque DEBs (P < .05). Doxorubicin concentration linearly correlated with x-ray attenuation of radiopaque DEBs (R(2) = 0. 99). Radiopaque DEBs were seen in tumor feeding arteries after administration by fluoroscopy, computed tomography, and micro-computed tomography, and their location was confirmed by histology. CONCLUSIONS: A simple, rapid method to produce radiopaque DEBs was developed. These radiopaque DEBs provided sufficient conspicuity to be visualized with x-ray imaging techniques.


Assuntos
Quimioembolização Terapêutica/instrumentação , Portadores de Fármacos , Neoplasias Hepáticas Experimentais/terapia , Microesferas , Animais , Modelos Animais de Doenças , Doxorrubicina/administração & dosagem , Óleo Etiodado/administração & dosagem , Fígado/diagnóstico por imagem , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Imagens de Fantasmas , Coelhos , Microtomografia por Raio-X
5.
J Mater Sci Mater Med ; 27(1): 13, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26676859

RESUMO

Clinical use of DC Bead™ loaded with doxorubicin (DEBDOX™) or irinotecan (DEBIRI™), for the treatment of primary and secondary tumours of the liver respectively, is showing great promise. Recently there has been a tendency to select smaller bead size ranges to treat tumours in an effort to allow more drug dose to be administered, improve tumoural penetration and resultant drug delivery and tumour coverage. Herein we describe the development and performance characterisation of a new DC Bead size range (DC BeadM1 (TM), 70-150 µm) capable of an increased bead delivery in the distal vasculature, corresponding to greater tumour coverage and drug dose delivered. Both unloaded and drug loaded DC BeadM1 were shown to have a greater density of distal volume of penetration although the ultimate distal level of penetration was the same as that of the 100-300 µm beads in an in vitro penetration model. Elution of doxorubicin was slower than irinotecan elution, but it was similar when comparing the same drug elution from 70 to 150 µm compared to 100-300 µm beads. Radiopaque versions of 70-150 and 100-300 µm beads were prepared in order to evaluate distribution ex vivo using µ-CT and doxorubicin distribution using epifluorescent microscopy. Liver distribution of the radiopaque versions of the beads was shown to be more distal and efficient at filling smaller vessels with the DC BeadM1 and correspondingly more beads were found per vessel histologically with a larger area of drug coverage with the smaller size range. This study indicates that the smaller (70-150 µm) beads should permit an increased dose of drug to be administered to both hypervascular and hypovascular tumours as compared to 100-300 µm beads.


Assuntos
Antineoplásicos/administração & dosagem , Camptotecina/análogos & derivados , Catéteres , Doxorrubicina/administração & dosagem , Portadores de Fármacos , Neoplasias Hepáticas Experimentais/tratamento farmacológico , Animais , Antineoplásicos/farmacocinética , Camptotecina/administração & dosagem , Camptotecina/farmacocinética , Doxorrubicina/farmacocinética , Irinotecano , Coelhos , Microtomografia por Raio-X
6.
J Mater Sci Mater Med ; 26(6): 198, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26105830

RESUMO

Therapeutic embolization of blood vessels is a minimally invasive, catheter-based procedure performed with solid or liquid emboli to treat bleeding, vascular malformations, and vascular tumors. Hepatocellular carcinoma (HCC) affects about half a million people per year. When unresectable, HCC is treated with embolization and local drug therapy by transarterial chemoembolization (TACE). For TACE, drug eluting beads (DC Bead(®)) may be used to occlude or reduce arterial blood supply and deliver chemotherapeutics locally to the tumor. Although this treatment has been shown to be safe and to improve patient survival, the procedure lacks imaging feedback regarding the location of embolic agent and drug coverage. To address this shortcoming, herein we report the synthesis and characterization of image-able drug eluting beads (iBeads) from the commercial DC Bead(®) product. Two different radiopaque beads were synthesized. In one approach, embolic beads were conjugated with 2,3,5-triiodobenzyl alcohol in the presence of 1,1'-carbonyldiimidazol to give iBead I. iBead II was synthesized with a similar approach but instead using a trimethylenediamine spacer and 2,3,5-triiodobenzoic acid. Doxorubicin was loaded into the iBeads II using a previously reported method. Size and shape of iBeads were evaluated using an upright microscope and their conspicuity assessed using a clinical CT and micro-CT. Bland and Dox-loaded iBeads II visualized with both clinical CT and microCT. Under microCT, individual bland and Dox loaded beads had a mean attenuation of 7904 ± 804 and 11,873.96 ± 706.12 HU, respectively. These iBeads have the potential to enhance image-guided TACE procedures by providing localization of embolic-particle and drug.


Assuntos
Quimioembolização Terapêutica/métodos , Meios de Contraste/química , Meios de Contraste/síntese química , Antineoplásicos/administração & dosagem , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/química , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Diaminas/química , Doxorrubicina/administração & dosagem , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Teste de Materiais , Microesferas , Imagens de Fantasmas , Álcool de Polivinil/química , Ácidos Tri-Iodobenzoicos/química , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA