Pediatr Radiol ; 54(7): 1197-1204, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38769141

RESUMO

BACKGROUND: Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce. OBJECTIVE: To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations. MATERIALS AND METHODS: Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.625-mm multidetector; and Aquilion ONE GENESIS Edition (Canon Medical Systems, Otawara, Japan) with a 320-row, 0.5-mm multidetector. Three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The scatter dose values measured by the OSLDs were compared between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width during pediatric chest CT examinations. RESULTS: Median equivalent doses for the helical and axial scans were 0.12 and 0.12 mSv/mGy for the newborn, 0.17 and 0.16 mSv/mGy for the 1-year-old, and 0.18 and 0.15 mSv/mGy for the 5-year-old, respectively, when using the Revolution CT. With the Revolution CT, no significant differences were observed in the scatter doses between helical and axial scans in the newborn and 1-year-old phantoms. However, the lens scatter dose for the helical scan was approximately 20-35% higher than that for the axial scan in the 5-year-old phantom (P<0.01). The median equivalent doses of eye lenses for the helical and axial scans were 0.12 and 0.07 mSv/mGy for the newborn, 0.07 and 0.05 mSv/mGy for the 1-year-old, and 0.14 and 0.12 mSv/mGy for the 5-year-old, respectively, when using the Aquilion ONE. With the Aquilion ONE, lens scatter doses for the helical scan were approximately 70%, 40%, and 30% higher in the newborn, 1-year-old, and 5-year-old phantoms, respectively, than those for the axial scan (P<0.01). CONCLUSIONS: When using the Aquilion ONE, lens scatter doses for the helical scan were significantly higher in all three phantoms than those for the axial scan. In contrast, when using the Revolution CT, the lens scatter dose for the helical scan was significantly higher in the 5-year-old phantom than that for the axial scan. These results suggest that although scattered doses may vary with respect to the CT scanner and body size, they are generally lower in the case of axial scans.


Assuntos
Cristalino , Doses de Radiação , Espalhamento de Radiação , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Cristalino/diagnóstico por imagem , Cristalino/efeitos da radiação , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Radiometria , Exposição à Radiação , Recém-Nascido , Lactente , Pré-Escolar
2.
Pediatr Radiol ; 54(5): 758-763, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38308740

RESUMO

BACKGROUND: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS: We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS: There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION: Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.


Assuntos
Cristalino , Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica , Glândula Tireoide , Humanos , Glândula Tireoide/diagnóstico por imagem , Recém-Nascido , Cristalino/diagnóstico por imagem , Cristalino/efeitos da radiação , Radiografia Torácica/métodos , Radiografia Torácica/instrumentação , Pré-Escolar , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada Espiral/métodos
3.
J Appl Clin Med Phys ; 21(8): 272-277, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32614147

RESUMO

Three-dimensional computed tomographic angiography (3D-CTA) is widely used to evaluate the inner diameters of vessels and the anatomical vascular structure prior to endoscopic aortic surgery or transcatheter valve implantation. Virtual monoenergetic imaging (VMI) is a new application in dual-energy CT (DECT). We evaluated the potential for contrast dose reduction in preoperative aortic CTA using VMI. To evaluate performance in terms of image quality and vessel shape, we quantified the contrast-to-noise ratio (CNR) and the vessel diameter using a cylinder phantom we developed, and used volume rendering to assess visual quality. All VMI had improved CNR values compared with conventional 120 kVp images at an iodine content of 15 mgI/mL. In each image, a virtual mono-energy of 40 keV yielded the highest CNR value, and an iodine content of 9 mgI/mL was comparable to that of conventional images with an iodine content of 15 mgI/mL. The circularity indices (CI) of the vascular model at 15, 12, and 9 mgI/mL were similar to those of the reference condition using conventional voltages; however, CI was degraded at iodine contents of 6 and 3 mgI/mL with VMI. In the case of iodine content of 15 mgI/mL, VMI was superior, with conventional image by visual evaluation. In the cases of iodine contents of 12 and 9 mgI/mL, image quality was judged to be almost the same level when comparing 12 and 9 mgI/mL to conventional images. In the case of 6 and 3 mgI/mL, reference image using conventional technique was superior to that of VMI. We demonstrated in that decreasing contrast iodine content is possible using VMI with an energy of 40 keV for preoperative aortic 3D-CTA.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Angiografia , Angiografia por Tomografia Computadorizada , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
4.
Radiat Prot Dosimetry ; 200(2): 143-148, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37987195

RESUMO

To determine whether using lower-tube voltage reduces the scattered dose for the lens during paediatric thoracic computed tomography (CT). Two paediatric anthropomorphic phantoms (ATOM Phantom, CIRS, Norfolk, Virginia, USA) representing a newborn and 5-year-old were placed on the gantry of CT scanner, and optically stimulated luminescence dosemeters were placed on the left and right lenses, in front of the left and right thyroid glands, in front of the left and right mammary glands, and in front of and behind the mammary gland level and we measured scattered dose of the optically stimulated luminescence dosemeter was compared for each phantom between 80 and 120 kVp. Significant differences were observed in the scatter doses for the lens between 80 and 120 kVp (p < 0.01). Compared with the 120 kVp scan, the scatter doses for the lens were ~15-40% lower in newborn and 5-year-olds using the 80 kVp scan during paediatric CT.


Assuntos
Cristalino , Tomografia Computadorizada por Raios X , Recém-Nascido , Criança , Humanos , Pré-Escolar , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Cintilografia
5.
Artigo em Inglês | MEDLINE | ID: mdl-38997113

RESUMO

Equivalent doses for the eye lenses, thyroid, and mammary glands were measured and compared between one adult and three pediatric anthropomorphic phantoms during chest computed tomography (CT) using 40 mm volume helical scan on the Aquilion ONE GENESIS Edition CT equipment. Placing an optically stimulated luminescence dosemeter (OSLD) on the eye lenses, thyroid, and mammary gland, we measured and compared the equivalent dose of OSLD among different phantoms during chest CT using a helical scan. Compared with adults, the equivalent doses to the eye lens, thyroid, and mammary glands were ~81%, 77%, and 63% lower in newborns, 1-year-olds, and 5-year-olds using comparable image noise during chest CT.

6.
Radiol Phys Technol ; 10(2): 213-226, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28025782

RESUMO

The goal of this study is to develop a more appropriate shielding calculation method for computed tomography (CT) in comparison with the Japanese conventional (JC) method and the National Council on Radiation Protection and Measurements (NCRP)-dose length product (DLP) method. Scattered dose distributions were measured in a CT room with 18 scanners (16 scanners in the case of the JC method) for one week during routine clinical use. The radiation doses were calculated for the same period using the JC and NCRP-DLP methods. The mean (NCRP-DLP-calculated dose)/(measured dose) ratios in each direction ranged from 1.7 ± 0.6 to 55 ± 24 (mean ± standard deviation). The NCRP-DLP method underestimated the dose at 3.4% in fewer shielding directions without the gantry and a subject, and the minimum (NCRP-DLP-calculated dose)/(measured dose) ratio was 0.6. The reduction factors were 0.036 ± 0.014 and 0.24 ± 0.061 for the gantry and couch directions, respectively. The (JC-calculated dose)/(measured dose) ratios ranged from 11 ± 8.7 to 404 ± 340. The air kerma scatter factor κ is expected to be twice as high as that calculated with the NCRP-DLP method and the reduction factors are expected to be 0.1 and 0.4 for the gantry and couch directions, respectively. We, therefore, propose a more appropriate method, the Japanese-DLP method, which resolves the issues of possible underestimation of the scattered radiation and overestimation of the reduction factors in the gantry and couch directions.


Assuntos
Doses de Radiação , Proteção Radiológica , Espalhamento de Radiação , Tomografia Computadorizada por Raios X
7.
Health Phys ; 109(2): 104-12, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26107430

RESUMO

A dosimetry system for computed tomography (CT) examinations, named WAZA-ARI, is being developed to accurately assess radiation doses to patients in Japan. For dose calculations in WAZA-ARI, organ doses were numerically analyzed using average adult Japanese male (JM) and female (JF) phantoms with the Particle and Heavy Ion Transport code System (PHITS). Experimental studies clarified the photon energy distribution of emitted photons and dose profiles on the table for some multi-detector row CT (MDCT) devices. Numerical analyses using a source model in PHITS could specifically take into account emissions of x rays from the tube to the table with attenuation of photons through a beam-shaping filter for each MDCT device based on the experiment results. The source model was validated by measuring the CT dose index (CTDI). Numerical analyses with PHITS revealed a concordance of organ doses with body sizes of the JM and JF phantoms. The organ doses in the JM phantoms were compared with data obtained using previously developed systems. In addition, the dose calculations in WAZA-ARI were verified with previously reported results by realistic NUBAS phantoms and radiation dose measurement using a physical Japanese model (THRA1 phantom). The results imply that numerical analyses using the Japanese phantoms and specified source models can give reasonable estimates of dose for MDCT devices for typical Japanese adults.


Assuntos
Tomografia Computadorizada Multidetectores , Imagens de Fantasmas , Doses de Radiação , Adulto , Feminino , Humanos , Masculino , Radiometria
8.
Radiat Prot Dosimetry ; 146(1-3): 241-3, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21493598

RESUMO

A web system of WAZA-ARI is being developed to assess radiation dose to a patient in a computed tomography examination. WAZA-ARI uses one of organ dose data sets corresponding to the options selected by a user to describe examination conditions. The organ dose data have been derived by the Particle and Heavy Ion Transport code system, combined with Japanese male (JM) phantom. The configuration of JM phantom is adjusted to the averaged JM adult. In addition, a new phantom is introduced by removing arms from JM phantom to take into account for dose calculations in torso examinations. Some of the organ doses by JM phantom without arms are compared with results obtained by using a MIRD-type phantom, which was applied in some previous dosimetry systems.


Assuntos
Imagens de Fantasmas , Radiometria/instrumentação , Tomografia Computadorizada por Raios X , Adulto , Carga Corporal (Radioterapia) , Humanos , Masculino , Método de Monte Carlo , Doses de Radiação , Eficiência Biológica Relativa
9.
Radiat Prot Dosimetry ; 146(1-3): 244-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21502296

RESUMO

A web-based dose computation system, WAZA-ARI, is being developed for patients undergoing X-ray CT examinations. The system is implemented in Java on a Linux server running Apache Tomcat. Users choose scanning options and input parameters via a web browser over the Internet. Dose coefficients, which were calculated in a Japanese adult male phantom (JM phantom) are called upon user request and are summed over the scan range specified by the user to estimate a normalised dose. Tissue doses are finally computed based on the radiographic exposure (mA s) and the pitch factor. While dose coefficients are currently available only for limited CT scanner models, the system has achieved a high degree of flexibility and scalability without the use of commercial software.


Assuntos
Internet , Imagens de Fantasmas , Radiometria/instrumentação , Tomografia Computadorizada por Raios X , Adulto , Carga Corporal (Radioterapia) , Humanos , Masculino , Método de Monte Carlo , Doses de Radiação , Eficiência Biológica Relativa